• Title/Summary/Keyword: Data Recording

Search Result 1,095, Processing Time 0.032 seconds

Holographic Data Storage System using prearranged plan table by fuzzy rule and Genetic algorithm

  • Kim, Jang-Hyun;Kim, Sang-Hoon;Yang, Hyun-Seok;Park, Jin-Bae;Park, Young-Pil
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.1260-1263
    • /
    • 2005
  • Data storage related with writing and retrieving requires high storage capacity, fast transfer rate and less access time. Today any data storage system cannot satisfy these conditions, however holographic data storage system can perform faster data transfer rate because it is a page oriented memory system using volume hologram in writing and retrieving data. System can be constructed without mechanical actuating part therefore fast data transfer rate and high storage capacity about 1Tb/cm3 can be realized. In this research, to reduce errors of binary data stored in holographic data storage system, a new method for bit error reduction is suggested. First, find fuzzy rule using experimental system for Element of Holographic Digital Data System. Second, make fuzzy rule table using Genetic algorithm. Third, reduce prior error element and recording Digital Data. Recording ratio and reconstruction ratio will be very good performance

  • PDF

A Study on the Space Programming of the Medical Recording Department in the General Hospital (종합병원 의무기록부의 규모계획에 관한 연구)

  • Ryu, Jae-Kwon;Lee, Nak-Woon
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.3 no.4
    • /
    • pp.27-34
    • /
    • 1997
  • This study aims at proposing the basic architectural data of the medical recording department for the general hospital planning and design. This research investigated the size of working space and the chart custody space through actual survey and the present conditions of space were analyzed. In result, this study proposes the formula for the calulation of the chart custody space according to computerization level and the chart custody planning year.

  • PDF

Rate 13/15 MTR code with j=2 constraint for high-density magnetic recording (고밀도 자기기록을 위한 j=2 구속 조건을 갖는 코드율 13/15인 MTR 코드)

  • 이규석;이주현;이재진
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.29 no.8C
    • /
    • pp.1034-1039
    • /
    • 2004
  • Since the major reason of the detection failure is from the consecutive data transitions, it is desirable to limit the MTR(maximum transition run) within two. Therefore, we propose a new MTR code that limits the MTR constraint to 2 and k-constraint to 8. In addition, DC-free coding is performed to overcome the media noise that exits in low frequency of perpendicular recording system. We use a GS (Guided Scrambling) for DC-free coding, and the performance of the code is compared with that of the rate 819 code used in the conventional recording channel by a computer simulation.

Improvement of Tracking Servo Performance in SIL based Near-field Recording using Disturbance Observer (외란 관측기를 이용한 근접장 기록 시스템의 트랙킹 서보 성능 향상)

  • Kang, Min-Seok;Kim, Joong-Gon;Shin, Won-Ho;Jeong, Jun;Park, No-Cheol;Yang, Hyun-Seok;Park, Young-Pil
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.609-612
    • /
    • 2008
  • The solid immersion lens (SIL) based near-field recording (NFR) system is considered as one of the high density optical data storage system. For the NFR servo system, tracking servo control is a difficult technology to maintain extremely small gap between SIL and media within one twentieth. This is because the track pitch is decreased for increasing the recording density. In this paper, we propose disturbance observer (DOB) and internal model principle (IMP) for disturbance rejection due to eccentricity of disk. The performance of tracking controller using DOB is increased by about 85%, 94%, 97% using Q filters that have bandwidths of 50Hz, 125Hz, 250Hz, respectively. Moreover, IMP based controller is effectively reduced the residual error.

  • PDF

Effect of temperature on the rheological properties of dental interocclusal recording materials

  • Pae, Ahran;Lee, Ho-Rim;Kim, Hyeong-Seob
    • Korea-Australia Rheology Journal
    • /
    • v.20 no.4
    • /
    • pp.221-226
    • /
    • 2008
  • The purpose of this study was to compare rheological properties of six dental interocclusal recording materials and to investigate the effect of temperature on the rheological properties during setting. Five polyvinylsiloxane materials and one polyether material were investigated in this study. The storage modulus (G') and the loss factor ($tan{\delta}$) were measured from 30s after mixing during setting, using the universal dynamic spectrometer. Viscoelastic properties were evaluated by means of G' and $tan{\delta}$ from 5 repeats at $21^{\circ}C$ and $33^{\circ}C$. Individual changes during setting were also evaluated. All data were statistically analyzed using one-way ANOVA and multiple comparison $Scheff{\acute{e}}$ test at the significance level of 0.05. The mean of G was checked at $t_{set}$ (the setting time provided from manufacturer) and $t_{300}$ (the end of experimental time) and the mean of $tan{\delta}$ was checked at to and $t_{set}$. Whereas the increase of the G' value showed generally exponential changes at $21^{\circ}C$, the change of the G' value at $33^{\circ}C$ displayed sigmoidal curves during setting. The change of loss factor $tan{\delta}$ during setting varied. Within the limitations of this study, dental interocclusal recording materials had different viscoelastic properties and most of the materials showed different fluidity at $21^{\circ}C$ and $33^{\circ}C$.

A study on ceramic shade prescriptions for work authorizations (도재 보철물 색조의 처방에 관한 고찰)

  • Sung, Hwan-Kyung
    • Journal of Technologic Dentistry
    • /
    • v.10 no.1
    • /
    • pp.177-183
    • /
    • 1988
  • This paper aims to examine ceramic shade prescriptions for work authorizations in all its aspectclincal information, recording information, technical considerations, extended application, practical applications. The results are as follows : 1. The basic application provides essential data for ceramic veneer fabrication. 2.Three-dimensional information divides the space for body and enamel components. 3. The second body shade selection improves shade matching in the middle one-third of the tooth and enhences the appearance of the enamel component. 4. Ceramists are encouraged to recognize the influence each component has upon the total shade composition. 5. A format is established for recording clinical information. 6. The use of available ceramic systems is seemingly unlimited. The method presented provides flexisility for recording the most detailed shade information in simple graphic and verbal terms. 7. Technical simplification is a by-product of complete, precise work information.

  • PDF

An Implementation of On-line Recording for TDX-10A Switching System (TDX-10A 온라인 녹음기능 구현방안 연구)

  • 김태원;류영일이성근
    • Proceedings of the IEEK Conference
    • /
    • 1998.10a
    • /
    • pp.293-296
    • /
    • 1998
  • When the information of announcement facility is modified or added, they are recorded on a tape and then are updated manually using the cassette tape recorder at each office. But the degrade of the tone quality owing to repeated use of the tape and some recording mistakes by processing manually deteriorate the quality of service. And new services such as IN(Intelligent Network) and added functions make the announcement changed very often. Therefore the improved skill of the announcement handling is needed. This paper introduces the implementation of the TDX-10A on-line recording function of transferring voice in PCM data file and storing it in the memory of the recorded announcement facility, when message is recorded onthe fixed type of announcement facility.

  • PDF

Nano-wear Characteristics of Silicon Probe Tip for Probe Based Data Storage Technology (탐침형 정보저장 기술을 위한 실리콘 탐침의 나노 마멸 특성에 관한 연구)

  • 이용하;정구현;김대은;유진규;홍승범
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.10a
    • /
    • pp.552-555
    • /
    • 2004
  • The reliability issue of the probe tip/recording media interface is one of the most crucial concerns in the Atomic Force Microscope (AFM)-based recording technology. In this work, the tribological characteristics of the probe/media interface were investigated by performing wear tests using an AFM. The ranges of applied normal load and sliding velocity for the wear test were 10 to 50nN and 2 to 20$\mu$m/s respectively. The damage of the probe tip was quantitatively as well as qualitatively characterized by Field Emission Scanning Probe Microscope (FESEM) analysis and calculated based on Archard s wear equation. It was shown that the wear coefficient of the probe tip was in the order of 10$^{-4}$ ~ 10$^{-3}$ , and significant contamination at the end of the probe tip was observed. Thus in order to implement the AFM-based recording technology, tribological optimization of the probe/media interface must be achieved.

  • PDF

Finite Element Analysis of Perpendicular Magnetic Recording System by Using PREISACH Model (PREISACH모델을 이용한 수직자기기록장치의 유한요소 해석)

  • 박관수;이형범;한송엽;정현교;이택동
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.40 no.3
    • /
    • pp.258-265
    • /
    • 1991
  • In this paper, perpendicular magnetic recording system which consists of a single pole head and a double layer medium has been analyzed by using 2D-finite element method and preisach model for describing hysteresis characteristics. To verify the validity of this method, we compare the calculated magnetic field intensity which is above the isolated transition of magnetization with scaled up experimental data published in reference [7]. The results show good agreements within 7% error bounds and it is therefore concluded that this method will be very useful to analyze perpendicularmagnetic recording system with hysteresis characteristics.

Performance Evaluation of Skewed Read-Head for Shingled Magnetic Recording (트랙을 겹쳐서 쓰는 자기기록 방식에서 리드헤드가 틀어진 경우의 성능 분석)

  • Kim, Byungsun;Lee, Jaejin
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.39A no.9
    • /
    • pp.514-518
    • /
    • 2014
  • The shingled magnetic recording method has interference between adjacent tracks. Furthermore, when read-head reads the data along the track, the head can be skewed by some physical effects. In this paper, in order to solve this problem, we propose a two-dimensional equalizer that uses two heads. If the head is skewed, it is possible to complement the performance by positioning the two heads at the center of the current track.