• 제목/요약/키워드: Damage parameters

검색결과 1,537건 처리시간 0.028초

구조물 손상 탐지를 위한 시간 영역에서의 SI기법 (System Identification in Time Domain for Structural Damage Assessment)

  • 이해성;박승근
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2003년도 추계학술대회논문집
    • /
    • pp.614-618
    • /
    • 2003
  • This paper presents a system identification (SI) scheme in time domain using measured acceleration data. The error function is defined as the time integral of the least square errors between the measured acceleration and the calculated acceleration by a mathmatical model. Damping parameters as well as stiffness properties of a structure are considered as system parameters. The structural damping is modeled by the Rayleigh damping. A new regularization function defined by the L$_1$-norm of the first derivative of system parameters with respect to time is proposed to alleviate the ill-posed characteristics of inverse problems and to accommodate discontinuities of system parameters in time. The time window concept is proposed to trace variation of system parameters in time.

  • PDF

Comparison of Impedance Parameters and Occupational Therapy Evaluation in the Paretic and Non-paretic Upper Extremity of Hemiplegic Stroke Patients

  • Yoo, Chan-Uk;Kim, Jaehyung;Hwang, Youngjun;Kim, Gunho;Shin, Yong-Il;Jeon, Gyerok
    • 한국멀티미디어학회논문지
    • /
    • 제20권12호
    • /
    • pp.1980-1991
    • /
    • 2017
  • Many stroke patients undergoing rehabilitation therapy require a quantitative indicator for the evaluation of body function in paretic and non-paretic regions. In this study, the impedance parameters were acquired to assess the physical status in the upper extremity of thirty six stroke patients with hemiplegia caused by cerebral hemorrhage (10 patients) and cerebral infarction (26 patients), using bioelectrical impedance. Prediction marker (PM), phase angle (PA), PM/PA, and resistance (R) versus reactance ($X_c$) were utilized to evaluate the functional status of the paretic and non-paretic regions. In addition, the hand grip strength (HGS) and the pinch strength (lateral, palmer, tip) were measured on the upper extremity of hemiplegic stroke patients. PM was distributed in inversely proportional to HGS, but PA was distributed in proportional to HGS. However, there were a number of patients with HGS of 0, regardless of the impedance parameters (PM, PA, R vs. $X_c$). Paretic and non-paretic status in upper extremity of these patients could not be analyzed using impedance parameters. At the rehabilitation therapist's instructions, they were unable to move the hand and fingers of the paretic upper extremity by cranial nerve damage, motor nerve damage, and severe cognitive decline.

A vibration based acoustic wave propagation technique for assessment of crack and corrosion induced damage in concrete structures

  • Kundu, Rahul Dev;Sasmal, Saptarshi
    • Structural Engineering and Mechanics
    • /
    • 제78권5호
    • /
    • pp.599-610
    • /
    • 2021
  • Early detection of small concrete crack or reinforcement corrosion is necessary for Structural Health Monitoring (SHM). Global vibration based methods are advantageous over local methods because of simple equipment installation and cost efficiency. Among vibration based techniques, FRF based methods are preferred over modal based methods. In this study, a new coupled method using frequency response function (FRF) and proper orthogonal modes (POM) is proposed by using the dynamic characteristic of a damaged beam. For the numerical simulation, wave finite element (WFE), coupled with traditional finite element (FE) method is used for effectively incorporating the damage related information and faster computation. As reported in literature, hybrid combination of wave function based wave finite element method and shape function based finite element method can addresses the mid frequency modelling difficulty as it utilises the advantages of both the methods. It also reduces the dynamic matrix dimension. The algorithms are implemented on a three-dimensional reinforced concrete beam. Damage is modelled and studied for two scenarios, i.e., crack in concrete and rebar corrosion. Single and multiple damage locations with different damage length are also considered. The proposed methodology is found to be very sensitive to both single- and multiple- damage while being computationally efficient at the same time. It is observed that the detection of damage due to corrosion is more challenging than that of concrete crack. The similarity index obtained from the damage parameters shows that it can be a very effective indicator for appropriately indicating initiation of damage in concrete structure in the form of spread corrosion or invisible crack.

실험 모드해석을 이용한 균열 적층복합판의 손상평가 (Damage Evaluation of Cracked Laminated Composite Plates Using Experimental Modal Analysis)

  • 김주우
    • 한국강구조학회 논문집
    • /
    • 제24권4호
    • /
    • pp.399-410
    • /
    • 2012
  • 본 연구에서는 실험적 모드해석 기법을 이용하여 캔틸레버 및 양단고정 직사각형 적층복합판의 동적 테스트가 수행되었다. 균열 성장으로 인한 손상평가를 위하여 적층복합판에 인위적인 단계별 손상(균열)을 가하였으며, 충격해머 모드실험에 의해 얻어진 주파수응답함수(FRF), MAC(Modal Assurance Criterion) 값 및 모드매개변수(진동수, 모드형상, 감쇠비)의 변화를 분석하였다. 각 단계별 손상에 대한 적층복합판의 실험적 모드매개변수를 검증하기 위하여 유한요소해석으로부터 구한 고유진동수와 모드형상을 비교하였다. 손상은 벤치마크로서의 유한요소모델을 보정하는 과정으로부터 얻게 되는 적층복합판의 기하학적 특성 및 구조적 거동의 변화를 통하여 평가될 수 있음을 보여주었다.

ESTIMATION OF DUCTILE FRACTURE BEHAVIOR INCORPORATING MATERIAL ANISOTROPY

  • Choi, Shin-Beom;Lee, Dock-Jin;Jeong, Jae-Uk;Chang, Yoon-Suk;Kim, Min-Chul;Lee, Bong-Sang
    • Nuclear Engineering and Technology
    • /
    • 제44권7호
    • /
    • pp.791-798
    • /
    • 2012
  • Since standardized fracture test specimens cannot be easily extracted from in-service components, several alternative fracture toughness test methods have been proposed to characterize the deformation and fracture resistance of materials. One of the more promising alternatives is the local approach employing the SP(Small Punch) testing technique. However, this process has several limitations such as a lack of anisotropic yield potential and tediousness in the damage parameter calibration process. The present paper investigates estimation of ductile fracture resistance(J-R) curve by FE(Finite Element) analyses using an anisotropic damage model and enhanced calibration procedure. In this context, specific tensile tests to quantify plastic strain ratios were carried out and SP test data were obtained from the previous research. Also, damage parameters constituting the Gurson-Tvergaard-Needleman model in conjunction with Hill's 48 yield criterion were calibrated for a typical nuclear reactor material through a genetic algorithm. Finally, the J-R curve of a standard compact tension specimen was predicted by further detailed FE analyses employing the calibrated damage parameters. It showed a lower fracture resistance of the specimen material than that based on the isotropic yield criterion. Therefore, a more realistic J-R curve of a reactor material can be obtained effectively from the proposed methodology by taking into account a reduced load-carrying capacity due to anisotropy.

재활성화 분극시험에 의한 Cr-Mo-V강의 시효열화 손상 평가 (An Evaluation of Aging Degradation Damage for Cr-Mo-V Steel by Electrochemical Potentiokinetic Reactivation Test)

  • 권일현;나성훈;송기욱;유효선
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 춘계학술대회논문집A
    • /
    • pp.49-54
    • /
    • 2000
  • Cr-Mo-V steel is widely used as a material for the turbine structural component in fossil power plants. It is well known that this material shows the various material degradation phenomenons such as temper embrittlement, carbide coarsening. and softening etc. or ins to the severe operation conditions as high temperature and high pressure. These deteriorative factors cause tile change of mechanical properties as reduction of fracture toughness. Therefor it is necessary to evaluate tile extent of degradation damage for Cr-Mo-V steel in life assessment of turbine structural components. In this paper. the electrochemical potentiokinetic reactivation(EPR) test in $50wt%-Ca(NO_3)_2$ solution is performed to develop the newly technique for degradation damage evaluation of Cr-Mo-V steel. The results obtained from the EPR test are compared with those in small punch(SP) tests recommended by semi-nondestructive testing method using miniaturized specimen. The evaluation parameters used in EPR test are tile reactivation current density$(I_R)$ and charge$(Q_{RC})$ reactivation rate$(I_R/I_{Crit},\;Q_R/Q_{Crit})$. The results suggest that $I_R/I_{Crit}$ in these parameters shows a good correlation with SP test results.

  • PDF

카드뮴에 의해 유도된 마우스의 고환 독성 모델에서 에너발란스의 보호 효과 (Protective Effect of Enerbalance on Cadmium-induced Testicular Damages in Mice)

  • 박광현;목지예;김성주;강형섭;심재석;장선일
    • 동의생리병리학회지
    • /
    • 제25권3호
    • /
    • pp.482-488
    • /
    • 2011
  • Cadmium (Cd) is well known as a spermatotoxic and gonadotoxic heavy metal ion. This study was performed to assess the possible protective effect of Enerbalance on Cd-induced spermiotoxicity and testicular damage. The control group received isotonic saline; Cd group received Cd (2 mg/kg BW per day) orally; extract-treated groups were orally administrated with Enerbalance (50 mg and 100 mg/kg BW per day) and Cd for 10 days. Morphological changes of testicular tissue, sperm characteristics, oxidative/antioxidative parameters from testis, and serum sexual hormone level were determined. Enerbalance was significantely increased sperm amount in cauda epididymis without changes of ratio of epididymis/body weight and testis/body weight. Cd caused a marked decrease in epididymal sperm concentration and chemotactic sperm motility, testicular superoxide dismutase (SOD), catalase (CAT), Enerbalance was significantly ameliorated loss of epididymal sperm concentration, sperm chemotactic motility, antioxidative parameters, and male hormone whereas decreased abnormal architecture by testis damage. Enerbalance was successfully attenuated these adverse effects of Cd and offers a dose-dependent protection. Our study demonstrated that Enerbalance could proffer a measure of protection against Cd-induced testicular damage and spermiotoxicity by possibly reducing oxidative stress and increasing the antioxidant defense mechanism in mice.

통행차량 특성을 반영한 강교량 피로설계트럭의 피로파괴 신뢰도해석 (Reliability Analysis of Fatigue Truck Model Using Measured Truck Traffic Statistics)

  • 신동구;권태형;박영석
    • 한국강구조학회 논문집
    • /
    • 제19권2호
    • /
    • pp.211-221
    • /
    • 2007
  • 교량의 피로파괴에 대한 Miner의 피로손상법칙을 적용하여 여러 확률변수로 표현된 피로파괴 한계상태함수에 대한 신뢰도해석을 국내에서 측정된 통행차량의 통계적 특성을 반영하여 수행하였다. 신뢰도지수의 산정에 필요한 확률변수 가운데 등가모멘트, 충격계수비, 등가하중비는 국내의 최근 측정자료를 분석하여 통계치를 산정하였으며, 피로강도, 활하중 횡분배비, 연행하중비는 국외에서 측정된 문헌자료의 통계치를 적용하였다. 신뢰도해석을 통하여 피로설계트럭의 종류, 교량수명, ADTT, 피로상세, 등가하중비, 피로설계트럭의 총중량 등의 피로손상에 관련된 여러 파라미터가 신뢰도지수에 미치는 영향을 분석하였다. 본 논문의 피로파괴에 대한 신뢰도해석 결과는 국내 LRFD 설계기준의 피로설계트럭모형과 피로한계상태의 하중계수를 결정할 때 기초 자료로 이용할 수 있을 것으로 판단된다.

Simultaneous identification of damage in bridge under moving mass by Adjoint variable method

  • Mirzaee, Akbar;Abbasnia, Reza;Shayanfar, Mohsenali
    • Smart Structures and Systems
    • /
    • 제21권4호
    • /
    • pp.449-467
    • /
    • 2018
  • In this paper, a theoretical and numerical study on bridge simultaneous damage detection procedure for identifying both the system parameters and input excitation mass, are presented. This method is called 'Adjoint Variable Method' which is an iterative gradient-based model updating method based on the dynamic response sensitivity. The main advantage of proposed method is inclusion of an analytical method to augment the accuracy and speed of the solution. Moving mass is a model which takes into account the inertia effects of the vehicle. This interaction model is a time varying system and proposed method is capable of detecting damage in this variable system. Robustness of proposed method is illustrated by correctly detection of the location and extension of predetermined single, multiple and random damages in all ranges of speed and mass ratio of moving vehicle. A comparison study of common sensitivity and proposed method confirms its efficiency and performance improvement in sensitivity-based damage detection methods. Various sources of errors including the effects of measurement noise and initial assumption error in stability of method are also discussed.

식이성요인이 SCE 빈도수로 본 흡연자의 DNA 손상에 미치는 영향 (Influence of Dietary Factors of Smokers on Smoking-Induced DNA Damage as Reflected by Sister Chromatid Exchanges(SCE))

  • 강명희
    • Journal of Nutrition and Health
    • /
    • 제27권7호
    • /
    • pp.740-751
    • /
    • 1994
  • Sister chromatid exchanges(SCE) in peripheral lymphocytes is recently used as a biomarker for increased cytogenetic damage in smokers. The purpose of the investigation was to determine if there were any relationships between dietary factors and their DNA damage as measured by SCE test in a group of 62 male cigarette smokers and 36 non-smokers. As expected, smokers as compared with non-smokers had high SCE levels (10.59$\pm$0.21 versus 9.23$\pm$0.17 SCE/lymphocytes ; p<0.05). No significant relationships were observed between SCEs and age in smokers and non-smokers. In smokers, SCEs were negatively correlated with egg frequency score(r=-0.336) and total food frequency scores(r=-0.283). In non-smokers, SCEs were positively correlated with white vegetable frequency score(r=0.333) and instant food frequency score(r=0.382). There was a positive association between SCEs and the history of coffee intake of smokers(r=0.318). SCE frequency was not influenced by any other dietary factors considered ; dietary diversity and quality scores, alcohol consumption, use of processed foods and intake of burned food. No significant relationships were found between SCEs and serum cholesterol or other hematological parameters of the subjects. These results indicate that increased egg frequency score, total food frequency score which reflects dietary quality, and decreased coffee intake may reduce cancer risk by preventing smoking-induced DNA damage as reflected by sister chromatid exchanges in human lymphocytes.

  • PDF