• Title/Summary/Keyword: Data Comparison

Search Result 12,608, Processing Time 0.046 seconds

Comparison and Decision of Exposure Coefficient for Calculation of Snow Load on Greenhouse Structure (온실의 적설하중 산정을 위한 노출계수의 비교 및 결정)

  • Jung, Seung-Hyeon;Yoon, Jae-Sub;Lee, Jong-Won;Lee, Hyun-Woo
    • Journal of Bio-Environment Control
    • /
    • v.24 no.3
    • /
    • pp.226-234
    • /
    • 2015
  • To provide the data necessary to determine exposure coefficients used for calculating the snow load acting on a greenhouse, we compared the exposure coefficients in the greenhouse structure design standards for various countries. We determined the exposure coefficient for each region and tried to improve on the method used to decide it. Our results are as follows: After comparing the exposure coefficients in the standards of various countries, we could determine that the main factors affecting the exposure coefficient were terrain roughness, wind speed, and whether a windbreak was present. On comparing national standards, the exposure coefficients could be divided into three groups: exposure coefficients of 0.8(0.9) for areas with strong winds, 1.0(1.1) for partially exposed areas, and 1.2 for areas with dense windbreaks. After analyzing the exposure coefficients for 94 areas in South Korea according to the ISO4355 standard, all of the areas had two coefficients (1.0 and 0.8), except Daegwallyeong (0.5) and Yeosu (0.6), which had one coefficient each. In South Korea, the probability of snow is greater inland than in coastal areas and there are fewer days with a maximum wind velocity > $5m{\cdot}s^{-1}$ inland. When determining the exposure coefficients in South Korea, we can subdivide the country into three regions: coastal areas with strong winds have an exposure coefficient of 0.8; inland areas have a coefficient of 1.0; and areas with dense windbreaks have an exposure coefficient of 1.2. Further research that considers the number of days with a wind velocity > $5m{\cdot}s^{-1}$ as the threshold wind speed is needed before we can make specific recommendations for the exposure coefficient for different regions.

Comparison of Germination Characteristics and Daily Seed Germinating Pattern in New Cultivars of The Third Generation of Creeping Bentgrass Grown under Alternative and Natural Room Temperature Conditions (자연실온 및 변온조건에서 제3세대 크리핑 벤트그래스 신품종의 발아특성 및 일일 발아패턴 비교)

  • Kim, Kyoung-Nam;Kwon, O-Dal;Shim, Sang-Ryul;Yoon, Jung-Seo;Park, So-Hyang
    • Asian Journal of Turfgrass Science
    • /
    • v.25 no.1
    • /
    • pp.1-10
    • /
    • 2011
  • This study was conducted to investigate early germination characteristics and germination pattern of new cultivars of creeping bentgrass (CB, Agrostis pall/stris Huds.) under natural room temperature conditions and to analyze differences between alternative and natural conditions. Seven cultivars of CB were tested in the study. Daily and cumulative germination patterns were measured and analyzed on a daily basis. Significant differences were observed in germination pattern, days to the first germination, days to 50% germination, days to 85% germination, and germination rate among cultivars under different environments. The first germination in all entries was initiated between 4 and 5 days after seeding (DAS) under alternative conditions, while between 6 and 8 DAS under natural conditions, being 2 to 3 days later as compared with that of alternative conditions. As for the first germination percentage, it was generally 5 to 25% under alternative conditions. However, 'Penn A-1', 'Penncross', and 'Penn A-4' cultivars showed a vigorous germination, producing 50 to 70%. Under natural room temperature conditions, it was 5 to 10% for the most entries, except 'Penncross', 'L-93', and 'Penn A-4' cultivars which vigorously produced 20 to 50%. Days to the 50% germination in CB resulted in 4 to 10 DAS under alternative conditions, while 6 to 15 DAS under natural conditions, being 2 to 5 days later than under alternative conditions. Days to the 85% germination were 5.90 to 11.75 DAS under alternative conditions and 7.95 to 12.50 DAS under natural conditions. 'Penn A-1' and 'L-93' were the fastest cultivars under alternative and natural conditions, respectively. Regardless of the temperature conditions, the longest cultivar in germination was 'T-1', being over 11 DAS. In-depth comparative data on germination characteristics and germination patterns among CB cultivars would be usefully applied for a practical CB turf establishment in golf course construction etc.

Comparison of Antidepressants Tolerability in Cancer Patients Referred for Psychiatric Consultation (정신건강의학과 자문 의뢰된 암 환자의 항우울제 내약성 비교 연구)

  • Ko, Eunmi;Park, Jin-Seong;Ha, Juwon;Lim, Sewon;Kim, Tae-Suk;Ha, Jee Hyun;Paik, Jong-Woo;Lee, Boung Chul;Choe, Byeong Moo;Lee, Kang-Joon;Kim, Sung-Wan;Yang, Jong-Chul;Ko, Young-Hoon;Oh, Kang-Seob
    • Korean Journal of Psychosomatic Medicine
    • /
    • v.21 no.1
    • /
    • pp.3-10
    • /
    • 2013
  • Objectives : Many patients diagnosed with cancer suffer from various psychiatric symptoms such as depression, anxiety and insomnia as well as cancer itself. Patients with cancer are more vulnerable to possible adverse events of psychotropic medications. Although antidepressants are widely used among cancer patients, there is little information about tolerability of antidepressants. This study was conducted to compare tolerability of antidepressants in cancer patients referred for psychiatric consultation. Methods : The participants were cancer patients who had been referred to psychiatrist for their psychiatric symptoms. We retrospectively analyzed the data of patients diagnosed with cancer from 9 general hospitals in Korea. The discontinuation rate for a 6 months period after treatment initiation for three antidepressants(Escitalopram, Mirtazapine, Paroxetine) were compared. Results : Antidepressants were prescribed for 96.3% of subjects and Escitalopram 150(47.2%), Mirtazapine 92(28.9%) and Paroxetine 76(23.9%) were prescribed frequently in order There were no significant differences in discontinuation rates among the three antidepressants during the 6 month period after initiation of pharmacotherapy. But there was a difference in discontinuation rates between inpatients versus outpatients(p<0.0001). Conclusions : In a naturalistic setting for the antidepressant treatment for cancer patients, it seems that there are no differences in discontinuation rates among these three antidepressants. It is therefore essential that such interactions are carefully considered when treating patients of antidepressants who already have cancer.

  • PDF

A Study of Eye Refractive Error of high school students in the North Kyoungki (경기북부지역 고등학생의 안굴절상태 조사 및 연구)

  • Choi, Hae Jung;Chen, Ko Hsien;Cha, Jung Won
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.5 no.1
    • /
    • pp.131-138
    • /
    • 2000
  • We compared the study of refractive error of the eyes done in 1998 with that reported three years ago at any high school in the north Kyungki. From the these data, the distribution of ammetropia was investigated. The study of refractive error for high school students was also compared with those reported before for the Adults and the middle school student. When the refractive error is refered to spherical equivalent, the 40.6% of the whole students examined above had emmetropia and the other part of them(59.4%) turned out to be ammetropia which is classified to 46.4% belonged to myopia and 13.0% belonged to hyperpia. The ratio of emmetropia for the students in 1998 is 4.4% lower, and the ratio of hyperopia is 4.3% lower, but the ratio of myopia for the students in 1998 is 8.7% higher than that for the student in 1995. In the kind of refracive error, it is classified that a simple myopia is shown to highest ratio as a 23.6% of 6143 eyes examined, a compound myopic astigmatism to the next high ratio as a 17.4%, a simple myopic astigmatism as 10.9%, a simple hyperopic astigmatism as 9.8%, a simple astigmatism as 7.1%, a compound hyperopic astigmatism as 2.2%, a mixed astigmatism as a 1.8%, respectively. The percentage of an astigmatism is a 69.6% of total eyes examined if Cyl-0.25 Dptr is included to an astigmatism. On the other hand. The percentage of an astigmatism is a 45.0% of total eyes examined if Cyl-0.25 Dptr is excluded to an astigmatism. In the kind of astigmatism, the number of students had an astigmatism with the rule is about 5.6 times than that of astigmatism against the rule. From the result of comparison the right eye with the left eye, the right eye of the students had more a myopic refractive error than the left eye, which is same as adults' case.

  • PDF

Comparison between Stimulus and Response AC/A Ratios for Each Phoria with Additional Spherical Power (사위별 가입렌즈에 따른 자극 AC/A비와 반응 AC/A비의 비교)

  • Lee, Se-Hee;Yu, Dong-Sik;Son, Jeong-Sik;Kwak, Ho-Weon
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.3
    • /
    • pp.345-351
    • /
    • 2014
  • Purpose: The accommodative response and the near horizontal phoria were examined with additional spherical power to analyze the stimulus and response AC/A ratios that suggest reference data for the binocular vision. Methods: The open-field autorefractometer (Nvision-K 5001, Shin nippon) and modified thorington method (MIM card; Muscle Imbalance Measure card, Bernell) at 40 cm were utilized to measure the accommodative response and the near horizontal phoria for 81 persons ($20.89{\pm}1.92$ years old) with additional spherical power. The stimulus and the response AC/A ratios were calculated by gradient AC/A method. Results: The exophoria group showed the highest accommodative response ($1.92{\pm}0.26D$) at 40 cm, followed by orthophoria group and esophoria group($1.72{\pm}0.26D$ and $1.62{\pm}0.42D$, respectively) Meanwhile, the esophoria group showed the biggest ocular deviation for the near ($23.24{\Delta}$) followed by the orthophoria group and exophoria group ($19.76{\Delta}$ and $15.14{\Delta}$, respectively). The biggest difference of the stimulus and the response AC/A ratios was $1.72{\Delta}$ for the exophoria group with -2.00 D, while the one was $3.43{\Delta}$ for the esophoria group with +1.00 D. There was a significant difference between AC/A ratios for the exophoria group with -2.00 D, -1.00 D and the esophoria group with +3.00 D, +2.00D, +1.00D and -1.00D. Conclusions: The difference between stimulus and response AC/A was greater when increased minus spherical power for the exophoria group, while it was greater when increased plus spherical power for the esophoria group. Furthermore, the difference for the esophoria group was a greater than the one for the exophoria group.

The prevalences of asthma and allergic diseases in Korean children (한국 소아알레르기 질환의 유병률)

  • Hong, Soo-Jong;Ahn, Kang-Mo;Lee, Soo-Young;Kim, Kyu-Earn
    • Clinical and Experimental Pediatrics
    • /
    • v.51 no.4
    • /
    • pp.343-350
    • /
    • 2008
  • Asthma and allergic diseases are one of the most common disorders in children. Due to its increased prevalence, as well as the increased morbidity and mortality from these diseases, asthma and allergic diseases have come to be recognized as a major worldwide public health issue. In addition, socioeconomic burden of asthma and allergic diseases has increased in Korea also. The International Study of Asthma and Allergies in Childhood (ISAAC) investigated the worldwide prevalence of asthma and other allergic diseases using simple standardized methods because of the comparison of asthma and allergic diseases between the countries. In Korea, several epidemiologic studies have been conducted to determine the prevalence of asthma in children. Although these studies showed increased prevalence of asthma among Korean children (from 3.4% in 1964 to 10.1% in 1989), these findings were based on data from small numbers of subjects. The first Nationwide Study of Asthma and Allergies in Korean Children, which utilized the Korean version of ISAAC written and video questionnaire, was conducted in 1995 and the second Nationwide Study of Asthma and Allergies in Korean Children was conducted in 2000, directed by the Korean Academy of Pediatric Allergy and Respiratory Diseases. We report here the prevalence of asthma and other allergic diseases in Korean children and adolescents, and show the changes that occurred over this 5 year period. We also describe the risk factors for development of these diseases in Korean children. We developed Korean versions of the ISAAC written (WQ) and video (AVQ) questionnaires for allergic diseases. In 1995, the enrolled population consisted of 25,117 children selected from 34 elementary school and 14,946 children selected from 34 middle school across the nation, the response rate was 94.8%. In 2000, 27,831 children selected from 34 elementary school and 15,214 children selected from 34 middle school, and the response rate was 96.4%. From these studies, we can confirm that increase of the prevalences of asthma, allergic rhinitis, and atopic dermatitis in Korea, except the prevalence of food allergy. Especially, the video questionnaire showed increases in the lifetime and 12 month prevalence rates of wheeze at rest, exercise-induced wheeze, nocturnal wheeze, nocturnal cough, and severe wheeze over this period of time in middle school children. In addition, the increase of prevalences of symptoms, diagnosis and treatment of atopic dermatitis was noted significantly. Risk factor analysis showed that body mass index (BMI), passive smoking and living with a dog or cat were associated with higher risk of wheeze. Also the occurrence of fever during infancy and the frequent use of antibiotics were associated with the risk of wheeze. In conclusion, during the 5 year period from 1995 to 2000, the prevalences of asthma, allergic rhinitis, and atopic dermatitis has increased in Korean children. BMI, passive smoking, living with a dog or cat, the fever episodes in infancy, and the frequent use of antibiotics in infancy are important risk factors to development of asthma and atopic dermatitis. In the near future, the birth cohort study will be needed to investigate the causes of this increase and the natural course of allergic diseases, then we develop the methods to control asthma and allergic diseases.

Effect of surfactant lavage in severe meconium aspiration syndrome (중증 태변 흡인 증후군에서 인공 폐표면활성제 세정요법의 효과에 관한 비교 연구)

  • Lee, Soon Min;Kim, He Min;Jeon, Ji Hyun;Park, Min Soo;Park, Kook In;Namgung, Ran;Lee, Chul
    • Clinical and Experimental Pediatrics
    • /
    • v.51 no.4
    • /
    • pp.367-371
    • /
    • 2008
  • Purpose : The surfactant dysfunction may play an important role in meconium aspiration syndrome (MAS). We aim to evaluate the effect of surfactant lavage in the treatment of term infants with MAS. Methods : The medical records of 15 neonates with severe MAS admitted at Yongdong Severance Hospital from 2005 to 2007 were reviewed and analyzed. Seven infants with severe MAS necessitating mechanical ventilation underwent tracheobronchial lavage with 20 mL/kg of diluted (5.3 mg phospholipid/mL) surfactant saline suspension ($Newfactan^{(R)}$). Data regarding clinical outcomes was assessed by comparison with 8 control infants with equally severe MAS retrospectively. Results : In the lavage group, radiological improvement was evident after 6 hours of treatment. The duration of artificial ventilation and duration of hospital day were also significantly shorten in the lavage group compared with the control group. The mean oxygen index, mean ventilation index improved significantly within the first 6 hours after treatment. No differences were found in the incidence of major complications and mortality between the two groups. Conclusion : The surfactant lavage seems to be an effective and safe method for treatment of severe MAS. A multicenter, large scaled randomized controlled trial is needed for further study.

Evaluation of the Breast plan using the TLD and Mosfet for the skin dose (열형광선량계(TLD)와 MOSFET을 이용한 유방암 방사선치료계획에 대한 피부선량 평가)

  • Kim, seon myeong;Kim, young bum;Bak, sang yun;Lee, sang rok;Jeong, se young
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.27 no.2
    • /
    • pp.107-113
    • /
    • 2015
  • Purpose : The measurement of skin dose is very important that treatment of breast cancer. On account of the cold or hot dose as compared with prescription dose, it is necessary to analyse the skin dose occurring during the various plan of the breast cancer treatment. At our hospital, we want to apply various analyses using a diversity of dosimeters to the breast cancer treatment. Subjectss and Methods : In the study, the anthropomorphic phantom is used to find out the dose difference of the skin(draining site), scar and others occurring from the tangential treatment plan of breast cancer. We took computed tomography scan of the anthropomorphic phantom and made plans for the treatment planing using open and wedge, Field-in-Field, Dose fluence. Using these, we made a comparative analysis of the dose date points by using the Eclipse. For the dose comparison, we place the anthropomorphic phantom in the treatment room and compared the measurement results by using the TLD and MOSFET on the dose data points. Results : On the central point of treatment planing basis, the upward and downward skin dose measured by the MOSFET was the highest when the fluence was used. The skin dose of inner and outer was distinguished from the figure(5.7% ~ 10.3%) when the measurements were fulfilled by using TLD and MOSFET. The other side of breast dose was the lowest in the open beam, on the other hand, is highest in the Dose fluence plan. In the different kinds of treatment, the dose deviation of inner and outer was the highest, and so this was the same with the TLD and MOSFET measurement case. The outer deviation was highest in the TLD, and the Inner'was highest in the MOSFET. Conclusion : Skin dose in relation to the treatment plan was the highest in the planing using the fluence technique in general and it was supposed that the high dose had been caused by the movement of the MLC. There's some differences among the all the treatment planning, but the sites such as IM node occurring the lack of dose, scar, drain site are needed pay close attention. Using the treatment planning of dose fluence is good to compensate the lack of dose, but It increases the dose of the selective range rather than the overall dose. Therefore, choosing the radiotherapy technique is desirable in the lights of the age and performance of the patient.

  • PDF

A Study on Calibration Procedures for Ir-192 High Dose Rate Brachytherapy Sources (고선량률(HDR) 근접치료의 동위원소 Ir-192에 대한 측정방법에 관한 고찰)

  • Baek, Tae-Seong;Lee, Seung-Wook;Na, Soo-Kyong
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.19 no.1
    • /
    • pp.19-26
    • /
    • 2007
  • Purpose: To compare of the accuracy among various measurement procedures of HDR Brachytherapy, and to evaluate the clinical suitability and usefulness of alternative PMMA (polymethylmethacrylateplastics: $C_5H_8O_2$) plate phantom without any additional cost due to the purchase of measuring apparatus. Materials and Methods: We made a comparative study on three types of measuring systems: well type chamber, source calibration jig, and PMMA plate phantom. Farmer type chamber was used for source calibration jig method and PMMA plate phantom method. Measurement was done 5 times each in comparison with the measurement values from manufacturer. Measurement results from experiment were compared with that from the manufacturer which is offered with the source whenever a source is substituted by a new one and evaluate the accuracy of source activity. Results: As a consequence of Ir-192 source measurement using well type chamber, source calibration jig and PMMA plate phantom, RMS (Root Mean Square) values for the relative error are 0.6%, 1.57%, 2.1%, respectively, compared with the data from manufacturer. And the mean errors with standard deviation are given $-0.2{\pm}0.5%$, $0.97{\pm}1.23%$, $-0.89{\pm}1.87%$ respectively. Conclusion: From the results shown by the three types of measurement system (well type chamber, source calibration jig, and PMMA plate phantom), the measurement with well type chamber produced the best accuracy. It turns out that we can also use the alternative system of PMMA plate phantom clinically without purchasing any additional particular apparatus since the system does not exceed the recommendation of AAPM (American Association of Physicists in Medicine), which requires the error range of within ${\pm}5%$.

  • PDF

The Effect of Cyclic Load on Different Femoral Fixation Techniques in Anterior Cruciate Ligament Reconstruction (전방십자인대 재건시 이식건의 대퇴골측 고정에 대한 주기성인장부하의 효과)

  • Song Eun-Kyoo;Kim Jong Seok
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.2 no.1
    • /
    • pp.28-36
    • /
    • 2003
  • Purpose: To determine and to compare the effects of cyclic loading on the fixation strength of different femoral fixation methods in ACL reconstruction. Materials and Methods: Biomechanical test using an Instron(R) machine (Model No.5569. Mass, U.S.A) were carried out to compare the pull out strength of six different femoral fixation techniques after a cyclic loading in 72 Yorkshire pig knees. The graft-bone complex was cyclically loaded between 30N and 150N at 50 mm/min rate for 1000 cycles and maximal tensile testing was performed. A preload of 30N was applied to the graft along the axis of the tunnel 15 minutes. ANOVA and the Duncan multiple comparison test was used for the statistical analysis. Results: The mean maximum tensile strength of femoral fixation before and after the cyclic loading test were 1003.4$\pm$145N and 601.1$\pm$154N in hamstring-LA screw(R) group, 595.5$\pm$104N and 360.7$\pm$56N in hamstring-Bioscrew(R) group, 1431.7$\pm$135N and 710.7$\pm$114N in hamstring-Semifix(R) group, 603.6$\pm$54N and 459.1$\pm$46N in hamstring-Endobutton(R) fixation group, 1067.4$\pm$145 and 601.8$\pm$134N in the BPTB-Titanium interference screw group, and 987.1$\pm$168N and 588.7$\pm$124N in the BPTB-Bioscrew(R) group. And these data illustrated that cyclic loading reduces the maximum tensile strength by 40 $\%$, 39 $\%$, 50 $\%$, 24 $\%$, 44 $\%$, 40 $\%$ respectively. Conclusions: With the results of these experiments it should be emphasized that rehabilitation exercises after anterior cruciate ligament reconstruction should be executed with precaution as the repetitive flexion and extension of the knee would compromise the maximum tensile strength of the graft tendon.

  • PDF