• Title/Summary/Keyword: Data Acquisition Equipment

Search Result 199, Processing Time 0.03 seconds

Evaluation of Structural Integrity of Aircraft External Fuel Tank for Separation Loads (분리하중에 대한 항공기용 외부연료탱크 구조 건전성 평가)

  • Hyun-gi Kim;Sungchan Kim;Min-su Park;Su-hong An
    • Journal of Aerospace System Engineering
    • /
    • v.18 no.1
    • /
    • pp.64-71
    • /
    • 2024
  • The external fuel tank of an aircraft is a main component that can increase the cruising range of the aircraft. It must be able to be stably separated from the pylon in an emergency situation. At this time, a separation load is applied to the fin and the pivot of the external fuel tank. To stably separate the external fuel tank, the structural soundness of the fin and the pivot must be confirmed. In this study, structural tests were conducted to verify the structural integrity of the external fuel tank pin and pivot when the external fuel tank was separated from the aircraft. Results are then presented. In this paper, a test configuration diagram consisting of the hydraulic and load control equipment, data acquisition system, and pneumatic supply unit used in the structural test was explained. Test installation and test load application plan for each test condition were provided. As results of the structural test, it was found that test load and internal pressure of the test specimen were properly controlled within the allowable range in each test. It was confirmed that serious structural defects in the test specimen did not occur under required load conditions. In conclusion, through structural test for design limit load and design ultimate load, it was proven that the fin and pivot of the external fuel tank for aircraft covered in this study had sufficient structural strength.

A Study on the Creep Deformation Characteristic of AZ31 Mg Alloy at High Temperature (AZ3l 마그네슘 합금의 고온 크리이프 변형특성에 관한 연구)

  • An Jungo;Kang Daemi;Koo Yang;Sim Sungbo
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.13 no.3
    • /
    • pp.186-192
    • /
    • 2005
  • The apparent activation energy Qc, the applied stress exponent n, and rupture life have been determined from creep test results of AZ31 Mg alloy over the temperature range of 200$^{\circ}C$ to 300$^{\circ}C$ and the stress range of 23.42 MPa to 93.59 MPa, respectively, in order to investigate the creep behavior. Constant load creep tests were carried out in the equipment including automatic temperature controller with data acquisition computer. At the temperature of $200^{\circ}C{\sim}220^{\circ}C$ and under the stress level of 62.43~93.59 MPa, and at around the temperature of $280^{\circ}C{\sim}300^{\circ}C$ and under the stress level of 23.42~39.00 MPa, the creep behavior obeyed a simple power-law relating steady state creep rate to applied stress and the activation energy fur the creep deformation was nearly equal to that of the self diffusion of Mg alloy including aluminum From the above results, at the temperature of $200^{\circ}C{\sim}220^{\circ}C$ the creep deformation for AZ31 Mg alloy seemed to be controlled by dislocation climb but controlled by dislocation glide at $280^{\circ}C{\sim}300^{\circ}C$ .And relationship beween rupture time and stress at around the temperature of $200^{\circ}C{\sim}220^{\circ}C$ and under the stress level of 62.43~93.59 MPa, and again at around the temperature of $280^{\circ}C{\sim}300^{\circ}C$ and under the stress level of 23.42~39.00 MPa, respectively, appeard as fullow; log$\sigma$=-0.18(T+460)(logtr+21)+5.92, log$\sigma$ = -0.25(T+460)(logtr+21)+8.02 Also relationship beween rupture time and steady state creep rate appears as follow; ln$\dot$ =-0.881ntr-2.45

Remote Access and Data Acquisition System for High Voltage Electron Microscopy (초고전압 투과전자현미경의 원격제어 및 데이터 획득 시스템)

  • Ahn, Young-Heon;Kang, Ji-Seoun;Jung, Hyun-Joon;Kim, Hyeong-Seog;Jung, Hyung-Soo;Han, Hyuck;Jeong, Jong-Man;Gu, Jung-Eok;Lee, Sang-Dong;Lee, Jy-Soo;Cho, Kum-Won;Kim, Youn-Joong;Yeom, Heon-Young
    • Applied Microscopy
    • /
    • v.36 no.1
    • /
    • pp.7-16
    • /
    • 2006
  • A new remote access system for a 1.3 MV high voltage electron microscope has been developed. Almost all essential functions for HVEM operation, huck as stage control, specimen tilting, TV camera selection and image recording, are successfully embedded into this prototype of the remote system. Particularly, this system permits perfect and precise operation of the goniometer and also controls the high resolution digital camera via simple Web browsers. Transmission of control signals and communication with the microscope is accomplished via the global ring network for advanced applications development (GLORIAD). This fact makes it possible to realize virtual laboratory to carry out practical national and international HVEM collaboration by using the present system

Characterization of Deep Learning-Based and Hybrid Iterative Reconstruction for Image Quality Optimization at Computer Tomography Angiography (전산화단층촬영조영술에서 화질 최적화를 위한 딥러닝 기반 및 하이브리드 반복 재구성의 특성분석)

  • Pil-Hyun, Jeon;Chang-Lae, Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.1
    • /
    • pp.1-9
    • /
    • 2023
  • For optimal image quality of computer tomography angiography (CTA), different iodine concentrations and scan parameters were applied to quantitatively evaluate the image quality characteristics of filtered back projection (FBP), hybrid-iterative reconstruction (hybrid-IR), and deep learning reconstruction (DLR). A 320-row-detector CT scanner scanned a phantom with various iodine concentrations (1.2, 2.9, 4.9, 6.9, 10.4, 14.3, 18.4, and 25.9 mg/mL) located at the edge of a cylindrical water phantom with a diameter of 19 cm. Data obtained using each reconstruction technique was analyzed through noise, coefficient of variation (COV), and root mean square error (RMSE). As the iodine concentration increased, the CT number value increased, but the noise change did not show any special characteristics. COV decreased with increasing iodine concentration for FBP, adaptive iterative dose reduction (AIDR) 3D, and advanced intelligent clear-IQ engine (AiCE) at various tube voltages and tube currents. In addition, when the iodine concentration was low, there was a slight difference in COV between the reconstitution techniques, but there was little difference as the iodine concentration increased. AiCE showed the characteristic that RMSE decreased as the iodine concentration increased but rather increased after a specific concentration (4.9 mg/mL). Therefore, the user will have to consider the characteristics of scan parameters such as tube current and tube voltage as well as iodine concentration according to the reconstruction technique for optimal CTA image acquisition.

Use of Digital Educational Resources in the Training of Future Specialists in the EU Countries

  • Plakhotnik, Olga;Zlatnikov, Valentyn;Matviienko, Olena;Bezliudnyi, Oleksandr;Havrylenko, Anna;Yashchuk, Olena;Andrusyk, Pavlo
    • International Journal of Computer Science & Network Security
    • /
    • v.22 no.10
    • /
    • pp.17-24
    • /
    • 2022
  • The article proves that the main goal of informatization of higher education institutions in the EU countries is to improve the quality of education of future specialists by introducing digital educational resources into the education process. The main tasks of informatization of education are defined. Digital educational resources are interpreted as a set of data in digital form that is applicable for use in the learning process; it is an information source containing graphic, text, digital, speech, music, video, photo and other information aimed at implementing the goals and objectives of modern education; educational resources on the Internet, electronic textbooks, educational programs, electronic libraries, etc. The creation of digital educational resources is defined as one of the main directions of informatization of all forms and levels of Education. Types of digital educational resources by educational functions are considered. The factors that determine the effectiveness of using digital educational resources in the educational process are identified. The use of digital educational resources in the training of future specialists in the EU countries is considered in detail. European countries note that digital educational resources in professional use allow you to implement a fundamentally new approach to teaching and education, which is based on broad communication, free exchange of opinions, ideas, information of participants in a joint project, on a completely natural desire to learn new things, expand their horizons; is based on real research methods (scientific or creative laboratories), allowing you to learn the laws of nature, the basics of techniques, technology, social phenomena in their dynamics, in the process of solving vital problems, features of various types of creativity in the process of joint activities of a group of participants; promotes the acquisition by teachers of various related skills that can be very useful in their professional activities, including the skills of using computer equipment and various digital technologies.

A Study on Design of Agent based Nursing Records System in Attending System (에이전트기반 개방병원 간호기록시스템 설계에 관한 연구)

  • Kim, Kyoung-Hwan
    • Journal of Intelligence and Information Systems
    • /
    • v.16 no.2
    • /
    • pp.73-94
    • /
    • 2010
  • The attending system is a medical system that allows doctors in clinics to use the extra equipment in hospitals-beds, laboratory, operating room, etc-for their patient's care under a contract between the doctors and hospitals. Therefore, the system is very beneficial in terms of the efficiency of the usage of medical resources. However, it is necessary to develop a strong support system to strengthen its weaknesses and supplement its merits. If doctors use hospital beds under the attending system of hospitals, they would be able to check a patient's condition often and provide them with nursing care services. However, the current attending system lacks delivery and assistance support. Thus, for the successful performance of the attending system, a networking system should be developed to facilitate communication between the doctors and nurses. In particular, the nursing records in the attending system could help doctors monitor the patient's condition and provision of nursing care services. A nursing record is the formal documentation associated with nursing care. It is merely a data repository that helps nurses to track their activities; nursing records thus represent a resource of primary information that can be reused. In order to maximize their usefulness, nursing records have been introduced as part of computerized patient records. However, nursing records are internal data that are not disclosed by hospitals. Moreover, the lack of standardization of the record list makes it difficult to share nursing records. Under the attending system, nurses would want to minimize the amount of effort they have to put in for the maintenance of additional records. Hence, they would try to maintain the current level of nursing records in the form of record lists and record attributes, while doctors would require more detailed and real-time information about their patients in order to monitor their condition. Therefore, this study developed a system for assisting in the maintenance and sharing of the nursing records under the attending system. In contrast to previous research on the functionality of computer-based nursing records, we have emphasized the practical usefulness of nursing records from the viewpoint of the actual implementation of the attending system. We suggested that nurses could design a nursing record dictionary for their convenience, and that doctors and nurses could confirm the definitions that they looked up in the dictionary through negotiations with intelligent agents. Such an agent-based system could facilitate networking among medical institutes. Multi-agent systems are a widely accepted paradigm for the distribution and sharing of computation workloads in the scientific community. Agent-based systems have been developed with differences in functional cooperation, coordination, and negotiation. To increase such communication, a framework for a multi-agent based system is proposed in this study. The agent-based approach is useful for developing a system that promotes trade-offs between transactions involving multiple attributes. A brief summary of our contributions follows. First, we propose an efficient and accurate utility representation and acquisition mechanism based on a preference scale while minimizing user interactions with the agent. Trade-offs between various transaction attributes can also be easily computed. Second, by providing a multi-attribute negotiation framework based on the attribute utility evaluation mechanism, we allow both the doctors in charge and nurses to negotiate over various transaction attributes in the nursing record lists that are defined by the latter. Third, we have designed the architecture of the nursing record management server and a system of agents that provides support to the doctors and nurses with regard to the framework and mechanisms proposed above. A formal protocol has also been developed to create and control the communication required for negotiations. We verified the realization of the system by developing a web-based prototype. The system was implemented using ASP and IIS5.1.

Development of Supplemental Equipment to Reduce Movement During Fusion Image Acquisition (융합영상(Fusion image)에서 움직임을 줄이기 위한 보정기구의 개발)

  • Cho, Yong Gwi;Pyo, Sung Jae;Kim, Bong Su;Shin, Chae Ho;Cho, Jin Woo;Kim, Chang Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.17 no.2
    • /
    • pp.84-89
    • /
    • 2013
  • Purpose: Patients' movement during long image acquisition time for the fusion image of PET-CT (Positron Emission Tomography-Computed Tomography) results in unconformity, and greatly affects the quality of the image and diagnosis. The arm support fixtures provided by medical device companies are not manufactured considering the convenience and safety of the patients; the arm and head movements (horizontal and vertical) during PET/CT scan cause defects in the brain fundus images and often require retaking. Therefore, this study aims to develop patient-compensation device that would minimize the head and arm movements during PET/CT scan, providing comfort and safety, and to reduce retaking. Materials and Methods: From June to July 2012, 20 patients who had no movement-related problems and another 20 patients who had difficulties in raising arms due to shoulder pain were recruited among the ones who visited nuclear medicine department for PET Torso scan. By using Patient Holding System (PHS), different range of motion (ROM) in the arm ($25^{\circ}$, $27^{\circ}$, $29^{\circ}$, $31^{\circ}$, $33^{\circ}$, $35^{\circ}$) was applied to find the most comfortable angle and posture. The manufacturing company was investigated for the permeability of the support material, and the comfort level of applying bands (velcro type) to fix the patient's head and arms was evaluated. To find out the retake frequency due to movements, the amount of retake cases pre/post patient-compensation were analyzed using the PET Torso scan data collected between January to December 2012. Results: Among the patients without movement disorder, 18 answered that PHS and $29^{\circ}$ arm ROM were the most comfortable, and 2 answered $27^{\circ}$ and $31^{\circ}$, respectively. Among the patients with shoulder pain, 15 picked $31^{\circ}$ as the most comfortable angle, 2 picked $33^{\circ}$, and 3 picked $35^{\circ}$. For this study, the handle was manufactured to be adjustable for vertical movements. The material permeability of the patient-compensation device has been verified, and PHS and the compensation device were band-fixed (velcro type) to prevent device movements. A furrow was cut for head fixation to minimize the head and neck movements, fixing bands were attached for the head, wrist, forearm, and upper arm to limit movements. The retake frequency of PET Torso scan due to patient movements was 11.06% (191 cases/1,808 patients) before using the movement control device, and 2.65% (48 cases/1,732 patients) after using the device; 8.41% of the frequency was reduced. Conclusion: Recent change and innovation in the medical environment are making expensive medical image scans, and providing differentiated services for the customers is essential. To secure patient comfort and safety during PET/CT scans, ergonomic patient-compensation devices need to be provided. Therefore, this study manufactured a patientcompensation device with vertically adjustable ergonomic ROM according to the patient's body shape and condition during PET Torso scan. The defects in the basal ganglia images due to arm movements were reduced, and retaking was decreased.

  • PDF

Evaluation of Image Quality using SE-EPI and SSH-TSE Techniques in MRDWI (자기공명확산강조영상에서 SE-EPI 와 SSH-TSE 기법을 이용한 영상의 질 평가)

  • Goo, Eun-Hoe
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.7
    • /
    • pp.991-998
    • /
    • 2021
  • The purpose of this study is to investigate the image quality of the SE-EPI and SSH-TSE technique for MR DWI. Datum were analyzed for 35 PACS transmission datum(Normal part: 12 males, 13 females, Cerebral Infarction: 10(5males and 5females), and average age 68±7.32), randomly selected patients who underwent MRDWI tests. The equipment used was Ingenia CX 3.0T, SSH_TSE and SE-EPI pulse sequence and 32 Ch. head coil were used for data acquisition. Image evaluation was performed on the paired t-test and Wilcoxon tests, and was considered significant when the p value was 0.05 or less. As a result of quantitative analysis of SNR for DWI images, the mean and standard deviation values of 4 parts (WM, GM, BG, Cerebellum) in ADC (s/mm2), Diffusion b=0, 1000 images were higher in SE-EPI techniques(ADC: 120.50 ± 40, b=0: 54.50 ± 35.91, b=1000: 91.61 ± 36.63) than in SSH-TSE techniques(ADC: 99.69 ± 31.10, b=0: 43.52 ± 25.00 , b=1000: 60.74 ± 24.85)(p<0.05). The CNR values for GM-WM, BG-WM sites were also higher in SE-EPI technique (ADC: 116.08 ± 43.30, b=0:27.23 ± 09.10, b=1000: 78.50 ± 16.56) than in SSH-TSE(ADC: 101.08 ± 36.81, b=0: 23.96 ± 07.79 , b=1000: 74.30 ± 14.22). As a visual evaluation of observers, ghost artifact, magnetic susceptibility artifacts and overall image quality for SE-TSE and SSH-TSE all yielded high results from SSH-TSE techniques(ADC:3.6 ± 0.1, 2.8 ± 0.2, b=0: 4.3 ± 0.3, 3.4 ± 0.1 b=1000: 4.3 ± 0.2, 3.5 ± 0.2, p=0.000). In conclusion, the SE-EPI technique obtained an superiority in SNR and CNR measurements using SSH-TSE, SE-EPI. In the qualitative analysis, the SSH-TSE pulse sequence was obtained a high result according to the pulse sequence characteristics.

The Consideration of the Region of Interest on $^{99m}Tc$-DMSA Renal Scan in Pediatric Hydronephrosis Patients (수신증을 진단 받은 소아 환자의 DMSA 신장 검사에서 정확한 관심영역 설정에 대한 고찰)

  • NamKoong, Hyuk;Lee, Dong-Hyuk;Oh, Shin-Hyun;Cho, Seok-Won;Park, Hoon-Hee;Kim, Jung-Yul;Kim, Jae-Sam;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.1
    • /
    • pp.27-33
    • /
    • 2012
  • Purpose: Most of diagnosis in the pediatric hydronephrosis patients have been performed $^{99m}Tc$-DMSA renal scan. Then the region of interest (ROI) is set for comparative analysis of uptake ratio in left-right kidney after acquiring the image. But if the equipment set an automatic ROI, the ROI could include expanded renal pelvis due to hydronephrosis and the uptake ratio of left-right kidney will be incorrect result. Therefore this study compared both ROIs including expanded renal pelvis and excluding renal pelvis through experiment using normal kidney phantom and expanded renal pelvis phantom and suggested setting method of improved ROI. In addition, this study have been helped by readout doctor for investigate distinction radiopharmaceutical uptake between renal cortex and remained urine by expanded renal pelvis. Materials and Methods: The both of renal phantoms were filled with water and shacked with $^{99m}TcO_4$ 111 MBq. In order to describe the expanded renal pelvis, the five latex balloon were all filled with 10 mL water and each of balloon was mixed with $^{99m}TcO_4$ 18.5, 37, 55.5, 74, 92.5 MBq. And we made phantom with fixed $^{99m}TcO_4$activity of 37 MBq and mixed water 5, 10, 15, 20, 25 mL in each balloon. The left kidney was fixed its shape and the right kidney was modified like as hydronephrosis kidney by attached the latex balloons. And the acquiring counts were 2 million. After acquisition, we compared the image of ROI with Expanded renal pelvis and the image of ROI without renal pelvis for analyzing difference in the uptake ratio of left-right kidney and for reproducibility, set the ROI 5 times in the same images. Patients were injected $^{99m}Tc$-DMSA 1.5~1.9 MBq/kg and scanned 3 to 4 hours after injection. The each of 3 skillful radio technologists performed the comparing estimation by setting ROI. To determine statistical significance between two data, SPSS (ver. 17) Wilcoxon Signed Ranks Test was used. Results: As a result of renal phantom's experiment, we compared with average of counts Background (BKG) ratios in the setting of ROI including expanded renal pelvis and setting of excluding expanded renal pelvis. Therefore, they can obtain changed counts and changed ratios. Patient also can obtain same results. In addition, the radiopharmaceutical uptake in expanded renal pelvis was come out the remained urine that couldn't descend to ureter by the help of readout doctor. Conclusion: As above results, the case of setting ROI including expanded renal pelvis was more abnormally increasing uptake ratio than the case of setting ROI excluding expanded renal pelvis in analysis the uptake ratio in left-right kidney of hydronephrosis. Because of the work convenience and prompted analysis, the automatic ROI is generally used. But in case of the hydronephrosis study, we should set the manual ROI without expanded renal pelvis for an accurate observation of the uptake ratio of left-right kidney since the radiopharmaceutical uptake in expanded renal pelvis is the remained urine.

  • PDF