• Title/Summary/Keyword: Damping Hinge

Search Result 32, Processing Time 0.029 seconds

Stress Analysis and Design Improvement to Prevent Failure of the Damping Hinges of Built-in Refrigerators (빌트인 냉장고 댐핑힌지의 응력해석 및 파손방지를 위한 설계개선)

  • Lee, Boo-Youn
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.19 no.2
    • /
    • pp.81-88
    • /
    • 2020
  • The damping hinge of a built-in refrigerator was examined in terms of its stress and fatigue life. Analysis of the initial design showed that stress concentration occurred at the concave surface of the hinge lever, which was broken during the door opening-and-closing endurance test of the prototype. The maximum von Mises stress at this location exceeded the yield strength. In addition, Goodman fatigue analysis of the initial design showed that the fatigue life at this location was consistent with the failure observed during the endurance test. Based on these results, an improved design for the damping hinge was derived. Analysis of this improved design showed that the stress concentration in the hinge lever of the initial design was eliminated. In this case, the maximum stress occurred at the position where the hinge lever was in contact with the door stopping pin, and the maximum von Mises stress was smaller than the yield strength. Goodman fatigue analysis of the improved design indicated that the fatigue life of the entire damping hinge was infinite. It was therefore concluded that the improved design does not suffer from fatigue damage during the endurance test.

Seismic performance of a rocking bridge pier substructure with frictional hinge dampers

  • Cheng, Chin-Tung;Chen, Fu-Lin
    • Smart Structures and Systems
    • /
    • v.14 no.4
    • /
    • pp.501-516
    • /
    • 2014
  • The rocking pier system (RPS) allows the columns to rock on beam or foundation surfaces during the attacks of a strong earthquake. Literatures have proved that seismic energy dissipated by the RPS through the column impact is limited. To enhance the energy dissipation capacity of a RPS bridge substructure, frictional hinge dampers (FHDs) were installed and evaluated by shaking table tests. The supplemental FHDs consist of two brass plates sandwiched by three steel plates. The strategy of self-centering design is to isolate the seismic energy by RPS at the columns and then dissipate the energy by FHDs at the bridge deck. Component tests of FHD were first conducted to verify the friction coefficient and dynamic characteristic of the FHDs. In total, 32 shaking table tests were conducted to investigate parameters such as wave forms of the earthquake (El Centro 1940 and Kobe 1995) and normal forces applied on the friction dampers. An analytical model was also proposed to compare with the tested damping of the bridge sub-structure with or without FHDs.

Earthquake effects on the energy demand of tall reinforced concrete walls with buckling-restrained brace outriggers

  • Beiraghi, Hamid
    • Structural Engineering and Mechanics
    • /
    • v.63 no.4
    • /
    • pp.521-536
    • /
    • 2017
  • Reinforced concrete core-wall structures with buckling-restrained brace outriggers are interesting systems which have the ability to absorb and dissipate energy during strong earthquakes. Outriggers can change the energy demand in a tall building. In this paper, the energy demand was studied by using the nonlinear time history analysis for the mentioned systems. First, the structures were designed according to the prescriptive codes. In the dynamic analysis, three approaches for the core-wall were investigated: single plastic hinge (SPH), three plastic hinge (TPH) and extended plastic hinge (EPH). For SPH approach, only one plastic hinge is allowed at the core-wall base. For TPH approach, three plastic hinges are allowed, one at the base and two others at the upper levels. For EPH approach, the plasticity can extend anywhere in the wall. The kinetic, elastic strain, inelastic and damping energy demand subjected to forward directivity near-fault and ordinary far-fault earthquakes were studied. In SPH approach for all near-fault and far-fault events, on average, more than 65 percent of inelastic energy is absorbed by buckling-restrained braces in outrigger. While in TPH and EPH approaches, outrigger contribution to inelastic energy demand is reduced. The contribution of outrigger to inelastic energy absorption for the TPH and EPH approaches does not differ significantly. The values are approximately 25 and 30 percent, respectively.

Risk assessment of steel and steel-concrete composite 3D buildings considering sources of uncertainty

  • Lagaros, Nikos D.
    • Earthquakes and Structures
    • /
    • v.6 no.1
    • /
    • pp.19-43
    • /
    • 2014
  • A risk assessment framework for evaluating building structures is implemented in this study. This framework allows considering sources of uncertainty both on structural capacity and seismic demand. In particular randomness on seismic load, incident angle, material properties, floor mass and structural damping are considered; in addition the choice of fibre modelling versus plastic hinge model is also considered as a source of uncertainty. The main objective of this work is to study the contribution of these sources of uncertainty on the fragilities of steel and steel-reinforced concrete composite 3D building structures. The fragility curves are expressed in the form of a two-parameter lognormal distribution where vertical statistics in conjunction with metaheuristic optimization are implemented for calculating the two parameters.

Studies on vibration control effects of a semi-active impact damper for seismically excited nonlinear building

  • Lu, Zheng;Zhang, Hengrui;Masri, Sami F.
    • Smart Structures and Systems
    • /
    • v.24 no.1
    • /
    • pp.95-110
    • /
    • 2019
  • The semi-active impact damper (SAID) is proposed to improve the damping efficiency of traditional passive impact dampers. In order to investigate its damping mechanism and vibration control effects on realistic engineering structures, a 20-story nonlinear benchmark building is used as the main structure. The studies on system parameters, including the mass ratio, damping ratio, rigid coefficient, and the intensity of excitation are carried out, and their effects both on linear and nonlinear indexes are evaluated. The damping mechanism is herein further investigated and some suggestions for the design in high-rise buildings are also proposed. To validate the superiority of SAID, an optimal passive particle impact damper ($PID_{opt}$) is also investigated as a control group, in which the parameters of the SAID remain the same, and the optimal parameters of the $PID_{opt}$ are designed by differential evolution algorithm based on a reduced-order model. The numerical simulation shows that the SAID has better control effects than that of the optimized passive particle impact damper, not only for linear indexes (e.g., root mean square response), but also for nonlinear indexes (e.g., component energy consumption and hinge joint curvature).

Structural Analysis of Damping Hinge for Built-in Side-by-Side Refrigerator and Design Improvement of Bracket Pin to Reduce Stress Concentration (빌트인 양문형 냉장고 댐핑힌지의 구조해석 및 브래킷핀의 응력집중 저감을 위한 설계개선)

  • Lee, Boo-Youn
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.1
    • /
    • pp.373-379
    • /
    • 2020
  • This study performed stress and fatigue life analysis of the damping hinge of a built-in side-by-side refrigerator that occurs when the door is opened to the maximum angle. An analysis of the initial design showed that stress concentration occurred at the corner between the cylinder and upper disk of the bracket pin, and the maximum stress exceeded the yield strength. The maximum stress location and the calculated fatigue life were consistent with the door opening-and-closing endurance test results for a prototype. Three cases of design improvement for the bracket pin were derived with the aim of reducing the stress concentration that appeared in the initial design. An analysis of the cases showed that inserting a fillet between the disk and the cylinder of the bracket pin reduced the stress and increased the fatigue life. Moreover, changing the disk into two steps was more favorable. In conclusion, the best design improvement was the case that the disk was changed to two steps and the fillet with a large radius was inserted. In that case, the stress was the smallest and the fatigue life was infinite.

The vertical spanning strip wall as a coupled rocking rigid body assembly

  • Sorrentino, Luigi;Masiani, Renato;Griffith, Michael C.
    • Structural Engineering and Mechanics
    • /
    • v.29 no.4
    • /
    • pp.433-453
    • /
    • 2008
  • The equation of motion of a one way (vertical) spanning strip wall, as an assembly of two rigid bodies, is presented. Only one degree of freedom is needed to completely describe the wall response as the bodies are assumed to be perfectly rectangular and are allowed to rock but not to slide horizontally. Furthermore, no arching action occurs since vertical motion of the upper body is not restrained. Consequently, the equation of motion is nonlinear, with non constant coefficients and a Coriolis acceleration term. Phenomena associated with overburden to self weight ratio, motion triggering, impulsive energy dissipation, amplitude dependency of damping and period of vibration, and scale effect are discussed, contributing to a more complete understanding of experimental observations and to an estimation of system parameters based on the wall characteristics, such as intermediate hinge height and energy damping, necessary to perform nonlinear time history analyses. A comparison to a simple standing, or parapet, wall is developed in order to better highlight the characteristics of this assembly.

Parametric study of pendulum type dynamic vibration absorber for controlling vibration of a two DOF structure

  • Bur, Mulyadi;Son, Lovely;Rusli, Meifal;Okuma, Masaaki
    • Earthquakes and Structures
    • /
    • v.13 no.1
    • /
    • pp.51-58
    • /
    • 2017
  • Passive dynamic vibration absorbers (DVAs) are often used to suppress the excessive vibration of a large structure due to their simple construction and low maintenance cost compared to other vibration control techniques. A new type of passive DVA consists of two pendulums connected with spring and dashpot element is investigated. This research evaluated the performance of the DVA in reducing the vibration response of a two degree of freedom shear structure. A model for the two DOF vibration system with the absorber is developed. The nominal absorber parameters are calculated using a Genetic Algorithm(GA) procedure. A parametric study is performed to evaluate the effect of each absorber parameter on performance. The simulation results show that the optimum condition for the absorber frequencies and damping ratios is mainly affected by pendulum length, mass, and the damping coefficient of the pendulum's hinge joint. An experimental model validates the theoretical results. The simulation and experimental results show that the proposed technique is able be used as an effective alternative solution for reducing the vibration response of a multi degree of freedom vibration system.

Dynamic identification of soil-structure system designed by direct displacement-based method for different site conditions

  • Mahmoudabadi, Vahidreza;Bahar, Omid;Jafari, Mohammad Kazem;Safiey, Amir
    • Structural Engineering and Mechanics
    • /
    • v.71 no.4
    • /
    • pp.445-458
    • /
    • 2019
  • This study mainly aims to assess the performance of soil-structure systems designed by direct displacement-based method coupled with strong column-weak beam design concept through various system identification techniques under strong ground motions. To this end, various system identification methods are employed to evaluate the dynamic characteristics of a structure (i.e., modal frequency, system damping, mode shapes, and plastic hinge formation pattern) under a strong seismic excitation considering soil-structure interaction for different site conditions as specified by ASCE 7-10. The scope of the study narrowed down to the code-complying low- to high-rise steel moment resisting frames with various heights (4, 8, 12, 16-story). The comparison of the result of soil-structure systems with fix-based support condition indicates that the modal frequencies of these systems are highly influenced by the structure heights, specifically for the softer soils. This trend is more significant for higher modes of the system which can considerably dominate the response of structures in which the higher modes have more contribution in dynamic response. Amongst all studied modes of the vibration, the damping ratio estimated for the first mode is relatively the closet to the initial assumed damping ratios. Moreover, it was found that fewer plastic hinges are developed in the structure of soil-structure systems with a softer soil which contradicts the general expectation of higher damageability of such structural systems.

Beam-Column Junction Type Damper of Seismic Performance Enhancement for Structures (구조물의 내진성능 보강을 위한 보-기둥 접합형 감쇠장치)

  • Noh, Jung-Tae;Woo, Sung-Sik;Lee, Sang-Hyun;Chung, Lan
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2009.10a
    • /
    • pp.855-863
    • /
    • 2009
  • In this study, a beam-column junction type damper is proposed which saves the inner and outer space for the installation of damping devices and allows easy adjustment of control performance The result of the numerical analysis indicated that the displacement response and base shear of a single degree of freedom system by seismic load, El Centro 1940 was reduced with yield moment of the joint hinge and the specific yield moment ratio $\delta$ of the joint hinge existed for the optimal seismic performance. In addition, the dynamic nonlinear characteristics, effects of yielding and dependence of natural period of bi-linear system with the junction type damper is identified. The analysis of multi-degree of freedom system showed that responses of the controlled structures was reduced significantly as the number of a story increases and yield moment ratio decreases when the system is excited by seismic load and sine wave. On top of that, it was also observed that energy dissipation at the joint connected with the dampers was remarkable during excitation.

  • PDF