Prediction of Isothermal and Reacting Flows in Widely-Spaced Coaxial Jet, Diffusion-Flame Combustor (큰 지름비를 가지는 동축제트 확산화염 연소기내의 등온 및 연소 유동장의 예측)

  • O, Gun-Seop;An, Guk-Yeong;Kim, Yong-Mo;Lee, Chang-Sik
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.20 no.7
    • /
    • pp.2386-2396
    • /
    • 1996
  • A numerical simulation has been performed for isothermal and reacting flows in an exisymmetric, bluff-body research combustor. The present formulation is based on the density-weighted averaged Navier-Stokes equations together with a k-epsilon. turbulence model and a modified eddy-breakup combustion model. The PISO algorithm is employed for solution of thel Navier-Stokes system. Comparison between measurements and predictions are made for a centerline axial velocities, location of stagnation points, strength of recirculation zone, and temperature profile. Even though the numerical simulation gives acceptable agreement with experimental data in many respects, the present model is defictient in predicting the recoveryt rate of a central near-wake region, the non-isotropic turbulence effects, and variation of turbulent Schmidt number. Several possible explanations for these discrepancies have been discussed.

Comparison of Image Uniformity Due to Position Shifting in COR on Myocardial SPECT (Myocardial SPECT시 COR에서 위치변화에 따른 Image Uniformity 비교)

  • Lim, Hyun-Jin;Kim, Joong-Hyun;Kim, Jae-Il;Lim, Jung-Jin;Kim, Jin-Eui;Kim, Hyun-Joo;Lee, Jae-Sung;Lee, Dong-Soo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.1
    • /
    • pp.70-75
    • /
    • 2012
  • Purpose: It is important to acquire accurate data because the SPECT scan affected by various physical factors. The aim of this study was to compare the uniformity when both centers were matched or mismatched differed from position of heart in COR. Materials and methods: The images were acquired with cylindrical uniform phantom (6.7 cm diameter, 9 cm length) and heart insert phantom using Cardio MD SPECT system (Philips, USA). The phantoms were positioned on COR as well as four different points which were 10 cm above, below, left and right side from the COR. The counts from the both edge of cylindrical uniform phantom and those from the both wall of heart insert phantom were compared by using vertical and horizontal line profile. In addition, the qualitative evaluation was performed with heart insert phantom images and volunteer test. Results: In heart insert phantom study, the differences of counts between COR and 10 cm above, below, left and right point of COR were 1.1, 4.1, 4.9, 2.2 and 0.9% using T-A curve for horizontal view. In case of vertical view of COR 3.9, 21.9, 3.5, 23.9, 14.0% were shown. In cylindrical phantom study, the differences of counts between COR and 10 cm above, below, left and right point of COR were 4.3, 0.3, 3.3, 2.6 and 0.7% using T-A curve for horizontal view. In case of vertical view of COR 2.7, 3.0, 1.0, 0.3, 3.4% were shown. For qualitative evaluation, the images at COR were the most uniform for both of heart insert phantom and volunteer test, whereas other four positions showed somewhat distorted images. Conclusion: It showed the most uniform images when COR is matched with the heart. Therefore, we can expect that distortion which increased or decreased of myocardial perfusion will be prevented by matching the heart and COR when positioning. Furthermore, the accuracy of diagnosis will be improved as well.

  • PDF

Comparison of the Ejection Fraction Between Gated Blood Pool, Gated Blood Pool SPECT and Echocardiography (게이트심장혈액풀스캔과 게이트심장혈액풀 SPECT로 측정한 심박출계수의 심초음파와의 비교 연구)

  • Jeong, Ji-Uk;Lee, Hyo-Yeong;Yun, Jong-Jun;Lee, Hwa-Jin;Lee, Moo-Seok;Song, Hyeon-Seok;Park, Se-Yun;Kim, Jae-Hwan
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.150-154
    • /
    • 2010
  • Purpose: Ejection fraction (EF) is one of the most important factors that evaluate heart function. Recently, according to echocardiography and myocardial perfusion SPECT, the number of gated blood pool scan (planar GBP) is declining. Measurement of left ventricular ejection fraction using gated blood pool SPECT (GBPS) is known as relatively correspond with echocardiography. We compared EF derived from plnar GBP, GBPS and echocadiography using modified simpson method to determine the accuracy. Materials and Methods: From January 2007 to June 2010, planar GBP and GBPS were performed on 34 patients who admitted to Pusan National University Hospital (men 23, women 11, mean age $52.6{\pm}27.2$). Each patient was injected with $^{99m}{TcO_4}^-$ of 20 mCi after pyrophosphate injection and then scanned using both planar GBP and GBPS techniques. For image analysis, we use ADAC Laboratories, Ver. 4.20 software. The result analyzed was processed by SPSS 17.0 Win statistic program and statistical method applied in data analysis is one-way anova, Tukey's post hoc test, pearson correlation test. Results: One-way anova test show no significant difference (planar GBP $56.3{\pm}13.9%$; GBPS $60.4{\pm}16.0%$; echocardiography $59.1{\pm}14.4%$, p=0.486, p>0.05). Tukey's post hoc test show no significant difference (planar GBP-echocardiography p=0.697; GBPS-echocardiography p=0.928; planar GBP-GBPS p=0.469, p>0.05). Values for EF obtained with planar GBP and GBPS correlated well with those obtained with echocardiography (planar-echocardiography r=0.697; GBPS-echocardiography r=0.928; planar GBP-GBPS r=0.469). Conclusion: The problems of accuracy and reproducibility for planar GBP still remain. But planar GBP is a safe and non-invasive method. In addition, planar GBP is useful to evaluate patient with low resolution echocardiography images. GBPS is not appicated clinically. but GBPS can be obtain various left ventricular functional parameters. planar GBP, GBPS and echocardiography show a good correlation between each other. Therefore, planar GBP and GBPS are useful for evaluating left ventricular ejection fraction.

  • PDF

Compositions and Contents of Thinner and Reliability of MSDS sold in Busan and Gyeongnam Province (부산,경남에서 판매되는 시너(Thinner)의 구성 성분 중 벤젠 등 일부 독성물질의 함량과 물질안전보건자료에 관한 연구)

  • Kim, Yu Young;Yang, Seung Hyuk;Lee, Jung Sil;Lee, Hyoung Sook;Jang, Kong Hwa;Jin, Koo Won;Lee, Yong Il;Joo, Woo Hong;Paik, Do-Hyeon;Kang, Dae-Ook;Moon, Ja-Young;Cho, Yong-Kweon;Park, Dong Uk;Yoon, Chung Sik;Ha, Kwon Chul
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.16 no.4
    • /
    • pp.314-323
    • /
    • 2006
  • This study was conducted to identify ingredients of thinners and to confirm reliability of material safety data sheets (MSDS) of thinners for public and workers' health. The 41 thinner products were collected from paint shops located in Busan and Gyeongnam province. The 12 thinner products among them were identified using product MSDS. GC-MSD was used to analyze 41 kinds of thinners qualitatively and quantitatively. The 12 products MSDS were compared with thinner's component through qualitative analysis to confirm MSDS. Chemical ingredients, such as Benzene, Toluene, and Xylene etc., of thinners were analysed in quantity. The 41 thinner products contained 17 disclosed specific, trade name, or generically described chemical solvent ingredients. These 17 ingredients came under 6 classes: alcohols, aromatic hydrocarbons, esters, glycol ethers, ketones, and mixtures. These 17 ingredients were important in the view of industrial hygiene and had occupational exposure limit in the ambient, such as toluene, xylene, acetone, nonane, EGEE, heptane, cumene, MIBK, indene, tri-methyl benzene, etc, were found in 41 kinds of thinners. Aromatic hydrocarbons were the most identified ingredient in thinners. Especially, the benzene, which induces leukemia, was found in 4 kinds of thinners. The content rates of benzene in thinners were 0.25~1.18%. The benzene in enamel thinner, which were 0.39~0.72%, was highest from chemical classification. The contents of toluene, which was found from 27 kinds of thinners, were 5.35~64.16%, which were highest in sobu thinner as 58.80%. Xylene was found from 22 kinds of thinners and contents of xylene were 4.61~72.42%. Acrylic thinner's contents of xylene were 12.06~51.05%, which was most high. It was found that contents of benzene were increased and frequency of detection was decreased through comparison with other study. The MSDS possession rate of paint shops was low as 29.27%. So it did not provide information with public or workers. Mean of agreement rate between MSDS and components of thinners through qualitative analysis was 42.01% and it has wide range from 8.3% to 75%. There are many deficiencies in MSDS about component of thinners. In some case of sample, expecially, despite containing benzene, information was not written it on MSDS.

A Kinematics Analysis of Uchi-mata(inner thigh reaping throw) by Kumi-kata types and Two different Opponent's Height in Judo[II] (유도 맞잡기 타입과 받기의 신장에 따른 허벅다리걸기의 Kinematic 분석[2])

  • Kwon, Moon-Seok;Kim, Eui-Hwan;Cho, Dong-Hee
    • Korean Journal of Applied Biomechanics
    • /
    • v.12 no.2
    • /
    • pp.143-157
    • /
    • 2002
  • This study was to analyze the kinematic variables when the subjects performing Uchi-mata(inner thigh reaping throw) by Kumi-kata types((How to grasp A or B?) and two different opponent's height in Judo. Kinematic variables were temporal, posture. Data analysis was collective comparison of two-way ANOVA, t-test by type A&B and two different opponent's height. There were significant difference of Kumi-kata types(p<.05) in the time elapsed on Kake phase(KP : throwing phase) and hip, knee, ankle-angle of the attacking foot in the 1st stage of KP and knee, ankle-angle of the attacking foot and hip, knee ankle-angle of the supporting foot in the 2nd stage of KP. There were significant difference of two opponent's(p<.05) in the time elapsed on KP and hip-angle of the supporting foot in 1st stage of KP. Therefore, the interaction effect(p<.05) were in the time elapsed on KP and hip-angle of the supporting foot in the 2nd stage of KP. So, It could be suggested that Judoka hold on the part-behind neck lapel(type A) at the sleeve with the other of Judogi jacked when opponent's height was short. Because the time elapsed on KP of type B was not so fast as type A(p<.05) during performed Uchi-mata, and also the bigger hip-angle of the supporting foot in the 2nd stage of KP grew, the faster the time elapsed on KP became.

Quality Assurance of Patients for Intensity Modulated Radiation Therapy (세기조절방사선치료(IMRT) 환자의 QA)

  • Yoon Sang Min;Yi Byong Yong;Choi Eun Kyung;Kim Jong Hoon;Ahn Seung Do;Lee Sang-Wook
    • Radiation Oncology Journal
    • /
    • v.20 no.1
    • /
    • pp.81-90
    • /
    • 2002
  • Purpose : To establish and verify the proper and the practical IMRT (Intensity--modulated radiation therapy) patient QA (Quality Assurance). Materials and Methods : An IMRT QA which consists of 3 steps and 16 items were designed and examined the validity of the program by applying to 9 patients, 12 IMRT cases of various sites. The three step OA program consists of RTP related QA, treatment information flow QA, and a treatment delivery QA procedure. The evaluation of organ constraints, the validity of the point dose, and the dose distribution are major issues in the RTP related QA procedure. The leaf sequence file generation, the evaluation of the MLC control file, the comparison of the dry run film, and the IMRT field simulate image were included in the treatment information flow procedure QA. The patient setup QA, the verification of the IMRT treatment fields to the patients, and the examination of the data in the Record & Verify system make up the treatment delivery QA procedure. Results : The point dose measurement results of 10 cases showed good agreement with the RTP calculation within $3\%$. One case showed more than a $3\%$ difference and the other case showed more than $5\%$, which was out side the tolerance level. We could not find any differences of more than 2 mm between the RTP leaf sequence and the dry run film. Film dosimetry and the dose distribution from the phantom plan showed the same tendency, but quantitative analysis was not possible because of the film dosimetry nature. No error had been found from the MLC control file and one mis-registration case was found before treatment. Conclusion : This study shows the usefulness and the necessity of the IMRT patient QA program. The whole procedure of this program should be peformed, especially by institutions that have just started to accumulate experience. But, the program is too complex and time consuming. Therefore, we propose practical and essential QA items for institutions in which the IMRT is performed as a routine procedure.

Relationship Between Vaginal Cytology and Reproductive Hormone During the Estrous Cycle in Korea Jin-do Bitches (진돗개에서 발정주기 동안 질세포상과 번식호르몬의 관계)

  • 손창호;김정훈;정경아;강현구;오기석;박인철;박상국;한호재
    • Journal of Veterinary Clinics
    • /
    • v.17 no.1
    • /
    • pp.225-233
    • /
    • 2000
  • The aim in this study was to obtain the basic data for estimation of optimal mating time and ovulation time by finding out the relationship between vaginal cytology and reproductive hormone profiles during the estrous cycle in 36 Korea Jin-do bitches. A characteristic features of vaginal cytology during the estorous cycle were the high proportion of superficial cell, anuclear cell and erythrocyte in proestrus, superficial cell, anuclear cell and erythroucyte in estrus, parabasal cell, small and large intermediate cell and leukocytes in diestrus, and parabasal cell and small intermediate cell in anestrus, respectively. Cornification index(CI) was the high proportion in proestrus and estrus, then it was decreaed in diestrus and anestrus. It indicated that the CI was significantly high proportion in proestrus and estrus in comparison with the other phases. Plasma progesterone concentration was below 1.0ng/ml at the first day of vulval bleeding in pregnant and non-pregnat bitches, and then it was increaed slowly. When Day 0 was timed from the day that plasma progesterone concentration was first increased above 4.0ng/ml, plasma progesterone concentrations at Day 0 in pregnant and non-pregnant above 4.0 ng/ml, plasma progesterone concentrations at Day 0 in pregnant and non-pregnant bitches were $5.2{\pm}0.3ng/ml and 5.7{\pm}0.5ng/ml$$46.5{\pm}3.3 ng/ml$ in pregnant bitches and at Day 20 with $39.8{\pm}0.1ng/ml$ in nonpregnant bitches. It indicated that plasma progesterone concentration was higher in pregnant bitches than in non-pregnant bitches. Hereafter plasma progesterone concentration was decreased steadily. At Day 63 which is parturition day, plasma progesterone concentration was decreased below 1.0ng/ml with $0.8{\pm}0.2ng/ml$ in pregnant bitches whereas in the non-pregnant bitches at Day 75 were decreased below 1.0ng/ml with 40.5{\pm}0.4ng/ml$. Plasma progesterone concentrations was maintained below 1.0ng/ml during anestrus in all of them. The plasma estradiol-17 $\beta$ concentration was increased above 1.0 pg/ml at the first day of vulval bleeding and it showed a peak Day-1 with 38.2 pg/ml. Thereafter it was sharply decreased after Day 0, which was the day that plasma progesterone concentration was first increase above 4.0ng/ml, and was maintained below basal levels. In relationship between CI and reproductive hormones, plasma estradiol-17 $\beta$concentration showed a peak at Day-3 and CI showed a peak at Day-1 which was the second day after plasma estradiol-17 $\beta$ peak, and plasma progesterone concentration was first increased above 4.0ng/ml at Day 0 which was the first day after CI peak. CI was first increased above 80% at Day-6 which was the third day before plasma estradio-17 $\beta$ peak and it was maintained above 80% between Days-6 and Day 3 during 10 days, and showed above 90% at Day-3 which was the day that plasma estradiol-17 $\beta$peak and was maintained above 90% between Day-3 and Day 3 during 7 days. In conclusion, ovulation in Koran Jin-do bitches occurred at the first day after CI peak, at the third day after plasma estradiol-17 $\beta$peak and the day when plasma progesterone concentration was first increased above 4.0 ng/ml. And it was estimated that the optimal mating time was the day when the CI was maintained above 90% and plasma progesterone concentration was between 3.0~8.0ng/ml. Therefore plasma progesterone concentration measurement was used for determination of an accurate ovulation time and the optimal mating time but also vaginal cytology, which is low-priced with equipment and is the simple examination method, was reliable method for estimating estrous cycle, optimal breeding time and ovulation time in Korea Jin-do bitches.

  • PDF

The Comparison of Clinical Outcomes of Off-Pump versus On-Pump Coronary Artery Bypass Grafting in High Risk Patients (고위험군 환자에서 시행한 On-Pump CABG와 Off-Pump CABG의 비교연구)

  • 윤영남;이교준;김치영;안지영;오영준;유경종
    • Journal of Chest Surgery
    • /
    • v.37 no.9
    • /
    • pp.749-754
    • /
    • 2004
  • Off-pump coronary artery bypass grafting (Off-Pump CABG) has been proven to have less morbidity and to facilitate early recovery. High-risk surgical patients may have benefitted by avoiding the adverse effects of the cardiopulmonary bypass. We compared the effectiveness of Off-Pump CABG with that of coronary artery bypass using cardiopulmonary bypass (On-Pump CABG) in high-risk patients. Material and Method: 682 patients (424 Off-Pump CABG and 258 On-Pump CABG) underwent isolated coronary artery bypass grafting between January 2001 and June 2003. Patients who were considered high risk were selected High risk is defined as the presence of one or more of nine adverse prognostic factors. Data were collected from 492 patients in Off-Pump CABG and 100 in On-Pump CABG for risk factors, extent of coronary disease, and in-hospital outcomes. Result: Off-Pump CABG group and On-Pump CABG group did not show differences in their preoperative risk factors. We used more arterial grafts in Off-Pump CABG group (p < 0.05). Postoperative results showed that operative mortality (0.5% in Off-Pump CABG versus 2.0% in On-Pump CABG), renal failure (2.6% in Off-Pump CABG versus 7.0% in On-Pump CABG), and perioperative myocardial infarction (1.5% in Off-Pump CABG versus 1.0% in On-Pump CABG) did not differ significantly. However, Off-Pump CABG had shorter mean operation time (p<0.05), lower mean CK-MB level (p <0.05), lower rate of usage of inotropics (p < 0.05), shorter mean ventilation time (p <0.05), lower perioperative stroke (0% versus 2.0%), and shorter length of stay (p < 0.05) than On-Pump CABG. On-Pump CABG had more distal grafts (p<0.05) than Off-Pump CABG. Although Off-Pump CABG and On-Pump CABG did not show statistical differences in mortality and morbidity was more frequent in CABG. Conclusion: Off-Pump CABG reduces morbidity and favors hospital outcomes. Therefore, Off-Pump CABG is safe, reasonable and may be a preferable operative strategy for high-risk patients.

The Effects of the Warm Ischemic Time, the Preserving Temperature and the Cryopreservation Solution on the Viability of Tracheas (온혈허혈시간과 냉동보존온도와 보존액 조성에 따른 기관의 생육성 비교)

  • Sa, Young-Jo;Park, Jae-Kil;Sim, Sung-Bo;Jin, Ung;Moon, Young-Kyu;Lee, Sun-Hee;Jo, Kuhn-Hyun
    • Journal of Chest Surgery
    • /
    • v.42 no.3
    • /
    • pp.283-291
    • /
    • 2009
  • Background: Tracheal reconstruction after extended tracheal resection still remains as a major surgical challenge because good clinical outcomes are usually correlated with limited tracheal resection. Recent investigations with a using cryopreserved trachea for the reconstruction of a trachea have been carried out to overcome this problem. In this study, we analyzed viability of tracheas, which is an important determining factor for the success of transplanting a cryopreserved trachea and the development of post-transplantation tracheal stenosis, according to three different experimental factors: 1) the warm-ischemic time, 2) the cryopreservation solution and 3) the preserving temperature, to determine a better cryopreservation protocol and a better composition of the cryopreservation solution. Material and Method: Rats tracheas were harvested for different warm-ischemic times (0 hr, 12 hrs, 24 hrs). The tracheas were treated with recombinant insulin growth factor-1 (IGF) and they were stored at three different temperatures $(4^{\circ}C,\;-80^{\circ}C,\;-196^{\circ}C)$ for two weeks. After two weeks, we thawed the stored trachea and isolated the cells of the tracheas with using type II collagenase. We cultured the cells for seven days and then we compared the cellular viability by the MTT reduction assay. Result: Though cryopreservation is required to preserve a trachea for a longer time period, the viability of the tracheas stored at $-80^{\circ}C$ and $-196^{\circ}C$ was significantly reduced compared to that of the tracheas stored at $4^{\circ}C$. The viability of the tracheas with warm-ischemic times of 12 hrs and 24 hrs was also reduced in comparison to the tracheas with a warm-ischemic time of 0 hrs. Our data showed that the warm ischemic time and the parameters of crypreservation negatively affect on trachea viability. However, a cryopresrvation solution containing IGF-1 improved the cellular viability better than the existing cryopreservation solution. For the warm ischemic time group of a 0 hr, the addition of IGF-1 improved the viability of trachea at all the preserving temperatures. Conclusion: These experiments demonstrate that the viability of cryopreserved trachea can improved by modifying the components of the crypreservation solution with the addition of IGF-1 and reducing the warm-ischemic time.

Monitoring North Korea Nuclear Tests: Comparison of 1st and 2nd Tests (북한 핵실험 모니터링 : 1, 2차 비교)

  • Chi, Heon-Cheol;Park, Jung-Ho;Kim, Geun-Young;Che, Il-Young;Sheen, Dong-Hoon;Shin, Jin-Soo;Cho, Chang-Soo;Lee, Hee-Il
    • Geophysics and Geophysical Exploration
    • /
    • v.13 no.3
    • /
    • pp.243-248
    • /
    • 2010
  • Two suspicious events, which were claimed as underground nuclear tests by North Korea, were detected in the northern Korean Peninsula on October 9, 2006 and May 25, 2009. The KIGAM and Korea-China Joint seismic stations are distributed uniformly along the boundaries between North Korea and adjacent countries. In this study, the data from broadband stations with the distance of 200 to 550 km from the test site are used to analyze and compare two nuclear tests of North Korea. By comparing the time differences of the Pn-wave arrival times of 1st and 2nd tests at multiple stations, the relative locations of two test sites could be calculated precisely. From the geometrical calculation with the velocity of Pn wave $V_{Pn}$ = 8 km/s, the 2nd test site is estimated to move in the WNW direction from 1st one with the distance of 2 km. Body wave magnitude, mb of the 2nd test, which was announced officially as the network average of 4.5, varies widely with the directional location of stations from 4.1 to 5.2. The magnitude obtained from Lg wave, $m_b$(Lg), shows less variation between 4.3 to 4.7 with the average of 4.6. The moving-window spectra of time traces of 1st and 2nd tests show very similar pattern with different scale level. In addition, the corner frequencies of P wave of 1st and 2nd tests at each station show no or negligible difference. This indicates the burial depths of two tests might be very similar. The relative yield amount of the 2nd test is estimated 8 times larger than that of the 1st from the weighted average of ground-velocity amplitude ratios.