• Title/Summary/Keyword: Dead Volume

Search Result 134, Processing Time 0.021 seconds

EFFECT OF SEASON ON SEMINAL CHARACTERISTICS OF HOLSTEIN BULL UNDER SEMI-ARID ENVIRONMENT I. BIOPHYSICAL CHARACTERISTICS

  • Salah, M.S.;El-Nouty, F.D.;Al-Hajri, M.R.;Mogawer, H.H.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.5 no.3
    • /
    • pp.439-447
    • /
    • 1992
  • Eight healthy Holstein bulls, 4-6 years old were used to study the effect of season of the year on the biophysical characteristics of semen. Semen was collected twice a week by AV (artificial vagina) over one-year period. The analyses revealed that all the basic seminal traits studied were differed significantly due to season, except the ejaculate volume and consistency and the percentage of swollen spermatozoa in a hypo-osmotic fructose-citrate solution. Ejaculates collected during hot summer season had significantly lower sperm motility, concentration and total counts, and higher percentage of dead spermatozoa than those collected during winter time. Warm spring had moderate semen quality. The temperature-humidity index was calculated and it was associated (p < 0.01) negatively with the ejaculate pH, sperm concentration and total counts, and positively with the % of dead sperms. Ejaculate volume, percentage of swollen spermatozoa, individual motilities did not correlate significantly with the change in temperature-humidity index values. The total live, motile spermatozoa per ejaculate during both the winter and spring seasons showed significant increase of about 37% and 32% respectively over the summer season. Also, rectal temperatures of the bulls were elevated during the hot summer season, while the values of blood hemoglobin and packed-cell volume were decreased.

The Optimum Design Conditions of Stirling Engines Using The Ideal Adiabatic Model (이상적인 단열모델에 의한 스터링기관의 최적설계조건)

  • 유호선
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.14 no.3
    • /
    • pp.656-663
    • /
    • 1990
  • To investigate the optimum design conditions of Stirling Engines at the preliminary design stage, comparative study between adoabatoc analysis based on an approximate analytical solution to the Ideal Adiabatic Model and the existing isothermal analysis has been carried out. The optimum phase angle obtained from adiabatic analysis to achieve the maximum work with given combination of design parameters is greater than that from isothermal analysis, while the optimum swept volume ratio is smaller. Effect of variation in the temperature ratio on the work parameter is proved to be stronger in adiabatic analysis. On the contrary, the work parameter by adiabatic analysis is less sensitive to a change in the dead volume ratio. Especially in adiabatic analysis there exists the optimum dead volume ratio maximizing the work parameter, which may provide a lower limit of it. Considering that the adiabatic model is more reasonable, signifiant differences between two methods lead to the conclusion that adiabatic analysis is preferable to isothermal one for the preliminary design of Stirling Engines.

Studies for the osmotic parameter of liposomes

  • Yu, Byung-Sul;Seo, Weon-Gyo;Jeon, Young-Ho
    • Archives of Pharmacal Research
    • /
    • v.10 no.2
    • /
    • pp.94-99
    • /
    • 1987
  • By using the former equation (8), we modified the equation which can show the dissimilar osmotic behavior of liposome with composition change. The slope of the new equation was presented as the ratio of osmotically active volume (V$_{act}$= ) to the total volume (V$_{totel}$= $_{acl}$+ V$_{dead}$ ; V$_{dead}$ is osmotically inactive volume) of loposomes, we defined is as a Z-value, which can elucidate the dissimilarity of the osmotic activity of multilamellar liposomes with the change of phospholipid composition and the differences of physicochemical properties of liposomes. Z-value was applied for studying the physico-chemical properties of liposomal membrane. The factor that affects on the Z-value was not the lipid concentration of liposome stock dispersion but the lipid composition of liposomal membrane. As the content of dicetylphosphate, the negative charged phospholipid, was increased, the osmotic activity, represented by Z-value, of multilamellar liposome was decreased. Using the hypertonic conditions (shrinking region), Z-value steadily increased and reached a maximum at 10 mole percent cholesterol with increasing the cholesterol content.

  • PDF

Fluorescence photon counting rate as a function of dye concentration: Effect of dead time of photon detector (색소 농도에 따른 형광 광자의 계수율 : 광자 검출기의 dead time 효과)

  • 고동섭
    • Korean Journal of Optics and Photonics
    • /
    • v.8 no.4
    • /
    • pp.353-355
    • /
    • 1997
  • A single molecule detection system, which consists of confocal fluorescence microscope and single photon counter, has been used to observe the dye concentration dependence of photon counting rate. With increasing concentration, a saturation effect of counting is observed and demonstrated on the basis of the dead time of photon detector. The equations presented here show the relations between the counting rate and some parameters such as probe volume, quantum efficiency of detector, and fluorescence photon number entered onto detector. The signal-to-noise ratio is also discussed briefly.

  • PDF

A Study on the Theoretical Analysis and Optimal Design Conditions for the $\alpha$ type Stirling Engine ($\alpha$형 스터링 엔진의 최적 설계 조건)

  • 강문규;이택희;유재환
    • Journal of the Korean Society of Safety
    • /
    • v.13 no.4
    • /
    • pp.142-154
    • /
    • 1998
  • A stirling engine is a mechanism used to convert heat to power and operates on a closed regenerative thermodynamic cycle with compression and expansion of the working fluid at different temperature. The performance of a stilting cycle machine is a function of six independent parameters, namely; (1) speed N(r.p.m), (2) pressure of the working fluid p(Pa), (3) ratio of the temperature in the compression and expansion space ${\tau}(=T_C/T_E)$ , (4) ratio of the swept volumes in these two spaces K, (5) phase angle $\alpha$ and (6) dead volume ratio X. This paper describes the procedure and presents the results of computations carried out to establish the optimum combinations of these six parameters for maximum engine output for the machine acting as a prime mover, over a combined temperature range from $300^{\circ}K$ to $1000^{\circ}K$ and dead volume ratio X ranging from 0.1 to 2.0. The output of a stilting cycle machine can be expressed in terms of nondimensional power in several different ways. Four methods were studied in detail, the parameters optimized and design charts and engine power charts prepared. The results of this paper may be useful as a guide to the likely effects on the performance of some of the important design parameters and regenerator design.

  • PDF

A new merging-zone flow injection system for the quantification of ferrous and ferric ions in aqueous solution and sludge of wastewater

  • Farhood, Ahmed Saleh;Taha, Dakhil Nassir
    • Analytical Science and Technology
    • /
    • v.35 no.5
    • /
    • pp.218-227
    • /
    • 2022
  • A simple and fast throughput flow injection (FI) system with a merging-zone technique was designed to determine ferrous and ferric in an aqueous solution. The method is based on the direct reaction of ferrous with a Bathophenanthroline reagent (Bphen) in acidic media. The forming red complex absorbs light at 533 nm. All conditions of the flow injection system were investigated. The analytical curve of ferrous was linear in the range of 0.07 to 4 mg/L with an r2 value of 0.9968. The detection and quantification limits were 0.02 and 0.04 mg/L, respectively. The molar absorptivity and Sandell's sensitivity were 4.0577 × 106 L/mol cm and 25 × 10-5 ㎍/cm2, respectively. The homemade valve was low-cost with high repeatability (n = 7) at an RSD of 1.26 % and zero dead volume. The values of the dispersion coefficient were 2.318, 2.022, and 1.636 for the concentrations of 0.2, 1, and 3 mg/L, respectively. The analysis throughput of the designed flow injection unit was 57 sample per hour.

Characteristics of Dead and Live Trees infested by Pine Needle Gall Midge, Thecondiplosis japonensis (Diptera : Cecidomyiidae) (솔잎혹파리 피해림지(被害林地)에서의 고사목(枯死木)과 생존목(生存木)의 특성(特性))

  • Chung, Yeong-Jin;Park, Young-Seuk;Kim, Chul-Su;Chon, Tae-Soo;Lee, Buom-Young
    • Journal of Korean Society of Forest Science
    • /
    • v.89 no.2
    • /
    • pp.256-259
    • /
    • 2000
  • D.B.H., height, crown length, crown width, crown form, crown area, and crown volume of dead and live trees were measured and the discriminant analysis was conducted to assess individual tree risk-rating in the pine forest seriously infested by the pine needle gall midge. Thecodiplosis japonensis. Crown length, crown form, crown area, and crown volume of live tree were significantly higher than those of dead tree, while D.B.H. and tree height were not different significantly. These results represent that the trees with higher and wider crown and larger crown volume have relatively higher probability to survive from the infestation by the pine needle gall midge. Variables selected in the functions of discriminant analysis were crown area, ratio of crown length, crown form, ratio of crown volume to crown area, and ratio of crown width.

  • PDF

Treatment of Chronic Empyema with Autologous Tissues (자가조직을 이용한 만성 농흉의 치료)

  • Hur, J.;Jang, B.H.;Lee, J.T.;Kim, K.T.
    • Journal of Chest Surgery
    • /
    • v.25 no.8
    • /
    • pp.850-855
    • /
    • 1992
  • Dead space of empyema occurrs from incomplete obliteration of infected pleural space from pulmonary tuberculosis, pyogenic infection, esophageal disease and post pulmonary resection. Chronic empyema can be treated by obliteration of dead space with autologous tissues such as, extrathoracic muscle flap and omental flap and thorachoplasty. Between May, 1986 to July, 1991 we treated 17 chronic empyema patients with autologous tissues and analysed the result. 1. Sex distribution was 14 males and 3 females between 5~62 years old. [mean 39.7 years old] 2. The volume of the dead space ranged from 100 to 450cc. [mean 213. 76cc] 3. The majority of used muscle flap were serratus anterior and latissimus dorsi, and there were 2 cases of am ntal flap. 4. The majority of underlying disease were pulmonary tuberculosis and there were 8 BPF[47%] in 17 patients 5. In 7 cases, thorachoplsty was needed. 6. Three cases recurred and there were no death.

  • PDF

The Effects of Pulmonary Resectional Surgery for Cavitary Tuberculosis on Ventilation and Arterial Respiratory Gases (폐결핵환자에서 폐절제술이 폐기능에 미치는 영향에 관한 연구)

  • 이현우
    • Journal of Chest Surgery
    • /
    • v.6 no.1
    • /
    • pp.7-14
    • /
    • 1973
  • Ventilatory functions and arterial respiratory gases were studied in 24 patients who underwent resectional surgery for pulmonary tuberculosis. Postoperative measurements were made 24 hours, 72 hours and 7 days after surgery and the results were compared to preoperative values. Twenty-four hours postoperatively, there occurred striking increase in respiratory rate, minute ventilation, dead space ventilation and dead space tidal volume ratio, and the increase in minute ventilation was caused primarily by the increase in respiratory rate. However, alveolar ventilation, oxygen consumption, carbon dioxide elimination and respiratory quotient showed no significant postoperative changes although two of the last values showed slight decreases 24 hours after surgery. The lowest arterial oxygen saturation level was obtained 24 hours postoperatively followed by gradual rises but not to the preoperative levels until 7 days after surgery. A decreased arterial carbon dioxide tension with elevated pit was noted 24 hours after surgery, which returned to the preoperative level on the following measurement.

  • PDF

A Numerical Study on the Turbulent Flow Characteristics Near Compression TDC is Four-Valve-Per-Cylinder Engine (4밸브기관의 압축상사점 부근의 난류특성에 관한 수치해석적 연구)

  • 김철수;최영돈
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.1 no.1
    • /
    • pp.1-13
    • /
    • 1993
  • The three-dimensional numerical analysis for in-cylinder flow of four-valve engine without intake port has been successfully computed. These computations have been performed using technique of the general coordinate transformation based on the finite-volume method and body-fitted non-orthogenal grids using staggered control volume and covariant variable as dependent one. Computations are started at intake valve opening and are carried through top-dead-center of compression. A k-$\varepsilon$model is used to represent turbulent transport of momentum. The principal study is the evolution of interaction between mean flow and turbulence and of the role of swirl and tumble in generating near TDC turbulence. Results for three different inlet flow configuration are presented. From these results, complex flow pattern may be effective for promoting combustion in spark-ignition engines and kinetic energy of mean flow near TDC is well converted into turbulent kinetic energy.

  • PDF