• Title/Summary/Keyword: Dc-link current

Search Result 511, Processing Time 0.026 seconds

Optimal Design for Hybrid Active Power Filter Using Particle Swarm Optimization

  • Alloui, Nada;Fetha, Cherif
    • Transactions on Electrical and Electronic Materials
    • /
    • v.18 no.3
    • /
    • pp.129-135
    • /
    • 2017
  • This paper introduces a design and a simulation of a hybrid active power filter (HAPF) for harmonics reduction given an ideal supply source. The synchronous reference frame method has been used here to identify the reference currents. The proposed HAPF uses a new artificial- intelligence technique called Particle Swarm Optimization (PSO) for tuning the parameters of a proportional and integral controller called PI-PSO. The PI-PSO controller is used to archive optimality for the DC-link voltage of the HAPF-inverter. The hysteresis non-linear current control method is used in this approach to compare the extracted reference and the actual currents in order to generate the pulse gate required for the HAPF. Results obtained by simulations with Matlab/Simuling show that the proposed approach is very flexible and effective for eliminating harmonic currents generated by the non-linear load with the HAPF based PSO tuning.

Optimal Design of the LLC HB Resonant Converter for Notebook Computer Adapter (노트북 컴퓨터 어댑터용 LLC 하프 브리지 공진형 컨버터 최적설계)

  • Yoo, Byoung-Seon;Kim, Chang-Sun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.8
    • /
    • pp.1418-1423
    • /
    • 2007
  • The topology of LLC half bridge resonant converter provides ZVS characteristic. The voltage stress and current stress are smaller than that of the general resonant converters. So the LLC HB resonant converter can be considered as a optimal circuit for the notebook computer adapter. In the adapter design, we should consider the weight, the size and the overheat of the adapter. Thus the higher efficiency is an essential particular. First of all, the optimal design of transformer is the most important facts. Some parameters should be considered in order to get the highest efficiency. The adapter is designed through the considering of these parameters including the PFC circuit as the pre-regulator. It converts AC line input into about DC 390V link voltage of the LLC HB converter input and the converter has 16V/90W ratings. The efficiency measured is about up to 93%.

A Control Algorithm Design for 45kVA UPQC Prototype (45kVA UPQC 제어 알고리즘 설계)

  • Jeon, Jin-Hong;Kim, Tae-Jin;Ryoo, Hong-Je;Ahn, Jong-Bo
    • Proceedings of the KIEE Conference
    • /
    • 2005.07b
    • /
    • pp.1483-1485
    • /
    • 2005
  • In recent years, customers and power supplies are interested in power quality. Demands of customers are change from standard quality of distribution power system to various high quality of distribution power system. so, it is necessary to apply power quality compensator. in our project, we develop the UPQC(Unfied Power Quality Compensator of 45kVA which compensates power factor and voltage sag, interruption. it is very frequently occurred power quality problems. As a series and shunt compensator, UPQC consists of two inverters with common dc link capacitor bank. It compensates the current quality in the shunt part and the voltage quality in the series part. In this paper, we present simulation and test result of developed UPQC system. Test for UPQC are performed at voltage sag, flickers and non-linear load conditions. For voltage sag and ficker generation, we use RTDS(Real Time Digital Simulator) and power amplifier system.

  • PDF

A Fault Tolerant Strategy Based on Model Predictive Control for Full Bidirectional Switches Indirect Matrix Converter

  • Le, Van-Tien;Lee, Hong-Hee
    • Proceedings of the KIPE Conference
    • /
    • 2019.07a
    • /
    • pp.74-76
    • /
    • 2019
  • This paper proposes an open-switch fault tolerant strategy based on the model predictive control for a full bidirectional switches indirect matrix converter (FBS-IMC). Compared to the conventional Indirect Matrix Converter (IMC), the FBS-IMC can provide healthy current path when open-switch fault is occurred. To keep the continuous operation, the fault tolerant strategy is developed by means of reversing the DC-link voltage polarity regardless of the faulty switch location in the rectifier or inverter stage. Therefore, the proposed control strategy can maintain the same input and output performances during the faulty condition as the normal condition. The simulation results are given to verify the effectiveness of the proposed strategy.

  • PDF

Simple On-line Elimination Strategy of Dead Time and Nonlinearity in Inverter-fed IPMSM Drive Using Current Slope Information (IPMSM 드라이브에서 전류 기울기 정보를 이용한 데드타임 및 인버터 비선형성 효과의 간단한 제거 기법)

  • Park, Dong-Min;Kim, Myung-Bok;Kim, Kyeong-Hwa
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.17 no.5
    • /
    • pp.401-408
    • /
    • 2012
  • A simple on-line elimination strategy of the dead time and inverter nonlinearity using the current slope information is presented for a PWM inverter-fed IPMSM (Interior Permanent Magnet Synchronous Motor) drive. In a PWM inverter-fed IPMSM drive, a dead time is inserted to prevent a breakdown of switching device. This distorts the inverter output voltage, resulting in a current distortion and torque ripple. In addition to the dead time, inverter nonlinearity exists in switching devices of the PWM inverter, which is generally dependent on operating conditions such as the temperature, DC link voltage, and current. The proposed scheme is based on the fact that the d-axis current ripple is mainly caused by the dead time and inverter nonlinearity. To eliminate such an influence, the current slope information is determined. The obtained current slope information is processed by the PI controller to estimate the disturbance caused by the dead time and inverter nonlinearity. The overall system is implemented using DSP TMS320F28335 and the validity of the proposed algorithm is verified through the simulation and experiments. Without requiring any additional hardware, the proposed scheme can effectively eliminate the dead time and inverter nonlinearity even in the presence of the parameter uncertainty.

Improved instantaneous Following Control Function for High Power Factor PWM Matrix Converter (고역율 PWM 매트릭스 컨버터의 개선된 순시추종 제어함수)

  • Kim, Kwang-Tae
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.3
    • /
    • pp.35-43
    • /
    • 2005
  • Matrix converters have been studied for eliminating dc link of conventional converter-inverter system, and various undulation strategy have been proposed. Therefore, matrix converter have no energy storage component except for small ac later for the elimination of switching ripple, and can be made compact and highly reliable compare with the do link inverter system. Matrix converter, however, directly connected the input and the output terminals by bidirectional static switch. As a result if the input voltage are asymmetrical, and contain harmonics, the influence of the distortions directly appear on the output terminal. This problem is a major obstacle to the matrix converter. A new control method using average comparison strategy have been proposed in this paper. This control method realizes sinusoidal input and output current unity input displacement factor regardless of load power factor. Moreover, compensation of the asymmetrical and/or harmonic containing input voltage is automatically realized, and calculation time of control function is reduced.

Implemention of a DTIF Controller for Robust Drive of a 3 Phase Induction Motor in High-Speed Elevator (고속 엘리베이터에서 3상 유도전동기의 강건한 구동을 위한 DTIF 제어기의 구현)

  • 김동진;강창수;한완옥
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.9 no.3
    • /
    • pp.88-96
    • /
    • 1995
  • High speed elevator requires precise drive included in zero speed at start/stop drive for the high stability and controllability. The vector control techniques, which have been used for the precise operation of induction motor, can be divided into two classes; The indirect vector control by slip frequency and the direct vector control by field orientation. The existing direct vector control technique has a robustness against the change of motor parameter and the existing indirect vector control technique has a strength of control ability in the wide speed range comparatively. This study presents the DTIF (Direct Torque Indirect Flux) controller which has robust movement in the transition state and in about zero and low speed using the control technique in which torque is controlled by the direct vector technique and flux is controled by indirect vector technique. The proposed system is verified by simulation and experiment for driving 3 phase induction motor. The process of transition which is from about zero speed and low speed to high speed is compared and measured to specification of phase voltage, phase current and DC link current. It is verified that DTIF controller show robust and stable speed variation.

  • PDF

Parallel Operation of Voltage Source Inverters by Using Stator Windings of High Power Three-Phase Induction Motors (대전력 3상 유도전동기의 고정자권선을 이용한 전압원 인버터의 병렬운전)

  • 김인동;노의철;전성즙
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.8 no.4
    • /
    • pp.815-820
    • /
    • 2004
  • The parallel operation of voltage source inverters using stator windings of high power three-phase induction motors was proposed in this paper. Most current high power induction motors with more than 4 electric poles have their external terminals installed so that windings of each phase can be approached from the outside. High power induction motors can be driven by parallel-operating several voltage source inverters through these external terminals. This way, in case a certain inverter breaks down, the operation torque will get decreased but the system can maintain its operation with the other inverters, so it can cope more effectively with breakdowns. Moreover, by providing phase difference to the switching movements of each inverter, it can increase equivalent switching frequency, which helps achieve good characteristics such as the reduction in the ripple of output torque, the reduction in the ripple of input current, and the reduction in the size of DC capacitors. Besides, since power is divided into each inverter, it can also decrease the ifluence of EMI occurring in the system. The characteristics of the proposed method were proved through computer simulations in this paper.

Observation and Compensation of Voltage Distortion of PWM VSI for PMSM using Adaptive Control Method (영구자석 동기전동기 구동을 위한 전압원 인버터의 적응제어기법을 이용한 전압 왜곡 관측 및 보상)

  • Kim Hag-Wone;Youn Myung-Joong;Kim Hyun-Soo;Cho Kwan-Youl
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.10 no.1
    • /
    • pp.52-60
    • /
    • 2005
  • Generally, a voltage difference or voltage distortion exists between the reference voltage and the practical voltage applied to a motor in a pulse width modulated(PWM) voltage source inverter(VSI). This voltage distortion varies with the operating conditions such as the temperature, DC link voltage, and phase current level. Also the voltage distortion affects the machine current distortion, torque pulsations, and control performance. In this paper, the voltage distortion in a PWM VSI is analyzed and a new on-line estimation method based on the model reference adaptive system(MRAS) is proposed to compensate the time varying voltage distortion, while considering the parameter variations for a permanent magnet synchronous motor (PMSM). The simulation and experimental results show the effectiveness of the proposed voltage difference observer and the compensation method.

Sensorless vector control for super-high speed PMSM drive

  • Bae Bon-Ho;Sul Seung-Ki;Kwon Jeong-Hyeck;Shin Jong-Sub
    • Proceedings of the KIPE Conference
    • /
    • 2001.10a
    • /
    • pp.773-778
    • /
    • 2001
  • This paper describes the implementation of the vector control schemes for a variable-speed 131kW PMSM (Permanent Magnet Synchronous Motor) in super-high speed application. The vector control with synchronous reference frame current regulator has been implemented with the challenging requirements such as the extremely low stator inductance$(28^{\mu}H)$, the high dc link voltage(600V) and the high excitation frequency(1.2kHz). Because the conventional position sensor is not reliable in super-high speed, a vector control scheme without any position sensor has been proposed. The proposed sensorless algorithm is implemented by processing the output voltage of the PI current regulator, and hence the structure is simple and the estimated speed is robust to the measurement noise. The experimental system has been built and the proposed control has been implemented and evaluated. The test result, up to the speed of 60,000 r/min, shows the validity of the proposed control.

  • PDF