• 제목/요약/키워드: Data Diode

검색결과 362건 처리시간 0.024초

녹색광을 이용한 반사형 광용적맥파측정기의 주변광 간섭시 신호측정 (The Verification of Photoplethysmography Using Green Light that Influenced by Ambient Light)

  • 장기영;고현철;이정직;윤영로
    • 대한의용생체공학회:의공학회지
    • /
    • 제35권5호
    • /
    • pp.125-131
    • /
    • 2014
  • The purpose of this study is to verify the utility of reflected photoplethysmography sensor using two green light emitting diodes that influenced by ambient light. Recently it has been studied that green light emitting diode is suitable for light source of reflected photoplethysmography sensor at low temperature and high temperature. Another study showed that, green light is better for monitoring heart rate during motion than led light. However, it has a bad characteristic about ambient light noise. To verify the utility of reflected photoplethysmography sensor using green light emitting diode, this study measures the photoplethysmography signal that is distorted by ambient light and will propose a solution. This study has two parts of research method. One is measurement system that composed sensor and board. The sensor is made up PE-foam and Non-woven fabric for flexible sensor. The photoplethysmography signal is measured by measurement board that composed high-pass filter, low-pass filter and amplifier. Ambient light source is light bulb and white light emitting diode that has three steps brightness. Photoplethysmography signal is measured with lead II electrocardiography signal at the same time and it is measured at the finger and radial artery for 1 minute, 1000 Hz sampling rate. The lead II electrocardiography signal is a standard signal for heart rate and photoplethysmography signal that measured at the finger is a standard signal for waveform. The test is repeated 3 times using three sensor. The data is processed by MATLAB to verify the utility by comparing the correlation coefficient score and heart rate. The photoplethysmography sensor using two green light emitting diodes is shown better utility than using one green light emitting diode and red light emitting diode at the ambient light. The waveform and heart rate that measured by two green light emitting diodes are more identical than others. The amount of electricity used is less than red light emitting diode and error peak detectability factor is the lowest.

자궁경부암 환자에서 In vivo dosimetry(Diode detector)를 이용할 직장선량의 측정 (Measurement of Rectal Rodiation dose in the Patients with Uterine Cervix fencer using In Vivo Dosimetry(Diode Detector))

  • 김성기;김완선
    • 대한방사선치료학회지
    • /
    • 제16권1호
    • /
    • pp.29-37
    • /
    • 2004
  • 목적 : 자궁경부암 환자의 고선량률 근접치료 시 부작용을 줄이기 위해 가장 주의 깊게 선량을 고려해야 할 곳은 직장과 방광이다. 일반적으로 직장이나 방광에서의 선량값은 Planning장치의 계산값에만 의존하고 있는 상태이고, TLD를 이용한 직장 선량분석은 보고된 바 있으나 In vivo dosimetry(Diode detector)를 이용한 보고는 거의 없었다. 본 연구에서는 자궁경부암 환자치료 시 매번 diode detector를 직장 내에 삽입하여 직장 선량을 측정하고 측정된 값을 토대로 직장의 부작용을 줄이는데 기초 자료로 활용 하고자 하였다. 대상 및 방법 : 2003년 2월부터 2003년 6월까지 Ir-192 동위원소 고선량률 근접치료기로 치료받은 자궁경부암환자 6명(tandem and ovoid 4명, cylinder 1명, tandem and cylinder 1명)을 대상으로 총 28회 측정을 실시하였고 직장내 Diode detector를 매번 측정 시마다 anterior, lateral film을 동일한 지점에서 촬영 후, Planing을 실시하여 측정값과 비교해 보았다. 결과 : 4명의 tandem md ovoid에서 3명의 직장내 Diode detector측정값의 평균과 편차는 $274.1{\pm}13.4cGy$이고 1명의 tandem and ovoid에서 $126.1{\pm}7.2cGy$, cylinder에서 $99.7{\pm}7.1cGy$, tandem and cylinder에서 $77.7{\pm}11.5cGy$이었다. 결론 : 직장의 매 측정 시마다 Diode detector측정값은 직장의 상태에 따라 표준편차가 매우 크므로 단 한번의 치료계획 계산 값으로 직장의 부작용을 예측하는 것은 어렵다. 본 연구에서 얻어진 결과로 볼 때 가능하다면 TLD 또는 In vivo dosimetry 장비를 이용하여 치료 시마다 실측하여 직장의 부작용을 판단하는 것이 중요하며 직장의 부작용이 예상될 시 gauze packing 및 조사시간을 조절하거나 shielded된 기구를 사용하여 직장의 선량을 낮추도록 하는 것이 필요하다고 사료된다.

  • PDF

반도체레이져를 이용한 온도 및 농도의 계측 (Temperature and Concentration measurement using Semi-conductor diode laser)

  • 정대헌;노동순;지전유이
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2000년도 제21회 KOSCO SYMPOSIUM 논문집
    • /
    • pp.168-174
    • /
    • 2000
  • A diode laser sensor system based on absorption spectroscopy techniques has been developed to measure $CO_2$ concentration and temperature non-intrusively in high temperature combustion environments using a 2.0 ${\mu}m$ DFB(Distributed Feedback) laser. Two optics was fabricated in pig-tail fashion and all optical components were implemented in a single box. The evolution of measurement sensitivity was done using test cell by changing sweep frequency and $CO_2$ concentration. Gas temperature was determined from the ratio of integrated line strengths. Species concentration was determined from the integrated line intensity and the measured temperature. The result show that the system has 2% error in wide operation frequency range and accuracy of $CO_2$ concentration was about 3%. The system was applied to measure temperature and concentration in the combustion region of a premixed $CH_4$ +air triangular flame. The measurement results of gas temperature agreed well with thermocouple results. Many considerations were taken into account to reduce optical noise, etalon effect, beam steering and base line matching problem. The evaluations results and actual combustion measurement demonstrate the practical and applicability for in-situ and real time combustion monitoring in a practical system.

  • PDF

구동 TFT 편차 보상을 위한 전압 피드백 AMOLED 디스플레이 구동 회로 (Voltage Feedback AMOLED Display Driving Circuit for Driving TFT Deviation Compensation)

  • 손기성;조용수;손상희
    • 반도체디스플레이기술학회지
    • /
    • 제22권4호
    • /
    • pp.161-165
    • /
    • 2023
  • This paper designed a voltage feedback driving circuit to compensate for the characteristic deviation of the Active Matrix Organic Light Emitting Diode driving Thin Film Transistor. This paper describes a stable and fast circuit by applying charge sharing and polar stabilization methods. A 12-inch Organic Light Emitting Diode with a Double Wide Ultra eXtended Graphics Array resolution creates a screen distortion problem for line parasitism, and charge sharing and polar stabilization structures were applied to solve the problem. By applying Charge Sharing, all data lines are shorted at the same time and quickly positioned as the average voltage to advance the compensated change time of the gate voltage in the next operation period. A buffer circuit and a current pass circuit were added to lower the Amplifier resistance connected to the line as a polar stabilization method. The advantage of suppressing the Ringing of the driving Thin Film Transistor can be obtained by increasing the stability. As a result, a circuit was designed to supply a stable current to the Organic Light Emitting Diode even if the characteristic deviation of the driving Thin Film Transistor occurs.

  • PDF

Pierce 다이오드에서 플라즈마의 비선형 동력학적 거동 (Nonlinear Dynamical Behavior of Beam-Plasma in the Pierce Diode)

  • 고욱희;박인호
    • 한국진공학회지
    • /
    • 제21권5호
    • /
    • pp.249-257
    • /
    • 2012
  • 1차원 유체 모델을 사용하는 수치 코드를 개발하여 Pierce 다이오드에서 플라즈마에 대한 비선형 동력학적 거동을 연구하였다. Pierce 다이오드에서 플라즈마는 전극에서 방출되는 전자 전류와 전극 사이의 거리로 결정되는 Pierce 매개 변수가 변화함에 따라 안정하기도 하고 불안정해지기도 한다. 중성 및 비중성 Pierce 시스템의 동력학적 특성에 대해 해석적 및 수치적으로 연구하였다. Pierce 매개 변수의 값에 따라 플라즈마는 증폭 모드 또는 진동 모드를 가질 수 있으며, 진동 모드에서는 매개 변수가 감소함에 따라 계속적인 주기 배가 쌍갈림(period doubling bifurcation)을 일으키며 카오스 상태에 도달하게 된다. 이러한 거동에 대한 분석은 보다 복잡한 구조에서의 빔-플라즈마 상호작용에 대한 기본적인 이해를 위한 모델 및 카오스 제어를 위한 자료로서 사용될 수 있다.

I-V 특성곡선을 통한 태양전지 패널의 모델 파라미터 추출 방법 (Analytical Methods for the Extraction of PV panel Single-Diode model parameters from I-V Characteristic)

  • 최성원;류지형;이창구
    • 한국산학기술학회논문지
    • /
    • 제12권2호
    • /
    • pp.847-851
    • /
    • 2011
  • 태양광 발전 시스템은 친환경성을 바탕으로 설치용량이 증가하고 있으며 효율 개선을 위한 연구가 활발하다. 고 효율 시스템 설계를 위해서는 태양전지 패널의 출력특성을 정확히 파악하는 것이 중요하다. 태양전지 패널은 단일 다이오드 모델로 물리적 특성을 표현할 수 있으나, 정확한 파라미터를 얻는 것은 여러 단계의 측정과 수치해석 등의 복잡한 과정을 거쳐야 한다. 본 논문에서는 패널 제조사의 데이터 시트에 제공되는 태양전지 패널의 I-V 특성곡선을 기반으로 패널의 단일 다이오드 모델의 특성 파라미터를 추출하는 방법을 제시하였다. 제시한 방법의 검증을 위하여, Simulink의 Solar Cell 블록에 추출한 파라미터를 입력하여 출력을 측정하고, 데이터 시트와 오차를 계산하였다.

레이저 다이오드를 이용한 수중 광 정보 및 전력 동시전송 (Underwater Simultaneous Light Information and Power Transmission using a Laser Diode)

  • 김성만;신재우
    • 한국전자통신학회논문지
    • /
    • 제17권5호
    • /
    • pp.853-858
    • /
    • 2022
  • 본 논문에서는 레이저 다이오드를 활용하여 수중 광 전력과 수중 광 무선통신의 동시전송을 연구하고 이에 대한 실험 결과를 보인다. 본 실험에서는 송신부에 전/광 변환을 위한 레이저 다이오드를 사용하고 수신부에는 광/전 변환을 위한 태양전지를 사용하였다. 수중 전송 실험을 위해서는 플라스틱 관에 물을 채워 구현하였으며, 수중 광 무선통신 및 수중 광 무선충전을 위해 레이저 송신단과 수신단 시스템을 최적화하였다. 본 실험에서는 100 mW 급 레이저를 사용하였으며, 레이저의 최대 전/광 변환효율을 18.5 % 였다. 수중 광 무선충전 및 수중 광 무선통신의 동시전송 실험결과, 수중에서 최대 5 m 전송시에 0.33 %의 DC-to-DC 전송효율을 보였으며, 수중 무선 광통신은 수중에서 1 m 전송시에 최대 50 kbps의 전송속도를 보였다.

Study of Modulation Effect in Integrated Interface Under Controlling Switching Light-Emitting Diode Lighting Module

  • Hong, Geun-Bin;Jang, Tae-Su;Kim, Yong-Kab
    • Transactions on Electrical and Electronic Materials
    • /
    • 제12권6호
    • /
    • pp.253-257
    • /
    • 2011
  • This study was carried out to solve problems such as radio frequency band depletion, confusion risk, and security loss in existing visible wireless communication systems, and to determine the applicability of next-generation networks. A light-emitting diode (LED) light communication system was implemented with a controlling switching light module using the ATmega16 micro-controller. To solve the existing modulation effect and disturbance in visible light communication, an integrated interface was evaluated with a driving light module and analyzes its reception property. A transmitter/receiver using the ATmel's micro-controller, high-intensity white LED-6 modules, and infrared sensor KSM60WLM and visible sensor TSL250RD were designed. An experiment from the initial value of distance to 2.5 m showed 0.46 V of the voltage loss, and if in long distance, external light interference occurred and light intensity was lost by external impact and thus data had to be modified or reset repeatedly. Additionally, when we used 6 modules through the remote controller's lighting dimming, data could be transmitted up to 1.76 m without any errors during the day and up to 2.29 m at night with around 2~3% communication error. If a special optical filter can reduce as much external light as possible in the integrated interface, the LED for lighting communication systems may be applied in next generation networks.

DFB 반사기가 집적된 다중전극 레이저 다이오드를 이용한 RZ 및 NRZ 데이터 신호의 광클럭 재생 (Optical Clock Recovery from RZ and NRZ data using a Multi-Section Laser Diode with a DFB Reflector)

  • 전민용;임영안;김동철;심은덕;김성복;박경현;이대수
    • 한국광학회지
    • /
    • 제17권1호
    • /
    • pp.68-74
    • /
    • 2006
  • DFB 반사기가 집적된 다중전극 레이저 다이오드에 Return-to-zero (RZ) pseudorandom bit sequence (PRBS) 데이터와 nonreturn-to-zero (NRZ) PRBS 데이터를 주입하여 이 신호로부터 광 클럭 신호를 추출하였다. 11.727 Gbit/s RZ PRBS 데이터와 NRZ PRBS 데이터로부터 재생된 광 클럭의 root-mean-square (rms) 타이밍 지터 (timing jitter)는 약 1 ps 정도로써 아주 우수한 결과를 얻어냈다. NRZ PRBS 데이터로부터 pseudo return-to-zero (PRZ) 데이터로 포맷변환을 구현하고, 클럭 성분을 갖고 있는 PRZ 신호를 이용하여 광 클럭을 추출하였다. 입력 PRZ데이터 신호의 rms 타이밍 지터는 2ps 이상일지라도 이로부터 추출해 낸 광 클럭의 rms 타이밍 지터는 1ps 정도의 좋은 특성을 얻어냈다.

Dynamics of RNA Bacteriophage MS2 Observed with a Long-Lifetime Metal-Ligand Complex

  • Kang, Jung Sook;Yoon, Ji Hye
    • Journal of Photoscience
    • /
    • 제11권1호
    • /
    • pp.35-40
    • /
    • 2004
  • [Ru(2,2'-bipyridine)$_2$(4,4'-dicarboxy-2,2'-bipyridine)]$^{2+}$(RuBDc) is a very photostable probe that possesses favorable photophysical properties including long lifetime, high quantum yield, large Stokes' shift, and highly polarized emission. To evaluate the usefulness of this luminophore (RuBDc) for studying macromolecular dynamics, its intensity and anisotropy decays when conjugated to RNA bacteriophage MS2 were examined using frequency-domain fluorometry with a high-intensity, blue light-emitting diode (LED) as the modulated light source. The intensity decays were best fit by a sum of two exponentials, and the mean intensity decay time was 442.2 ns. The anisotropy decay data showed a single rotational correlation time (2334.9 ns), which is typical for a spherical molecule. The use of RuBDc enabled us to measure the rotational correlation time up to several microseconds. These results indicate that RuBDc can be useful for studying rotational diffusion of biological macromolecules.s.

  • PDF