• 제목/요약/키워드: Damping-Performance

검색결과 1,250건 처리시간 0.023초

Probability-based prediction of residual displacement for SDOF using nonlinear static analysis

  • Feng, Zhibin;Gong, Jinxin
    • Earthquakes and Structures
    • /
    • 제22권6호
    • /
    • pp.571-584
    • /
    • 2022
  • The residual displacement ratio (RDRs) response spectra have been generally used as an important means to evaluate the post-earthquake repairability, and the ratios of residual to maximum inelastic displacement are considered to be more appropriate for development of the spectra. This methodology, however, assumes that the expected residual displacement can be computed as the product of the RDRs and maximum inelastic displacement, without considering the correlation between these two variables, which inevitably introduces potential systematic error. For providing an adequately accurate estimate of residual displacement, while accounting for the collapse resistance performance prior to the repairability evaluation, a probability-based procedure to estimate the residual displacement demands using the nonlinear static analysis (NSA) is developed for single-degree-of-freedom (SDOF) systems. To this end, the energy-based equivalent damping ratio used for NSA is revised to obtain the maximum displacement coincident with the nonlinear time history analysis (NTHA) results in the mean sense. Then, the possible systematic error resulted from RDRs spectra methodology is examined based on the NTHA results of SDOF systems. Finally, the statistical relation between the residual displacement and the NSA-based maximum displacement is established. The results indicate that the energy-based equivalent damping ratio will underestimate the damping for short period ranges, and overestimate the damping for longer period ranges. The RDRs spectra methodology generally leads to the results being non-conservative, depending on post-yield stiffness. The proposed approach emphasizes that the repairability evaluation should be based on the premise of no collapse, which matches with the current performance-based seismic assessment procedure.

Compound damping cable system for vibration control of high-rise structures

  • Yu, Jianda;Feng, Zhouquan;Zhang, Xiangqi;Sun, Hongxin;Peng, Jian
    • Smart Structures and Systems
    • /
    • 제29권4호
    • /
    • pp.641-652
    • /
    • 2022
  • High-rise structures prone to large vibrations under the action of strong winds, resulting in fatigue damage of the structural components and the foundation. A novel compound damping cable system (CDCS) is proposed to suppress the excessive vibrations. CDCS uses tailored double cable system with increased tensile stiffness as the connecting device, and makes use of the relative motion between the high-rise structure and the ground to drive the damper to move back-and-forth, dissipating the vibration mechanical energy of the high-rise structure so as to decaying the excessive vibration. Firstly, a third-order differential equation for the free vibration of high-rise structure with CDCS is established, and its closed form solution is obtained by the root formulas of cubic equation (Shengjin's formulas). Secondly, the analytical solution is validated by a laboratory model experiment. Thirdly, parametric analysis is conducted to investigate how the parameters affect the vibration control performance. Finally, the dynamic responses of the high-rise structure with CDCS under harmonic and stochastic excitations are calculated and its vibration mitigation performance is further evaluated. The results show that the CDCS can provide a large equivalent additional damping ratio for the vibrating structures, thus suppressing the excessive vibration effectively. It is anticipated that the CDCS can be used as a good alternative energy dissipation system for vibration control of high-rise structures.

Chattering에 의한 위성 탑재체 지향성능저하 최소화를 위한 반능동제어기법 성능분석 (Performance Investigation of Semi-Active Control Logic to Minimize a Pointing Performance Degradation of On-Board Payload by Chattering Effects)

  • 오현웅;최영준
    • 한국항공우주학회지
    • /
    • 제38권9호
    • /
    • pp.882-889
    • /
    • 2010
  • 수동형 진동제어 방식과 같이 시스템이 안정되며, 수동형에 비해 높은 제진 효과가 기대되는 반능동 진동제어 방식은 시스템의 안정화가 요구되는 우주구조물의 제진방법에 유효한 진동제어 방식중 하나이다. On-Off 제어방식에 근거한 반능동 제어는 On-Off 스위칭 시에 전달력의 불연속성으로 인한 chattering을 발생시킬 수 있으며, 이는 탑재체 구조물의 고유진동수와의 커플링으로 인하여 지향성능을 저하시키는 원인으로 작용할 수 있다. 본 논문에서는 chattering 영향 최소화를 통한 지향성능향상을 목적으로 LQ(Linear Quadratic)이론에 기반한 가변 감쇠형 반능동 제어기법을 제안하였다. 시뮬레이션 결과는 본 논문에서 제안한 반능동 제어기법은 기존의 skyhook와 LQ를 기반으로 하는 Bang-Bang 반능동 제어기법과 비교하여 높은 진동절연 성능을 나타내고 있다.

Structural Design of Nakanoshima Festival Tower West that Achieved High-Grade Seismic Performance

  • Kumano, Takehito;Yoshida, Satoshi;Saburi, Kazuhiro
    • 국제초고층학회논문집
    • /
    • 제6권3호
    • /
    • pp.217-226
    • /
    • 2017
  • This paper summarizes the structural concept and design of the "Nakanoshima Festival Tower West" in Osaka, Japan, which is 200m high and has a super-high damping system. Its superstructure is mainly composed of a central core and outer tube frames. It has a bottom truss structure at the boundary between the low-rise and mid-rise sections of the building, where the column arrangement is changed. Besides, the high-rise section of the building has a neck truss structure. These truss structures smoothly transfer the axial forces of the columns and reduce the flexural deformations induced by horizontal loads. Oil dampers with extremely high damping capacity are installed in the rigid walls named the "Big Wall Frames" of the low-rise section. Moreover, many braces and damping devices are well arranged in the center core of each story. The damping effects of these devices ensure that all structural members are remain within the elastic range and that story drifts are within 1/150 in large earthquakes. This super-high damping structure in the low-rise section is named the "Damping Layer". The whole structural system is named the "Super Damping Structure". The whole structural systems enhance the building's safety, comfort and Business Continuity Planning (BCP) under large earthquakes.

능동 구속감쇠층을 이용한 아크형태 셸 모델에 대한 진동특성 연구 (Vibration Characteristic Study of Arc Type Shell Using Active Constrained Layer Damping)

  • 고성현;박현철;황운봉;박철휴
    • 한국소음진동공학회논문집
    • /
    • 제14권3호
    • /
    • pp.193-200
    • /
    • 2004
  • The Active Constrained Layer Damping(ACLD) combines the simplicity and reliability of passive damping with the low weight and high efficiency of active control to attain high damping characteristics. The proposed ACLD treatment consists of a viscoelastic damping which is sandwiched between an active piezoelectric layer and a host structure. In this manner, the smart ACLD consists of a Passive Constrained Layer Damping(PCLD) which is augmented with an active control in response to the structural vibrations. The arc type shell model is introduced to describe the interactions between the vibrating host structure, piezoelectric actuator and viscoelastic damping. The system is modeled by applying ARMAX model and changing a state-space form through the system identification method. An optimum control law for the piezo actuator is obtain by LQR(Linear Quadratic Regulator) method. The performance of the ACLD system is determined and compared with PCLD in order to demonstrate the effectiveness of the ACLD treatment. Also, the actuation capability of a piezo actuator is examined experimentally by varying thickness of viscoelastic material(VEM).

기판에 인접한 미소거울의 회전 점성감쇠 (Potational Viscous Damping of On-substrate Micromirrors)

  • 김응삼;한기호;조영호;김문언
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제50권5호
    • /
    • pp.243-248
    • /
    • 2001
  • In this paper, we present theoretical and experimental study on the viscous damping of the on-substrate torsional micromirrors, oscillating near the silicon substrates. In this theoretical study, we develop theoretical models and test structures for the viscous damping of the on-substrate torsional micromirrors. From a finite element analysis, we estimate the theoretical damping coefficients of the torsional micromirrors. From a finite element analysis, we estimate the theoretical damping coefficients of the torsional micromirrors, fabricated by the surface-micromaching process. From the electrostatic test of the fabricated devices, frequency-dependent rotationalvelocity of the micromirrors has been measured at the atmospheric pressure using devices, frequency-dependent rotational velocity of the micromirrors has been measured at the atmospheric pressure using the Mach-Zehnder interferometer system. Experimental damping coefficients have been extracted from the least square fit of the measured rotational velocity within the filter bandwidth of 150 kHz. We have compared the theoretical values and the experimental results on the dynamic performance of the micromirrors. The theoretical analysis overstimates the resonant frequency in the amount of 15%, while underestimating the viscous damping in the factors of 10%.

  • PDF

5×5 부분핵연료 집합체의 감쇠추정을 위한 실험적 연구 (Experimental Study on the Damping Estimation of the 5×5 Partial Fuel Assembly)

  • 이강희;윤경호;송기남
    • 한국소음진동공학회논문집
    • /
    • 제16권2호
    • /
    • pp.163-168
    • /
    • 2006
  • The PWR Nuclear Fuel assembly consists of more than 250 fuel rods that are supported by leaf springs in the cells of more than 10 Spacer Grids (SG) along the rod length. Since it is not easy to conduct mechanical tests on a full-scale model basis, the small-scaled rod bundle $(5\times5)$ which is called partial fuel assembly is generally used for various performance tests during the development stage. As one of the small-scaled tests, a flow test should be carried out in order to verify the performance of the spacer grid to obtain the Flow-Induced Vibration (FIV) characteristics of the scaled fuel assembly over the specified flow range. A vibration test should be also performed to obtain the modal parameters of the assembly prior to the flow test. In this study, we want to develop the estimation procedure of the damping ratio for the scaled test assembly. For the damping factor of the partial fuel assembly and the grid cage at the first vibration mode, as one of the vibration tests, a so-called pluck testing has been performed in air as a preliminary test prior to in-flow damping measurement test. Logarithmic decrement method is used for calculation of the damping ratio. Estimated damping ratio of the partial fuel assembly is about $0.7\%$ with reasonable error of $2\%$ for the previous results. Nonlinear behavior of the partial fuel assembly might be stem mainly from the rod-grid support configuration.

Experimental study of vibration characteristics of FRP cables based on Long-Gauge strain

  • Xia, Qi;Wu, JiaJia;Zhu, XueWu;Zhang, Jian
    • Structural Engineering and Mechanics
    • /
    • 제63권6호
    • /
    • pp.735-742
    • /
    • 2017
  • Steel cables as the most important components are widely used in the certain types of structures such as cable-supported bridges, but the long-span structures may result in an increase in fatigue under high stress and corrosion of steel cables. The traditional steel cable is becoming a more evident hindrance. Fiber Reinforced Polymer (FRP) cables with lightweight, high-strength are widely used in civil engineering, but there is little research in vibrational characteristics of FRP cables, especially on the damping characteristic. This article studied the two methods to evaluate dynamical damping characteristic of basalt FRP(BFRP) and glass FRP(GFRP) cables. First, the vibration tests of the B/G FRP cables with different diameter and different cable force were executed. Second, the cables forces were calculated using dynamic strain, static strain and dynamic acceleration respectively, which were further compared with the measured force. Third, experimental modal damping of each cables was calculated by the half power point method, and was compared with the calculation by Rayleigh damping theory and energy dissipation damping theory. The results indicate that (1) The experimental damping of FRP cables decreases with the increase of cable force, and the trend of experimental damping changes is roughly similar with the theoretical damping. (2) The distribution of modal damping calculated by Rayleigh damping theory is closer to the experimental results, and the damping performance of GFRP cables is better than BFRP cables.

작동유체 질량을 고려한 유연우주트러스구조물 제진용 반능동 댐퍼의 성능분석 (Performance Investigation of Semi-Active Damper Considering Mass Modeling of Functional Fluid)

  • 오현웅;최영준;이경민
    • 한국항공우주학회지
    • /
    • 제37권5호
    • /
    • pp.450-456
    • /
    • 2009
  • 수동형 진동제어 방식과 같이 시스템이 안정되며, 수동형에 비해 높은 제진 효과가 기대되는 반능동 진동제어 방식은 시스템의 안정화가 요구되는 우주구조물의 제진방법에 유효한 진동제어 방식중 하나이다. 본 논문에서는 유연우주트러스구조물의 진동제어를 위해 고안된 반능동 댐퍼내 작동유체의 질량을 모델링에 고려했을 경우의 제진특성을 분석하였고 댐퍼내 작동유체의 점성이 부족감쇠를 유지 할 경우, 작동유체 질량 적용에 따른 반능동 댐퍼의 제진효과를 확인하였으며 이를 토대로 반능동 댐퍼의 성능향상을 위한 설계방법을 제시하였다.

A numerical investigation of seismic performance of large span single-layer latticed domes with semi-rigid joints

  • Zhang, Huidong;Han, Qinghua
    • Structural Engineering and Mechanics
    • /
    • 제48권1호
    • /
    • pp.57-75
    • /
    • 2013
  • It is still inadequate for investigating the highly nonlinear and complex mechanical behaviors of single-layer latticed domes by only performing a force-based demand-capacity analysis. The energy-based balance method has been largely accepted for assessing the seismic performance of a structure in recent years. The various factors, such as span-to-rise ratio, joint rigidity and damping model, have a remarkable effect on the load-carrying capacity of a single-layer latticed dome. Therefore, it is necessary to determine the maximum load-carrying capacity of a dome under extreme loading conditions. In this paper, a mechanical model for members of the semi-rigidly jointed single-layer latticed domes, which combines fiber section model with semi-rigid connections, is proposed. The static load-carrying capacity and seismic performance on the single-layer latticed domes are evaluated by means of the mechanical model. In these analyses, different geometric parameters, joint rigidities and roof loads are discussed. The buckling behaviors of members and damage distribution of the structure are presented in detail. The sensitivity of dynamic demand parameters of the structures subjected to strong earthquakes to the damping is analyzed. The results are helpful to have a better understanding of the seismic performance of the single-layer latticed domes.