• Title/Summary/Keyword: Daejeon hardware correlator

Search Result 5, Processing Time 0.024 seconds

A STUDY ON THE RELIABILITY OF THE DAEJEON HARDWARE CORRELATOR FOR THE KVN OBSERVATION MODES (KVN 관측모드별 대전상관기의 상관결과 고찰)

  • OH, SE-JIN;ROH, DUK-GYOO;YEOM, JAE-HWAN;OH, CHUNG-SIK;LEE, SANG-SUNG;JUNG, DONG-KYU;KIM, HYO-RYOUNG;CHUNG, HYUN-SOO
    • Publications of The Korean Astronomical Society
    • /
    • v.31 no.2
    • /
    • pp.11-19
    • /
    • 2016
  • This paper presents the results of test observations toward a point source, 4C39.25, for observation modes with various bandwidths and numbers of IF streams in order to examine a reliability of the Daejeon hardware correlator performance for correlating VLBI (Very Long Baseline Interferometry) data obtained with the several observation modes of the KVN (Korean VLBI Network). We used a DiFX software correlator (DiFX) as a reference, for investigating the output visibilities from the Daejeon corelator. It is found that the band shapes of the output visibilities from two correlators are similar to each other and the correlated flux density for each baseline obtained from the Daejeon hardware correlator is lower by 3 - 7% than that from the DiFX. The flux difference is attributed to the limitation of FPGA resources and the difference of fringe rotation algorithm of the Daejeon hardware correlator. The conversion factor, 0.93 ~ 0.97, is proposed for future correlation with the Daejeon hardware correlator.

A NEW HARDWARE CORRELATOR IN KOREA: PERFORMANCE EVALUATION USING KVN OBSERVATIONS

  • Lee, Sang-Sung;Oh, Chung Sik;Roh, Duk-Gyoo;Oh, Se-Jin;Kim, Jongsoo;Yeom, Jae-Hwan;Kim, Hyo Ryoung;Jung, Dong-Gyu;Byun, Do-Young;Jung, Taehyun;Kawaguchi, Noriyuki;Shibata, Katsunori M.;Wajima, Kiyoaki
    • Journal of The Korean Astronomical Society
    • /
    • v.48 no.2
    • /
    • pp.125-137
    • /
    • 2015
  • We report results of the performance evaluation of a new hardware correlator in Korea, the Daejeon correlator, developed by the Korea Astronomy and Space Science Institute (KASI) and the National Astronomical Observatory of Japan (NAOJ). We conduct Very Long Baseline Interferometry (VLBI) observations at 22 GHz with the Korean VLBI Network (KVN) in Korea and the VLBI Exploration of Radio Astrometry (VERA) in Japan, and correlated the aquired data with the Daejeon correlator. For evaluating the performance of the new hardware correlator, we compare the correlation outputs from the Daejeon correlator for KVN observations with those from a software correlator, the Distributed FX (DiFX). We investigate the correlated flux densities and brightness distributions of extragalactic compact radio sources. The comparison of the two correlator outputs shows that they are consistent with each other within < 8%, which is comparable with the amplitude calibration uncertainties of KVN observations at 22 GHz. We also find that the 8% difference in flux density is caused mainly by (a) the difference in the way of fringe phase tracking between the DiFX software correlator and the Daejeon hardware correlator, and (b) an unusual pattern (a double-layer pattern) of the amplitude correlation output from the Daejeon correlator. The visibility amplitude loss by the double-layer pattern is as small as 3%. We conclude that the new hardware correlator produces reasonable correlation outputs for continuum observations, which are consistent with the outputs from the DiFX software correlator.

A Study on the Test Results and Implementation of Correlated Result Saving System using the Gluster File System (Gluster 파일시스템을 이용한 상관자료 수집 시스템 구축 및 시험고찰)

  • Yeom, Jae-Hwan;Oh, Se-Jin;Roh, Duk-Gyoo;Jung, Dong-Kyu;Hwang, Ju-Yeon;Oh, Chungsik;Kim, Hyo-Ryoung
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.17 no.2
    • /
    • pp.53-60
    • /
    • 2016
  • In this paper, we introduce the implementation and test results of a new method of correlated result storage to achieve the full performance of the Daejeon hardware correlator. Recently, the observation of 8 Gbps speed, which is the maximum observational standard of KVN(Korean VLBI Network), has been performed. The correlation processing using the Daejeon hardware correlator is also required. Therefore, a new correlation result storage introduction has become necessary. The maximum correlation result output speed of the Daejeon hardware correlator is 1.4 GB/sec per 25.6 ms integration time. The conventional correlation result storage system can not cope with the maximum correlation output speed of the Daejeon hardware correlator, and the output speed is limited to 1/4. That is, among the four input ports of the Daejeon hardware correlator, the three inputs are limited to correspond to the observation rate of 1 Gbps. This new storage system uses the Gluster file system among many of the latest technologies used in storage systems. In tests that meet the maximum output rate of 1.4 GB/sec for the Daejeon hardware correlator, 350 MB/sec for each of the four optical outputs, resulting in 1.4 GB/sec in total.

Amplitude Correction Factors of KVN Observations Correlated by DiFX and Daejeon Correlators

  • Lee, Sang-Sung
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.40 no.1
    • /
    • pp.54.1-54.1
    • /
    • 2015
  • We report results of investigation of amplitude calibration for very long baseline interferometry (VLBI) observations with Korean VLBI Network (KVN). Amplitude correction factors are estimated based on comparison of KVN observations at 22 GHz correlated by Daejeon hardware correlator and DiFX software correlator in Korea Astronomy and Space Science Institue (KASI) with Very Long Baseline Array (VLBA) observations at 22 GHz by DiFX software correlator in National Radio Astronomy Observatory (NRAO). We used the observations for compact radio sources, 3C 454.3 and NRAO 512 which are almost unresolved for baselines in a range of 350-477 km. VLBA visibility data of the sources observed with similar baselines as KVN are selected, fringe-fitted, calibrated, and compared in their amplitudes. We found that visibility amplitudes of KVN observations should be corrected by factors of 1.14 and 1.40 when correlated by DiFX and Daejeon correlators, respectively. These correction factors are attributed to the combination of two steps of 2-bit quantization in KVN observing systems and characteristics of Daejeon correlator.

  • PDF

AMPLITUDE CORRECTION FACTORS OF KOREAN VLBI NETWORK OBSERVATIONS

  • LEE, SANG-SUNG;BYUN, DO-YOUNG;OH, CHUNG SIK;KIM, HYO RYOUNG;KIM, JONGSOO;JUNG, TAEHYUN;OH, SE-JIN;ROH, DUK-GYOO;JUNG, DONG-KYU;YEOM, JAE-HWAN
    • Journal of The Korean Astronomical Society
    • /
    • v.48 no.5
    • /
    • pp.229-236
    • /
    • 2015
  • We report results of investigation of amplitude calibration for very long baseline interferometry (VLBI) observations with Korean VLBI Network (KVN). Amplitude correction factors are estimated based on comparison of KVN observations at 22 GHz correlated by Daejeon hardware correlator and DiFX software correlator in Korea Astronomy and Space Science Institute (KASI) with Very Long Baseline Array (VLBA) observations at 22 GHz by DiFX software correlator in National Radio Astronomy Observatory (NRAO). We used the observations for compact radio sources, 3C 454.3, NRAO 512, OJ 287, BL Lac, 3C 279, 1633+382, and 1510–089, which are almost unresolved for baselines in a range of 350-477 km. Visibility data of the sources obtained with similar baselines at KVN and VLBA are selected, fringe-fitted, calibrated, and compared for their amplitudes. We find that visibility amplitudes of KVN observations should be corrected by factors of 1.10 and 1.35 when correlated by DiFX and Daejeon correlators, respectively. These correction factors are attributed to the combination of two steps of 2-bit quantization in KVN observing systems and characteristics of Daejeon correlator.