• 제목/요약/키워드: Damage curve

검색결과 550건 처리시간 0.027초

The development of the seismic fragility curves of existing bridges in Indonesia (Case study: DKI Jakarta)

  • Veby Citra Simanjuntak;Iswandi Imran;Muslinang Moestopo;Herlien D. Setio
    • Structural Monitoring and Maintenance
    • /
    • 제10권1호
    • /
    • pp.87-105
    • /
    • 2023
  • Seismic regulations have been updated from time to time to accommodate an increase in seismic hazards. Comparison of seismic fragility of the existing bridges in Indonesia from different historical periods since the era before 1990 will be the basis for seismic assessment of the bridge stock in Indonesia, most of which are located in earthquake-prone areas, especially those built many years ago with outdated regulations. In this study, seismic fragility curves were developed using incremental non-linear time history analysis and more holistically according to the actual strength of concrete and steel material in Indonesia to determine the uncertainty factor of structural capacity, βc. From the research that has been carried out, based on the current seismic load in SNI 2833:2016/Seismic Map 2017 (7% probability of exceedance in 75 years), the performance level of the bridge in the era before SNI 2833:2016 was Operational-Life Safety whereas the performance level of the bridge designed with SNI 2833:2016 was Elastic - Operational. The potential for more severe damage occurs in greater earthquake intensity. Collapse condition occurs at As = FPGA x PGA value of bridge Era I = 0.93 g; Era II = 1.03 g; Era III = 1.22 g; Era IV = 1.54 g. Furthermore, the fragility analysis was also developed with geometric variations in the same bridge class to see the effect of these variations on the fragility, which is the basis for making bridge risk maps in Indonesia.

강우량의 증가 경향성을 고려한 목표년도 확률강우량 산정 (Estimation of Design Rainfalls Considering an Increasing Trend in Rainfall Data)

  • 권영문;박진원;김태웅
    • 대한토목학회논문집
    • /
    • 제29권2B호
    • /
    • pp.131-139
    • /
    • 2009
  • 최근 우리나라에서 집중 호우의 발생이 잦아지고 강우 강도가 증가하면서 강우로 인한 극심한 홍수 피해가 빈번히 발생하고 있다. 홍수피해의 경감을 위해서 수공구조물의 계획 및 설계에서 강우의 증가경향을 반영한 목표년도 확률강우량 산정이 필요하다. 본 연구에서는 30년 이상 자료보유기간을 가진 기상청 관할 56개 강우관측소의 강우자료를 분석하여 증가 경향성이 존재하는 7개 지점의 설계목표년도의 확률강우량을 산정하는 방법을 제안하였다. Gumbel 분포를 이용하여 연 최대 강우량 평균과 위치 매개변수, 축척 매개변수 간 관계를 분석하였으며, 이를 바탕으로 설계목표년도에 적용가능한 확률밀도함수를 추정하고, 확률강우량을 산정하였다. 본 연구에서 제안된 방법으로 산정된 목표년도 확률강우량은 자료의 정상성을 가정한 확률강우량에 비해 6-20% 정도의 증가를 보여주고 있다.

LRB 면진장치가 설치된 엑스트라도즈드교의 지진위험도 평가 (Seismic Risk Assessment of Extradosed Bridges with Lead Rubber Bearings)

  • 김두기;서형렬;이진학
    • 대한토목학회논문집
    • /
    • 제26권1A호
    • /
    • pp.155-162
    • /
    • 2006
  • 본 연구에서는 납면진받침(LRB)이 설치된 중경간 엑스트라도즈드교에서 교각의 파손, 상부구조의 이동변위, 그리고 케이블의 항복에 대한 지진위험도를 평가하였다. 지진위험도는 다수의 지진자료를 이용하여 지진에 대한 구조적 취약성을 평가한 지진취약도와 지진재해지도를 이용하여 해당지역에서의 지진재해도를 산정하여, 이들을 조합함으로써 평가할 수 있었다. 지진시 교각에서 소성힌지의 발생을 고려하기 위해 SAP2000을 사용하여 비선형 지진해석을 수행하였다. 지진자료는 암반노두에서 설계응답스펙트럼을 만족하는 인공지진을 작성한 후, SHAKE91을 사용하여 해당지역의 지반증폭효과를 고려하여 지진 가속도 시간이력을 구하여 사용하였다. 교각의 비선형 응답은 연성도를 사용하여 나타내었고, 2선형 직선의 모멘트-곡률 곡선으로 작성하였다. 본 연구에서는 대수정규분포함수로 지진취약도를 표현하였으며, 한반도를 대상으로 작성된 지진재해지도를 이용하여 지진재해도를 산정하였다. 해석결과 엑스트라도즈드교에서는 케이블과 거더보다는 교각하단에서 면진장치가 더 효과적인 것을 알 수 있었다.

인공강우기 기반 확률강우재현을 통한 식생유니트형 LID시스템의 우수유출지연 효과분석 (Analysis of Rainfall Runoff Delay Effect of Vegetation Unit-type LID System through Rainfall Simulator-based Probable Rainfall Recreation)

  • 김태한;박정현;최부헌
    • 한국환경복원기술학회지
    • /
    • 제22권6호
    • /
    • pp.115-124
    • /
    • 2019
  • In a climate change environment where heat damage and drought occur during a rainy season such as in 2018, a vegetation-based LID system that enables disaster prevention as well as environment improvement is suggested in lieu of an installation-type LID system that is limited to the prevention of floods. However, the quantification of its performance as against construction cost is limited. This study aims to present an experiment environment and evaluation method on quantitative performance, which is required in order to disseminate the vegetation-based LID system. To this end, a 3rd quartile huff time distribution mass curve was generated for 20-year frequency, 60-minute probable rainfall of 68mm/hr in Cheonan, and effluent was analyzed by recreating artificial rainfall. In order to assess the reliability of the rainfall event simulator, 10 repeat tests were conducted at one-minute intervals for 20 minutes with minimum rainfall intensity of 22.29mm/hr and the maximum rainfall intensity of 140.69mm/hr from the calculated probable rainfall. Effective rainfall as against influent flow was 21.83mm/hr (sd=0.17~1.36, n=20) on average at the minimum rainfall intensity and 142.27mm/hr (sd=1.02~3.25, n=20) on average at the maximum rainfall intensity. In artificial rainfall recreation experiments repeated for three times, the most frequent quartile was found to be the third quartile, which is around 40 minutes after beginning the experiment. The peak flow was observed 70 minutes after beginning the experiment in the experiment zone and after 50 minutes in the control zone. While the control zone recorded the maximum runoff intensity of 2.26mm/min(sd=0.25) 50 minutes after beginning the experiment, the experiment zone recorded the maximum runoff intensity of 0.77mm/min (sd=0.15) 70 minutes after beginning the experiment, which is 20 minutes later than the control zone. Also, the maximum runoff intensity of the experiment zone was 79.6% lower than that of the control zone, which confirmed that vegetation unit-type LID system had rainfall runoff reduction and delay effects. Based on the above findings, the reliability of a lab-level rainfall simulator for monitoring the vegetation-based LID system was reviewed, and maximum runoff intensity reduction and runoff time delay were confirmed. As a result, the study presented a performance evaluation method that can be applied to the pre-design of the vegetation-based LID system for rainfall events on a location before construction.

치과 의료장비의 소음 수준 평가 (The Noise Level Assessment of Dental Equipment)

  • 이정숙;한예슬;조영식
    • 치위생과학회지
    • /
    • 제15권5호
    • /
    • pp.603-611
    • /
    • 2015
  • 치과 진료실에서 발생하는 소음원에 대한 소음의 특성을 파악하고 그에 따른 피해 가능성을 알아보기 위해 휴대용 소음기로 측정하여 검토한 결과 다음과 같은 결론을 얻었다. 치과용 의료기기 소음측정 결과 단독측정에서는 고속 핸드피스가 가장 높았으며, 초음파 스케일러, 저속 핸드피스 순서로 낮게 나타났다. 단독측정 시 평균 소음도는 58~66 dB(A)를 보였으며, 복합측정 시 평균 소음도는 62~71 dB(A)를 보였다. 진료실 형태에 따른 개방형과 개실형의 소음측정 결과 개방형 진료실에서의 소음이 평균 1.9~3.2 dB(A) 더 높게 나타났다. 비진료 시와 진료 시의 소음측정 결과 초음파 스케일러와 고속 핸드피스의 소음에서 통계적으로 유의한 차이가 있었다. 초음파 스케일러와 high volume aspirator을 함께 사용하였을 때 가장 높은 소음도를 보였으며, 진료 시 75.5 dB(A)로 비진료 시와 3.5 dB(A)의 소음차를 보이며 더 높게 나타났다. NR 곡선으로 진료 시 가장 높은 소음도를 보인 치석제거를 평가해본 결과 치석제거 시 NR-73~78로 ISO 소음기준중 일반작업장의 소음기준을 초과하는 수준이며 8 kHz의 고주파에서 피크치를 나타냈다. 진료 시 거리에 따른 소음을 측정한 결과 작업자와 가까운 30 cm 거리에서의 소음이 100 cm 거리에서의 소음보다 높은 패턴을 보였으며, 30 cm 거리에서 대상 치과 의료기기에서 발생하는 소음레벨은 79.8~80.6 dB(A)으로 장시간 폭로 시 청력 손실을 초래할 수 있는 수준이다. 두 거리의 차이로 5 dB(A) 이상의 소음 감쇠 효과를 확인하였다. 이상의 결과를 종합하여 볼 때 치과 치료 시 진료실 소음은 치과 의료기관 종사자에게 정신적, 육체적 피해를 줄 수 있는 정도이며, 본 연구결과를 통하여 얻어진 자료들이 기초가 되어 더 많은 치과 진료 시의 소음에 대한 특성이 파악된다면 직장환경의 질을 높이기 위한 체계적인 소음 감소 대책 수립이 가능할 것으로 생각된다.

무수치 표백시술시 치경부를 통한 표백제 누출량의 정량적 측정 (IN VITRO DETERMINATION & QUANTIFICATION OF HYDROGEN PEROXIDE PENETRATION DURING NONVITLAL BLEACHING)

  • 박수경;이정식;최한석
    • Restorative Dentistry and Endodontics
    • /
    • 제21권1호
    • /
    • pp.19-34
    • /
    • 1996
  • It has been demonstrated that intracoronal bleaching of pulpless teeth may result in cervical root resorption. Several authors postulated that bleaching agents such as hydrogen peroxide penetrated through the dentinal tubules to damage the surrounding tissues that cause cervical root resorption. The purpose of this study was to suggest on in vitro model for direct determination of hydrogen peroxide penetration through CEJ during nonvital bleaching. In addition, this model permit the quantification of the amount of hydrogen peroxide penetrated during the procedure. Freshly extracted intact premolars, removed for orthodontic reasons were used. Root canal treatment was performed in each tooth. And then the outer surface and crown portion of the teeth was sealed with wax leaving the CEJ. The prepared teeth mounted on the wax laminates were placed in plastic assay tubes containing 1.5ml bidistilled water with their entire root, including the CEJ, submerged in the solution. The teeth were dividied into four groups. Thermo group : thermocatalytic bleaching with superoxol Walk group: walking bleaching with sodium perborate & superoxol Combi group : combination of thermocatalytic & walking bleaching Dw group : walking bleaching with sodium perborate & water The bleaching procedure was performed three times. The bleaching intervals were at 3 days. The hydrogen peroxide present in the assay system was added to ferrous ammonium sulfate resulting in ferric ion release. Upon the addition of potassium thiocyanate a ferrithiocyanate complex results, which absorbs light at the wavelength of 467nm. The radicular penetration of hydrogen peroxide in the four groups was assessed directly using spectrophotometer. The amount of hydrogen peroxide in the samples tested is determined by comparing them with a standard curve generated by known amounts of hydrogen peroxide. The results were obtained as follows : 1. In all experimental groups except the Dw group showed lower penetration amount in day 4 than day 1, there was statistical importance in the difference (P<0.05). 2. After 3rd treatment, Thermo group showed slightly increased value and narrow distribution. Walk group showed much more penetration amount and widely dispersed value. Value of Combi group showed wide distribution without regard to treatment time, but value of Dw group evenly distributed. 3. Thermo group, Walk group and Dw group showed a tendency of increasing penetration amount with increasing treatment times(P<0.01), but Combi group revealed no statistically important differences. 4. Combi group showed the highest degree of penetration. Walk group showed lower penetration than Combi group. Thermo group & Dw group showed lower than Walk group. 5. Cervical root permeability to hydrogen peroxide varied from 0 to 35 %.

  • PDF

실측수문자료에 의한 Clark 모형의 매개변수 결정 (Determination of Parameters for the Clark Model based on Observed Hydrological Data)

  • 안태진;전현철;김민혁
    • 한국습지학회지
    • /
    • 제18권2호
    • /
    • pp.121-131
    • /
    • 2016
  • 타당한 설계홍수량의 결정은 하천관리에서 홍수에 의한 재해를 조절하는데 가장 중요한 사항이다. Clark 모형에서 집중시간과 저류상수는 첨두홍수량의 크기와 수문곡선의 형상에 영향을 미친다. 모형의 매개변수는 관측자료에 의해 보정되어야 하지만 관측자료의 부족으로 인하여 경험공식에 의하여 결정되고 있다. 본 연구는 안성천의 공도수위관측소 지점에서 실측수문자료에 의한 집중시간과 저류상수를 제시코자 하였다. 이를 위하여 관측치와 계산치의 평균제곱근오차 및 잔차를 산정하는 5개 기준을 제시하였다. 공도관측소지점에서 3개의 강우-유출사상으로부터 집중시간과 저류상수를 구하고 5개 기준에 의거 실측 수문곡선과 관측 수문곡선을 근거로 한 평균제곱근오차와 잔차를 산정하였다. 이를 통하여 관측수문자료와 Clark모형에 의한 결과를 근거로 집중시간과 저류상수를 결정하는 기준을 제시코자 하였다. 또한 도달시간-누가면적곡선식의 지수 값은 유역의 형상이 반영되는 값으로 결정하여야 함을 보여 주었다.

폭발 후 화재하중 시나리오에 따른 2방향 프리스트레스트 콘크리트 패널부재의 손상도 평가 (Damage Evaluation of Bi-directionally Prestressed Concrete Panels under Blast-fire Combined Loading)

  • 최지훈;최승재;김태균;김장호
    • 콘크리트학회논문집
    • /
    • 제29권3호
    • /
    • pp.237-248
    • /
    • 2017
  • 각종 사고 및 테러로 인한 폭발, 충돌, 화재 사고가 발생함에 따라 사회적인 안전 불감증이 더욱 고조되고 있으나, 실제 극한하중에 대한 구조물의 방호 설계가 반영되지 못하고 있는 실정이다. 특히, 원전격납구조물, 가스탱크 등과 같은 주요 시설물에 적용되고 있는 2방향 프리스트레스트 콘크리트(PSC) 구조물에 대한 폭발, 그리고 폭발로 인한 2차적으로 발생 가능한 화재에 대한 연구가 미흡함에 따라 복합손상 시나리오에 대한 구조물의 검토가 필요하다. 따라서, 본 연구에서는 폭발 후 화재하중 복합손상을 분석하기 위하여 $1,400mm{\times}1,000mm{\times}300mm$의 2방향 비부착 프리스트레스트 콘크리트를 제작하여, 폭발하중은 ANFO 25 kg의 장약량을 1.0 m 이격거리로 실험을 구성하고, 화재하중은 5분 이내에 $1,200^{\circ}C$의 화재하중을 가할 수 있는 RABT 화재시나리오를 적용하여 극한저항성능을 검토하였다. 본 연구는 향후 국내외 프리스트레스트 콘크리트에 대한 방호설계 및 폭발해석 등 관련 연구분야의 중요한 자료가 될 것이라 판단된다.

SLS 3D 프린터를 이용하여 제작된 PA2200의 단축 반복 인장하중에 따른 피로 특성에 관한 연구 (A study on the fatigue characteristics of SLS 3D printed PA2200 according to uniaxial cyclic tensile loading)

  • 박준수;정의철;최한솔;김미애;윤언경;김용대;원시태;이성희
    • Design & Manufacturing
    • /
    • 제14권1호
    • /
    • pp.49-55
    • /
    • 2020
  • In this study, the fatigue behavior and fatigue life characteristics of PA2200 specimens fabricated by SLS 3D printer were studied. Fatigue tests were performed according to the standard specification (ASTM E468) and fatigue life curves were obtained. In order to perform the fatigue test, mechanical properties were measured according to the test speed of the simple tensile test, and the self-heating temperature of the specimen according to the test speed was measured using an infrared temperature measuring camera in consideration of heat generation due to plastic deformation. There was no significant difference within the set test speed range and the average self-heating temperature was measured at 38.5 ℃. The mechanical strength at the measured temperature showed a relatively small difference from the mechanical strength at room temperature. Fatigue test conditions were established through the preceding experiments, and the loading conditions below the tensile strength at room temperature 23 ℃ were set as the cyclic load. The maximum number of replicates was less than 100,000 cycles, and the fracture behavior of the specimens with the repeated loads showed the characteristics of Racheting. It was confirmed that SLS 3D printing PA2200 material could be applied to the Basquin's S-N diagram for the fatigue life curve of metal materials. SEM images of the fracture surface was obtained to analyze the relationship between the characteristics of the fracture surface and the number of repetitions until failure. Brittle fracture, crazing fracture, grain melting, and porous fracture surface were observed. It was shown that the larger the area of crazing damage, the longer the number of repetitions until fracture.

정전위법에 의한 해상풍력 타워 구조물용 강재의 음극방식을 위한 최적방식전위 결정 (Determination of optimum protection potential for cathodic protection of offshore wind-turbine-tower steel substructure by using potentiostatic method)

  • 이정형;정광후;박재철;김성종
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제41권3호
    • /
    • pp.230-237
    • /
    • 2017
  • 본 연구에서는 해상풍력 타워 지지구조물용 강재인 S355ML 강에 대하여 전기화학적 기법으로 전기방식 설계에 필요한 최적 방식전위를 규명하고자 하였다. 동전위분극 실험 결과, 양극분극 곡선 상에서는 부동태 구간은 존재하지 않으며, 음극분극 곡선 상에는 용존산소환원반응에 의한 농도분극 구간과 수소가스 발생에 의한 활성화분극 구간이 관찰되었다. 음극방식 시 방식전위에 해당하는 농도분극 구간은 약 - 0.72 V ~ - 1.0 V의 전위 구간인 것으로 확인되었다. 다양한 전위에서 정전위 실험을 실시한 결과 전류밀도 변화는 시간에 따라 안정화되는 경향을 나타냈다. 1200초 동안 정전위 실험 후 주사전자현미경과 3D 분석 현미경을 이용한 시험편 표면 분석 결과, 양극분극 전위에 해당하는 0 V ~ - 0.50 V의 전위구간에서는 양극용해반응에 의한 부식손상이 관찰되었다. 이에 반해 음극분극 전위 영역에서는 대체적으로 손상이 없는 양호한 표면을 유지하였으며 석회질 피막 형성을 확인할 수 있었다. 연구결과, 농도분극 영역에 해당하는 - 0.8 V ~ - 1.0 V의 전위영역이 S355ML 강의 외부전원법에 의한 음극방식 적용 시 최적 방식 전위 구간으로 사료된다.