• Title/Summary/Keyword: Daegu Metropolitan City

Search Result 431, Processing Time 0.027 seconds

Emission Characteristics of Odor Compounds from a Dyeing Wastewater Treatment Plant in an Industrial Complex Area in Daegu City (대구시 산업단지 염색폐수처리장의 악취발생 특성)

  • Lee, Chan-Hyung;Jeon, Hyun-Sook;Kwon, Byoung-Youne;Kim, Eun-Deok;Jang, Yun-Jae;Lee, Myeong-Sug;Keum, Jong-Lok;Song, Hee-Bong
    • Journal of Environmental Health Sciences
    • /
    • v.43 no.4
    • /
    • pp.314-323
    • /
    • 2017
  • Objectives: This study evaluated the odor emission characteristics from a wastewater treatment plant in an industrial complex area in Daegu City. Methods: Odor samples were collected from March 2016 to December 2016 and were analyzed for specified offensive odor substances. The odor quotient and the odor contribution was calculated. Results: Ammonia, hydrogen sulfide, acetaldehyde, and toluene were detected in all samples for monitoring specified odor compounds. The result of contribution analysis is that hydrogen sulfide had the highest contribution in all processes, followed by acetaldehyde. Conclusion: The major components of odor can be determined by evaluating the degree of contribution to the odor intensity and the concentration of the individual odor component. To increase the effectiveness of odor reduction, rather than addressing high-concentration odor compounds, policies focused on materials with a high odor contribution are necessary.

Emission Characteristics of Odor Compounds from a Sewage Treatment Plant Near an Industrial Complex Area in Daegu City (대구시 산업단지 인근 하수처리장의 악취발생 특성)

  • Lee, Myeong-Sug;Kang, Dong-Hoon;Keum, Jong-Lok;Kwon, Byoung-Youne;Jo, Hang-Wook;Lee, Chan-Hyung;Kim, Eun-Deok;Lim, Ho-Jin;Song, Hee-Bong
    • Journal of Environmental Health Sciences
    • /
    • v.44 no.2
    • /
    • pp.178-187
    • /
    • 2018
  • Objectives: This study evaluated the odor emission characteristics from a sewage treatment plant near an industrial complex area in Daegu City. Methods: Odor samples were collected from March 2017 to December 2017 and analyzed for specified offensive odor substances. The odor quotient and the odor contribution were calculated. Results: Ammonia, methyl mercaptane, hydrogen sulfide, dimethyl sulfide, acetaldehyde, propionylaldehyde, toluene, xylene, and methylethylketone were detected in all samples for monitoring the specified odor compounds. The result of contribution analysis is that hydrogen sulfide made the highest contribution in all processes, followed by acetaldehyde. Conclusion: The major components of odor can be determined by evaluating their degree of contribution to the odor intensity and the concentration of the individual odor component. To increase the effectiveness of odor reduction, rather than addressing high-concentration odor compounds, policies focused on materials with a high odor contribution are necessary.

Analysis of antimicrobial residues in meat samples from slaughtered livestock in 2006 (2006년 도축장 출하 지육에 대한 항생물질 잔류현황 분석)

  • Suh, Dong-Kyun;Park, Dae-Hyun;Hong, Ju-Yeon;Lim, Hyun-Sook;Kim, Kyung-Hee;Lee, Chun-Sik
    • Korean Journal of Veterinary Service
    • /
    • v.31 no.1
    • /
    • pp.129-135
    • /
    • 2008
  • A total of 3,943 samples (beef 698, pork 2,178 and chicken 1,067)were collected from slaughter houses in Daegu from January to December 2006 for analysis of antimicrobial residues. The results were also comparatively analyzed with those carried out from 16 veterinary service laboratories nationwide as a part of national residue program in 2006. The samples from 11 farms (cattle 2, pig 9) were found to exceed the legal limit. Among them 5 were classified as tetracyclines, 3 as $\beta$-lactams, 2 as sulfonamides and 1 as quinolone. Nationally a total of 222 farms (241 cases) were found to violate the residual limits, of which 47.3% were detected by screening test, followed by surveillance (38.3%). Failure to observe withholding periods of antimicrobial drugs after treatment was the most significant cause of the non-compliance.

Emission Characteristics of Odor Compounds from Fundamental Environmental Facilities in an Industrial Complex Area in Daegu City (대구시 산업단지 환경기초시설의 악취발생 특성)

  • Lee, Chan-Hyung;Jeon, Hyun-Sook;Shin, Myung-Cheol;Kim, Eun-Deok;Jang, Yun-Jae;Kwon, Byoung-Youne;Song, Hee-Bong
    • Journal of Environmental Health Sciences
    • /
    • v.42 no.4
    • /
    • pp.246-254
    • /
    • 2016
  • Objectives: This study evaluated the odor emission characteristics from fundamental environmental facilities at an industrial complex area in Daegu City. Methods: The odor samples were collected from May 2015 to January 2016 and were analyzed for specified offensive odor substances. The odor quotient and the odor contribution was calculated. Results: Ammonia was detected in all samples monitoring specified odor compounds, followed by hydrogen sulfide and acetaldehyde. According to contribution analysis, hydrogen sulfide shows the highest contribution in all facilities. At wastewater treatment plants A and B and sewage treatment plant F, it was followed by acetaldehyde. At wastewater treatment plant C, it was followed by imethyl sulfide. Conclusion: The major component of odor can be determined by evaluating the degree of contribution to the odor intensity rather than the concentration of the individual odor components. To increase the effectiveness of odor reduction, policies focused on materials with a high odor contribution are needed rather than focusing on high-concentration odor compounds.

Concentrations of SPM and Ambient Hazardous Heavy Metals in an Industrial Complex Area in Daegu City (대구시 산단지역 대기 중 SPM과 유해중금속성분의 농도)

  • Song, Hee-Bong;Kwon, Jong-Dae;Park, Su-Kyoung;Kim, Eun-Kyung;Yoon, Hyun-Suk;Ju, Myeong-Hui;Bae, Gi-Soo
    • Journal of Environmental Health Sciences
    • /
    • v.41 no.4
    • /
    • pp.259-267
    • /
    • 2015
  • Objectives: This study evaluated the regional and seasonal concentrations of ambient hazardous heavy metals in an industrial complex area in Daegu City. Methods: A total of 64 SPM (Suspended Particulate Matter) samples were collected in non-industrial and industrial areas during 2014 and were analyzed for hazardous heavy metals elements (As, Cd, Mn, Ni, Pb) with ICP after acid extraction. Results: SPM and hazardous heavy metals concentrations showed regional (industrial complex area>non-industrial complex area) and seasonal (spring, winter>fall, summer) variations. All of the hazardous heavy metals were influenced by anthropogenic sources. The pollution index of hazardous heavy metals was very low, showing roughly one-quarter of the level of the air quality guidelines of WHO. The correlation analysis among SPM and hazardous heavy metals indicated that components of non-industrial complex areas were more related to each other than those of industrial complex areas, and the correlation in the winter was higher than in other seasons. Conclusion: It is necessary to control air pollution sources and establish related policy because hazardous heavy metals from industrial areas can influence residential areas.

The Effect of Construction on Ambient PM-10 in the Surrounding Area - Focusing on the Field Case Research - (건설공사가 주변지역 대기 중의 PM-10에 미치는 영향 - 현장사례 연구를 중심으로 -)

  • Song, Hee-Bong;Kim, Eun-Kyung;Kwon, Jong-Dae;Park, Su-Kyoung;Yoon, Hyun-Suk;Ju, Myeong-Hui;Bae, Gi-Soo
    • Journal of Environmental Health Sciences
    • /
    • v.41 no.3
    • /
    • pp.163-170
    • /
    • 2015
  • Objectives: This study evaluated the effect of construction on ambient PM-10 in the surrounding area. Methods: Four study sites were selected from total AAQMN 11 points in Daegu city. All the four study sites were located near under or completed construction. Mean monthly PM-10 in 2007 to 2013 were analyzed. Results: Impact of residential construction on PM-10 was more obvious than industrial area. PM-10 was positively associated with number of construction near the study site. When there were 2 or 3 construction sites, PM-10 level was higher. Wind direction and the surrounding terrain affected PM-10. Conclusions: Construction has a strong influence on PM-10 in the surrounding Area. Reduce PM-10 there is the need for special construction site management. Proper management is required to minimize fugitive dust in construction sites.

Evaluation of the Odor around an Industrial Complex Area and the Operational Effects of the Odor Monitoring System in Seo-gu, Daegu City (대구시 서구 산업단지 주변 지역의 악취오염도와 악취감시시스템 운영 평가)

  • Lee, Myeong-Sug;Keum, Jong-Lok;Kang, Dong-Hoon;Jo, Hang-Wook;Kwon, Byoung-Youne;Kim, Eun-Deok;Lee, Chan-Hyung;Song, Hee-Bong;Shin, Sang-Hee
    • Journal of Environmental Health Sciences
    • /
    • v.47 no.1
    • /
    • pp.45-54
    • /
    • 2021
  • Objectives: This study evaluated the odor around an industrial complex area (#1-#5) and the operational effects of the Odor Monitoring System in Seo-gu in Daegu City. Methods: Samples were collected from November 2012 to December 2018 and were analyzed for complex odor. The odor occurrence rate and the odor reduction rate were calculated. Results: In 2018, the mean concentration of complex odor decreased 20.9% and the odor occurrence rate decreased from 65.0 to 27.5% around the industrial complex area (#1-#5) in Seo-gu compared to 2013. After the operation of the Odor Monitoring System, the standard excess rate (3.0%→40.8%) and the excess concentration of complex odor (1,442→4,304) increased at odor-emitting workplaces. In addition, the mean concentration of complex odor (15.9%) and the odor occurrence rate (60.6%→32.9%) around the industrial complex area (#1-#5) and the number of odor complaints (23.4%) in Seo-gu decreased. Conclusion: In order to reduce the odor around the industrial complex area, it is important to improve the odor emitting facilities. The Odor Monitoring System uses scientific and systematic monitoring methods that can help control and manage the odor emission facilities.

The Analysis of PM10 Concentration and the Evaluation of Influences by Meteorological Factors in Ambient Air of Daegu Area (대구지역 대기 중 미세먼지의 오염도 분석 및 기상인자에 따른 영향 평가)

  • Hwang, Yoon-Jung;Lee, Soon-Jin;Do, Hwa-Seok;Lee, Yun-Ki;Son, Tae-Jung;Kwon, Taek-Gyu;Han, Jung-Wook;Kang, Dong-Hun;Kim, Jong-Woo
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.25 no.5
    • /
    • pp.459-471
    • /
    • 2009
  • Air Monitoring Network(11 urban stations) is operated to measure ambient air quality in Daegu city. The urban air monitoring stations include 6 in residence area, 3 in industrial area, 1 in commercial area, and 1 in green area. In this study, hourly data (2006. 1. 1~2008. 12. 31) of $PM_{10}$ were measured at 11 urban air monitoring stations. $PM_{10}$ mean concentrations were high in fall and winter because of low wind speed and many haze days. The number of exceeding the daily standard of $PM_{10}$ in industrial area was approximately twice as many as that in residence area. $PM_{10}$ concentrations and visibility were influenced significantly by wind speed. Wind speed and visibility were below 1.8 m/s and 10 km, respectively when $PM_{10}$ concentrations were over $120{\mu}g/m^3$. $PM_{10}$ concentrations were high when haze was observed. The mean concentrations of $PM_{10}$ were $104{\pm}41.3{\mu}g/m^3$, $63{\pm}35.1{\mu}g/m^3$, and $49{\pm}26.9{\mu}g/m^3$, respectively when haze, mist and clear were observed.

The Concentrations of Ambient VOCs at Industrial Complex Area in Daegu City (대구시 산단지역 대기 중 휘발성유기화합물의 농도)

  • Kim, Eun-Kyung;Song, Hee-Bong;Park, Min-Sook;Lim, Jong-Ki;Kwon, Jong-Dae;Choi, Su-Jin;Park, Su-Kyung;Han, Gae-Hee
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.36 no.7
    • /
    • pp.498-505
    • /
    • 2014
  • This study was carried out to characterize the ambient VOCs concentrations of industrial complex in Daegu city. VOCs concentrations of industrial complex area appeared to be higher than those in the non-industrial complex area as following order toluene > ethylbenzene > m,p-xylenes > o-xylene but benzene and chloroform were similar to each other sites. There was seasonal variation of VOCs concentrations in the industrial complex area, higher in summer and lower in winter. In particular the industrial complex area shows that higher on weekday than weekend and higher in the daytime than in the morning or nighttime because industrial complex area influenced by the chemicals. Correlation coefficients among VOCs were confirmed that VOCs of industrial complex area were more related to each other than those of non-industrial complex area and VOCs concentrations have shown generally negative correlation with wind speed.