• Title/Summary/Keyword: Day Lighting

Search Result 162, Processing Time 0.027 seconds

Effects of Low Dose $\gamma$ Radiation on Callus Growth of Lithospermum erythrorhizon S. (지치 (Lithospermum erythrorhizon S.) Callus 생장에 미치는 저선량 $\gamma$선의 효과)

  • 황혜연;김재성;이영복
    • Korean Journal of Plant Tissue Culture
    • /
    • v.28 no.6
    • /
    • pp.305-310
    • /
    • 2001
  • The effect of low dose ${\gamma}$-radiation on the callus growth of Lithospermum erythrorhizon S. cultured on different medium and lighting condition was investigated. The 8 Gy irradiation stimulated callus growth on LS medium supplemented with BA 2 mg/L and NAA 2 mg/L, however, the growth of callus was more effective on LS medium supplemented with BA 1 mg/L and NAA 1 mg/L under 16 hrs day light. And on the LS medium containing IAA 0.2 mg/L, 16 Gy irradiation increased the callus growth by supplement with kinetin 2 mg/1 and the effect of kinetin was higher than BA at same concentration. The growth of callus was more vigorous on LS medium than MS medium in general. On M-9 medium, the growth of callus was poor regardless lighting conditions, however, by ${\gamma}$-ray irradiation of 16 Gy or 30 Gy, callus growth rates were increased by 30% or more than 30%, especially, under 16 hrs day light condition.

  • PDF

A Study on Sky Light Pollution based on Sky Glow in Jeju Island (스카이글루 분석을 통한 제주도 빛공해 실태조사)

  • Lee, So-Hyun;Lim, Hong-Soo
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.34 no.4
    • /
    • pp.83-91
    • /
    • 2018
  • Artificial lighting contributes greatly to developing civilizations. It allows daytime activities to continue throughout the dark hours of the day and thus increasing work productivity as well as allowing people to enjoy nighttime activities. In addition, artificial lighting is used to beautify landscapes, architectural monuments, and thus highlighting the social-economic development of a given place. However, excessive and improper usage of artificial lighting can lead to light pollution. Light pollution is a serious issue that is detrimental to human health. It has been linked to a number of health conditions including sleep disorder, visual discomfort as well as cancer. The effects of light pollution extend throughout the entire ecosystem, affecting both plants and animals. Furthermore, sky-glow from light pollution hinders astronomical observation. The current paper presents a study conducted on lit environment of a nightscape. The quality of the sky was measured in 144 spots using Sky Quality Meter (SQM) devices. The measured spots were chosen on the basis of land use as well as distance from the Halla Mountain.

Subjective Evaluation on the Color Temperatures of LED illumination in the Classroom (학교 교실 LED 조명의 색온도에 대한 주관적 평가)

  • Jee, Soon-Duk;Kim, Chae-Bogk
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.1
    • /
    • pp.30-41
    • /
    • 2011
  • This study performs the subjective evaluations of LED illumination conditions according to three types of color temperatures (7,000[K], 5,000[K], 3,000[K]) after employing LED illumination system in the classroom, Since the objective of this study is to develop an artificial lighting conditions like day light comfortable to students in the classroom, the learning effect based on three types of LED illumination conditions are analyzed. Three factors (learning intention, learning environment, learning motivation) are extracted by ANOVA and there are preference differences of LED illumination conditions between learning intention and learning environment factors. Especially, preference differences of LED illumination conditions are existed about calculation, reading and fatigue reduction. The test results of this study can be applied to obtaining high achievement of learning based on the lighting conditions.

The State Estimator Design for Solar Lighting Controller (태양광 가로등 제어를 위한 상태추정기 설계)

  • Ma, Kang-Jin;Kim, Ji-Woong;Lhee, Chin-Gook;Kim, Hong-Gyu;Kim, Il-Song
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2009.05a
    • /
    • pp.168-171
    • /
    • 2009
  • The solar lighting system has been popular in these days. It is composed of solar panel, controller, and battery. The battery is charged during the day time, and discharged at the night time. The battery status should be carefully controlled in order to guarantee the safe operation. If there were measurement noise or system noise, the performance of controller could be degraded. In this paper, the state estimator design in the noisy environment is proposed. The proposed system shows the excellent tracking performance under in harsh conditions.

  • PDF

Development of Traffic Accident Models at Rural Signalized Intersections by Day and Night (지방부 신호교차로 주·야간 교통사고 예측모형 개발 및 비교 분석)

  • Lee, Geunhee;Jung, Sang Woon;Park, Minho;Lee, Dongmin;Roh, Jeonghyun
    • International Journal of Highway Engineering
    • /
    • v.17 no.3
    • /
    • pp.107-115
    • /
    • 2015
  • PURPOSES : The purposes of this study are to compare the day and night characteristics and to develop the models of traffic accidents. in Rural Signalized Intersections METHODS : To develop day and night traffic accident models using the Negative Binomial Model, which was constructed for 156 signalized intersections of rural areas, through field investigations and casualty data from the National Police Agency. RESULTS : Among a total of 17 variances, the daytime traffic accident estimate models identified a total of 9 influence factors of traffic accidents. In the case of nighttime traffic accident models, 11 influence factors of traffic accidents were identified. CONCLUSIONS : By comparing the two models, it was determined that the number of main roads was an independent factor for daytime accidents. For nighttime accidents, several factors were independently involved, including the number of entrances to sub-roads, whether left turn lanes existed in major roads, the distances of pedestrian crossings to main roads and sub-roads, lighting facilities, and others. It was apparent that if the same situation arises, the probability of an accident occurring at night is higher than during the day because the speed of travel through intersections in rural areas is somewhat higher at night than during the day.

Influence of Lighting Schedule and Nutrient Density in Broiler Chickens: Effect on Growth Performance, Carcass Traits and Meat Quality

  • Li, Wen-Bin;Guo, Yan-Li;Chen, Ji-Lan;Wang, Rong;He, Yao;Su, Dong-Ge
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.23 no.11
    • /
    • pp.1510-1518
    • /
    • 2010
  • The study was conducted to evaluate the effect of lighting schedule and nutrient density on growth performance, carcass traits and meat quality of broiler chickens. A total of 576 day old Arbor Acre male chickens was used with a $4{\times}2$ factorial arrangement. The four lighting schedules were continuous (23 L:1 D, CL), 20 L:4 D (12 L:2 D:8 L:2 D), 16 L:8 D (12 L:3 D:2 L:3 D: 2 L:2 D) and 12 L:12 D (9 L:3 D:1 L:3 D:1 L:3 D:1 L:3 D) and provided by incandescent bulbs. The two nutrient densities were high (H, starter diet: 13.39 MJ/kg apparent metabolisable energy (AME), 23.00% crude protein (CP); finisher diet: 13.39 MJ AME/kg, 19.70% CP) and low energy and protein level (L, starter diet: 12.03 MJ AME/kg, 20.80% CP; finisher diet: 12.14 MJ AME/kg, 18.30% CP). Houses with dark curtains and solid sidewalls were used. Chickens were randomly allocated to the 8 treatments with each treatment comprising 6 replicates of 12 chickens. Feed and water were available ad libitum. Lighting schedules showed no difference (p>0.05) in growth performance at the end of the experiment. 12 L:12 D significantly reduced (p<0.05) the concentration of malondialdehyde (MDA) compared to 23 L:1 D treatment. Intermittent lighting (IL) schedules produced higher protein content (p<0.001) in breast meat. Birds on high density diets had higher body weight (BW), feed intake (FI) (p<0.001), and feed conversion ratio (FCR) (p<0.001) throughout the experiment with the exception of 36 to 42 d. High nutrient density increased (p<0.05) abdominal fat, decreased (p<0.05) the moisture loss of meat, and reduced percentage of wings and legs. There was a significant lighting schedule${\times}$diet interaction (p<0.001) on FCR for days 8 to 14 and 15 to 21. Results indicated that IL can give similar growth performance in comparison with CL, meanwhile with positive effects on meat quality by increasing protein content and decreasing the concentration of MDA. High nutrient density resulted in greater growth performance.

Study of Modulation Effect in Integrated Interface Under Controlling Switching Light-Emitting Diode Lighting Module

  • Hong, Geun-Bin;Jang, Tae-Su;Kim, Yong-Kab
    • Transactions on Electrical and Electronic Materials
    • /
    • v.12 no.6
    • /
    • pp.253-257
    • /
    • 2011
  • This study was carried out to solve problems such as radio frequency band depletion, confusion risk, and security loss in existing visible wireless communication systems, and to determine the applicability of next-generation networks. A light-emitting diode (LED) light communication system was implemented with a controlling switching light module using the ATmega16 micro-controller. To solve the existing modulation effect and disturbance in visible light communication, an integrated interface was evaluated with a driving light module and analyzes its reception property. A transmitter/receiver using the ATmel's micro-controller, high-intensity white LED-6 modules, and infrared sensor KSM60WLM and visible sensor TSL250RD were designed. An experiment from the initial value of distance to 2.5 m showed 0.46 V of the voltage loss, and if in long distance, external light interference occurred and light intensity was lost by external impact and thus data had to be modified or reset repeatedly. Additionally, when we used 6 modules through the remote controller's lighting dimming, data could be transmitted up to 1.76 m without any errors during the day and up to 2.29 m at night with around 2~3% communication error. If a special optical filter can reduce as much external light as possible in the integrated interface, the LED for lighting communication systems may be applied in next generation networks.

A case study of life cycle cost analysis on high pressure sodium lamp and LED lamp for tunnel lighting (터널 조명 고압나트륨램프와 LED램프의 LCC 분석 사례 연구)

  • Lee, Gyu-Phil;Kim, Jeong-Heum
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.23 no.5
    • /
    • pp.315-323
    • /
    • 2021
  • Tunnel is the most energy-consuming structure in road due to the characteristic of using artificial lighting during day and night. Therefore, tunnel lights are being replaced by LED lamp that have advantages with respect to low power consumption. The best use of social overhead capital can be expected by considering the life cycle cost, because to tunnel structures are accompanied by a series of medium-to-long-term and continuous processes of replacing auxiliary facilities. In this study, the saving effect by LCC analysis was quantitatively analyzed by replacing tunnel light sources from high-pressure sodium lamps to LED lamps. The effect of reducing the replacement cycle by increasing the life of the lamps and the resulting maintenance cost is very significant, on replacing tunnel lighting light sources with LED lamp.

A Study on the Effect of inflow Daylight according to the installation method of controlling Light Shelf and Blind in the Room of General Hospital (종합병원 병실 내 광선반과 블라인드 설치 방식에 따른 자연채광 유입 효과 연구)

  • Cho, Ju Young;Lee, Hyo Won
    • KIEAE Journal
    • /
    • v.13 no.4
    • /
    • pp.3-10
    • /
    • 2013
  • This study aims to identify convenient surrounding of the hospital room to be improved by specifically focusing on light environment and to examine a change of inflow of the daylight in the hospital room by using blind and light shelf device as base data of preliminary research for comprehending the relationship between healing environment and natural day light. Simulation analysis on previous facilities and the installation of horizontal light shelf that derives the inflow of day light has been specifically referred by using ECOTECT2011 program. In case of C-facility that mostly adjoined to exterior spaces, it was shown to be closer to a proper uniformity factor when an angle was controlled on the light shelf with blind installed at the same time. However, it was not overall appropriate because of visual displeasure occurred from inflow of much day light. In conclusion, it is the form of flat surface such as H-facility that provides an effect after installing the device to derive day light. Especially, it was shown that interior day light environment was improved when installing blind and controlling the angle at the same time.