A Forward Speed Control of Head-feed Combine Using Continuously Variable V-belt Transmission -Combine Load Characteristics- (V-벨트 무단변속기(無斷變速機)를 이용(利用)한 자탈형(自脫型) 콤바인의 주행속도(走行速度) 제어(制御)(I))

  • Choi, K.H.;Ryu, K.H.;Cho, Y.K.;Park, P.K.
    • Journal of Biosystems Engineering
    • /
    • v.16 no.2
    • /
    • pp.124-132
    • /
    • 1991
  • This study was carried out to obtain the information needed in the development of forward speed control system and the improvement of combine performance. The effects of variety, grain moisture content and forward speed on the combine load characteristics were investigated through experiments. The results of this study are summarized as follows. 1. A data acquisition system was developed to measure the engine speed and the torques and speeds of the threshing cylinder, dean-grain auger and tailings-return auger. The system consisted of transducers, signal conditioner, interface board and microcomputer. The system accuracy is better than ${\pm}2.3%$ full scale. 2. Linear regression equations were obtained for the torque, speed and power requirement of threshing cylinder for different paddy varieties, grain moisture contents and feed rates. 3. The maximum value of relative frequency for threshing cylinder torque decreased as the increase in feed rate and moisture content. The range of torque fluctuation was 1.2~3.7 and 1.2~1.9 times the average and maximum torque, respectively. The maximum value of power spectrum density (PSD) appeared to be about 11 Hz regardless of paddy variety, grain moisture content and feed rate. 4. The speed of tailings return thrower decreased rapidly at below 900rpm, and it fell to near zero about 3 seconds after that time. When the travelling of combine harvester was stopped immediately after sensing the overload, it took about 7 seconds for a full recovery of the no-load speed of tailings return thrower.

  • PDF

Development of a Moisture Content Sensor for Rapeseed as Biodiesel Raw Material (바이오디젤 원료용 유채 함수율 센서 개발)

  • Lee, Choung-Keun;Choi, Yong;Jun, Hyun-Jong;Jung, Kwang-Sik
    • Journal of Biosystems Engineering
    • /
    • v.34 no.1
    • /
    • pp.15-20
    • /
    • 2009
  • This study was conducted to develop a moisture sensor for rapeseed, a bio-diesel material. A typical rapeseed, SUNMANG, was used as a raw material. The rapeseed moisture content sensor consists of three components, such as upper and bottom electrodes, a test material dish, and a fixing housing. To evaluate the performance, a data acquisition system was equipped with the rapeseed moisture sensor, computer, printer, and main board. The findings of this study were: 1) the rapeseed moisture content was inversely proportional to electric resistance, and 2) values of electric resistance were recorded in a range of $10{\sim}100\;M{\Omega}$, depending upon a change of the moisture content. The determination of coefficient ($R^2$) and standard error between rapeseed moisture content and electric resistance were 0.9921 and ${\pm}0.289$, which indicated a highly correlative relationship. The response of rapeseed moisture sensor to temperature change was also observed for further performance test. Satisfying results were obtained, such as the determination of coefficient ($R^2$) of 0.9918, predicted standard error of ${\pm}0.373%$, deviation of 0.103%, measurement error of $0.14{\sim}0.48%$, standard deviation of $0.01{\sim}0.22%$, and measurement time of 28.3 s per point, respectively.

Development of Pulse Analysis System Based on Convenience and Compactness (사용 편의성과 소형화 기반의 맥파 측정장치 개발)

  • Cho, JungHee;Bae, JangHan;Kim, YoungMin;Jun, MinHo;Yang, TaeHeon;Jeon, YoungJu
    • Journal of Biomedical Engineering Research
    • /
    • v.38 no.4
    • /
    • pp.168-174
    • /
    • 2017
  • To improve and downsize the KIOM-Pulse Analysis System(KIOM-PAS), which has been traditionally used in clinical trials, a miniaturized PAS(M-PAS) with a pneumatic pump has been developed. M-PAS is composed of a measurement module and an arm-mounting module, on which an arm can be placed. The measurement module is equipped with a pressing component and sensor, which is a wearable wristband. The arm-mounting module includes a pneumatic motor, data acquisition board and valves. In addition, the measurement module is divided into a fixing module of band type for attachment to a pulsation site and a sensing module, which includes a sensor and a tube. The fixing module and sensing module are constructed independently, and the detachable fastening method improves the posture convenience of the subject during measurement. M-PAS has been reduced to 1/6 the size of KIOM-PAS, and the measurement time is shortened by 22%. Using a simulator, the difference between the waveforms measured by the two devices exhibited a high degree of similarity of within 3.65%. M-PAS represents improvements in size and convenience compared with KIOM-PAS, and it is expected to be widely used in clinics in the future because it improves the attachment method of the fixing module.

Performance analysis of the optical displacement sensor for accurate in-plane motion measurement (정확한 평면운동 측정을 위한 광 변위센서의 성능분석)

  • Kang, Hoon;Lee, Hunseok;Oh, Jin-Seok
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.20 no.3
    • /
    • pp.639-646
    • /
    • 2016
  • In this study, the contactless measurement method with a optical displacement sensor(ODS, ADNS 9500) was proposed to overcome flaws in a rotary encoder based measurement under particular circumstances, such as a slippage and a case of little rotational inertia. The performance tests of the optical displacement sensor using data acquisition board and National Instruments's LabVIEW program were performed to accomplish accurate displacement measurements and the performance characteristics according to measurement direction, speed, acceleration, height and surface types were discovered through the repetitive tests. The experimental results indicate that, in order to get an accurate in-plane motion, the height(distance between the ODS and the target surface) has to be maintained at the range of 2.4 mm to 3.2 mm and the sensitivity(resolution) should be modified and applied to the formulae for displacement calculation, considering its measurement direction, speed and surface type.

Health Education Needs of Mothers who are Caring for Children with Disabilities (장애아동 양육을 위한 어머니의 건강관련 교육요구)

  • Han, Young-Ran;Lee, Myoung-Hee;Bang, Mi-Ran
    • Child Health Nursing Research
    • /
    • v.12 no.1
    • /
    • pp.44-56
    • /
    • 2006
  • Purpose: The purpose of this study was to investigate the health education needs of mothers who are nurturing children with disabilities. Method: A descriptive study was done and the participants were 108 mothers of children with disabilities such being mentally challenged, developmentally delayed or having a disability involving brain damage. The questionnaire was a health education need assessment with 11 categories(58 items) developed by Han et al. The data were analyzed using SPSS program. Results: The mean score for health education needs of the mothers of children with disabilities was 3.83 (SD=0.58) out of a maximum 5. The health education need for acquisition of knowledge and information had the highest score (4.40±0.54) followed by health education needs for cognitive development and learning (4.31±0.64), interpersonal relationships (4.04±0.65) and behavior and emotion (4.04±0.79). There were significant differences between the children's sex (t=2.08, p=.04), birth order (t=2.17, p=.03), grade of disability (F=3.32, p=.02) and sex education suitable to the child's in age. Conclusion: The health education needs of mothers of children who are disabled were very high and varied. Therefore, it was important to develop comprehensive education programs which include this content and provide opportunities for mothers of children with disabilities to receive this education.

  • PDF

Fault Diagnosis of Induction Motor using analysis of Stator Current (고정자 전류 분석을 이용한 유도전동기 고장진단)

  • Shin, Jung-Ho;Kang, Dae-Seong
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.10 no.1
    • /
    • pp.86-92
    • /
    • 2009
  • As increasing of using induction motors, the induction motors faults cause serious damage to the industry. Therefore to find out faults of induction motor is recognized as important problem awaiting solution. But to make matters worse, the faults of induction motors often progress through long time. It means that early diagnosis is very important. Many researches have been progressed and general method of diagnosis is using vibration sensor to diagnose fault of induction motor. However, although it is reliability technique, it demands high price and it is difficult to use. This paper presents an implementation of technique for fault diagnosis of induction motor using wavelet transform based stator current and it is composed with algorithm that decides whether fault existence or not using C++ based on windows software. The algorithm will be accomplished in real-time using current data acquisition board and PC automatically with Neural Network algorithm.

  • PDF

Gap Control Using Discharge Pulse Counting in Micro-EDM (미세 방전 가공에서의 방전 펄스 카운팅을 이용한 간극 제어)

  • Jung J.W.;Ko S.H.;Jeong Y.H.;Min B.K.;Lee S.J.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.499-500
    • /
    • 2006
  • The electrode wear in micro-EDM significantly deteriorates the machining accuracy. In this regard, electrode wear needs to be compensated in-process to improve the product quality. Therefore, there are substantial amount of research about electrode wear. In this study a control method for micro-EDM using discharge pulse counting is proposed. The method is based on the assumption that the removed workpiece volume is proportional to the number of discharge pulses, which is verified from experimental results analyzing geometrically machined volume according to various number of discharges. Especially, the method has an advantage that electrode wear does not need to be concerned. The proposed method is implemented to an actual micro-EDM system using high speed data acquisition board, simple counting algorithm with 3 axis motion system. As a result, it is demonstrated that the volume of hole machined by EDM drilling can be accurately estimated using the number of discharge pulses. In EDM milling process a micro groove without depth variation caused by electrode wear could be machined using the developed control method. Consequently, it is shown that machining accuracy in drilling and milling processes can be improved by using process control based on the number of discharge pulses.

  • PDF

Sleep Management Pillow System (수면 관리 베개 시스템)

  • Ahn, Dohyun;Tran, Minh;Park, Jaehee
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.20 no.4
    • /
    • pp.212-217
    • /
    • 2019
  • In this paper, a sleep management pillow system for snoring detection and respiration measurement is investigated. The sleep management pillow system consists of four force sensing resistor(FSR) sensors, two microphones(MIC), a pillow, a measurement system. Four FSR sensors attached at the bottom part of the pillow are used for respiration measurement and snoring detection. Two microphones located at the middle left and right of the pillow are utilized for only snoring detection. The respiration and the snoring of ten young people were measured using the sleep management pillow system composed of a data acquisition board, interface circuit, and personal computer. The measurement accuracy of the respiration was about 98% and the measurement accuracy of the snoring was about 97%. The experiment results show that the sleep management pillow system can be used for snoring detection and respiration rate measurement during sleeping.

Rapid Prototyping of Head-of-Bed Angle Measurement System using Open-Source Hardware (오픈소스하드웨어를 이용한 침상머리각도 측정 시스템의 래피드 프로토타이핑)

  • Jo, Bong-Un;Park, Yeong-Sang;Seo, Sugkil;Kim, Jin-Geol;Lee, Young-Sam
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.21 no.11
    • /
    • pp.1038-1043
    • /
    • 2015
  • When the study on the relationship between the Head-of-Bed (HOB) angle and ventilator-associated pneumonia is performed, the fact that the HOB angle can only be measured intermittently imposes a significant limitation on the study. Therefore, there has been demand for the development of a device that can measure the HOB angle continuously. In this paper, we propose the rapid prototyping of an HOB measurement system using open-source hardware and software. The proposed system helps to maintain the HOB angle at a particular angle by displaying the angle and helps the medical study of pneumonia patients by enabling continuous data acquisition. Firstly, we eliminate the process of making an MCU board by utilizing an open-source hardware mbed LPC1768. Secondly, we reduce the software development time by using libraries and hence enabling the easy use of peripherals. Thirdly, for rapid prototyping, we build the enclosure of the proposed system using a 3D printer. The proposed system can be attached and detached to and from a bed. Therefore, we can attach it to the bed of a patient for whom measurement of the HOB angle is necessary. Finally, we check the measurement performance and the validity of the proposed system through an experiment utilizing an incremental encoder.

Condition Monitoring and Fault Diagnosis System of Rotating Machinery (회전기기의 상태감시 및 결함탐지 시스템)

  • Jeong, Sung-Hak;Lee, Young-Dong
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2016.10a
    • /
    • pp.819-820
    • /
    • 2016
  • Electrical power distribution is consists of high voltage, low voltage and motor control center(MCC). Motor control centers involves turning the motor on and off, it is configured electronic over current relay to detect a motor overcurrent flows. Existing electronic over current relay detects electrical fault such as overcurrent, undercurrent, phase sequence, negative sequence current, current unbalance and earth fault. However, it is difficult to detect mechanical fault such as locked rotor, motor stator and rotor and bearing fault. In this paper, we propose a condition monitoring and fault diagnosis system for electrical and mechanical fault detection of rotating machinery. The proposed system is designed with signal input and control part, system interface part and data acquisition board for condition monitoring and fault diagnosis, it was possible to detect electrical fault and mechanical fault through measurement and control of insulation resistance, locked rotor, MC counter and bearing temperature.