• Title/Summary/Keyword: Damping Requirement

Search Result 43, Processing Time 0.021 seconds

Seismic response of active or semi active control for irregular buildings based on eigenvalues modification

  • Pnevmatikos, Nikos G.;Hatzigeorgiou, George D.
    • Earthquakes and Structures
    • /
    • v.6 no.6
    • /
    • pp.647-664
    • /
    • 2014
  • A reduction of the response of irregular structures subjected to earthquake excitation by control devices equipped by suitable control algorithm is proposed in this paper. The control algorithm, which is used, is the pole placement one. A requirement of successful application of pole placement algorithm is a definition-selection of suitable poles (eigen-values) of controlled irregular structures. Based on these poles, the required action is calculated and applied to the irregular structure by means of control devices. The selection of poles of controlled irregular structure, is a critical issue for the success of the algorithm. The calculation of suitable poles of controlled irregular structure is proposed herein by the following procedure: a fictitious symmetrical structure is considered from the irregular structure, adding vertical elements, such as columns or shear walls, at any location where is necessary. Then, the eigen-values of symmetrical structure are calculated, and are forced to be the poles of irregular controlled structure. Based on these poles and additional damping, the new poles of the controlled irregular structure are calculated. By pole placement algorithm, the feedback matrix is obtained. Using this feedback matrix, control forces are calculated at any time during the earthquake, and are applied to the irregular structure by the control devices. This procedure results in making the controlled irregular structure to behave like a symmetrical one. This control strategy can be applied to one storey or to multi-storey irregular buildings. Furthermore, the numerical results were shown that with small amount of control force, a sufficient reduction of the response of irregular buildings is achieved.

Evaluation of Sound Insulation Performance of a Unit Cabin Mock-up (유니트 캐빈 목업(mock-up)의 차음성능평가)

  • Kim, Hyun-Sil;Kim, Sang-Ryul;Kim, Bong-Ki;Kim, Jae-Seung;Lee, Sung-Hyun
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.48 no.1
    • /
    • pp.49-55
    • /
    • 2011
  • Sound insulation performance of a unit cabin mock-up is studied, where two identical rooms simulating cruise ship cabin are installed. STL (Sound Transmission Loss) measurement in the mock-up shows that STL of the partition between rooms is degraded by imperfect door ceiling and gap between wall and floor. It is also observed that gap around lighting and electrical outlet slightly affect the STL in high frequency ranges, since lighting and electrical outlet are supported by mineral wool in the back side due to fire-resistance requirement. Even after all possible gaps are sealed, STL of the partition is found to be lower than that measured in the laboratory by 9 dB. Measurement of SBN (Structure-Borne Noise) reveals that flanking transmission of SBN along the steel deck floor can severely deteriorate STL of the partition. Statistical energy analysis (SEA) of the mock-up confirms importance of the floor SBN control, in which increasing damping is essential to ensure high STL.

Seismic Performance and Flexural Over-strength of Hollow Circular RC Column with Longitudinal Steel Ratio 2.017% (축방향철근비 2.017%인 중공 원형 RC 기둥의 내진성능과 휨 초과강도)

  • Ko, Seong-Hyun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.21 no.1
    • /
    • pp.1-8
    • /
    • 2017
  • Three small scale hollow circular reinforced concrete columns with aspect ratio 4.5 were tested under cyclic lateral load with constant axial load. Diameter of section is 400 mm, hollow diameter is 200 mm. The selected test variable is transverse steel ratio. Volumetric ratios of spirals of all the columns are 0.302~0.604% in the plastic hinge region. It corresponds to 45.9~91.8% of the minimum requirement of confining steel by Korean Bridge Design Specifications, which represent existing columns not designed by the current seismic design specifications or designed by seismic concept. The longitudinal steel ratio is 2.017%. The axial load ratio is 7%. This paper describes mainly crack behavior, load-displacement hysteresis loop, seismic performance such as equivalent damping ratio, residual displacement and effective stiffness and flexural over-strength of circular reinforced concrete bridge columns with respect to test variable. The regulation of flexural over-strength is adopted by Korea Bridge Design Specifications (Limited state design, 2012). The test results are compared with nominal strength, result of nonlinear moment-curvature analysis and the design specifications such as AASHTO LRFD and Korea Bridge Design Specifications(Limited state design).