• 제목/요약/키워드: Data logger

검색결과 178건 처리시간 0.025초

디이젤기관의 방열에 관한 연구 (A study on the heat dissipation of diesel engine)

  • 이창식
    • 오토저널
    • /
    • 제2권1호
    • /
    • pp.39-50
    • /
    • 1980
  • This paper presents the variations obtained in heat flow rate and engine performance of a four-stroke cycle Diesel engine when there were changes in the temperature of cooling water, compression ratio, injection timing of fuel, and other factors. Heat dissipation of engine cylinder was calculated by the heat transfer coefficient of Nusselt's empirical equation and the analysis of distribution of temperature in cylinder barrel was obtained by the finite element method of two-dimensional steady state heat conduction. In this experiment, the out side temperature of cylinder liner was measured by the data logger, and the temperature distribution of liner was computed by the analysis of triangular finite element model under the assumption due to surface heat flux of cylinder inner surface. The results obtained by this study are as follows. Under the given operating condition, the temperature distribution of cylinder liner by using finite element method shows that the mean temperature of barrel is in accordance with the experimental results of Eichelberg and temperature difference is lower than 4.23.deg. C. The heat dissipation of engine decrease in accordance with the decrease of piston mean velocity, compression ratio, and the increase of coolant temperature. Influence on the delay of injection timing of fuel brings about the decrease of heat rejection over the cylinder at constant test conditions.

  • PDF

고온 환경이 젖소의 생산성 및 축사환경에 미치는 영향 연구 (A Study on the Effects of Heat Stress on Feedlot Environment and Productivity of Dairy Cattle)

  • 김별;임정수;조성백;황옥화;양승학
    • 한국축산시설환경학회지
    • /
    • 제20권2호
    • /
    • pp.63-68
    • /
    • 2014
  • Environmental heat stress by global warming has a severe effect on the productivity of livestock and, in particular, on that of dairy cattle. Heat stress during high temperature environment directly and indirectly affects milk yield, milk quality and physiological response. This study was conducted to investigate the effects of heat stress on productivity and physiological responses of livestock. Temperature-humidity data logger were established inside the feedlot for measuring real time changes in the feedlot environment. Milk was collected every day for analysing the productivity of dairy cattle. Blood sample and respiration of dairy cattle were collected once in a week for investigating the physiological response factors. Blood component concentration associated with lipolysis metabolism and milk production showed change during tropical night period. Temperature humidity index (THI) of a specific location inside the feedlot showed continuously high levels.

프로파일링 세굴 모니터링 시스템을 이용한 교각 국부세굴 계측 및 평가 (The measurement and evaluation of local scour at a bridge pier using the profiling scour monitoring system)

  • 신종현;박현일;신승현;박경수
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2009년도 춘계 학술발표회
    • /
    • pp.38-47
    • /
    • 2009
  • Scour means the erosion of bed material by flow change when a bridge is constructed in a stream. Scour is one of the critical factors of a bridge failure. There are several methods for the monitoring of scour near bridge foundations; Sounding rods, Magnetic sliding collar System, Sonar system, underwater camera system and so on. In general, Sonar system is preferred due to its convenience and good accuracy. In this study, the new scour monitoring system was developed using profiling sonar sensor. The new system can measure a line profile of a seabed and has small size due to the effectively designed data logger. The performance of the new scour monitoring system was evaluated at a bridge pier in tidal environment. The measured local scour depths were discussed with the result of the empirical formulas; CSU, Froehlich, Laursen and Neill.

  • PDF

특수형 정측창 시스템의 자연채광성능에 관한 축소모형 실험 - 선 스쿠프, 라이트 스쿠프 및 선 캐처 시스템을 중심으로 - (Scale Model Experiments on Daylighting Performance of Topside Lighting Systems - Focused on Sun Scoop, Light Scoop and Sun Catcher Systems -)

  • 공효주;김정태
    • KIEAE Journal
    • /
    • 제8권1호
    • /
    • pp.45-52
    • /
    • 2008
  • Daylighting systems can improve the luminous quality of indoor environment and reduce the building's electric lighting energy consumption. For designing good daylighting, place the light where it is desired and avoid excessive contrasts, glare and high light levels. Sun scoop, light scoop and sun catcher systems have been used for alternative systems compared to other natural lighting systems. This study aims to evaluate daylighting performance of sun scoop, light scoop and sun catcher systems using scale model experiments. For the purpose, the 1/10 scale models of the systems were made as the same areas of glazing(10 percent of floor area) on the top of the center roof. Totally 15 measuring points of illuminance on the horizontal work plane were monitored from 09:30 to 12:30 on October 29, 2007. Agilent data logger and photometric sensors Li-cor were used. As the results, the topside lighting systems can improve the illumination uniformity than side lighting and top lighting. However, the appropriated shading system should be integrated to prevent the direct sunlight.

A STUDY ON INDUSTRIAL GAMMA RAY CT WITH A SINGLE SOURCE-DETECTOR PAIR

  • Kim Jong-Bum;Jung Sung-Hee;Kim Jin-Sup
    • Nuclear Engineering and Technology
    • /
    • 제38권4호
    • /
    • pp.383-390
    • /
    • 2006
  • Having its roots in medical applications, industrial gamma ray CT has opened up new roads far investigating and modeling industrial processes. Using a line of research related to industrial gamma ray CT, the authors set up a system of single source and detector gamma transmission tomography for wood timber and a packed bed phantom. The hardware of the CT system consists of two servo motors, a data logger, a computer, a radiation source and a radiation detector. One motor simultaneously moves the source and the detector for a parallel beam scanning, whereas the other motor rotates the scan table at a preset projection angle. The image is reconstructed from the measured projections by the filtered back projection method. The phantom was designed to simulate a cross section of a packed bed with a void. The radiation source was 20mCi of Cs-137 and the detector was a 1 inch $\times$ 1 inch NaI (TI) scintillator shielded by a lead collimator. The experimental gamma ray CT image has sufficient resolution to reveal air holes and the density distribution inside the phantom. The system could possibly be applied to a packed bed column or a pipe flow in a petrochemical plant.

DC-link Capacitor필름 형상에 따른 Joule-heat특성 분석 (Analysis of Joule-heat Characteristics according to the DC-link Capacitor Film Geometrics)

  • 전용원;김영신;전의식
    • 반도체디스플레이기술학회지
    • /
    • 제19권1호
    • /
    • pp.42-48
    • /
    • 2020
  • As global warming accelerates, eco-friendly electric cars are being developed to reduce carbon dioxide emissions, and power conversion inverters are used to drive motors. Among inverter components, DC-link capacitor is heated by high current usage, which causes problems such as performance and life-saving of inverter. Although metal cases with good thermal performance have been used to solve this problem, it is difficult to apply them in practice due to insulation problems with other parts. In this paper, the Heat-Generation influence factor of DC-link capacitor is analyzed. Variables on heat-generation are set at 3 levels for film width, inductance, and film thickness. Box-Behnken to 13 tests using the design and minimal deviations, e.g. through the experiment three times by each level. The surface of the film k type by attaching the sensor current is measured temperature. Capacitance was set to a minimum level of 200 ㎌ and had a frequency of 16 kHz with Worst case, ambient temperature of 85℃ and a ripple current of 50 Ams was applied. The temperature at the measurement point was collected in the data logger after sampling at 1 minute intervals for 2 hours after saturation with the ambient temperature. This experiment confirmed that setup factors are correlated with heat-generation.

Comparison of Tilt Variation in the Otter Board and Codend of Bottom Trawl Gear during Fishing Operations

  • Kim, Yong-Hae
    • Fisheries and Aquatic Sciences
    • /
    • 제17권1호
    • /
    • pp.145-153
    • /
    • 2014
  • The motion of the otter board on a trawl can affect the motion of trawl nets, and the motion of the codend can affect fish selectivity. Preliminary measurements of the tilt of bottom trawl gear were carried out to compare the tilts of the otter board and codend. The tilt of the otter board was measured by Vector and tilt at 1.5 m anterior to the end of the codend, and the middle upper panel was measured with a micro-DST-tilt logger. Tilt data such as yaw, pitch, and roll were analyzed by the fast Fourier transformation method and global wavelet and event analyses for the period or amplitude. The mean period ${\pm}$ standard deviation of the tilt in the otter board, $(5-6){\pm}2s$, was similar to the period of the codend, $(4-6){\pm}(2-3)s$, whereas the amplitude of the codend was greater than that of the otter board. The yaw and pitch periods were not significantly different between the otter board and codend, but roll was different. Furthermore, the tilt period frequencies of the otter board and codend were not significantly different. Accordingly, the tilt motion of the codend was mostly related to the tilt of the otter board.

극한 환경에서 온도 변화에 따른 실외 현장에서의 무선 MEMS 센서 계측 유효성 평가 (Evaluation of Wireless MEMS Sensor Measurements at an Outdoor Field With Temperature Variation in Extreme Environment)

  • 이종호;천동진;윤성원
    • 한국공간구조학회논문집
    • /
    • 제18권3호
    • /
    • pp.67-74
    • /
    • 2018
  • Recently, measuring instruments for SHM of structures has been developed. In general, the wireless transmission of sensor signals, compared to its wired counterpart, is preferable due to the absence of triboelectric noise and elimination of the requirement of a cumbersome cable. However, in extreme environments, the sensor may be less sensitive to temperature changes and to the distance between the sensor and data logger. This may compromise on the performance of the sensor and instrumentation. Therefore, in this paper, free vibration experiments were conducted using wireless MEMS sensors at an actual site. Measurement was assessed in time and frequency domain by changing the temperature variation at($-8^{\circ}C$, $-12^{\circ}C$ and $-16^{\circ}C$) and the communication distance (20m, 40m, 60m, 80m).

실내조명의 발열량 예측에 관한 실험 연구 (The Performance of generated Heating Energy from Interior Lighting Fixtures)

  • 최종선;임홍수;김경아;이금환;구재오;김곤
    • KIEAE Journal
    • /
    • 제10권6호
    • /
    • pp.27-32
    • /
    • 2010
  • Approximately 20 percentage of energy consumptions in buildings is consumed as lighting energy. Thus, most of the corporations of lighting fixture have launched low energy products. However, many researchers focused on the only luminous efficacy for energy conservation and used the evaluating tool of study. This can not gauge the precise cooling load related on generated heat of artificial lighting. In order to assess an effect of the temperature variation of lighting resources, the main purpose of this study is to predict the generated heating energy from lighting by measuring the thermal variation in scale model to reduce external noise. Also this paper used MX100 data logger to record at an interval of 1 minute for 60 minutes for the temperature of interior lightings such as incandescent lamp, fluorescent light, halogen lamp and LED lamp. As a result, LED lamp generated the lowest heat. On the other hand, incandescent lamp did the highest.

편측창에서 창개구부의 형상이 천공상태별 채광성능에 미치는 영향 (Effects of Different Fenestration Configurations on Daylighting Performance in Unilateral Window under Clear and Overcast Sky Conditions)

  • 술타나 아즈미리;김정태
    • KIEAE Journal
    • /
    • 제9권5호
    • /
    • pp.105-113
    • /
    • 2009
  • Daylighting provides the opportunity for both energy savings and improved visual comfort. An accurate estimation of the amount of daylight entering a building is the key step for daylight designing. This research aims to assess comparative daylighting performance of four different configurations of fenestration in case of unilateral windows and their variation under clear and overcast sky conditions. The selected window openings in this study were single punched, double punched, multiple punched and clerestory, and the area was same for each type of window. The experiment was designed for an office space using 1/10 scale model. Daylighting performance was evaluated by measuring the illuminance on work-plane height using Agilent data logger and photometric sensor Li-Cor. Thecomputer program ECOTECT was also used to simulate the pattern of interior illuminance distribution. Clerestory window showed the best performance in term of both illuminance level and distribution in the experiment. Multiple punched window provided more uniform illuminance distribution than single punched window. Lowest daylighting performance in the experiment was shown by double punched window.