• Title/Summary/Keyword: De-icing Salt

Search Result 30, Processing Time 0.021 seconds

Growth and Physiological Response of Three Evergreen Shrubs to De-icing Salt(CaCl2) at Different Concentrations in Winter - Focusing on Euonymus japonica, Rhodoendron indicum, and Buxus koreana - (겨울철 염화칼슘(CaCl2) 처리에 따른 가로변 3가지 상록 관목류의 생육 및 생리반응 - 사철나무, 영산홍, 회양목을 중심으로 -)

  • Ju, Jin-Hee;Park, Ji-Yeon;Xu, Hui;Lee, Eun-Yeob;Hyun, Kyoung-Hak;Jung, Jong-Suk;Choi, Eun-Young;Yoon, Yong-Han
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.44 no.2
    • /
    • pp.122-129
    • /
    • 2016
  • It is important to know the sensitivity of shrubs to de-icing salt in order to set guidelines for ecological tolerance of evergreen shrubs along roads. Therefore, the aim of this study was to investigate the influence of de-icing salt, calcium chloride($CaCl_2$), on the growth and physiological characteristics of three evergreen shrubs, Euonymus japonica, Rhododendron indicum, and Buxus koreana. Plants were exposed to calcium chloride at different concentrations(weight percentage, 0% as control, 1.0%, 3.0%, and 5.0%) through amended soil maintained from the start of the experiment in October of 2014 until termination in March of 2015. The survival rate, plant height, leaf length, leaf width, leaf shape index, number of leaves, fresh weight, dry weight, dry matter, root/top ratio, chlorophyll contents, fluorescence, photosynthesis, stomatal conduct, and transpiration rate were recorded. Elevated calcium chloride concentrations decreased plant height, leaf length, leaf width, leaf shape index, fresh weight, dry weight, dry matter, and R/T ratio of the three shrubs. Root growth responded more sensitively than the top growth to salinity. However Euonymus japonica was more tolerant to salt stress than Rhododendron indicum and Buxus koreana. Their growths were totally inhibited by $CaCl_2$ above 3.0% and 1.0% concentrations, respectively. Chlorophyll content, fluorescence, photosynthesis, stomatal conduct, and transpiration rate of both Rhododendron indicum and Buxus koreana were reduced sharply, while Euonymus japonica exhibited mild reductions compared to plants grown in control when increasing calcium chloride was used. Especially, the transpiration rates of Rhododendron indicum, and the photosynthesis and stomatal conduct of Buxus koreana were suppressed as the concentrations of calcium chloride increased. Therefore, Euonymus japonica should be considered as an ecologically tolerant species with proven tolerance to de-icing salt.

Durability of Concrete Reinforced by Polypropylene Fivers (합성섬유보강 콘크리트의 내구특성)

  • 박제선;정영화;윤경구;이주형
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1999.04a
    • /
    • pp.449-454
    • /
    • 1999
  • Pavement concrete subjected to severe environmental condition may be vulnerable to frost attack practically where de-icing chemicals are used. This study focused on the investigation of durability characteristics of pavement concrete incorporation polypropylene fibers and application feasibility of these into the pavements of local roads and highway. A series of labortory tests were performed with main experimental variable such as fiber types, fiber contents. and type of concrete mix. The test of compressive strength was executed as primary tests, before the durability tests such as a scaling resistance were performed. De-icing salt resistance test was progressed by recycling freeze and thaw in the presence of a 4% calcium chloride solution. The deteriorated surfaces were rated by visual inspection and the loss weight were measured at every 5 cycles.

  • PDF

Penetration of De-icing Salt in Bare Concrete Bridge Decks on Highways (고속도로 콘크리트 노출 바닥판에서의 제설 염화물의 침투 특성)

  • Suh, Jin-Won;Rhee, Ji-Young;Ku, Bon-Sung
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.05b
    • /
    • pp.165-168
    • /
    • 2006
  • The major cause of deterioration for the bare concrete bridge decks exposed to de-icing chemicals would be chloride-induced reinforcement corrosion. Thus, in this paper, in order to predict time to corrode for concrete bridge decks on highways, the chloride concentration was measured with depth from the surface. Then, the surface chloride concentration and apparent diffusion coefficient were calculated by regression. The premature failure of bare concrete decks were mostly related with thin cover depth and poor concrete property(high permeability). The good protection of deck surface might contribute to the prolongation of the service life of bare concrete bridge decks.

  • PDF

An Experimental Study on the Improvement of Freezing-Thawing Resistance of Gutter Concrete (측구 콘크리트의 동결융해 저항성능 개선을 위한 실험적 연구)

  • Lee, Hoi-Keun;Sohn, Yu-Shin;Kim, Han-Jun;Lee, Seung-Hoon
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.11a
    • /
    • pp.577-580
    • /
    • 2006
  • This paper presents the experimental results of frost durability characteristics including freezing-thawing and de-icing salt scaling of the concrete used for gutter of the road. Mixtures were proportioned with the three level of water-binder ratio (W/B), 0.58, 0.53, and 0.48, and two binder compositions corresponding to Type I cement without any supplementary cementitious materials (OPC) and Type I cement with 30% blast-furnace slag replacement (Slag30). Also, two different solutions of calcium chloride and water that contains 0 and 8g of anhydrous calcium chloride in each 100 mL of solution, respectively, were used to evaluate their effect on the frost durability resistance. Test results showed that the Slag30 mixture exhibited higher durability factor and lower mass loss values than those made with OPC. Among the mixture tested in this work, the mixtures (OPC and Slag30) made with a relatively higher W/B of 0.58 exhibited large amount of the de-icing salt scaling regardless of calcium chloride concentration. Finally, the use of slag can be used effectively in terms of economy and frost durability of the concrete designated for gutter.

  • PDF

Synergistic Effects for Remediation of Salt-affected Soil using Dendranthema zawadskii var. latilobum and Soil Amendments under High-concentration Calcium Chloride (고농도 염화칼슘 농도처리에 따른 토양개량제와 구절초의 염분저감 상승효과)

  • Yoon, Yong-Han;Yang, Ji;Park, Je-Min;Ju, Jin-Hee
    • Journal of Environmental Science International
    • /
    • v.30 no.10
    • /
    • pp.803-809
    • /
    • 2021
  • This study aimed to investigate the effects of soil amendment (heat-expanded clay and active carbon) and planting of Dendranthema zawadskii var. latilobum on the remediation of salt-affected soil and the plant growth under high calcium chloride (CaCl2) concentration. The experimental group comprised treatments including Non treatment (Cont.), heat-expanded clay (H), active carbon (AC), planting (P), heat-expanded clay+planting (H+P), active carbon+planting (AC+P). A 200 mL solution of CaCl2 at a concentration of 10 g·L-1 was applied as irrigation once every 2 weeks. Compared to the Cont., the incorporation of the 'heat-expanded clay' amendment decreased electrical conductivity of the soil leachate and cation exchange capacity, whereas the growth of Dendranthema zawadskii var. latilobum was relatively increased. These results suggest that the combination of 'heat-expanded clay' amendment and planting will mitigate negative effect of de-icing salts and improve plant growth in salt-contaminated roadside soils.

A Study on the concrete pavement for early traffic opening day (콘크리트 도로포장의 조기개통에 관한 연구)

  • 임창덕;윤원곤
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1990.04a
    • /
    • pp.57-60
    • /
    • 1990
  • The purpose of this report is to study the traffic opening day of concrete pavement. For this purpose this paper studies on the propeties of various cement types which include the newly developed cement for the cement pavement regarding the resistance to the chemical attack caused by de-icing salt and the durability of the concrete pavement. Especially, traffic opening day of concrete pavement are discussed on site.

  • PDF

An Experimental Study on Evaluation Methods for Scaling Resistance of Cement Concrete Pavement (시멘트 콘크리트 포장의 스케일링 저항성 평가방법에 관한 실험적 연구)

  • Lee, Hyeon-Gi;Oh, Hong-Seob;Sim, Jong-Sung;Shim, Jae-Won
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.19 no.3
    • /
    • pp.30-38
    • /
    • 2015
  • In cold-climate regions, deicing agents is used for smooth traffic on the road due to freezing and snowdrift in winter. The use of de-icing salts has resulted in the accelerated scaling damage of concrete with salt damage under freezing and thawing condition. Scaling is the deterioration of concrete where in the paste-mortar structure delaminates in flakes from the surface of the concrete. Due to such damage, concrete pavement causes various problems such as early deterioration according to the decrease in the thickness of cover concrete and user's stability issues. Accordingly, various tests and evaluation methods have been suggested in order to evaluate these phenomena in other countries. However, there have been no regulations for the evaluation method in South Korea, and related studies are also very rare. Therefore, in this study, the evaluation methods proposed by each institution and country were investigated and the experiments were performed according to each regulation, followed by the comparison and analysis of the results. Furthermore, this study aims to suggest the optimized experimental method adopted to domestic field through the discussion of such experimental methods and results.

Growth of Dendranthema zawadskii in Chloride-containing De-icing Salt Areas Upon Treatment With Soil Amendments (제설제 피해지에서 토양개량제 처리에 따른 구절초의 생육특성 비교)

  • Ju, Jin-Hee;Yang, Ji;Park, Sun-Young;Yoon, Yong-Han
    • Journal of Environmental Science International
    • /
    • v.30 no.3
    • /
    • pp.235-243
    • /
    • 2021
  • This study was conducted to investigate the growth of Dendranthema zawadskii in damaged soils when they are treated with improvement agents. The treatments consisted of a control (unamended field soil) and the application of a loess ball of 1 cm to the field soil. According to the degree of damage the de-icing agent had caused, the soils were divided into 3 areas (based on the yellowing of Pinus densiflora for. multicaulis in soil surveys): H (high saline), M (medium saline), and L (low saline). A total of six treatments were performed: D. zawadskiia plant without soil amendment (H; high saline soil, M; medium saline soil, L; low saline soil), and a D. zawadskiia plant with loess ball on the soil surface (H.L; high saline soil with loess ball, M.L; medium saline soil with loess ball, L.L; low saline soil with loess ball). The results showed that D. zawadskiia growth went from highest to lowest in the order: M.L > L.L > M > L > H.L > H. Plant growth results showed that soils treated with soil amendments (loess ball) were better for D. zawadskii growth than untreated soils.

Scaling Resistance of Cement Concrete Incorporating Mineral Admixtures (광물질혼화재를 적용한 콘크리트의 스케일링 저항성 평가)

  • Lee, Seung-Tae;Park, Se-Ho
    • International Journal of Highway Engineering
    • /
    • v.17 no.2
    • /
    • pp.47-53
    • /
    • 2015
  • PURPOSES: The scaling of a concrete surface caused by the combined effects of frost and de-icing salts is one of the main reasons for the need to repair transportation infrastructures in cold-climate regions. This study describes the results of attempts to determine the scaling resistance of concrete incorporating mineral admixtures such as fly ash, GGBFS, and silica fume, and subjected to the actions of frost and salt. METHODS : Conventionally, to evaluate the fundamental properties of concrete, flexural and compressive strength measurements are regularly performed. Based on the ASTM C 672 standard, concrete is subjected to 2%, 4%, and 8% $CaCl_2$ salt solutions along with repeated sets of 50 freeze/thaw cycles, and the scaling resistance was evaluated based on the mass of the scale and a visual examination. RESULTS : It was observed that silica fume is very effective in enhancing the scaling resistance of concrete. Meanwhile, concrete incorporating GGBFS exhibited poor resistance to scaling, especially in the first ten freeze/thaw cycles. However, fly ash concrete generally exhibited the maximum amount of damage as a result of the frost-salt attack, regardless of the concentrations of the solutions. CONCLUSIONS: It can be concluded that the scaling resistance of concrete is highly dependent on the type of the mineral admixture used in the concrete. Therefore, to provide a durable concrete pavement for use in cold-climate regions, the selection of a suitable binder is essential.

Frost resistance of porous concrete assuming actual environment (實環境を考慮したポーラスコンクリートの耐凍害性の評価(실제 환경을 고려한 다공질 콘크리트의 내동해성(耐凍害性) 평가))

  • NAKAMURA, Takuro;HORIGUCHI, Takashi;SHIMURA, Kazunori;SUGAWARA, Takashi
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2008.11a
    • /
    • pp.227-233
    • /
    • 2008
  • Porous concrete has large continuous voids of 20-30 % by volume, and this concrete is attractive as environmental material in Japan i.e. permeable road pavement, river bank protection with vegetation and green roof system which influence thermal environment. It is necessary to confirm the frost resistance when constructing porous concrete structure in cold region. However applicable test method and evaluation criterion of porous concrete has not defined yet. Therefore, the object of this study is to investigate the frost resistance of porous concrete and this investigation attempts to address this concern by comparing 4 kinds of specified freezing and thawing tests methods (JIS A1148 procedure A/B and RILEM CIF/CDF test) in consideration of actual environment. RILEM freeze-thaw tests are different from JIS A1148 freeze-thaw tests, which are widely adopted for evaluating the frost resistance of conventional concrete in Japan, in water absorption, cooling rate, length of freezing and thawing period, and number of freezing and thawing cycles. RILEM CIF test measures internal damage and is primarily applicable for pure frost attack. CDF test is appropriate for freeze-thaw and de-icing salt attack. JIS A1148 procedure A/B showed extremely low frost resistance of porous concrete if the large continuous voids were filled with water and the ice expansion in the large continuous voids set in during cooling. Frost resistance of porous concrete was improved by mixing coarse aggregate (G7) which particle size is smaller and fine aggregate in JIS freezing and thawing tests. RILEM CIF/CDF test showed that freeze-thaw and de-icing resistance of porous concrete was seems to be superior in that of conventional concrete.

  • PDF