• Title/Summary/Keyword: Daylight Simulation

Search Result 73, Processing Time 0.018 seconds

Methodological study on the High Dynamic Range Imaging Processing (채광·조명설비시스템의 광학 분석을 위한 이미지 프로세싱 기법에 관한 연구)

  • Lim, Hong Soo;Kim, Gon
    • KIEAE Journal
    • /
    • v.10 no.4
    • /
    • pp.3-8
    • /
    • 2010
  • Recently, various daylight evaluation methods for visual environment have been developed; simulation analysis methods, numerical calculation, and data monitoring methods. However, it is impossible for simulation analysis to make real scenes and visualize real images exactly. Also, a numerical calculation is considered as an out of date and time-consuming mean. Therefore, for acquisition of accurate results, many studies often use the monitoring data methods. Especially, most studies regarding discomfort glare are evaluated by measuring the physical quantity of luminance through traditional measuring Minolta Luminance meters as an instrument. But, this method has a difficulty in measuring several points at the same time because of the limitation of spaces and time when mapping. So, this study focused on the potential usefulness of High Dynamic Range photography technique as a luminance mapping tool. In order to evaluate the accuracy of proposed programs such as webHDR, Photomatix and PHOTOLUX, this paper has conducted an experiment by using Canon EOS 5D and NICON Coolpix8400 digital camera.

A Comparative Evaluation of Daylighting Performance Software : Lumen-Micro, Adeline and Lightscape (채광성능 평가용 시뮬레이션 프로그램의 비교분석)

  • Kim, J.T.;Chung, Y.G.;Moon, G.H.
    • Journal of the Korean Solar Energy Society
    • /
    • v.23 no.1
    • /
    • pp.48-56
    • /
    • 2003
  • Three of the leading computer daylighting simulation programs are compared with physical modeling techniques as a means of predicting daylighting performance of interior spaces. Lumen-Micro, Adeline and Lightscape are compared with physical model experiments under clear sky conditions. The comparative evaluations are conducted on analysis of daylight illuminance ratio(%) depending on model types. The estimated average errors are analyzed on 9.4% in Lumen-Micro, 6.3% in Adeline and 3.4% in Lightscape. Therefore, it is proved that three programs are useful for evaluating daylighting performance in our clear sky condition.

A Correlation Analysis between DSC (Dye Sensitized Cell) and Daylighting-Focusing on Educational Space (염료감응형 태양전지(DSC)와 자연채광의 상관관계 분석-교육공간을 중심으로)

  • Lee, Eung-Jik
    • Journal of the Korean Solar Energy Society
    • /
    • v.40 no.1
    • /
    • pp.35-47
    • /
    • 2020
  • Due to the large window area, the lighting environment of the educational space between the window and deep part of the room is not uniformly illuminated, and the phenomenon of glare is severe. For this reason, the daylight performance of DSC-BIPV windows was analyzed in order to improve the natural lighting in the educational sector. The method derives the correlation with natural lighting by measurement and simulation. Dynamic simulation confirmed that the average illuminance of the target space was higher at later than the early afternoon. The performance of natural lighting at 40% and 30% transmission of DSC has the effect of significantly reducing the amount of excess light in existing windows. Nevertheless, the actual average illuminance in all seasons corresponds to the standard illuminance of the educational facility, 300 Lux. In addition, the uniformity is also seen through the skylight illuminance ratio.

Analysis of Window Transmittance Using Horizontal Blind by RADIANCE Program (RADIANCE 프로그램에 의한 창문 블라인드의 투과율 분석 연구)

  • 정근영;최안섭
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.17 no.6
    • /
    • pp.7-15
    • /
    • 2003
  • The purpose of this simulation study is to determine the window transmittance by RADIANCE lighting simulation tool where the horizontal blind is installed. Parameters such as sky types, seasonal changes, altitude, azimuth, and horizontal blind angle at a 0$^{\circ}$, 45$^{\circ}$, 90$^{\circ}$ were considered. The simulation results present that measured directional transmittances have different values according to each directional property of the horizontal blind. In addition, methodology was described to apply window transmittance data to DayDim program which is a lighting calculation and analysis tool especially for the performance of daylight responsive dimming systems.

A Study on Improving Brightness Values for Real Representations of Material Images in Lightscape (Lightscape에서의 사실적 재질 이미지 표현을 위한 Brightness 수치 개선에 관한 연구)

  • Chang, Jun-Ho;Park, Ji-Ae;Choi, An-Seop
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.2
    • /
    • pp.1-8
    • /
    • 2007
  • This study is to generate optimal values of brightness and achieve more realistic images by varying such values according to individual materials in order to create better quality simulation images using Lightscape. Because there are discolorations of materials by adding the radiation of luminaires to that of daylight during the daytime, when low brightness values are inputted in case of daytime, the results are founded that images of materials can be seen much similar with real images. And in most of the materials, when low values in the daytime and high values in the nighttime are inputted this study verifies that the realest simulation images can be obtained using Lightscape, because the RGB data of simulation images are almost similar with that of real materials.

The Glass Greenhouse's Lighting Simulation for Ginseng with Solar Cell and LED (태양전지와 LED를 이용한 인삼재배용 유리온실의 조도 시뮬레이션)

  • Lee, Boong-Joo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.2
    • /
    • pp.14-19
    • /
    • 2019
  • In this study, the Relux illumination program was used to simulate the optimal lighting design for a glass greenhouse with Si and DSSC solar-cells and LEDs. The results of the daylight simulation show that the optimum conditions were a structure angle of 90o and higher transmittance. The results of the illumination simulation produced a power consumption effect of 5.6 kwh in the summer (42[%] energy savings compared to full LED control) and 7.8 kwh in the winter (58[%] energy savings compared to full LED control). The results suggest that ginseng should be grown in an energy-saving glass greenhouse.

Illumination simulation for selective application and energy saving of solar cells in single-span glass greenhouse (단동식 유리온실에서 태양전지의 선별적 적용과 에너지 절감에 관한 조도 시뮬레이션)

  • Jung, Hai-Young;Lee, Boong-Joo
    • Journal of IKEEE
    • /
    • v.23 no.4
    • /
    • pp.1448-1456
    • /
    • 2019
  • In this study, when applying LED light sources within a single-span glass greenhouse for growing crops, the illumination simulation was performed on the ceiling and side of the glass greenhouse to determine the selective placement and effective light transmission of Si series solar cells and dye-sensitive solar cells (DSSC) for supplying LED power source. In addition, energy saving effects of glass greenhouses were analyzed for optimum lighting control when both daylight and LED light sources are considered in glass greenhouses.

Study of Improving the Biotope Area Ratio System for Urban Agriculture Vitalization - Focus on Daylight Condition Analysis- (도시농업 활성화를 위한 생태면적률 제도개선에 관한 연구 -단지내 일조조건 분석을 중심으로-)

  • Lee, Gunwon;Jeong, Yunnam;Min, Byunghak;Kim, Seiyong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.12
    • /
    • pp.7393-7402
    • /
    • 2014
  • This study focused on improving the Biotope Area Ratio, which has existing availability as a legal and institutional method for the architectural and urban fields to respond rapidly to recently growing demands for urban agriculture. The existing Biotope Area Ratio indicators only considers the depth and permeability of soil among a range of conditions for plant growth; they can be used for landscaping plants management but have difficulties in dealing with plants that are the major factors in urban agriculture. This study aimed to verify this hypothesis and suggest a direction of improvement in the Biotope Area Ratio. The study discovered that the management of plant growth only using the Biotope Area Ratio indicators has limitations.

Light Pollution of Outdoor Lighting in Coastal Area - Focused on Busan City - (해안가 야간경관조명의 빛공해 평가 - 부산시를 중심으로 -)

  • Kong, Hyo-Joo;Kim, Jeong-Tai
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.6
    • /
    • pp.18-26
    • /
    • 2010
  • Outdoor lighting has become a necessary essential part of society for safety and comfortable space. However, inappropriate outdoor lighting leads to energy waste and poor landscape. Outdoor lighting is a very important social element, which enables us to conduct various activities at night in a safe, efficient and comfort way. River Thames in UK, Venice in Italy and Sydney in Australia is a good example of the coastal area. This paper aims to evaluate the light pollution of outdoor lighting in coastal area in Busan city. The Radiant Imaging ProMetric-1400 was used to measure the luminance of Gwangalli Beach, Marine City and Haeundae Beach. Compare to the CIE recommendation level the luminance of the all outdoor lighting were about 2~20 times higher. Outdoor lighting of the building facade luminance level and color should be particularly limited.

A Study on the Effect of Envelope Factors on Cooling, Heating and Lighting Energy Consumption in Office Building (사무소 건물의 외피요소가 냉난방 및 조명에너지 소비에 미치는 영향에 관한 연구)

  • Son, Chang-Hee;Yang, In-Ho
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.2
    • /
    • pp.8-17
    • /
    • 2012
  • The objective of this study is to perform an analysis of the heat(heating and cooling) and lighting energy consumption according to the window area ratio and the application of horizontal louver, which is external shading device installed for the purpose of energy savings in office buildings. For this, a building was chosen as a typical example, and the heat and lighting energy consumption was calculated by using the daylight and building energy analysis simulation. The results showed that the total energy consumption, when the lighting control was applied, was reduced by an average of 11.49[%] compared to when there was no lighting control. The smaller the glazing ratio is, the less the total energy consumption is. Also, the application of the horizontal louver increases the total energy consumption under the same condition of glazing ratio.