• Title/Summary/Keyword: Data-logger

Search Result 177, Processing Time 0.029 seconds

Visual spectral sensitivity of dark-adapted rockfish (Sebastes inermis) in LED light source (LED 광원에 대한 암순응시 볼락 (Sebastes inermis)의 시각 스펙트럼 민감도)

  • Heo, Min-A;Kang, Gyeong-Mi;Shin, Hyeon-Ok
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.51 no.1
    • /
    • pp.102-110
    • /
    • 2015
  • The characteristics of aquatic light fields are generally reflected in the visual systems of fishes inhabiting them. Therefore, research on light sensitivity of fish is useful to explain the correlation between the visual function and habitat, behavior and distribution of fish. Rockfish is an important species in coastal ecology and also one of the main species for culturing in Korea. To make a contribution on the maintenance of the fish resources and understanding the ecology of the rockfish, the visual spectral sensitivities of the dark-adapted rockfishes were measured in the range of visible light (405~660 nm) using a light source of light-emitting diodes (LEDs). In order to assess electrophysiological response of the fish, the ERGs (electroretinograms) of the dark-adapted rockfishes were recorded on a data logger (12 bits) and a laptop computer. Juvenile (n=5; weight: $20.3{\pm}5.2g$; total length: $10.3{\pm}0.7cm$) and adult (n=5; weight: $87.8{\pm}21.8g$; total length: $18.1{\pm}1.3cm$) rockfishes were used in experiment. The visual threshold of juvenile and adult rockfish were 11.66 (log quanta/$cm^2/s$) and 11.81 (log quanta/$cm^2/s$) in 574 nm, respectively. The peak wavelength of the spectral sensitivity in the dark-adapted juvenile and adult rockfish was commonly 551 nm (series of green color). Collectively, these results demonstrate that the rockfish has suitable visual capabilities for inhabiting coastal water in Korea.

Microclimate, Growth and Yield in Wheat under North-South and East-West Row Orientation (이랑방향에 따른 밀 군락의 미기상과 생육 및 수량)

  • Yoon, Seong-Tak;Jerry, Johnson
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.49 no.3
    • /
    • pp.155-159
    • /
    • 2004
  • This experiment was carried out to evaluate the microclimate of wheat canopy, growth and yield characteristics of wheat under north-south and east-west row orientation. The variety used in this experiment was "AG South 2000", which was developed in USA. Solar radiation, air temperature, relative humidity, and soil temperature were monitored by data logger from March to May in 2002, The ratio of light penetration to the bottom from the upper canopy was 36.8% in north-south and 21.4% in east-west row orientation. Temporal march of light penetration to the bottom from March to May decreased as wheat developed canopy structure and decreased a little from May as plant were matured. The highest light penetration to the bottom from upper canopy occurred at 13:00 in both north-south and east-west row orientations, respectively which were 36 times in north-south and 27 times in east-west row orientation, respectively. Daily maximum temperature at the bottom of canopy occurred at 14:00 with 29 times in north-south, while 19 times were obtained at 14:00 and 15:00, respectively in east-west row orientation. Relative humidity at the bottom of the canopy in east-west yow orientation showed higher than that of north-south row orientation. Occurrence of daily maximum soil temperature of north-south showed one hour later compared with east-west yow orientation. 1000 grain weight and test weight of north-south row orientation was higher than those of east-west vow orientation. Correlation coefficient between solar radiation of upper canopy and 1000 grain weight showed r=$0.8132^{*}$, and between air temperature of upper canopy and number of spikes per $\textrm{m}^{2}$ and 1000 grain weight showed significant positive correlation with r=$0.8139^{*}$, and r=$0.8293^{*}$, respectively.

Freezing and Deflection Characteristics of Flexible Pavement Structure Using Frost Model Test (동상모형실험을 통한 아스팔트 포장체의 동결 및 처짐 특성)

  • Shin, Eun-Chul;Hwang, Soon-Gab;Park, Jeong-Jun
    • Journal of the Korean Geosynthetics Society
    • /
    • v.11 no.3
    • /
    • pp.27-35
    • /
    • 2012
  • In this paper, the frost heaving and thawing characteristics of flexible pavement structure were evaluated in the large scale freezer which have a specification of temperature range $-20^{\circ}C{\sim}10^{\circ}C$ and $3.2m(L){\times}3.2m(B){\times}2.4m(H)$ in size. The insulated steel box with the size of $0.9m(L){\times}0.9m(B){\times}0.9m(H)$ was used to simulate actual pavement road structure. The variation of temperature, frost heave amount and frost heave pressure were measured through the instrument of TDS-602 data logger. LFWD (light falling weight deflectometer) was used to determine the change of deflection due to the frost heaving and thawing. Furthermore, the influence of aggregate layer to the freezing of the subgrade soil was studied to verify the function and effectiveness of the anti-freezing layer.

Application and verification analysis of the thermoelectric generation system for a coastal fishing vessel (열전발전 장치의 연안어선 활용에 관한 연구)

  • LEE, Donggil;YANG, Yongsu;KIM, Pyungkwan;KIM, Seonghun;KIM, Hyunyoung
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.53 no.2
    • /
    • pp.196-203
    • /
    • 2017
  • The renewable energy sources can be thought of one of the major measures to reduce greenhouse gas emissions in the industries. However, the utilization technology for those sources is approaching in the different matters. One of them, thermoelectric generation might be applicable to fishing industry. A various of internal combustion engines are used in a wide range of fisheries. After the ignition process, the heat passed out from the exhaust outlet. Recycling the heat could be not only an energy source but also reduction of green gas emission. Therefore, this study was designed to verify the feasibility of generation from wasted exhaust gas and analyze the performance. The designed experiment devices were connected with a data logger and an electric loader to quantify the currency and voltage. The devices were installed in a coastal fishing vessel for a gillnet fishery. During the whole fishing trips, the amount of generation was measured by engine rpm and the fishing operation procedures including vessel operations. At the maximum 1,500 rpm in the practical range, the generation amount was 113.6 W. The amount difference in relation to connection method was within 5 W: serial connection was 111.4 W and parallel connection was 115.8 W.

FBG Optical Fiber Sensors Embedded in Fiber Reinforced Polymer Composite Reinforcing Bars (철근대용 FRP 복합재에 삽입된 FBG 센서의 변형률에 관한 연구)

  • Kim, Myong-Se;Cho, Hyung-Sik;Cho, Sung-Kyu;Yoon, Jae-Jun;Baek, Hyun-Deok;Kim, Ki-Soo
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.27 no.2
    • /
    • pp.124-133
    • /
    • 2007
  • In our research, we focused on the FBG sensor system which is one of the fiber optic sensor system. The FBG sensor system is used for structural measurements. The problem of FBG sensor is very thin and weak. The methods that can protect FBG optical fiber sensor front outside forces such as the impacts are investigated. The FBG sensor embedded in the fiber reinforced composites which can replace the reinforcing steel bars in concretes can be applied to the concrete structures by embedding to the composite materials. The progresses in tensile strength of FBG sensor embedded in the reinforcing FRP bars in the concrete structures compare to plain FBGs were observed and the good long term durability is expected.

Return flow analysis of paddy field by water balance method (물수지분석 기법에 의한 논에서의 회귀율 조사분석)

  • 정상옥;손성호
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.43 no.2
    • /
    • pp.59-68
    • /
    • 2001
  • A water balance analysis was performed for a paddy field neighboring the Dongchang stream, downstream of the Unmun reservoir, which is constructed for the urban water supply. Daily rainfall data were collected and irrigation water flow rate, drainage flow rate, evaportranspiration, infiltration, and piezometeric head were measured in the field. The flow rates were continuously observed by water level logger during the growing season. The evaportranspiration and the infiltration were measured by N-type depletion meter and cylindrical infiltrometer, respectively. PVC pipes with 12mm diameter were used for piezometric head measurement. Total Irrigation and drainage flows were 3,608mm and 1,170mm in 1999, and 3,971mm and 1,548mm in 2000, respectively. The mean and range of the daily infiltration rate were 4.4mm/d and 3.4mm/d to 5.5mm/d in 1999 and 5.1mm/d and 4.1mm/d to 6.5mm/d in 2000, respectively. The net ground water flow including the change of soil water storage was 2,855mm in 1999 and 2,540mm in 2000. The evapotranspiration was 458.3mm in 1999 and 553.5mm in 2000. The range of daily evapotranspiration rate was from 1.6 to 8.7mm/d. The return flow ratio was about 32% in 1999 and 39% in 2000 and three year average was 35% including previous study in 1997. The amount of irrigation water was much higher than design standards or references in this study, This was caused by the inadequate water management practice in the area where water was oversupplied on farmers’ request rather than following sound water management principles.

  • PDF

Detecting of Periodic Fasciculations of Avian Muscles Using Magnetic and Other Multimedia Devices

  • Nakajima, Isao;Tanaka, Sachie;Mitsuhashi, Kokuryo;Hata, Jun-ichi;Nakajima, Tomo
    • Journal of Multimedia Information System
    • /
    • v.6 no.4
    • /
    • pp.293-302
    • /
    • 2019
  • In the past, there was a theory that influenza wasn't transmitted directly from birds but was infected to humans via swains. Recently, molecular level research has progressed, and it was confirmed that the avian influenza virus can directly infected to human lung and intestinal epithelial cells. Three pandemicsin the past 100 years were also infected to humans directly from birds. In view of such scientific background, we are developing a method for screening sick birds by monitoring the physiological characteristics of birds in a contactless manner with sensors. Here, the movement of respiratory muscles and abdominal muscles under autonomic innervation was monitored using a magnet and Hall sensor sewn on the thoracic wall, and other multimedia devices. This paper presents and discusses the results of experiments involving continuous periodic noise discovered during flight experiments with a data logger mounted on a Japanese pheasant from 2012 to 2015. A brief summary is given as the below: 1. Magnet and Hall sensor sewn to the left and right chest walls, bipolar electrocardiograms between the thoracic walls, posterior thoracic air sac pressure, angular velocity sensors sewn on the back and hips, and optical reflection of LEDs (blue and green) from the skin of the hips allow observation of periodic vibrations(fasciculations) in the waves. No such analysis has been reported before. 2. These fasciculations are presumed to be derived from muscle to maintain and control air sac pressure. 3. Since each muscle fiber is spatially Gaussian distributed from the sympathetic nerve, the envelope is assumed to plot a Gaussian curve. 4. Since avian trunk muscles contract periodically at all time, we assume that the sympathetic nerve dominates in their control. 5. The technique of sewing a magnet to the thoracic wall and measuring the strength of the magnetic field with a Hall sensor can be applied to screen for early stage of avian influenza, with a sensor attached to the chicken enclosure.

Indoor Illuminance Evaluation on a Mirror Sunlighting System Applied to the Apartments under Real Sky Condition (거울형 태양광 채광시스템의 실제 건축물 적용에 따른 실내주광조도 평가)

  • Jung, Joo Hee;Kim, Jeong Tai
    • KIEAE Journal
    • /
    • v.10 no.4
    • /
    • pp.137-145
    • /
    • 2010
  • Active sunlighting systems have been applied to deliver sunlight into the indoor space where natural light is insufficient, mainly because of the congested high-rise buildings in urban areas. Among various active sunlighting systems, a mirror sunlighting system which is simple structure and economically reasonable has been widely used in different types of spaces such as underground, north facing place and atrium. This study was to evaluate the mirror sunlighting systems, which were consisted of the first mirror of $3.5m{\times}2.5m$, the eight sets of the second mirrors of $1.0m{\times}1.25m$ and a sun tracker. Ten sets of the systems were installed for 40 apartment living rooms, the configuration of $3.5m(W){\times}4.0m(D){\times}2.5m(H)$ where sunlighting were not possible due to high retaining walls located in the front of the living rooms. The 45 HOBO data logger sensors for the indoor illuminance were equipped and 2 Li-cor photometers for outdoor illuminance. Both indoor and outdoor horizontal illuminances were monitored every second from 9am to 3pm on 17 January 2010 under clear sky condition. The results showed that the indoor illuminance of installed mirror sunlighting system was significant relationship with outdoor illuminance and increased the indoor illuminance level by 4.2 times on the whole floor space, by 8 times on the sun patch space of 6m2 and even by 2 times on the no sun patch space. In addition, the luminous conditions of the living room under real sky conditions met the KS recommendation for difficult task (600-1000-1500 lux) such as sewing and reading on whole floor space and sun patch space. It was proved that the benefits of mirror sunlighting systems included an effective technology for penetrating daylight into indoors where sunlighting was not possible and improving occupants' satisfaction and health, and contributing to energy saving in apartments during daytime.

Fundamental Study for Development of Pre-Heater for Warm In-Place Recycling in Korea (국내 현장중온재생공법의 프리히터 개발을 위한 기초연구)

  • Kim, Dae-Hun;Kim, Seung-Hoon;Kwon, Soo-Ahn;Kim, Yongjoo;Lee, Jaejun
    • International Journal of Highway Engineering
    • /
    • v.17 no.2
    • /
    • pp.31-37
    • /
    • 2015
  • PURPOSES : To design a pre-heater for warm in-place recycling equipment, three different heating systems were evaluated to determine their thermal efficiency. METHODS: In this study, a $30cm{\times}30cm{\times}15cm$ wheel-tracking specimen was used to measure the inner temperature as a function of the heating system. The inner temperature of the specimen was measured with a data logger at the surface, and at depths of 1cm, 2cm, 3cm, 4cm, and 5cm. To evaluate the thermal efficiency, the researchers used three different types of equipment, namely, IR, a heating wire, and a gas burner. RESULTS: The IR heating system exhibits a higher level of performance than the others to achieve the target temperature at a depth of 5cm in the specimen. The gas burner system was capable of heating the surface to a temperature of up to $600^{\circ}C$. The other types, however, cannot heat the surface up to 600. The thermal efficiencies were measured based on the laboratory conditions. CONCLUSIONS: To find the most effective system for application to the development of a pre-heater for warm in-place recycling, various systems (IR, heating wire, gas burner) were examined in the laboratory. As a result, it was found that the hot plate of a gas burner system provides the highest temperature at the surface of the asphalt but, of all the systems, the IR system provides the best internal temperature increase rate. Furthermore, a gas burner can age the asphalt binder of the surface layer as a result of the high temperature. However, the gas burner cannot attain the target temperature at 5cm. The IR system, on the other hand, is effective at increasing the internal temperature of asphalt.

Development of High-insulation Packaging using Recycled PET and Comparison of Insulation Performance with Existing Styrofoam and Paper Boxes (재생페트를 이용한 고단열 패키징 개발과 기존의 스티로폼 및 종이 박스와의 단열성능 비교)

  • Ryu, Jae Ryong;Yook, Se Won;Kal, Seung Hoon;Shin, YangJae
    • KOREAN JOURNAL OF PACKAGING SCIENCE & TECHNOLOGY
    • /
    • v.25 no.3
    • /
    • pp.111-116
    • /
    • 2019
  • Thermal insulation performance of new insulation packaging made of recycled PET nonwoven (thickness : 10 mm) was verified by conducting comparative experiment with an EPS box (thickness : 25 mm) and a double wall corrugated box (thickness : 7 mm). Three ice packs (300 g) were positioned 200 mm above the bottom inside each box, all of which are placed side by side and temperature change of 2 points (5mm under middle icepack and 130 mm under middle icepack) was recorded by data logger (GL-840, Graphtec) for 16 hours under the environment of 29℃. The new packaging box showed 75% higher insulation performance than the EPS box and 180% higher than the corrugated box. In order to figure out the reason for insulation performance difference among boxes, thermal conductivities of each box material were measured using heat flow meter (HFM436 lamda, Netzsch). U-value (thermal conductivity divided by thickness) of EPS was lower than recycled pet nonwoven by 57%, which seemed to be opposite to the result of insulation test of boxes. This was explained by high water vapor transmission rate of EPS (6 times higher than PET insulation) and air pocket effect of PET insulation.