• Title/Summary/Keyword: DcR3

Search Result 328, Processing Time 0.026 seconds

A Bidirectional Three-phase Push-pull Zero-Voltage Switching DC-DC Converter (양방향 3상 푸쉬풀 ZVS DC-DC 컨버터)

  • Kwon, Min-Ho;Han, Kook-In;Park, Jung-Sung;Choi, Se-Wan
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.18 no.4
    • /
    • pp.403-411
    • /
    • 2013
  • This paper proposes an isolated bidirectional three-phase push-pull dc-dc converter for high power application such as eco-friendly vehicles, renewable energy systems, energy storage systems, and solid-state transformers. The proposed converter achieves ZVS turn-on of all switches and volume of passive components is small by an effect of three-phase interleaving. The proposed converter has identical switching pattern for both boost and buck mode, and therefore can provide seamless characteristic at the mode transition. A 3kW prototype of the proposed converter has been built and tested to verify the validity of the proposed operation.

A study on the design of an accident prevention system using an acceleration sensor (가속도 센서를 이용한 사고방지 시스템 설계에 관한 연구)

  • Shin, Jin-Seob;Lee, Yun-Min
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.21 no.6
    • /
    • pp.135-140
    • /
    • 2021
  • In this paper is a study on system design to prevent accidents using accelerometers. A switching power FET was configured at the power supply stage, and DC-DC converter, a regulator, and an LDO were designed for the power supply. In order to solve the power problem at once, it was divided into two parts, and a 3-axis accelerometer was designed to extract motion information to safely prevent accidents. Microprocessor enables communication through I2C and UART communication ports, and enables debugging through J-LINK. As a result of measuring the acceleration sensor data, it was confirmed that the power is normally cut off to prevent accidents when motion at an angle of 30° or more is detected.

DC-Link Voltage Ripple Analysis of Minimum Loss Discontinuous PWM Strategy in Two-Level Three-Phase Voltage Source Inverters (최소 손실 불연속 변조 기법에 따른 2레벨 3상 전압원 인버터의 직류단 전압 맥동 분석)

  • Lee, Junhyuk;Park, Jung-Wook
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.26 no.2
    • /
    • pp.120-126
    • /
    • 2021
  • DC-link capacitors are one of the main components in two-level three-phase voltage source inverters (VSIs); they provide the pulsating input current and stabilize the vacillating DC-link voltage. Ideally, the larger the capacitance of DC-link capacitors, the better the DC-link voltage stabilizes. However, high capacitance increases the cost and decreases the power density of VSI systems. Therefore, the capacitance should be chosen carefully on the basis of the DC-link voltage ripple requirement. However, the DC-link voltage ripple is dependent on the pulse-width modulation (PWM) strategy. This study especially presents a DC-link voltage ripple analysis when the minimum loss discontinuous PWM strategy is applied. Furthermore, an equation for the selection of the minimum capacitance of DC-link capacitors is proposed. Experimental results with R-L loads are also provided to verify the effectiveness of the presented analysis.

Automated Analysis for PDC-R Technique by Multiple Filtering (다중필터링에 의한 PDC-R 기법의 자동화 해석)

  • Joh, Sung-Ho;Rahman, Norinah Abd;Hassanul, Raja
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.30 no.3C
    • /
    • pp.141-148
    • /
    • 2010
  • Electrical noises like self potential, burst noises and 60-Hz electrical noises are one of the causes to reduce reliability of electrical resistivity survey. Even the PDC-R (Pseudo DC resisitivity) technique, recently developed, is suffering from the problem of low reliability due to electrical noises. That is, both DC-based and AC-based resistivity technique is subject to reliability problem due to electrical noises embedded in urban geotechnical sites. In this research, a new technique to enhance reliability of the PDC-R technique by minimizing influence of electrical noises was proposed. In addition, an automated procedure was also proposed to facilitate data analysis and interpretation of PDC-R measurements. The proposed technique is composed of two steps: 1. to extract information only related with the input current by means of multiple-filter technique, and 2. to undertake a task to sort out signal information only to show stable and reliable characteristics. This automated procedure was verified by a synthetic harmonic wave including DC shift, burst random noises and 60-Hz electrical noises. Also the procedure was applied to site investigation at urban areas for proving its feasibility and accuracy.

A Non-isolated DC-DC Converter with High Step-up Ratio and Wide ZVS Range (고승압비와 넓은 ZVS 영역을 갖는 비절연 DC-DC 컨버터)

  • Park, Sung-Sik;Kim, Pyo-Soo;Choi, Se-Wan;Lee, Jin-Hee
    • Proceedings of the KIPE Conference
    • /
    • 2008.06a
    • /
    • pp.203-205
    • /
    • 2008
  • 기존의 부스트 컨버터에서는 출력 전압이 커질수록 스위치의 전압 및 전류스트레스가 커지고 다이오드 역방향회복에 의한 서지로 인해 실제 사용 가능한 승압비가 제한된다. 본 논문에서는 높은 승압을 요구하는 대전력 응용에도 적합한 새로운 비절연 DC-DC 컨버터를 제안한다. 제안한 컨버터는 듀티비 0.5로 약 6배의 승압비를 가지며 CCM에서도 영전압 스위칭이 가능하다. 또한 스위치 및 다이오드 전압정격이 출력전압의 1/3로 되고 인터리빙이 가능하여 입출력 수동소자의 정격도 작다. 다이오드도 ZCS 턴오프 동작으로 역방향 회복에 의한 서지가 없다. 제안하는 컨버터의 동작원리를 설명하였고 이론적 해석과 시뮬레이션 및 실험파형을 통해 타당성을 검증하였다.

  • PDF

Cryo-Compression Therapy After Elective Spinal Surgery for Pain Management: A Cross-Sectional Study With Historical Control

  • Nabiyev, Vugar Nabi;Ayhan, Selim;Adhikari, Prashant;Cetin, Engin;Palaoglu, Selcuk;Acaroglu, R. Emre
    • Neurospine
    • /
    • v.15 no.4
    • /
    • pp.348-352
    • /
    • 2018
  • Objective: Postoperative dynamic cryo-compression (DC) therapy has been proposed as a method of reducing pain and the inflammatory response in the early postoperative period after orthopedic joint reconstruction surgery. Our aim was to analyze the analgesic efficacy of DC therapy after adult lumbar spinal surgery. Methods: DC was applied for 30 minutes every 6 hours after surgery. Pain was measured by a visual analogue scale (VAS) in the preoperative period, immediately after surgery, and every 6 hours postoperatively for the first 72 hours of the hospital stay. Patients' pain medication requirements were monitored using the patient-controlled analgesia system and patient charts. Twenty patients who received DC therapy were compared to 20 historical controls who were matched for demographic and surgical variables. Results: In the postanesthesia care unit, the mean VAS back pain score was $5.87{\pm}0.9$ in the DC group and $6.95{\pm}1.0$ (p=0.001) in the control group. The corresponding mean VAS scores for the DC vs. control groups were $3.8{\pm}1.1$ vs. $5.4{\pm}0.7$ (p < 0.001) at 6 hours postoperatively, and $2.7{\pm}0.7$ vs. $6.25{\pm}0.9$ (p<0.001) at discharge, respectively. The cumulative mean analgesic consumption of paracetamol, tenoxicam, and tramadol in the DC group vs. control group was $3,733.3{\pm}562.7mg$ vs. $4,633.3{\pm}693.5mg$ (p<0.005), $53.3{\pm}19.5mg$ vs. $85.3{\pm}33.4mg$ (p<0.005), and $63.3{\pm}83.4mg$ vs. $393.3{\pm}79.9mg$ (p<0.0001), respectively. Conclusion: The results of this study demonstrated a positive association between the use of DC therapy and accelerated improvement in patients during early rehabilitation after adult spine surgery compared to patients who were treated with painkillers only.

Optimal Soft-Switching Scheme for Bidirectional DC-DC Converters with Auxiliary Circuit

  • Lee, Han Rim;Park, Jin-Hyuk;Lee, Kyo-Beum
    • Journal of Power Electronics
    • /
    • v.18 no.3
    • /
    • pp.681-693
    • /
    • 2018
  • This paper proposes a soft-switching bidirectional dc-dc converter (BDC) with an auxiliary circuit. The proposed BDC can achieve the zero-voltage switching (ZVS) using an auxiliary circuit in the buck and boost operations. The auxiliary circuit supplies optimal energy for the ZVS operation of the main switches. The auxiliary circuit consists of a resonant inductor, a back-to-back switch and two capacitors. A small-sized resonant inductor and an auxiliary switch with a low-rated voltage can be used in the auxiliary circuit. Zero-current switching (ZCS) turn-on and turn-off of the auxiliary switches are possible. The proposed soft-switching scheme has a look-up table for optimal switching of the auxiliary switches. The proposed strategy properly adjusts the turn-on time of the auxiliary switch according to the load current. The proposed BDC is verified by the results of PSIM simulations and experiments on a 3-kW ZVS BDC system.

Characterization of step-edge dc SQUID magnetometer fabricated on sapphire substrate (사파이어 기판 위에 제작된 step-edge dc SQUID magnetometer의 특성)

  • 임해용;박종혁;정구락;한택상;김인선;박용기
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2002.02a
    • /
    • pp.127-130
    • /
    • 2002
  • Step-edge dc SQUID magnetometers have been fabricated on sapphire substrate. Ce$O_{2}$ buffer layer and $YBa_{2}$$Cu_{3}$ $O_{7}$(YBCO) films were deposited in-situ on the low angle (~$35^{\circ}$)steps formed on the substrates. Typical 5-$\mu$m-wide junction has $R_{N}$ of 4 $\Omega$ and $I_{c}$ of 60 $\mu$A with $I_{c}$$R_{N}$ product of 240 $\mu$V at 77 K. According to applied bias current, depth of voltage modulation was changed and maximum voltage was measured 100~300 fT/$\checkmark$ Hz at 100 Hz, and about 1.5 pT/$\checkmark$ Hz at 1 Hz. For ac bias reversal method, field noise was decreased in the 1/f region. The QRS peak of magneto-cardiogram was measured 50 pT in the magnetically shielded room.

  • PDF

A Study on the Selection of Lightning Arrester for DC Electric Traction Vehicles (전기철도용 피뢰기 선정에 관한 연구)

  • Kil, G.S.;Song, J.Y.;Kim, I.L.;Moon, S.B.;Han, J.S.
    • Proceedings of the KSR Conference
    • /
    • 2006.11b
    • /
    • pp.581-586
    • /
    • 2006
  • Selection and application recommendations of lightning arresters for DC electric traction vehicles are presented. To decide arrester specification such as continuous operating voltage(COV, $U_c$), rated voltage($U_R$), and nominal discharge current($I_n$), variations of system voltage and surge currents flowing arresters were analyzed in running-service of traction vehicles. System voltages increased up to 1,800V during anti-breaking. Surge currents recorded 3 times per running-service-route and their magnitudes were ranges of $150A{\sim}2kA$. From the field measurement and consideration of EN50163, COV, $U_c$, and $U_R$ for the $1,500V_{DC}$ traction vehicles were proposed.

  • PDF

Characteristics of the dietary intake of Korean elderly by chewing ability using data from the Korea National Health and Nutrition Examination Survey 2007-2010 (한국 노인의 저작능력에 따른 식품 및 음식섭취 특성: 2007~2010년 국민건강영양조사 자료에 근거하여)

  • Park, Ji Eun;An, Hee Jung;Jung, Sung Ug;Lee, Yoonna;Kim, Cho-Il;Jang, Young Ai
    • Journal of Nutrition and Health
    • /
    • v.46 no.3
    • /
    • pp.285-295
    • /
    • 2013
  • The purpose of this study was to examine the characteristics of the dietary intake of Korean elderly according to chew-ing ability using data from the Korea National Health and Nutrition Examination Survey (KNHANES) conducted during 2007-2010. Among subjects aged 65 years and over, more than half, 54.3% of elderly people, were classified as the difficulty in chewing group (DC). The DC group had lower nutrients and food intakes than those of in the no difficulty in chewing group (NDC). Findings showed that subjects in the DC group consumed fewer foods, especially fruits and vegetables. In addition, the DC group had significantly lower intakes of pan-fried food, stir-fried food, braised food, and seasoned-cooked vegetables, which could not be easily cooked or chewed. On the other hand, the number of soups and stews included in the top 30 largely consumed dishes were higher in the DC group than in the NDC group. No difference in numbers of daily meal/snack intake was observed between the two groups, however, the DC group had lower numbers of side-dishes compared to the NDC group. Fewer side-dishes per meal could be related to lower intakes of nutrients in dietary quality. Findings of this study demonstrated that dietary intake was influenced by chewing ability of elderly Korean people. Therefore, study of factors affecting dietary intake such as convenient cooking methods to decrease cooking time and skills to extend preservation and storage time of foods will necessary. In addition, development of food products and new techniques of cooking considering health status, chewing, and swallowing ability is required for the elderly, followed by establishment of standards for senior-friendly food products.