• Title/Summary/Keyword: Data Comparison

Search Result 12,566, Processing Time 0.041 seconds

Numerical Modelling for the Dilation Flow of Gas in a Bentonite Buffer Material: DECOVALEX-2019 Task A (벤토나이트 완충재에서의 기체 팽창 흐름 수치 모델링: DECOVALEX-2019 Task A)

  • Lee, Jaewon;Lee, Changsoo;Kim, Geon Young
    • Tunnel and Underground Space
    • /
    • v.30 no.4
    • /
    • pp.382-393
    • /
    • 2020
  • The engineered barrier system of high-level radioactive waste disposal must maintain its performance in the long term, because it must play a role in slowing the rate of leakage to the surrounding rock mass even if a radionuclide leak occurs from the canister. In particular, it is very important to clarify gas dilation flow phenomenon clearly, that occurs only in a medium containing a large amount of clay material such as a bentonite buffer, which can affect the long-term performance of the bentonite buffer. Accordingly, DECOVALEX-2019 Task A was conducted to identify the hydraulic-mechanical mechanism for the dilation flow, and to develop and verify a new numerical analysis technique for quantitative evaluation of gas migration phenomena. In this study, based on the conventional two-phase flow and mechanical behavior with effective stresses in the porous medium, the hydraulic-mechanical model was developed considering the concept of damage to simulate the formation of micro-cracks and expansion of the medium and the corresponding change in the hydraulic properties. Model verification and validation were conducted through comparison with the results of 1D and 3D gas injection tests. As a result of the numerical analysis, it was possible to model the sudden increase in pore water pressure, stress, gas inflow and outflow rate due to the dilation flow induced by gas pressure, however, the influence of the hydraulic-mechanical interaction was underestimated. Nevertheless, this study can provide a preliminary model for the dilation flow and a basis for developing an advanced model. It is believed that it can be used not only for analyzing data from laboratory and field tests, but also for long-term performance evaluation of the high-level radioactive waste disposal system.

Clinical Characteristics of Bronchopulmonary Dysplasia by Type and Severity (기관지폐이형성증의 유형 및 중증도에 따른 임상적 특징)

  • Shim, Gyu-Hong;Lee, Hyun-Ju;Kim, Eun-Sun;Lee, Jin-A;Choi, Chang-Won;Kim, Ee-Kyung;Kim, Han-Suk;Kim, Beyong-Il;Choi, Jung-Hwan
    • Neonatal Medicine
    • /
    • v.17 no.1
    • /
    • pp.21-33
    • /
    • 2010
  • Purpose : The increased survival of preterm infants in the neonatal intensive care unit recently has resulted in an increased frequency of bronchopulmonary dysplasia (BPD), especially with atypical forms. However, there have been few studies compairing classic and atypical BPD. The aim of this study was to investigate the differences between these two types of BPD. Methods : Infants with a gestational age less than 32 weeks born at the Seoul National University Hospital and Bundang Seoul National University Hospital from May 2004 to April 2007 were included. The data were categorized in 2 groups, classic and atypical BPD. We determined the incidence of BPD, and compared perinatal factors and postnatal managements between two groups. Results : Among 260 study subjects, 141 (54.2%) infants had BPD. Classic BPD infants were 64 and atypical BPD infants were 77. Comparison of differences between 2 groups, classic BPD infants were associated with respiratory distress syndrome, patent ductus arteriosus, intrauterine growth restriction, more high-frequency ventilator (HFV) use, low 1 and 5 minute Apgar scores. Atypical BPD infants were associated with antenatal steroid use, maternal premature rupture of membrane and chorioamnionitis (CAM). In multivariate analysis, more HFV use was associated with classic BPD. Antenatal steroid use, clinical CAM and histological CAM were associated with atypical BPD. Conclusion : The results of this study showed that antenatal factors (antenatal steroid use, clinical CAM, histological CAM) were associated with atypical BPD and postnatal factors (HFV used more) were associated with classic BPD. Further studies are needed for prevention and treatment of BPD.

Comparison of I-131 Scintigraphy, T1-201 Scintigraphy, and Serum Thyroglobulin in the Postoperative Follow-Up of Differentiated Thyroid Cancer (분화된 갑상선암의 수술후 경과관찰에서 I-131 스캔, T1-201 스캔 및 혈청 갑상선 글로불린 농도의 비교)

  • Lee, Hyun-Kyung;Song, Jae-Soon;Shinn, Joon-Jae;You, Kye-Hwa;Cha, Wang-Ki;Kim, Eun-Sil;Kim, Chong-Soon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.31 no.3
    • /
    • pp.346-355
    • /
    • 1997
  • To evaluate the utility of I-131, T1-201 scintigraphy, and serum thyroglobulin(Tg) in the follow-up of differentiated thyroid cancer, we compared retrospectively the data from 33 patients who underwent total or subtotal thyroidectomy. I-131 scintigraphy was performed after optimal endogenous TSH stimulation ($TSH>50{\mu}U/ml$). Total 41 cases of I-131 and T1-201 scintigraphy pairs were examined. Concomitant serum thyroglobulin levels were measured for 41 pairs of scan. Tg-off levels(that measured after discontinuation of the thyroid hormone) higher than 40ng/m1 were considered positive, and Tg-on levels(that measured during the thyroid hormone replacement) higher than 5ng/ml were considered positive. The concordance rates between I-131 therapeutic scintigraphy and T1-201 scintigraphy was 48% in the 38 case of total scan pairs(59% in the 17 cases of postoperative preablation group, and 38% in the 21 cases of postoperative postablation group). Of 17 studies before the I-131 ablation therapy(preablation group), 7 showed positive I-131 therapeutic scintigraphy despite of negative T1-201 scintigraphy. Among patients with negative I-131 therapeutic scintigraphy, no patients had abnormal T1-201 uptake. However, of 21 studies which were done after radioiodine therapy(postablation group) 6 had abnormal uptake on T1-201 scintigraphy which were not seen on I-131 therapeutic scintigraphy, and Tg-off levels also elevated in this 4 of 6 cases. As a result, I-131 therapeutic scintigraphy showed highest positive rate at postoperative preablation follow-up study in differentiated thyroid cancer patients. T1-201 scintigraphy may be useful in postablation studies, and the use of the combined modalities(T1-201 and Tg levels) provides a higher diagnostic yield.

  • PDF

Normal Limits of Left Ventricular Volumes and Ejection Fraction Measured by Gated Myocardial Perfusion SPECT: Comparison of Tc-99m MIBI and Tl-201 (심근 게이트 SPECT로 측정한 좌심실 용적과 구혈률의 정상 값 확립: Tl-201과 Tc-99m MIBI 게이트 SPECT의 비교)

  • Hyun, In-Young;Seo, Jeong-Kee;Kwan, Jun;Park, Keum-Soo;Choe, Won-Sick;Lee, Woo-Hyung
    • The Korean Journal of Nuclear Medicine
    • /
    • v.37 no.3
    • /
    • pp.147-152
    • /
    • 2003
  • Purpose: We evaluated radioisotope and sex-specific differences of normal limits for left ventricle volumes (LWs) and ejection fraction (EF) using myocardial perfusion gated SPECT (g-SPECT). Materials and Methods: Rest Tl-201/post-stress Tc-99m MIBI g-SPECT measurements with acquisitions of 8-frame were evaluated for 70 patients (mean age $55{\pm}14.56%$ female) who either had < 10% pretest likelihood of CAD (n = 12) or had normal coronary angiography (EF > 50%) (n = 58). LVEF, LWs were automatically determined by quantitative gated SPECT using QGS program. Results: Similar results were obtained for mean LVEF between Tc-99m MIBI ($62%{\pm}7%$ and Tl-201 ($63%{\pm}8%$) g-SPECT measurements. In Contrast, Tl-201 g-SPECT had significantly lower LWs values ($EDV;\;74{\pm}23mL,\;ESV;\;28{\pm}14mL$) than Tc-99m MIBI g-SPECT ($EDV;\;82{\pm}25mL,\;ESV;\;32{\pm}15mL$) (p<0.05). Women had significantly lower EDV ($Tc-99m\;MIBI;\;71{\pm}18mL,\;Tl-201;\;65{\pm}17mL$), and ESV values ($Tc-99m\;MIBI;\;27{\pm}10mL,\;Tl-201;\;23{\pm}8mL$) compared with EDV ($Tc-99m\;MIBI;\;96{\pm}27mL,\;Tl-201;\;85{\pm}24mL$), and ESV Values ($Tc-99m\;MIBI;\;40{\pm}17mL,\;Tl-201;\;36{\pm}16mL$) of men (p<0.05). Women had significantly higher LV EF Values ($65%{\pm}7%$) than men ($60%{\pm}8%$) by Tl-201 gated SPECT (p<0.05). Conclusion: These data suggest significant differeuces in normal limits for LWs and EF, according to genders and radiopharmaceutical. Therefore, the evaluation of cardiac function in patients should consider radioisotope and sex-matched normal values.

Comparing Farming Methods in Pollutant runoff loads from Paddy Fields using the CREAMS-PADDY Model (영농방법에 따른 논에서의 배출부하량 모의)

  • Song, Jung-Hun;Kang, Moon-Seong;Song, In-Hong;Jang, Jeong-Ryeol
    • Korean Journal of Environmental Agriculture
    • /
    • v.31 no.4
    • /
    • pp.318-327
    • /
    • 2012
  • BACKGROUND: For Non-Point Source(NPS) loads reduction, pollutant loads need to be quantified for major farming methods. The objective of this study was to evaluate impacts of farming methods on NPS pollutant loads from a paddy rice field during the growing season. METHODS AND RESULTS: The height of drainage outlet, amount of fertilizer, irrigation water quality were considered as farming factors for scenarios development. The control was derived from conventional farming methods and four different scenarios were developed based combination of farming factors. A field scale model, CREAMS-PADDY(Chemicals, Runoff, and Erosion from Agricultural Management Systems for PADDY), was used to calculate pollutant nutrient loads. The data collected from an experimental plot located downstream of the Idong reservoir were used for model calibration and validation. The simulation results agreed well with observed values during the calibration and validation periods. The calibrated model was used to evaluate farming scenarios in terms of NPS loads. Pollutant loads for T-N, T-P were reduced by 5~62%, 8~37% with increasing the height of drainage outlet from 100 mm of 100 mm, respectively. When amount of fertilizer was changed from standard to conventional, T-N, T-P pollutant loads were reduced by 0~22%, 0~24%. Irrigation water quality below water criteria IV of reservoir increased T-N of 9~65%, T-P of 9~47% in comparison with conventional. CONCLUSION(S): The results indicated that applying increased the height of drainage after midsummer drainage, standard fertilization level during non-rainy seasons, irrigation water quality below water criteria IV of reservoir were effective farming methods to reduce NPS pollutant loads from paddy in Korea.

The Comparison between High Dose and Low Dose Morphine in Terminal Cancer Patients During the Last 1 Week to Death (고용량과 저용량의 몰핀을 쓰는 말기 암 환자에서 임종 1주일동안 비교)

  • Cho, Doo-Yeoun;Cha, Kyu-Jin;Yoon, Bang-Boo;Yeom, Chang-Hwan
    • Journal of Hospice and Palliative Care
    • /
    • v.5 no.1
    • /
    • pp.24-30
    • /
    • 2002
  • Background : Pain is one of the most feared consequences of cancer. $65{\sim}85%$ of cancer patients experienced severe pain, and sometimes high dose morphine is used to these patients. But many doctors still have 'opioid-phobia' and hesitate to use high dose morphine. We investigated the morphine therapy in terminal cancer patients during the last 1 week to death, and found any differences according to the morphine dosage. Methods : 93 patients admitted to National Health Insurance Corporation Ilsan Hospital, department of family medicine for hospice care between September 2000 and the end of October 2001 and lived more than 1 week entered in the study. We investigated the demographic data, laboratory tests and sufficient dosage of morphine for pain control. According to the calculated dosage by OME(oral morphine equivalent), patients were divided into low dosage group (${\leq}150mg/day$) and high dosage group (>150 mg/day). The chi-squared test were used to evaluate the influence of age, gender, tumor sites, metastasis and adverse effects of morphine. Results : Mean age was $65.0{\pm}13.1year$ in low dosage group and $59.9{\pm}11.6year$ in high dosage group. 32 men (50.0%) and 32 women (50.0%) were included in low dosage group and 15 men (51.7%) and 14 women (48.3%) in high dosage group. Stomach was the most frequent tumor site and lung was the next. Metastasis were found 58 (90.6%) in low dosage group and 28 (96.6%) in high dosage group. In other palliative radiotherapy and adverse effects, there were no differences in both group. Conclusion : During the last 1 week to death in cancer patients, there were no difference according to the morphine dosage. So we don't have to have 'opioid-phobia' in treating the terminal cancer patients.

  • PDF

Interannual and Seasonal Variations of Water Quality in Terms of Size Dimension on Multi-Purpose Korean Dam Reservoirs Along with the Characteristics of Longitudinal Gradients (우리나라 다목적댐 인공호들의 규모에 따른 연별.계절별 수질변이 및 상.하류간 종적구배 특성)

  • Han, Jeong-Ho;Lee, Ji-Yeoun;An, Kwang-Guk
    • Korean Journal of Ecology and Environment
    • /
    • v.43 no.2
    • /
    • pp.319-337
    • /
    • 2010
  • Major objective of this study was to determine interannual and seasonal water quality along with characteristics of longitudinal gradients along the reservoir axis of the riverine zone (Rz)-to-lacustrine zone (Lz). Water quality dataset of five years during 2003~2007 used here were obtained from Ministry of Environment, Korea and ten physical, chemical and biological parameters were analyzed in the study. Similarity analysis, based on moropho-hydrological variables of reservoir surface area, watershed area, total inflow, and outflow, showed that the reservoirs were categorized as three groups of large-dam reservoirs (Chungju Reservoir, Daecheong Reservoir and Soyang Reservoir), mid-size reservoirs (Andong Reservoir, Yongdam Reservoir, Juam Reservoir and Hapcheon Reservoir), and small-size reservoirs (Hoengseong Reservoir and Buan Reservoir). According to the data comparison of high-flow year (2003) vs. lowflow year (2005), dissolved oxygen (DO), pH, biological oxygen demand (BOD), suspended solids (SS), total nitrogen (TN), total phosphorus (TP), chlorophyll-a (CHL) and electrical conductivity (EC) declined along the longitudinal axis of Rz to Lz and water transparency, based on Secchi depth (SD), increased along the axis. These results indicate that transparency was a function of Values of pH, DO, SS, SD, and EC at each site were greater in the low-flow year (2005) than the high-flow year (2003), whereas values of BOD, COD, TN, TP and CHL were greater in the high-flow year (2003). When values of TN, TP, CHL and SD in nine reservoirs were compared in the three zones of Rz, Tz, and Lz, values of TN, TP and CHL declined along longitudinal gradients and SD showed the opposite due to the sedimentation processes from the water column. Values of TN were not statistically correlated with TP values. The empirical linear models of TP-CHL and CHL-SD showed significant (p<0.05, $R^2$>0.04). In the mid-size reservoirs, the variation of CHL was explained ($R^2$=0.2401, p<0.0001, n=239) by the variation of TP. The affinities in the correlation analysis of mid-size reservoirs were greater in the CHL-SD model than any other empirical models, and the CHL-SD model had an inverse relations. In the meantime, water quality variations was evidently greater in Daecheong Reservoir than two reservoirs of Andong Reservoir and Hoengseong Reservoir as a result of large differences of water quality by long distance among Rz, Tz and Lz.

Comparison of Taste Compounds of Red Sea Bream, Rockfish and Flounders Differing in the Localities and Growing Conditions (산지 및 성장조건별 참돔, 조피볼락, 넙치의 정미성분에 대한 연구)

  • Kim, Hee-Yun;Shin, Jae-Wook;Park, Hee-Ok;Choi, Sung-Hee;Jang, Young-Mi;Lee, Soo-Oh
    • Korean Journal of Food Science and Technology
    • /
    • v.32 no.3
    • /
    • pp.550-563
    • /
    • 2000
  • This study was carried out in order to elucidate the fundamental data on the taste compounds between wild and cultured fishes produced on Chungmu and Wando at the southern coast areas of Korea. For this purpose, the food components of cultured fishes such as red sea bream Pagnus major, Sebastes pachycephalus and flounder, Paralichthys olivaceus being spot lighted for the main sea fish, the staple food and high economic fish were investigated and compared with those of the wild ones. There was a little appreciable difference in the proximate compositions of all the species from localities between wild and cultured fishes. But according to the growing conditions, wild fishes were higher in moisture contents and lower in crude lipid content than those of cultured fishes and little difference was seen in protein and ash contents between the two. With regard to the nucleotides and their related compounds, i.e. ADP, IMP and inosine were detected but ATP and hypoxanathine were not from them. On the other hand, there were little difference in the total taste compounds of all the species from localities and the growing conditions between wild and cultured fishes. But all the species were higher in IMP content. The total of seventeen amino acids were detected in samples. The highly contents of glutamic acid, lysine, aspartic acid, proline, leucine, alanine, valine and alginine were showed and less low contents of cystein, histidine, methionine, tyrosine and phenylalanine were detected. The total amino acids of the others were much alike in that composition. Little difference was seen from localities and the growing conditions between wild and cultured ones. The free amino acids were much alike in that composition of all the species. There was little difference in the free amino acid compositions all the species from localities and the growing conditions between wild and cultured fishes. But taurine was dominant, showing from 39% to 65% of the free amino acid content and it is followed by hydroxyproline, lysine, alanine and glycine in other. There were differences in the organic acid compositions of all the species from localities and the growing conditions between wild and cultured fishes. In addition, cultured fishes were more abundant in the total organic acid compositions than those of wild ones.

  • PDF

Comparison on accuracy of porcelain color reproducibility using two colorimeters (2종의 측색기에 의한 도재 색조 재현의 정확성 비교)

  • Lee, Tai-Il;Ahn, Jin-Soo;Kim, Young-Soo;Shin, Sang-Wan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.3
    • /
    • pp.348-355
    • /
    • 2009
  • Statement of problem: Although the use of colorimeter to improve the accuracy of tooth color measurement has increased, it is real situation that there is almost no comparative study about the accuracy among various colorimeters. Purpose: The purpose of this study is to compare the accuracy of porcelain color reproducibility using ShadeEye-Ncc dental chroma meter (Shofu Inc., Kyoto, Japan) and Shadepilot$^{TM}$ system (Degudent Inc., Hanau, Germany). Material and methods: Color of 2M2 and 3M2 shade tap of Vitapan 3D Master shade guide were measured using the above two colorimeters. Porcelain specimens were fabricated through this data. The porcelain systems used were Vintage Halo Porcelain system with ShadeEye-Ncc dental chroma meter, and VitaOmega900 Porcelain system with Shadepilot$^{TM}$ system. Colors of shade tap models and porcelain specimen were measured with spectrophotometer, and calculated delta E based on the results. Results: The following results were obtained. 1. Shadepilot$^{TM}$ system showed more suitable porcelain color reproducibility compared to ShadeEye-Ncc dental chroma meter (P <.05). 2. The result showed the difference of porcelain color reproducibility according to shade of Shade tap which is model. More suitable porcelain color reproducibility was shown at 3M2 shade tap than at 2M2 shade tap (P <.05). 3. The average of ${\Delta}E*$ of porcelain specimens which was made by the two colorimeters was 4.44-6.14, so the difference of shade was shown through the naked eye. Conclusion: Shadepilot$^{TM}$ system showed more suitable porcelain color reproducibility. When using ShadeEye-Ncc dental chromameter, it will be necessary to improve accuracy through coloring various parts of the whole tooth.

Shear bond strength of Universal bonding systems to Ni-Cr alloy (니켈-크롬 합금에 대한 다용도 접착 시스템의 전단결합강도)

  • Song, So-Yeon;Son, Byung-Wha;Kim, Jong-Yeob;Shin, Sang-Wan;Lee, Jeong-Yol
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.53 no.4
    • /
    • pp.295-300
    • /
    • 2015
  • Purpose: The aim of this study was to evaluate the shear bond strength between Ni-Cr alloy and composite resin using universal adhesive systems coMPared to conventional method using metal primers. Materials and methods: For this study, a total of 120 cast commercial Ni-Cr alloy (Vera Bond 2V) disks were embedded in acrylic resin, and their surfaces were smoothed with silicon carbide papers and airborne-particle abrasion. Specimens of each metal were divided into 6 groups based on the combination of metal primers (Metal primer II, Alloy primer, Metal & Zirconia primer, MKZ primer) and universal adhesive systems (Single Bond Universal, All Bond Universal). All specimens were stored in distilled water at $37^{\circ}C$ for 24 hours. Shear bond strength testing was performed with a universal testing machine at a cross head speed of 1 m/min. Data (MPa) were analyzed using one-way ANOVA and the post hoc Tukey's multiple comparison test (${\alpha}$=.05). Results: There were significant differences between Single Bond Universal, All Bond Universal, Metal Primer II and Alloy Primer, MKZ Primer, Metal & Zirconia Primer (P<.001). Conclusion: Universal Adhesive system groups indicated high shear bond strength value bonded to Ni-Cr alloy than that of conventional system groups using primers except Metal Primer II. Within the limitations of this study, improvement of universal adhesive systems which can be applied to all types of restorations is recommended especially non-precious metal alloy. More research is needed to evaluate the effect of silane inclusion or exclusion in universal adhesive systems.