• Title/Summary/Keyword: Dead layer

Search Result 114, Processing Time 0.047 seconds

Dead Layer Thickness and Geometry Optimization of HPGe Detector Based on Monte Carlo Simulation

  • Suah Yu;Na Hye Kwon;Young Jae Jang;Byungchae Lee;Jihyun Yu;Dong-Wook Kim;Gyu-Seok Cho;Kum-Bae Kim;Geun Beom Kim;Cheol Ha Baek;Sang Hyoun Choi
    • Progress in Medical Physics
    • /
    • v.33 no.4
    • /
    • pp.129-135
    • /
    • 2022
  • Purpose: A full-energy-peak (FEP) efficiency correction is required through a Monte Carlo simulation for accurate radioactivity measurement, considering the geometrical characteristics of the detector and the sample. However, a relative deviation (RD) occurs between the measurement and calculation efficiencies when modeling using the data provided by the manufacturers due to the randomly generated dead layer. This study aims to optimize the structure of the detector by determining the dead layer thickness based on Monte Carlo simulation. Methods: The high-purity germanium (HPGe) detector used in this study was a coaxial p-type GC2518 model, and a certified reference material (CRM) was used to measure the FEP efficiency. Using the MC N-Particle Transport Code (MCNP) code, the FEP efficiency was calculated by increasing the thickness of the outer and inner dead layer in proportion to the thickness of the electrode. Results: As the thickness of the outer and inner dead layer increased by 0.1 mm and 0.1 ㎛, the efficiency difference decreased by 2.43% on average up to 1.0 mm and 1.0 ㎛ and increased by 1.86% thereafter. Therefore, the structure of the detector was optimized by determining 1.0 mm and 1.0 ㎛ as thickness of the dead layer. Conclusions: The effect of the dead layer on the FEP efficiency was evaluated, and an excellent agreement between the measured and calculated efficiencies was confirmed with RDs of less than 4%. It suggests that the optimized HPGe detector can be used to measure the accurate radioactivity using in dismantling and disposing medical linear accelerators.

Analysis of the Dead Layer Thickness effect and HPGe Detector by Penelope Simulation (Penelope Simulation에 의한 불감층 두께 효과 및 HPGe 검출기 분석)

  • Jang, Eun-Sung;Lee, Hyo-Yeong
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.7
    • /
    • pp.801-806
    • /
    • 2018
  • Germanium crystals have a dead layer that causes efficiency deterioration because the layer is not useful for detection but strongly weakens the photons. Thus, when the data provided by the manufacturer is used in the detector simulation model, there is a slight difference between the calculated efficiency and the measured efficiency.The shape and dimensions of the high purity germanium (HPGe) detector were determined by CT scans to accurately characterize the shape for the Monte Carlo roll simulation. It is found that the adjustment of the dead layer is a good match with the relative deviation of ${\pm}3%$ between the measurement efficiency and the simulation efficiency at the energy range of 50 - 1500 keV. Simulation data were compared by varying the thickness of the dead layer. The new Monte Carlo simulations were compared with the experimental results to obtain new blank layer thicknesses. The difference in dead layer results for the 1.5 mm thick end cap simulation model in 1.4 and 1.6 mm thick End Cap simulation models was a systematic error due to the accuracy of the end cap dimensions. After considering all errors including statistical errors and systematic errors, the thickness of the detector was calculated as $1.02{\pm}0.14mm$. Therefore, it was confirmed that the increase in the thickness of the dead layer causes the effect to be effected on the efficiency reduction.

Performance Enhancement for Vertical Handover in Heterogeneous Wireless Networks Using Freeze DeadLine (이기종 무선망 환경에서 Freeze DeadLine 기법을 통한 수직 핸드오버의 성능개선)

  • Jeong, Hyeon-Jin;Choi, Seung-Sik
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.39B no.8
    • /
    • pp.499-509
    • /
    • 2014
  • In this paper, we propose that a FDL(Freeze DeadLine) Algorithm to solve handover problems in heterogeneous wireless networks. Many previous studies concentrated on low level layer to solve handover problems. In this paper, however, we concentrate on high level handover problems such as network layer and transport layer. We analyze handover's problems of transport layer in Heterogeneous wireless network, propose the FLD algorithm for better performance than others studies. The Proposed method is analyzed by theoretical frames and we verify that the propose method using the NS-2(Network Simulation - 2).

Structure and Dynamics of Pinus densiflora Community in Mt. Kaya (가야산(伽倻山) 소나무(Pinus densiflora)군락(群落)의 구조(構造) 및 동태(動態))

  • Bae, Kwan Ho;Hong, Sung Cheon
    • Journal of Korean Society of Forest Science
    • /
    • v.85 no.2
    • /
    • pp.260-270
    • /
    • 1996
  • Structure and dynamics of Pinus densiflora community in Mt. Kaya were studied to provide the information needed for management of Pinus densiflora forest in the southern inland of Korea. Stratification structure of Pinus densiflora community in the lower and middle slope consisted of tree layer(10~15m), subtree layer(4~10m), shrub layer(1~4m), and herb layer(below 1m), while in the rock zone of ridge and top area consisted of tree layer(7~10m), subtree layer(2~7m), shrub layer(1~2m), and herb layer(below 1m). According to the diameter distribution of tree species in Pinus densiflora community, secondary Pinus densiflora forest will gradually decline. Its forest may be replaced by Quercus mongolica, Quercus serrata, Carpinus laxiflora, C. cordata, and Fraxinus rhychophylla in the lower slope, and by Quercus mongolica in the middle slope. Pinus densiflora forest has its seedlings and saplings in ridge and top area, so it may be sustained. By taking cores from Pinus densiflora trees in research area, it could be obtained that in the lower and middle slope, age of Pinus densiflora forest was about 80~90 years old. When the age of its trees was about 72~80 years old, withering trees of standing dead occurred. Disturbance regime of Pinus densiflora community in Mt. Kaya consisted of standing dead, uprooting and limbfall, these were 70.6%, 17.6% and 11.8% respectively. It takes about 100~110 years for advance growth of Pinus densiflora in ridge and top area to reach tree layer. During the period, it has twice chances of disturbance in standing dead. Annual diameter growth of Pinus densiflora was 2.45~2.9mm in the lower and middle slope, while it was 1.75mm in ridge and top region, by measuring cores.

  • PDF

Design of a Variable Structure Speed Controller having a Dead Zone Switching layer for the Sinusoidal type Brushless DC Motor (데드 존 스위칭 영역을 갖는 정현파형 브러시리스 직류전동기의 가변구조 속도제어기 설계)

  • 김세일;최중경;박승엽
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.3 no.3
    • /
    • pp.639-650
    • /
    • 1999
  • In this paper, a chattering alleviation VSS controller for the sinusoidal type BLDC motor is designed. Dead Zone function is proposed to change the chattering occurring in the transient state from high frequency to low frequency and time-varying gains are applied for the control input to eliminate the steady state excessive chattering in the conventional ISM. The proposed Dead Zone function represents the sliding layer composed of two switching surfaces and if a state vector exists in this layer, the chattering don't occur. Simulation and experimental results confirm the useful effects of the above algorithm.

  • PDF

Dead-end Mode Operation of a Large Scale PEM Fuel Cell Stack (대면적 고분자전해질 연료전지의 데드엔드 운전)

  • Jeong, Jeehoon;Shin, Hyunkhil;Han, In-Su;Seo, Hakyu;Kim, Minsung;Cho, Sungbaek;Hur, Taeuk
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.11a
    • /
    • pp.83.1-83.1
    • /
    • 2010
  • A Dead-end mode operation is one of the best way to maximize the gas usage rate. But, some components of fuel cell stack like gas diffusion layer(GDL) or membrane can be damaged in dead-end mode operation. In this study, a Large Scale Polymer electrolyte membrane fuel cell(PEMFC) for a dead-end operation has been developed. The stack is composed with 4 cells which has over 400cm2 of active area. Hydrogen is used as a fuel, and oxygen is used as a oxidant. The dead-end operation performance was evaluated by a long-term dead-end mode operation. The fuel cell stack is operated over 1,500 hours in dead-end mode operating fuel cell test station. And the performance change of the fuel cell stack was investigated.

  • PDF

Digital variable structure control of a hot-water heating control system with long dead time (긴 지연시간을 갖는 온수난방 제어시스템의 디지틀 가변구조제어)

  • 안병천;장효환
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1991.10a
    • /
    • pp.232-237
    • /
    • 1991
  • Digital Variable Structure Controller(DVSC) is proposed to control variable speed recirculating pump for hot-water heating control system. In this study, nonlinear sliding line is used beyond output error boundary layer and PID sliding line is used within the layer. For long dead time compensation, constraint is added to Smith predictor algorithm. Steady state error is eliminated by using the proposed sliding line in spite of heating load change. By decreasing sampling time, good sliding motion is yielded but system output noise bv flow dynamics is amplified.

  • PDF

Preventing Method against the Occurrence of a Corona between a Dead End clamp and a Porcelain Insulator Used in 154kV Substation

  • Han, Woon-Ki;Choi, Jong-Soo;Lee, Jun;Kim, Jae-Chul
    • International Journal of Safety
    • /
    • v.6 no.2
    • /
    • pp.22-26
    • /
    • 2007
  • An episode of corona is a heterogeneity-caused electric discharge that occurs when electric fields are formed layer on layer and concentrated on an electrode. Electric wires built at the tip of 154kV private facilities use dead end clamp spawns corona from homogeneity caused by field concentration. Corona induces power loss, noise, insulator failure and more. In this research, we've studied the characteristics of coronas that take place in porcelain insulators and terminal electric wires of supporting hard wares (dead end clamp) that are set up as spares in the 154kV private facilities use hydroelectricity installations to support electric wires. Corona, which cannot be identified by regular methods, was measured utilizing UV image camera. As the result of measuring corona via UV image camera, we've confirmed that the depletion of insulators was accelerated following the wire end treatment method and validated the stress intensity of insulators at various lengths of bare wires caused by electric fields via FEMLAB. We have also proposed a new model for relieving homogeneity-caused field concentration, and after analyzing the proposed model via FEMLAB, we've confirmed that the concentration of field distribution was indeed reduced. Such results are exploited in installation of private facilities use equipments, maintenance of insulators and hard wares as well as safety enhancement, and are anticipated to be effectively utilized in corona prevention measures.

The Effect of $ZrO_2-Y_2O_3\;(YSZ)$ Buffer Layer on Layer on Low-Field Magnetoresistance of LSMO Thin Films ($ZrO_2-Y_2O_3\;(YSZ)$ 중간층이 저 자장영역에서의 LSMO 박막의 자기저항 특성에 미치는 영향)

  • 심인보;오영제;최세영
    • Journal of the Korean Magnetics Society
    • /
    • v.9 no.6
    • /
    • pp.306-311
    • /
    • 1999
  • $La_{2/3}Sr_{1/3}MnO_3(LSMO)/YSZ/SiO_2/Si(100)$ polycrystalline thin films were fabricated be chelated sol-gel method The effect of YSZ buffer layer at low field (120 Oe) spin-polarized tunneling magnetotransport (TMR) properties of LSMO thin film was studied at room temperature. Single perovskite LSMO thin films was obtained. The maximum TMR ratio was increased from 0.2 to 0.42 % by the insertion of YSZ buffer. YSZ as diffusion barrier was attributed to the fine microstructure of LSMO thin films and the reduction of dead layer between LSMO and $SiO_2/Si(100)$ interfaces.

  • PDF