• 제목/요약/키워드: Damper design procedure

검색결과 66건 처리시간 0.022초

응답스펙트럼을 활용한 감쇠장치 예비 설계절차 제시 (Preliminary Design Procedure for Practical Application of Dampers Using Earthquake Response Spectrum)

  • 노지은;이상현
    • 한국지진공학회논문집
    • /
    • 제23권2호
    • /
    • pp.109-117
    • /
    • 2019
  • In this study, a design procedure for the practical application of the dampers to building structures under earthquake loads was presented by using earthquake response spectrum. Nonlinear time history results using a 10 story building structure installed with damper verified the effectiveness of the proposed procedure by showing that the structural response could be reduced to the target performance level for seismic loads. Since the proposed design procedures are based on response spectrum seismic analysis result of the original structure, the capacity, location and the number of damper and the consequent response reduction effects can be preliminarily determined without performing the nonlinear time history analysis.

건축 구조물의 지진응답 제어를 위해 제안된 MR감쇠기 설계 절차의 수치적 검증 (Numerical Verification of the Proposed Design Procedure of MR Damper for Seismic Response Control of Building Structure)

  • 이상현;민경원;이루지
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2005년도 학술발표회 논문집
    • /
    • pp.521-528
    • /
    • 2005
  • In our previous study, we have developed a preliminary design procedure of MR dampers for controlling seismic response of building structures. In this paper, the effectiveness the proposed method is verified through the numerical analysis of the structures with various period and story number, and twenty earthquake loads are used for statistical assessment. The comparison between the proposed method and simplified sequential search algorithm indicates that the capacity, number and the placement of the MR damper which can achieve the given performance objective are reasonably determined using the proposed design procedure.

  • PDF

마찰 감쇠기를 사용한 구조물의 보강 설계법 제안 (Seismic Retrofit Design Procedure Using a Friction Damper)

  • 문기훈;한상환;조한철;이강석
    • 한국지진공학회논문집
    • /
    • 제15권6호
    • /
    • pp.45-53
    • /
    • 2011
  • 본 연구의 목적은 마찰 감쇠기를 사용한 기존 구조물의 제진보강 설계절차를 제시하는 것이다. 보강된 구조물의 목표 지붕층 변위는 기존 구조물이 급격한 강도의 저감없이 보유내력을 발휘할 수 있는 최대변위를 초과하지 않도록 결정하였다. 보강 구조물의 변위는 비탄성 변위비 제안식을 이용하여 예측하였다. 제안된 방법의 유효성을 검증하기 위하여 80개의 지반운동 데이터를 사용하여 비선형 동적해석을 수행하였다. 해석결과 제안된 방법은 보강 구조물의 지붕층 변위를 정확히 예측할 수 있는 것으로 나타났다.

이력형 감쇠장치를 이용한 내진보강 예비설계절차 (A Preliminary Design Procedure for Seismic Retrofit Using Hysteretic Dampers)

  • 정국기;유은종
    • 한국지진공학회논문집
    • /
    • 제26권2호
    • /
    • pp.59-69
    • /
    • 2022
  • The use of dampers is being considered a means to improve the seismic performance of buildings. It may take considerable time and effort to find an optimal design solution since repeated three-dimensional nonlinear time history analyses are required. Therefore, a preliminary design procedure for seismic retrofit using hysteretic dampers was proposed in this study. In the proposed procedure, the amount of retrofit (required number of dampers) is estimated from the capacity curve of the building before retrofit and allowable story drift of the building. In combining the capacity curves of the building and the dampers, the deformation demand for the dampers can be easily checked against their deformation capacity. The equations to transform the device displacement to roof displacement for the combination of capacity curves are developed. The proposed procedure was applied to the seismic retrofit design of sample buildings. The study found that the estimated capacity curve was very close to the actual capacity curve obtained from the pushover analysis, which can determine an appropriate configuration to meet the required seismic performance.

컨테이너 상차 시 트레일러 현가장치의 최적설계 (Optimum Design of Suspension in Loading Container on Trailer)

  • 김재헌;홍도관;김중완;전언찬;안찬우
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 추계학술대회논문집A
    • /
    • pp.710-715
    • /
    • 2001
  • This research is presented for optimizing the coefficients of spring and damper by impact load which is applied to a trailer when the containers are loaded up trailer. The procedure utilize the condition that two containers, initial velocity of container, initial height of container and maximum of suspension stroke. The coefficients of spring and damper are calculated numerically through Newmark method uses finite difference expansions. The procedure of calculation is applied by one DOFs of mass-spring-damper system. The coefficients of spring and damper have large value as increase of height or decrease of stroke. The result of calculation is investigated and is used AGV design.

  • PDF

사장교 케이블의 감쇠성능 향상을 위한 댐퍼의 비선형성 연구 (Study of the non-linearity of cable damper to enhance damping performance of stay cable)

  • 서주원;고현무
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 춘계학술대회논문집
    • /
    • pp.147-156
    • /
    • 2007
  • This study offers a design procedure of optimum cable damper for multi-mode vibration control with nonlinear damper and also investigate the relation between mode and amplitude dependency. The proposed multi-mode damping index, which is defined as a energy loss ratio of cable potential, is a main component of optimization problem of optimum nonlinear damper. In order to include the amplitude dependency of nonlinear damper, it is assumed to exist three kinds of multi-mode patterns such as ambient vibration, support excitation and rain-win induced vibration. The optimum damper exponent depends on amplitude patterns. In case of ambient vibration, optimum factor is less than 0.5. In case of support excitation or rain-wind induced vibration is between 0.5 and 1.0. In this study, the effects of cable sag and inclination angle are included in the asymptotic design equation of damped cable structures.

  • PDF

Experimental calibration of forward and inverse neural networks for rotary type magnetorheological damper

  • Bhowmik, Subrata;Weber, Felix;Hogsberg, Jan
    • Structural Engineering and Mechanics
    • /
    • 제46권5호
    • /
    • pp.673-693
    • /
    • 2013
  • This paper presents a systematic design and training procedure for the feed-forward back-propagation neural network (NN) modeling of both forward and inverse behavior of a rotary magnetorheological (MR) damper based on experimental data. For the forward damper model, with damper force as output, an optimization procedure demonstrates accurate training of the NN architecture with only current and velocity as input states. For the inverse damper model, with current as output, the absolute value of velocity and force are used as input states to avoid negative current spikes when tracking a desired damper force. The forward and inverse damper models are trained and validated experimentally, combining a limited number of harmonic displacement records, and constant and half-sinusoidal current records. In general the validation shows accurate results for both forward and inverse damper models, where the observed modeling errors for the inverse model can be related to knocking effects in the measured force due to the bearing plays between hydraulic piston and MR damper rod. Finally, the validated models are used to emulate pure viscous damping. Comparison of numerical and experimental results demonstrates good agreement in the post-yield region of the MR damper, while the main error of the inverse NN occurs in the pre-yield region where the inverse NN overestimates the current to track the desired viscous force.

성능목표를 달성하기 위한 점탄성 감쇠기의 설계 (Design of Viscoelastic Dampers to Meet Performance Objectives)

  • 김진구;최현훈
    • 한국전산구조공학회논문집
    • /
    • 제15권2호
    • /
    • pp.329-339
    • /
    • 2002
  • 본 연구에서는 비선형 정적해석법인 능력스펙트럼 법을 이용하여 성능목표를 만족하기 위하여 필요한 점탄성 감쇠기를 설계하는 절차를 제시하였다. 점탄성 감쇠기의 적정 크기를 구하기 위해 목표 변위에서 필요한 유효감쇠 비를 구한 다음 구조물의 이력거동에 의한 등가감쇠 비와 고유감쇠 비를 이용하여 필요한 감쇠기의 감쇠를 구하였다. 점탄성 감쇠기를 설치할 경우에는 구조물의 감쇠뿐만 아니라 강성도 변화하기 때문에 반복계산이 필요하게 된다. 본 연구에서는 먼저 단자유도계에서 구조물의 설계변수를 변화시키면서 제안된 방법의 타당성을 검증하였다. 또한 10층의 철골조 건물에 적용하고 지진응답을 구하였다. 제안된 방법에 따라 설계된 감쇠기를 설치하고 수행한 시간이력해석 결과에 의하면 고려된 설계변수에 관계없이 목표변위를 만족하는 것으로 나타났다.

단자유도 건물의 지진응답제어를 위한 마찰감쇠기 설계 (Design of Friction Dampers for Seismic Response Control of a SDOF Building)

  • 민경원;성지영
    • 한국소음진동공학회논문집
    • /
    • 제20권1호
    • /
    • pp.22-28
    • /
    • 2010
  • Approximate analysis for a building installed with a friction damper is performed to get insight of its dynamic behavior. Energy balance equation is used to have a closed analytical form solution of dynamic magnification factor(DMF). It is found out that DMF is dependent on friction force ratio and resonance frequency. Approximation of DMF and equivalent damping ratio of a friction damper is proposed with such assumption that the building with a friction damper shows harmonic steady-state response and narrow banded response behavior near resonance frequency. Linear transfer function from input external force to output building displacement is suggested from the simplified DMF equation. Root mean square of a building displacement is derived under earthquake-like random excitation. Finally, design procedure of a friction damper is proposed by finding friction force corresponding to target control ratio. Numerical analysis is carried out to verify the proposed design procedure.

사장교 케이블의 감쇠성능 향상을 위한 댐퍼의 비선형성 연구 (Study of the Non-linearity of Cable Damper to Enhance Damping Performance of Stay Cable)

  • 서주원;고현무
    • 한국소음진동공학회논문집
    • /
    • 제17권9호
    • /
    • pp.785-796
    • /
    • 2007
  • This study offers a design procedure of optimum cable damper for multi-mode vibration control with nonlinear damper and also investigates the relation between mode and amplitude dependency. The proposed multi-mode damping index, which is defined as a potential energy loss ratio of cable vibration, is a main component of optimization problem of optimum nonlinear damper. In order to include the amplitude dependency of nonlinear damper, three types of multi-mode patterns such as ambient vibration, support excitation and rain-wind induced vibration are assumed. The optimum damper exponent depends on amplitude patterns. In case of ambient vibration, optimum factor is less than 0.5 and in case of support excitation or rain-wind induced vibration it is between 0.5 and 1.0.