• Title/Summary/Keyword: Data logger

Search Result 177, Processing Time 0.034 seconds

Page Logging System for Web Mining Systems (웹마이닝 시스템을 위한 페이지 로깅 시스템)

  • Yun, Seon-Hui;O, Hae-Seok
    • The KIPS Transactions:PartC
    • /
    • v.8C no.6
    • /
    • pp.847-854
    • /
    • 2001
  • The Web continues to grow fast rate in both a large aclae volume of traffic and the size and complexity of Web sites. Along with growth, the complexity of tasks such as Web site design Web server design and of navigating simply through a Web site have increased. An important input to these design tasks is the analysis of how a web site is being used. The is paper proposes a Page logging System(PLS) identifying reliably user sessions required in Web mining system PLS consists of Page Logger acquiring all the page accesses of the user Log processor producing user session from these data, and statements to incorporate a call to page logger applet. Proposed PLS abbreviates several preprocessing tasks which spends a log of time and efforts that must be performed in Web mining systems. In particular, it simplifies the complexity of transaction identification phase through acquiring directly the amount of time a user stays on a page. Also PLS solves local cache hits and proxy IPs that create problems with identifying user sessions from Web sever log.

  • PDF

Development of a Voltage Measuring System for the Pusan-Hamada Submarine Cable (부산 - 병전간 해저케이블 전압측정 장치의 개발)

  • Bahk, Kyung-Soo
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.3 no.4
    • /
    • pp.255-260
    • /
    • 1991
  • A voltage measuring system specified for the voltage fluctuation of the Pusan-Hamada submarine cable is developed by adding circuits of differential amplification and analog-to-digital conversion to a microprocessor-based data logger with a data modem. This system is charaterized by its small size. no power failure. fully unmanned operation. and precise instrumental drift correction. In addition to the cable voltage and current it measures an ambient temperature and a mercury cell voltage in order to calibrate temperature effect and check its long-term stability. The data acquired by this system show that the voltage signal. comprising fast random noises with a constant width of about 0.2V. fluctuates within a range of about 1V and the fluctuation frequency is similar to that of tidal motion. The source voltage of power feeding equipment (PFE) for the cable system seems to be affected when the room temperature changes rapidly.

  • PDF

Statistical Probability Analysis of Storage Temperatures of Domestic Refrigerator as a Risk Factor of Foodborne Illness Outbreak (식중독 발생 위해인자로서 가정용 냉장고의 온도에 대한 확률분포 분석)

  • Bahk, Gyung-Jin
    • Korean Journal of Food Science and Technology
    • /
    • v.42 no.3
    • /
    • pp.373-376
    • /
    • 2010
  • The objective of this study was to present the proper probability distribution model based on the data obtained from surveys on domestic refrigerator food storage temperatures in home. Domestic refrigerator temperatures were determined as risk factors in foodborne disease outbreaks for microbial risk assessment (MRA). The temperature was measured by directly visiting 139 homes using a data logger from May to September of 2009. The overall mean temperature for all the refrigerators in the survey was $3.53{\pm}2.96^{\circ}C$, with 23.6% of the refrigerators measuring above $5^{\circ}C$. Probability distributions were also created using @RISK program based on the measured temperature data. Statistical ranking was determined by the goodness of fit (GOF, i.e., the Kolmogorov-Smirnov (KS) or Anderson-Darling (AD) test) to determine the proper probability distribution model. This result showed that the LogLogistic (-10.407, 13.616, 8.6107) distribution was found to be the most appropriate for the MRA model. The results of this study might be directly used as input variables in exposure evaluation for conducting MRA.

Comparison of Positioning Accuracy Using the Pseudorange from Android GPS Raw Measurements (안드로이드 GPS 원시데이터의 의사거리를 이용한 측위 정확도 비교)

  • Gim, Joonseong;Park, Kwan-dong
    • Journal of Advanced Navigation Technology
    • /
    • v.21 no.5
    • /
    • pp.514-519
    • /
    • 2017
  • In this paper, the pseudorange-based GPS performance using the Android's raw measurements is compared with NMEA. In order to compare the performance between the two different implementations, we used Nexus 9 tablets and collected the raw measurements and NMEA data using the GNSS logger application provided by Google. To verify the performance of the final coordinates calculated, the VRS was used as the reference coordinate and compared with the NMEA results. The resulting horizontal, vertical, and 3D RMS errors of the pseudorange-based GPS using the Android's raw measurements are 3.05, 3.82, and 4.97 m, respectively, which correspond to 32% horizontal, 65% vertical and 49% 3D performance improvement compared with NMEA.

A Study on a Wind Turbine Data Logger System based on WiFi for Meteorological Resource Measurement (기상자원 측정을 위한 와이파이 기반의 풍력용 데이터로거 시스템에 관한 연구)

  • Jung, Se-Hoon;Sim, Chun-Bo
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.10 no.1
    • /
    • pp.55-64
    • /
    • 2015
  • Wind turbine market is showed height growth rate of about 30% for year, and is increasingly growing. Total rate of domestic wind turbine installation is showing share of 0.2% of the global market that is 380MW. However, wind turbine installed in domestic are foreign product more than 90%. Similarly, Datalogger of pretest system for ocean wind turbine plant installation has been leaked huge cost to abroad by mostly abroad company product. In this paper, we proposed pretest weather resource measurement system for efficiency and investment cost cutting of wind turbine construction work. Preset weather resource measurement system is ocean weather resource measurement datalogger based on wireless communication(wifi) that have consist of hardware and software(wind rose) that is able to monitoring as datalogger of wireless bridge and battery state, wind direction, wind speed, temperature, humidity, radiation around weather tower and is able to analysis of measured data.

Design and Implementation of Wet Diaper Sensor for U-Healthcare (유비쿼터스 헬스케어를 위한 대소변 감지기 설계 및 구현)

  • Yi, Yun-Jae;Kim, Tae-Suk;Park, Chul-Ho;Lim, Dong-Ha;Choi, Ik-Soo;Kim, Nam-Ho;Yu, Yun-Seop
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2011.05a
    • /
    • pp.793-795
    • /
    • 2011
  • In this paper, an wet diaper sensor system for u-healthcare is implemented and designed. The u-healthcare system of wet diaper sensor consists of sensor node, data-logger/gateway, and server or user terminals. The sensor node includes $NH_3$, humidity, and temperature sensors and TI CC2530 chip, and the data-logger/gateway can connect to a communication network and send the aggregated data from the sensor nodes to a server, and the server can manage the situation of the sensor node and make another analyzed information. Also user terminals can request and obtain the information necessary from the server. The algorithm for detecting wet diaper is proposed, and using the proposed algorithm, the sensitivity for detecting wet diaper is 100%.

  • PDF

FIELD EXPERIENCE OF PORTABLE SMPS+C NANO PARTICLE SIZER

  • Gerhart, Ch.;Grimm, H.J.;Heim, M.
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2003.05b
    • /
    • pp.47-48
    • /
    • 2003
  • This new family of portable real time SEQUENTIAL MOBILITY PARTICLE COUNTER and SIZER (SMPS+C) is designed for mobility and easy field use. An integrated battery assures hours of operation, a data logger system storage of all optioned results and a user friendly powerful software easy operation. This technology not only simplifies the SMPS operation, but it permits new on site application monitoring up to a remote wireless telephone operation. (omitted)

  • PDF

PC 병렬포트를 이용한 12 bit Data Logger(PPDL12)

  • 이종국;여운광
    • Proceedings of the Korean Society of Coastal and Ocean Engineers Conference
    • /
    • 1997.10a
    • /
    • pp.147-150
    • /
    • 1997
  • 일반적으로 공학적인 문제를 해결하기 위하여는 수치모형을 이용한 접근방법도 중요하지만 실험, 실측 및 관측분야도 도외시 할 수는 없다. 그 주된 이유는 이들 두 분야가 서로 별개로 독립적으로 존재하는 것이 아니라 서로 보완적이기 때문이며 따라서 이들 두 분야의 균형적인 발전없이는 아무리 최신의 모형을 사용하더라도 그 한계가 있다. 실제로 수치모형의 신뢰성을 확보하는데는 물리적 현상에 기초한 실측값들과의 비교ㆍ검증절차가 필수적 사안이다. (중략)

  • PDF

The Implementation of Server-Client Program based Data Logger System (서버-클라이언트 프로그램 기반의 데이터 로거 시스템 구축)

  • 최관순;전흥구;유홍진
    • Proceedings of the KAIS Fall Conference
    • /
    • 2003.06a
    • /
    • pp.281-283
    • /
    • 2003
  • 데이터 로거 시스템은 자동화 시스템과 더불어 땀이 사용되어 지고 있는 시스템이다. 근ㆍ원거리의 시스템으로부터 실시간으로 데이터를 취득하기 위해 본 논문에서는 ATmega128을 사용하여 데이터 로거 시스템을 구현하였으며, 윈도우 환경에서 사용할 수 있도록 Visual Basic을 사용하여 서버-클라이언트 기반의 운영 프로램을 개발하였다. 개발된 시스템은 실시간의 데이터를 그래프로 가시적으로 표현함으로써 데이터의 변동량을 쉽게 파악할 수 있도록 하였다.

  • PDF

Development of Realtime Bridge Safety Monitoring System (실시간 교량 안전감시시스템 개발)

  • Nam, Myung-Woo;Yang, Ok-Yul;Lee, Young-Seock;Oh, Myung-Kwan
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.1
    • /
    • pp.79-84
    • /
    • 2010
  • In this paper, we developed the BMSWare(Bridge Management System Middleware) for bridge safety surveillance in real time processing. The developed system operates on web and considers the general monitoring application for bridges. In various environments in geographical location of bridge, it can obtain reliably data from various logger and sensors without re-programming. The main functions of the developed system include the acquisition, processing, backup and transmission of the collected sensor data. It was proved to be the safety and effectiveness by application of Mooyeong bridge.