• Title/Summary/Keyword: Dams

Search Result 1,109, Processing Time 0.027 seconds

Improved Evaluation for the Seismic Capacity of Concrete Gravity Dams (콘크리트 중력식 댐의 향상된 내진성능 평가방법)

  • Kim, Yon-Gon;Kwon, Hyek-Kee
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.4 no.1 s.12
    • /
    • pp.1-14
    • /
    • 2004
  • The objective of this study is firstly to frame up the seismic safety of concrete gravity dams. It is necessary to analyze seismic response and evaluate seismic performance of concrete gravity dams during earthquake. In this study, seismic damage and dynamic analysis of concrete gravity dams using structural analysis package such as SAP2000 and MIDAS were performed. Additional dynamic water pressure due to earthquake considered as additional mass for numerical seismic analysis. According detailed analysis, the vibration through the dam structure (transverse to water flow) seems to be very critical depending on the shape of the dam. For more precise evaluation of seismic fragility of concrete gravity dams, further research is still needed.

Reproductive Toxicity Study of SM-101(sulbactam.metampicillin): Teratogenicity Study in Rats (복합항생제 SM-101(설박탐.메탐피실린)의 생식독성연구: 랫트 최기형시험)

  • 정문구;김종춘;한상섭
    • Biomolecules & Therapeutics
    • /
    • v.4 no.1
    • /
    • pp.59-67
    • /
    • 1996
  • A new composite antibiotic, SM-101(sulbactam·metampicillin), was at dose levels of 0, 375, 750 and 1500 mg/kg/day administered intravenously to pregnant Sprague-Dawley rats during the organogenetic period. Two-third of dams per group were subjected to caesarean section on day 20 of pregnancy and the remaining 10 dams per group were allowed to deliver. Effects of test substance on dams, embryonal development of F1 fetuses, as well as growth, behaviour and mating performance of F1 offspring were examined. In dams, two deaths occurred at 375 and 1500 mg/kg, respectively. The decrease in the weight of adrenal glands of the 1500 mg/kg group was observed. The prolongation of pregnancy period was found at 1500 mg/kg. F1 fetuses showed no changes related to the treatment of SM-101. In F1 offspring, the increase in spleen weight was seen at all doses treated. No treatment-related abnormalities were observed in each treated group in terms of development, behaviour and reproductive performance. In F2 fetuses, no drug-induced abnormalities occurred at all doses. The results show that the no-effect dose levels (NOELS) for dams and Fl offspring are under 375 mg/kg/day and NOELs for F1/F2 fetuses are over 1500 mg/kg/day.

  • PDF

Structural response of concrete gravity dams under blast loads

  • Sevim, Baris;Toy, Ahmet Tugrul
    • Advances in concrete construction
    • /
    • v.9 no.5
    • /
    • pp.503-510
    • /
    • 2020
  • Concrete dams are important structures due to retaining amount of water on their reservoir. So such kind of structures have to be designed against static and dynamic loads. Especially considering on critical importance against blasting threats and environmental safety, dams have to be examined according to the blast loads. This paper aims to investigate structural response of concrete gravity dams under blast loads. For the purpose Sarıyar Concrete Gravity Dam in Turkey is selected for numerical application with its 85 m of reservoir height (H), 255 m of reservoir length (3H), 72 m of bottom and 7 m of top widths. In the study, firstly 3D finite element model of the dam is constituted using ANSYS Workbench software considering dam-reservoir-foundation interaction and a hydrostatic analysis is performed without blast loads. Then, nearly 13 tons TNT explosive are considered 20 m away from downstream of the dam and this is modeled using ANSYS AUTODYN software. After that explicit analyses are performed through 40 milliseconds. Lastly peak pressures obtained from analyses are compared to empirical equations in the literature and UFC 3-340-02 standard which provide unified facilities criteria for structures to resist the effects of accidental explosions. Also analyses' results such as displacements, stresses and strains obtained from both hydrostatic and blasting analysis models are compared to each other. It is highlighted from the study that blasting analysis model has more effective than the only hydrostatic analysis model. So it is highlighted from the study that the design of dams should be included the blast loads.

Optimal design of homogeneous earth dams by particle swarm optimization incorporating support vector machine approach

  • Mirzaei, Zeinab;Akbarpour, Abolfazl;Khatibinia, Mohsen;Siuki, Abbas Khashei
    • Geomechanics and Engineering
    • /
    • v.9 no.6
    • /
    • pp.709-727
    • /
    • 2015
  • The main aim of this study is to introduce optimal design of homogeneous earth dams with oblique and horizontal drains based on particle swarm optimization (PSO) incorporating weighted least squares support vector machine (WLS-SVM). To achieve this purpose, the upstream and downstream slopes of earth dam, the length of oblique and horizontal drains and angle among the drains are considered as the design variables in the optimization problem of homogeneous earth dams. Furthermore, the seepage through dam body and the weight of dam as objective functions are minimized in the optimization process simultaneously. In the optimization procedure, the stability coefficient of the upstream and downstream slopes and the seepage through dam body as the hydraulic responses of homogeneous earth dam are required. Hence, the hydraulic responses are predicted using WLS-SVM approach. The optimal results of illustrative examples demonstrate the efficiency and computational advantages of PSO with WLS-SVM in the optimal design of homogeneous earth dams with drains.

Optimal sensor placements for system identification of concrete arch dams

  • Altunisik, Ahmet Can;Sevim, Baris;Sunca, Fezayil;Okur, Fatih Yesevi
    • Advances in concrete construction
    • /
    • v.11 no.5
    • /
    • pp.397-407
    • /
    • 2021
  • This paper investigates the optimal sensor placements and capabilities of this procedure for dynamic characteristics identification of arch dams. For this purpose, a prototype arch dam is constructed in laboratory conditions. Berke arch dam located on the Ceyhan River in city of Osmaniye is one of the highest arch dam constructed in Turkey is selected for field verification. The ambient vibration tests are conducted using initial candidate sensor locations at the beginning of the study. Enhanced Frequency Domain Decomposition and Stochastic Subspace Identification methods are used to extract experimental dynamic characteristics. Then, measurements are repeated according to optimal sensor locations of the dams. These locations are specified using the Effective Independence Method. To determine the optimal sensor locations, the target mode shape matrices which are obtained from ambient vibration tests of the selected dam with a large number of accelerometers are used. The dynamic characteristics obtained from each ambient vibrations tests are compared with each other. It is concluded that the dynamic characteristics obtained from initial measurements and those obtained from a limited number of sensors are compatible with each other. This situation indicates that optimal sensor placements determined by the Effective Independence Method are useful for dynamic characteristics identification of arch dams.

Analysis of Greenhouse Gas Research Trends of Hydropower Dams: Focusing on Foreign Cases (수력발전댐에서 온실가스 연구 동향 분석 : 국외 사례를 중심으로)

  • Park, Kyoung-deok;Jo, Won Gi;So, Yoon Hwan;Kang, Dong-hwan
    • Journal of Environmental Science International
    • /
    • v.31 no.2
    • /
    • pp.195-213
    • /
    • 2022
  • This research summarizes the generating factors of greenhouse gas (carbon dioxide, methane, nitrous oxide) in hydropower dams and related domestic/foreign researches. Microorganisms and eutrophication are the main factors in greenhouse gases in hydropower dam reservoirs. The greenhouse gas emission from the hydropower dam is affected by meteorological factors and dam operation periods, and greenhouse gases are also emitted from the outlets. The fluxes of greenhouse gas emission from the hydropower dams were -926~180,806 mg CO2 m-2d-1, -0.19~3800 mg CH4 m-2d-1, and 0.01~16.1 mg N2O m-2d-1. In South Korea, the study on the greenhouse gas emission from Korean hydropower dams has been rarely, and therefore it is inquired. This research suggested the methods on the greenhouse gas emission from Korean hydropower dams and flux calculation.

Impacts of Impoundments by Low-head and Large Dams on Benthic Macroinvertebrate Communities in Korean Streams and Rivers (소형 보와 대형 댐에 의해 형성된 저수역이 저서성 대형무척추동물 군집에 미치는 영향)

  • Kil, Hye-Kyung;Kim, Dong-Gun;Jung, Sang-Woo;Jin, Young-Hun;Hwang, Jeong-Mi;Bae, Kyung-Seok;Bae, Yeon-Jae
    • Korean Journal of Ecology and Environment
    • /
    • v.43 no.2
    • /
    • pp.190-198
    • /
    • 2010
  • This study was conducted to examine the effects of dams on benthic macroinvertebrate communities in Korean streams and rivers. Four low-head dams and three large dams were studied throughout South Korea. Sampling was taken at immediately upper (impoundment), lower (riffle area), and control (riffle area) sites from the dams during 2004-2007. The upper sites, of which substrate heterogeneity and velocity were relatively low, showed a lower degree of species richness, density, and diversity indices, which is very different from the lower and control sites. Heavily polluted streams showed a lesser degree of community differences between the upper and lower sites. In the large dams, the upper and lower sites showed very low values of species diversity indices and very high values of dominance indices compared to the control sites. In the low-head dams, however, the difference of degree of the values was relatively smaller. Compositions of the functional feeding groups and the habitat orientation groups were relatively simpler at the upper sites than at the lower sites and the degree of difference was greater in the large dams. Species richness and community indices of benthic macroinvertebrates were more significantly affected by habitat characteristics than water quality at the upper sites; however, those were more significantly related with water quality at the lower sites. In conclusion, large and low-head dams could simplify stream habitats particularly at the upper sites (impoundment), and they negatively affected on the benthic macroinvertebrate communities inhabited the habitats. The impact was larger in the large dams than in the low-head dams.

Frequency domain analysis of concrete arch dams by decoupled modal approach

  • Lotfi, Vahid
    • Structural Engineering and Mechanics
    • /
    • v.21 no.4
    • /
    • pp.423-435
    • /
    • 2005
  • A modal approach is proposed for dynamic analysis of concrete arch dam-reservoir systems in frequency domain. The technique relies on mode shapes extracted by considering the symmetric parts of total mass and stiffness matrices. Based on this method, a previously developed program is modified, and the response of Morrow Point arch dam is studied for various conditions. The method is proved to be very effective and it is an extremely convenient modal technique for dynamic analysis of concrete arch dams.

Direct frequency domain analysis of concrete arch dams based on FE-(FE-HE)-BE technique

  • Lotfi, Vahid
    • Computers and Concrete
    • /
    • v.1 no.3
    • /
    • pp.285-302
    • /
    • 2004
  • A FE-(FE-HE)-BE procedure is presented for dynamic analysis of concrete arch dams. In this technique, dam body is discretized by solid finite elements, while the reservoir domain is considered by a combination of fluid finite elements and a three-dimensional fluid hyper-element. Furthermore, foundation rock domain is handled by three-dimensional boundary element formulation. Based on this method, a previously developed program is modified, and the response of Morrow Point arch dam is studied for various conditions. Moreover, the effects of canyon shape on response of dam, is also discussed.

Evaluation of the seismic Capacity of Existing Concrete Gravity Dams (기존 콘크리트 증력식 댐 내진성능 평가)

  • 소진호;김용곤;정영수
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2001.09a
    • /
    • pp.216-223
    • /
    • 2001
  • The necessity of the seismic capacity evaluation of existing concrete gravity dams i: through the Izmit, Turkey and JiJi, Taiwan earthquake in 1999. In this study, the method seismic capacity evaluation of existing concrete gravity dams in U.S. A., Japan and Canada reviewed, applied them to the concrete gravity dam in use. Evaluation of the seismic ca approach using three levels that are level 1 - Screening, level 2 - Pseudostatic Metho level 3 - Dynamic Analysis, Method.

  • PDF