• Title/Summary/Keyword: Data Diode

Search Result 362, Processing Time 0.027 seconds

Micro Thermal Design of Swing-Arm Type Small Form Factor Optical Pick-up System (스윙 암 타입 초소형 광 픽업 시스템의 방열 설계)

  • Lee, Jee-Na;Kim, Hong-Min;Kang, Shin-Ill;Sohn, Jin-Seung;Lee, Myung-Bok
    • Transactions of the Society of Information Storage Systems
    • /
    • v.2 no.1
    • /
    • pp.21-25
    • /
    • 2006
  • The new multimedia information environment requires smaller optical data storage systems. However, one of the difficulties encountered in designing small form factor(SFF) optical pick-up is to emit the heat which is generated from laser diode(LD). Heat generated at the LD can reduce the optical performance of the system and the lifetime of LD. Therefore, it is important to include the thermal design in the design stage of SFF optical pick-up system for high performance and the longer lifetime of LD, and furthermore, to analyze the thermal characteristics of LD in detail micro heat transfer analysis is necessary. In the present study, micro heat transfer analysis was performed using the finite element method for the $28{\times}11{\times}2mm^3$ super slim swing-arm type optical pick-up actuator for Blu-ray disk. Two different materials were used for a swing-arm; a double layer polycarbonate/steel structure and a single aluminum structure.

  • PDF

Chlorosmaridione; A Novel Chlorinated Diterpene Quinone Methide from Rosemarinus officinalis L.

  • El-Lakany, Abdalla M.
    • Natural Product Sciences
    • /
    • v.10 no.2
    • /
    • pp.59-62
    • /
    • 2004
  • A novel chlorinated diterpene quinone methide; chlorosmaridione (7-chloro-11-hydroxy-abeita-7,9(11),13-triene-6,12-diode) was isolated from petroleum ether extract of the stems of Rosemarinus officinalis L. growing in Egypt. In addition, ${\beta}-sitosterol$, stigmasterol, lupeol acetate, ${\alpha}-amyrin,\;{\beta}-amyrin$, lupeol, acetyloleanolic acid, acetylursolic acid taxodione, horminone, and cryptotanshinone were also identified. Chemical structures of the isolated compounds have been elucidated on the bases of physical, chemical, and spectral data including IR, UV, MS, 1D-and 2D-NMR spectra.

DVD Technology : The Heart of Optical Data Storage Media (광기록 매체의 새로운 지평을 여는 DVD기술)

  • 김명룡
    • Electrical & Electronic Materials
    • /
    • v.10 no.3
    • /
    • pp.289-294
    • /
    • 1997
  • 디지탈 비디오 디스크의 약어로 지칭되는 DVD는 현대 과학이 이루어낸 레이저 광에 의한 정보의 기록과 재생을 한층 승화시킨 차세대 package형 광 기록 매체이다. 앞으로 이 제품군은 기존에 분리되어 있던 가전과 컴퓨터의 응용분야를 이어주는 교량역할을 할 새로운 개념의 상품으로 기대된다. 본 고에서는 DVD의 기술적 배경 및 이의 구현을 위해 활용된 요소기술, 그리고 미래기술로의 흐름에 관해 소개고자 한다.

  • PDF

1km Optical fiber transmission and free space characteristics of the PQR laser (PQR 레이저의 1km 광섬유 전송 및 자유공간 특성)

  • 김무성;곽규섭;김준연;김무진;권오대
    • Proceedings of the IEEK Conference
    • /
    • 1999.11a
    • /
    • pp.322-325
    • /
    • 1999
  • We report fiber guiding experiments on the Photonic Quantum Ring(PQR) laser diode. In the 1km transmission measurements, we find that the PQR performs much better than the VCSEL. This suggests that the PQR laser is very promising candidate for LAN-range optical data communications. On the other hand, we have also fabricated 8$\times$8 PQR laser arrays and measured spatial decays for free space properties without using any guiding optics, which showed about 1m distance of spectral angle sensing.

  • PDF

Planar Active Rectrodirective Array With Subharmonic Phase Conjugation Mixers

  • Kim Gi-Rae;Park Ji-Yong
    • Journal of information and communication convergence engineering
    • /
    • v.2 no.3
    • /
    • pp.153-156
    • /
    • 2004
  • A planar active retrodirective four-element array with subharmonic phase conjugation mixers based on anti-parallel diode pairs (APDPs) is proposed. As compared to previous phase conjugation mixers using twice RF frequency for LO frequency, the proposed conjugation mixers need only half RF frequency so that it can be easily applied for millimeter-wave applications. Receiving, transmitting, local oscillator, and intermediate frequencies are 5.79, 5.81, 2.9 GHz, and 10 MHz. Monostatic RCS and Bistatic RCS measurements at source locations of $0^{\circ},\;-20^{\circ},\;and\;28^{\circ}$ show good agreement with the calculated data.

Development of Dispenser System with Electrohydrodynamic and Voice Coil Motor for White Light Emitting Diode (백색 LED 제조를 위한 정전기력과 보이스코일모터를 이용한 디스펜서 시스템 개발)

  • Kang, Dong-Seong;Kim, Ki-Beom;Ha, Seok-Jae;Cho, Myeong-Woo;Lee, Woo-Jung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.10
    • /
    • pp.6925-6931
    • /
    • 2015
  • LED(Light Emitting Diode) is used in various filed like a display because of low power consuming, long life span, high brightness, rapid response time and environmental-friendly characteristic. General fabrication method is combination blue light LED chip with yellow fluorescent substance. Because this way is suitable for industry field in terms of convenience, economic, efficiency. In white light LED packaging process, encapsulation process that is dispensing fluorescent substance with silicon to blue light LED chip is most important. So, in this paper we develop EHD pump system using voice coil motor and electrostatic pump for dispensing fluorescent substance. For these things we conduct basic test about liquid surface profiles by voltage and process time. Through this data we decide optimal process condition and verify the optimal condition using design of experiment method. And to confirm uniformity of the condition, we conduct repeat dispensing test.

Performance Evaluation of Lead (II) Oxide Dosimeter for Digital Quality Assurance in Brachytherapy (방사선 근접치료의 디지털 정도관리를 위한 Lead (II) Oxide 선량계 성능 평가)

  • Han, Moo-Jae;Yang, Seung-Woo;Park, Sung-Kwang
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.4
    • /
    • pp.429-435
    • /
    • 2021
  • In intracavitary radiotherapy, incorrect location of the source can cause excessive dose to normal tissue, so it is essential to evaluate the location accuracy of the source. In this study, basic research was performed on digital line dosimeter based on lead (II) oxide (PbO) to improve analog verification method. Therefore, a polycrystalline PbO unit cell dosimeter was manufactured and the measurement performance for Ir-192 sources was evaluated. As a result, the reproducibility satisfies the evaluation criteria of 1.5% with a relative standard deviation of 0.85%. Linearity showed excellent results with a linear coefficient of R2 of 0.9998. In the case of distance dependence evaluation, the power function R2 showed 0.9855 for PbO and 0.9974 for diode, and the overall average difference was 1.66% for PbO and 2.18% for diode. This study presents the basic detection performance of the polycrystalline PbO dosimeter for the Ir-192 source and can provide basic data in the field of radiation measurement.

디지탈 X선 촬영술의 기술 발전과 전망

  • 민병구
    • 전기의세계
    • /
    • v.34 no.9
    • /
    • pp.548-552
    • /
    • 1985
  • 서울대학교 병원에서는 약2년간의 이분야에 대한 기초 및 임상연구 결과를 토대로 하여 D.S.R.System을 개발하고 있다. 현재 개발하고 있는 Systme은 다음과 같다. 1) X선 발생장치 및 Control부분 2) 산란효과 제거를 위한 fore-slit 및 after-slit과 구동장치 3) X선을 광신호로 변환하기 위한 rare earth screen과 광신호를 전기적인 신호로 변환시키기 위한 photo-diode array detector의 결합체, 4) data 수집부분, 증폭장치와 A/D변환기, 고속 data 저장용 기억장치 부분 5) data 처리와 display를 위한 Bit-slice processor 5) Picture Archiving and Communication Systems (PACS) 이러한 부분 이외에 SNR을 향상시키고 좁은 부위의 region of interest를 보다 정확하게 관찰하기 위해서 511p/mm의 고밀도 선형검출기를 병행으로 사용하고 있다. 이 선형검출기를 이용하여 일부의 영상을 관찰하여 그 결과를 Wiener filter 등의 방법의 매개변수 선정에 이용하여 전체적인 영상의 질을 향상시키고자 하는 것이다.

  • PDF

The Design of Optical Marker for Auto-registering of 3D scan data (3차원 스캐너의 레지스터링 문제 해결을 위한 광학식 마커 설계)

  • 손용훈;양현석
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.256-259
    • /
    • 2003
  • This paper proposes OPTICAL MARKER fer registering process - one of the 3D measurement process : scan registering - merging - measurement. If the registering work is carried out manually, it can be accompanied with much time and many errors. Because the patterned marker make registering process automatic, many firms use it now. But the physical shape of existing markers is the source of the data loss caused by hiding surface, and the marker arrangement is the source of the time loss. The optical marker proposed in this paper has marker generator, organized a large number of binary coded control laser diode, separate from 3D scan object. So, it does not take much time for the marker disposition, and it is not the origin of the data loss, and the binary coded laser information make the auto-registering possible.

  • PDF

A Study of the Real-time Sensing by the Optical Current Sensor for GIS

  • Park, Won-Zoo;Kim, Yeong-Min
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.7
    • /
    • pp.75-80
    • /
    • 2009
  • In this study, a Web server was constructed using LabVIEW's DataSocket, which makes possible acquisition, analysis, and saving in real time. The output value of the optical current sensor at the web server PC was measured and the output value was displayed using the Web browser of the client PC. DataSocket by LabVIEW makes the construction of a Web server easier than other languages and is compatible with other application programs. An optical current sensor was composed using a 1310 [nm] laser diode, and 9/125 [${\mu}m$] standard single mode optical fiber and was created to be a close type sensor. Data measurement using Web servers has the advantage of monitoring electric power systems at a great distance and can fuse IT technology and electric power systems. Also, this measurement uses inexpensive mounting and programming when compared to existing measurement equipment allowing the construction of a measurement system in any situation or surrounding.