• Title/Summary/Keyword: Data collector

Search Result 192, Processing Time 0.037 seconds

Simulation of Solar and Ambient-air-assisted Heat Pump (태양열 및 외기 열원식 히트펌프 시스템 시뮬레이션)

  • Baeck, N.C.;Park, J.U.;Song, B.H.;Lee, J.K.;Kim, H.J.
    • Solar Energy
    • /
    • v.20 no.4
    • /
    • pp.17-24
    • /
    • 2000
  • Thermal performance of a SAAHPS (Solar and Ambient-air-assisted Heat Pump System) located in KIER is simulated with TRNSYS 14.2. The SAAHPS is composed of dual evaorators, each of which is used as a solar fluid heat source and an air fluid heat source. Polynomial coefficients data for the SAAHPS is supplied with Frigosoft, a program widely used for heat pump modeling. In general, collector area and storage volume are 2 key parameters in SAAHPS thermal performance. A parametric study is performed in this study to assess sensitivity of collector area and storage volume in SAAHPS. We concluded that firstly collector area and storage volume are the primary variables in SAAHPS thermal performance, secondly COP of SAAHPS is higher than that of conventional heat pumps. Therefore. collector efficiency can be enhanced swith SAAHPS during a heating season.

  • PDF

Simulation and Model Validation of a Parabolic Trough Solar Collector for Water Heating

  • Euh, Seung-Hee;Kim, Dae Hyun
    • Journal of the Korean Solar Energy Society
    • /
    • v.33 no.3
    • /
    • pp.17-26
    • /
    • 2013
  • The aim of this study is to analyze the performance of a parabolic trough solar collector (PTC) for water heating and to validate the model performance. The simulated model was compared, calibrated and verified with the experimental results. RMSE (Root mean square error) was used to calibrate the convective heat transfer coefficient between the absorber pipe and the ambient air which was the main factor affecting the heat transfer associated with the PTC. The calibrated model was better fitted with the experimental model. The maximum, minimum and mean deviation between the measured and predicted water temperatures differed only $0.81^{\circ}C$, $0.09^{\circ}C$ and $0.31^{\circ}C$ respectively in the calibrated model. RMSE values were decreased from 0.5389 to 0.4910, 0.0134 to 0.0125 and R-squared was increased from 0.9955 to 0.9956 after calibration. The temperature of water was increased from $33.7^{\circ}C$ to $48^{\circ}C$ in 12hour test. The thermal efficiency of the collector was calculated to be 55%. The calibrated model showed good agreement with the experimental data for model validation.

A Study on the Solar Water Heating System in the Military Facilities (병영시설의 태양열급탕시스템에 관한 연구)

  • Kim, Doo-Chun;Seo, Jin-Seok
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.11 no.4
    • /
    • pp.6-18
    • /
    • 1982
  • The performance of two typical types of solar hot water heating system was tested in Seoul. Types of systems studied are single-tank internal external heat exchanger system and single-tank internal heat exchanger system. Comparing to experimental results, a transient system simulation program was made to analyze the performance of the selected system. The climate data, Standard Weather Year for Seoul, required for the simulation was provided. Computer simulations were used to estimate the effect of significant parameters upon system performance. The followings are obtained. 1. In the domestic solar water Heating system, the value $20-40kg/m^2\;h$ for flow rate through the collector is much better than the recommended value $72kg/m^2\;h$ in the solar heating system. 2. The effectiveness of collector heat exchanger and storage tank size are found to have only a small effect upon system performance. 3. The hot water draw pattern has a significant effect on system performance. A higher system efficiency achieved when draw-off occurred around noon than when it occurred around early morning. Using the above results, the reference solar hot water system which provides $300\ell$ of hot water per day, was selected as a guide for designer. And simplified graphical method was developed based on the modified f-chart method to determine required collector area. When the system design parameters of the proposed system differs from the reference system, required collector area can be calculated from area adjustment factors.

  • PDF

One-time measurement of irradiation intensity of Solar Simulator using cds photo-sensors (cds 광전소자(光電素子)를 이용한 인공태양(人工太陽) 일사강도(日射强度)의 동시측정(同時測定))

  • Bai, K.;Cho, S.H.;Lee, N.H.;Auh, P.C.M.
    • Solar Energy
    • /
    • v.5 no.2
    • /
    • pp.28-34
    • /
    • 1985
  • There are two kinds of irradiation intensity deviation, depending on time and position, on illuminated plane when thermal performance of solar collector is tested by using solar simulator. In this study we measured only position deviation of irradiation intensity using 45-cds photosensors and data acqusition system and found the point of average value. By this result we can improve the accuracy of irradiation measurement in indoor test of solar collector.

  • PDF

Uncertainty of Efficiency Equation of Solar Thermal Collectors (태양열 집열기 효율식의 불확도)

  • Lee, Kyoung-Ho;Lee, Soon-Myung
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.11a
    • /
    • pp.65.1-65.1
    • /
    • 2010
  • Thermal performance tests of solar thermal collectors include determination of coefficient parameters in an efficiency equation. The parameters can be estimated using regression method to minimize an objective function as sum of differences between measured efficiency data and regressed efficiency equation. However, this conventional approach doesn't consider measurement uncertainties. In this presentation, a method to determine regression parameters in the efficiency equation and uncertainties of the parameters is described with mainly mathematical expressions based on literature reviews. In the method, parameters in the equation for collector efficiency can be determined using regression analysis with a weighting factor in the objective function. The weighting factor can be uncertainties of the differences between measured and fitted efficiencies. To evaluate the approach, performance estimation of a solar collector using the efficiency equation with uncertainties is compared to the result using the conventional efficiency equation by a simulated way for a case in one of previous studies.

  • PDF

The Basic Study on Economic Evaluation of Distributed Energy System Installed in Hospital (병원건물 분산에너지시스템 도입에 따른 경제성분석)

  • Hong, Won-Pyo;Kim, Hyoung-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.1136_1138
    • /
    • 2009
  • This paper gives a basic Energy performance data of micro gas turbine and Renewable Energy(BIPV and Solar Collector System) installed in Hospital Building. The efficiency of solar collector and BIPV system was 30%, 10% individually, and lower than micro gas turbines. Micro gas turbines are small gas turbines that burn gaseous and liquid fuels to produce a high-energy exhaust gas and to generate the electrical power. Recently the size range for micro gas turbines is form 30 to 500kW and power-only generation or in combined heat and power(CHP) systems. If micro gas turbine was operated only for electric energy, the efficiency was about 30%, but for combined heat and power, the efficiency was about 90%. Finally, installed in large hospital, Micro gas turbine system was operated to CHP mode, was high-efficiency system than Solar collector and BIPV system.

  • PDF

Fabrication and characteristics of AlGaAs/GaAs SABM HBTs (AlgaAs/GaAs SABM HBT의 제작 및 특성)

  • 이준우;김영식;서아람;서영석;신진호;김범만
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.32A no.1
    • /
    • pp.129-137
    • /
    • 1995
  • AlGaAs/GaAs HBTs have been fabricated using SABM (Self-Aligned Base Metal) process technique. The mesa type HBTs were fabricated through following steps: isolation implant, wet etching, metal lift-off, and airbridge interconnection process. The fabricated HBTs with 2umx10um size emitter showed a common emitter current gain of 10 at a collector current density of Jk=100kA/cm$^{2}$, a breakdown volgate BVCEO of 8V, and the ideality factors of base and collector junctions of 1.6 and 1.1, respectively. On-wafer S-Parameter measurement at 0.5~18GHz has been made for the characterization of the common emitter HBTx with a 2umx10um size emitter. The extrapolated current gain cut-off frequency of ft=30GHz and maximum oscillation frequency of fmax=23 GHz were obtained at a collector current density of Jc=70kA/cm$^{2}$. Small signal HBT equivalent circuit was extracted from the S-Parameter data.

  • PDF

A study on the analysis of power system due to the expansion of renewable energy (신재생에너지 확대에 따른 전력계통 해석에 관한 연구)

  • Sin, Hae-Su;Cho, Yoon-Sung
    • Journal of IKEEE
    • /
    • v.22 no.3
    • /
    • pp.729-732
    • /
    • 2018
  • This paper performs Agregation for supplementing the additional generator when reflecting the plan DB based on a number of renewable power sources, line and transformer data. In this study, modeling of a line and a generator through a Collector method and a Step-Up-Transformer among Aggregation execution methods is conducted.

The Basic Study on Economic Evaluation of Micro-turbine and Alternative Energy system Installed in Hospital (병원건물의 마이크로터빈과 신재생에너지도입에 따른 경제성평가 기초연구)

  • Kim, Byoung-Soo;Hong, Won-Pyo
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2009.05a
    • /
    • pp.439-444
    • /
    • 2009
  • This paper gives a basic Energy performance data of micro gas turbine and Renewable Energy(BIPV and Solar Collector System) installed in Hospital Building. The efficiency of. solar collector and BIPV system was 30%, 10% individually, and lower than micro gas turbines. Micro gas turbines are small gas turbines that bum gaseous and liquid fuels to produce a high-energy exhaust gas and to generate the electrical power. Recently the size range for micro gas turbines is form 30 to 500kW and power-only generation or in combined heat and power(CHP) systems. If micro gas turbine was operated only for electric energy, the efficiency was about 30%, but for combined heat and power, the efficiency was about 90%. Finally, installed in large hospital, Micro gas turbine system was operated to CHP mode, was high-efficiency system than Solar collector and BIPV system.

  • PDF

A study on the method for calculating the base-collector breakdown voltage of NPN BJT for integrated circuits (집적회로용 NPN BJT의 베이스-컬렉터간 역방향 항복전압 계산 방법에 관한 연구)

  • Lee, Eun-Gu;Lee, Dong-Ryul;Kim, Tae-Han;Kim, Cheol-Seong
    • Proceedings of the KIEE Conference
    • /
    • 2002.11a
    • /
    • pp.137-140
    • /
    • 2002
  • The algorithm for calculating the base-collector breakdown voltage of NPN BJT(Bipolar Junction Transistor) for integrated circuits is proposed. The method for calculating the electric field using the solution of Poisson's equation is presented and the method for calculating the breakdown voltage using the integration of ionization coefficients is presented. The base-collector breakdown voltage of NPN BJT using 20V process obtained from the proposed method shows an averaged relative error of 8.0% compared with the measured data.

  • PDF