Evaluation of Flood Severity Using Bivariate Gumbel Mixed Model (이변량 Gumbel 혼합모형을 이용한 홍수심도 평가)

  • Lee, Jeong-Ho;Chung, Gun-Hui;Kim, Tae-Woong
    • Journal of Korea Water Resources Association
    • /
    • v.42 no.9
    • /
    • pp.725-736
    • /
    • 2009
  • A flood event can be defined by three characteristics; peak discharge, total flood volume, and flood duration, which are correlated each other. However, a conventional flood frequency analysis for the hydrological plan, design, and operation has focused on evaluating only the amount of peak discharge. The interpretation of this univariate flood frequency analysis has a limitation in describing the complex probability behavior of flood events. This study proposed a bivariate flood frequency analysis using a Gumbel mixed model for the flood evaluation. A time series of annual flood events was extracted from observations of inflow to the Soyang River Dam and the Daechung Dam, respectively. The joint probability distribution and return period were derived from the relationship between the amount of peak discharge and the total volume of flood runoff. The applicability of the Gumbel mixed model was tested by comparing the return periods acquired from the proposed bivariate analysis and the conventional univariate analysis.

A Study on Travelling Characteristics and Choice of Proper Location of Dam Discharge Alarm Broadcasting (댐 방류 경보방송의 전달 특성 및 적정 위치 선정에 관한 연구)

  • Kim, Dae-Goon;Kim, Jae-Soo
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.31 no.8
    • /
    • pp.635-640
    • /
    • 2009
  • After 1960s, in accordance with getting bigger in changing range of annual rain precipitation, those dams were built in order to prevent any drought and flood through the regulation of flux. In case of such dam, when it reaches to some definite pondage, for its regulation of water volume, numerous volume of water in the reservoir should be discharged by opening the floodgate, at this time a severe damage can be occurred to those lives and properties of the residents and tourists at the river or riverside. Accordingly, despite the sounding alarm broadcasting for prevention and notice such damage could be clearly travelled to those people without influence by the discharging noise or other neighboring environmental factor, since it was only empirically installed without any peculiar research until now, the alarm broadcasting could not effectively travel, and the travelling distance also could not known correctly. On such point of view, this Study has ever grasped the characteristics by frequencies and its sound pressure level about the discharge noise and the alarm broadcasting of Daechung Dam, one of multipurpose dams through the measurement and analysis by distances, and based on this, also has ever presupposed the proper location of additional alarm broadcasting spot using a simulation program named Cadna-A.

Performance Characteristics of Water-to-Air Heat Pump under Partial Load Heating Operation (물-공기 히트펌프 시스템의 부분부하 난방운전 특성)

  • Cho, Yong;Lee, Nam Young;Kim, Yong Yeol;Kim, Dea Geun;Jung, Eung Tai
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.06a
    • /
    • pp.170.1-170.1
    • /
    • 2010
  • Performance of water-to-air heat pump using raw water has been analyzed under part load heating operation in March, 2010. The water source heat pump of 30 RT was installed for 24 hours cooling and heating ventilation, and the gravity inflow water from Daechung dam is used as the heat source. The daily averaged water and air temperatures are $5.7^{\circ}C$ and $9.9^{\circ}C$ respectively, and the heat pump is operated under part load condition for 7.5 hours in 24 hours. The daily averaged heat pump COP calculated with heat transferred from the brine water is 2.49 and the monthly averaged COP is 2.25 in March. Based on the database of the California Energy Commission, the monthly averaged COPs of air source heat pumps installed in U.S.A. are 1.97 in March and 2.03 in April. Therefore it is confirmed again that the performance of the heat pump using raw water is better than that of air source heat pumps.

  • PDF

Evaluation of Water Quality in the Keum River using Statistics Analysis (통계분석 기법을 이용한 錦江水系의 水質評價)

  • Kim, Jong-Gu
    • Journal of Environmental Science International
    • /
    • v.11 no.12
    • /
    • pp.1281-1289
    • /
    • 2002
  • This study was conducted to evaluate water quality in the Keum River using multivariate analysis. The analysis data in Keum river made use of surveyed data by the ministry of environment from January 1994 to December 2001. Thirteen water quality parameter were determined on each sample. The results was summarized as follow; Water quality in the Keum River could be explained up to 71.39% by four factors which were included in loading of organic matter and nutrients by the tributaries (32.88%), seasonal variation (16.09%), loading of pathogenic bacteria by domestic sewage of Gapcheon (13.39%) and internal metabolism in estuary as lakes(9.03%). For spatial variation of factor score, four group was classified by each factor characterization. Station 1 and 2 was influenced by Daechung dam, station 3 was affected by domestic sewage of Gapcheon, station 10~12 was affected by estuary dyke and the rest station. The result of cluster analysis by station was classified into four group that has different water quality characteristics. In monthly cluster analysis, three group was classified according to seasonal characteristic. Also, in yearly cluster analysis, three group was classified. It is necessary to control the pollutant loadings by Gapcheon inflow domestic sewage in Daejeon city for the sake of water quality management of Keum river.

Development and Site Evaluation of the On-line Partial Discharge Measuring System on the 13 kV Class Stator Windings for Hydro Generator (13 kV급 수력발전기 고정자 권선용 On-line 부분방전 측정 시스템 개발 및 현장적용 평가)

  • Sun, Jong-Ho;Hwang, Don-Ha;Yun, Young-Ho;Shin, Byoung-Chol;Oh, Bong-Keun;Kang, Dong-Sik
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.55 no.4
    • /
    • pp.189-198
    • /
    • 2006
  • In order to improve the reliability of stator windings for hydro generators, it is necessary to detect the defective point and life assessment of the high voltage windings. Especially the on-line partial discharge (PD) test provides the ability to monitor effects, such as slot discharge, internal discharge, and end-winding discharge without interrupting generators, this method has been proven the major testing technology in high voltage rotating machines nowadays. The purpose of this paper is to describe the method of the on-line PD measurement on stator windings for hydro-generator with 13 [kV] class ceramic coupler (CC), on-line PD measuring system, terminal box, and index parameters. Also, the developed PD measuring system and 13 [kV] class CC were installed Daechung-dam generator #2. It was found that this installed sensor and system had good electrical characteristics to detect PD activity during the operating condition with its detection frequency band is between several and several tens MHz.

Development of a Stream Discharge Estimation Program (자연하천 유량산정 프로그램 개발)

  • Lee Sang Jin;Hwang Man Ha;Lee Bae Sung;Ko Ick Hwan
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.48 no.1
    • /
    • pp.27-38
    • /
    • 2006
  • In this study, we developed a program to estimate discharge efficiently considering major hydraulic characteristic including water level, river bed, water slope and roughness coefficient in a natural river. Stream discharge was measured at Gongju gauge station located in the down stream of the Daechung Dam during normal and dry seasons from 2003 to 2004. The developed model was compared with the results from the existing rating curve at T/M gage stations, and was used for runoff analyses. Evaluating the developed river discharge estimation program, it was applied during 1983-2004 that base flow separation method and RRFS (Rainfall Runoff Forecasting System) which is based on SSARR (Streamflow Synthesis And Resevoir Regulation). The result presents the stage-discharge curve creator range at the Gong-ju is overestimated by approximately $10-20\%$, especially at the low stage. It is attributed to the hydraulic characteristics at the study. The discharge simulated by the RRFS and base flow separation, which is calibrated using the measurement at the early spring and late fall season during relatively d]v season, shows the least errors. The coefficient of roughness at Gongju station varied with the high and low water level.

Short-Term Nutrient Enrichment Bioassays and Nutrient Limitation in Daechung Reservoir (대청호에서의 단기 영양염 첨가 실험 및 제한 영양염류 분석)

  • Lee, Sang-Jae;An, Kwang-Guk
    • Korean Journal of Ecology and Environment
    • /
    • v.43 no.1
    • /
    • pp.136-141
    • /
    • 2010
  • In situ experiments of Nutrient Enrichment Bioassays (NEBs) were conducted in the field along with in the laboratory to determine which nutrient limited phytoplankton growth as a indicator of primary productivity. For the NEBs, the water was sampled using a polyethylene-lined container and dispensed into 6 L water tank in the laboratory. The control (C, no nutrient spike) and six treatments of phosphorus (P), 2-fold phosphorus (2P), 4-fold phosphorus (4P), nitrate nitrogen ($NO_3$-N), 2-fold nitrate nitrogen ($2NO_3$-N), and phosphorus and nitrate nitrogen (P+$NO_3$-N) were set up in the lacustrine zone near the dam site, Daechung Reservoir in September, 2009 and analyzed the diel changes of total nitrogen (TN), total phosphorus (TP), and chlorophyll-$\alpha$ (Chl-$\alpha$) in the cubitainers. The short-term NEBs showed that algal response in the treatments spiked phosphorus (P, 2P, and 4P) were significantly (p < 0.05) greater than the response in the control (C), and nitrogen-spike. Also, the response in 4P-treatment was greater than those in the P- and 2P-treatments. In contrast, there was no significant differences (p > 0.20) between the $NO_3$-N and $2NO_3$-N treatment. The outcomes of the NEBs suggest that phosphorus limited the phytoplankton growth and nitrogen was not limited in this system. Furthermore, in the N + P treatments, the response was minimum, compared to all other treatments and the control, indicating that even if the system is evidently P-limited system, when added the nitrogen, the response showed the inhibition. Also, > 95% of observed long-term TN:TP ratios in the ambient water showed > 17, which is the criteria of P-limitation, supporting the P-limitation in the system. Overall, these results suggest that phytoplankton biomass near the dam is a direct linear function of P-loading near the watershed, if the phosphorus pool is mainly dissolved fraction.

Interannual and Seasonal Fluctuations of Nutrients, Suspended Solids, Chlorophyll, and Trophic Sate along with Other General Water Quality Parameters Near Two Intake Towers of Daechung Dam

  • Lee, Sun-Goo;Han, Jeong-Ho;Lee, Jae-Hoon;An, Kwang-Guk
    • Korean Journal of Ecology and Environment
    • /
    • v.43 no.4
    • /
    • pp.492-502
    • /
    • 2010
  • The study objects were to analyze long-term and seasonal variations of nutrients (N, P), suspended solids, N:P ratios, algal chlorophyll, and trophic state along with general water quality parameters in four sampling sites including two intake tower sites supplying drinking water in Daechung Reservoir. For the analysis, we used water quality long-term data sampled during 1998~2007 by the Ministry of Environment, Korea. Interannual and seasonal trends in inflow and discharge near the intake tower facilities over the ten years were directly influenced by rainfall pattern. The distinct difference between wet year (2003) and dry year (2001) produced marked differences in water temperature, pH, dissolved oxygen, organic matter contents, nutrients, and these variables influenced algal biomass and trophic state. Values of TP varied depending on the year and locations sampled, but monthly mean TP always peaked during July~August when river inflow and precipitation were maxima. In contrast, TN varied little compared to TP, indicating lower influence by seasonal flow compared to phosphorus. The number of E. coli were highest in Site 2 (Chudong intake tower) and varied largely, whereas at other sites, the numbers were low and low variations. Contents of chlorophyll-${\alpha}$ (CHL), as an estimation of primary productivity, varied largely depending on the year and season. The maximum of CHL occurred at Muneu intake tower (S4) during 2006 when the precipitation and inflow were lowest. In contrast, another CHL peak was observed in Site 2 (Chudong intake tower) in 2006 when one of the largest typoons (Ewinia) occurred and river runoff were maximum. So the CHL maxima were associated with both wet year (high flow, high nutrient supply) and dry year (low flow, nutrient supply by littoral zone). Such conditions influenced trophic states, based on Trophic State Index of nutrients and CHL. Based on all analyses, we can provide some clues for management and protection strategies of two intake tower sites.

Effects of Climate Change on the Streamflow for the Daechung Dam Watershed (기후변화에 따른 대청댐 유역의 유출 영향 분석)

  • Kim, Ung-Tae;Lee, Dong-Ryul;Yoo, Chul-Sang
    • Journal of Korea Water Resources Association
    • /
    • v.37 no.4
    • /
    • pp.305-314
    • /
    • 2004
  • Climate change mainly due to the increase of green house gases cause different patterns of water cycle within the basin. However, it is common that current planning and management practices do not consider the effect of the climate change. So, this study evaluated the effect of climate change on the water circulation within the watershed. This study used several GCM simulations for the double $CO_2$condition for the generation of temperature and rainfall series using the Markov chain. Daily runoff series for 100 years were generated using a rainfall-runoff model. As results. annual temperature increase by +3.2 ∼+4.6$^{\circ}C$, annual precipitation change -7 ∼ +8 %, annual runoff change -14 ∼ +7 %, and potential evapotranspiration amount change +3 ∼+4 % for the change of 1 $^{\circ}C$ are found to be expected depending on GCM simulations. Even though the simulation results are very dependent on the GCM predictions considered, overall variability of runoff is expected to become higher than the current state.

Applicability of the DAWAST Model Considered Return flows (용수 수요를 고려한 DAWAST 모형의 적용성 평가)

  • Noh, Jae-Kyoung
    • Journal of Korea Water Resources Association
    • /
    • v.36 no.6
    • /
    • pp.1097-1107
    • /
    • 2003
  • The DAWAST model was originally developed to consider the variation of water storage in the unsaturated soil zone and it is a conceptual lumped model. Return flows from agricultural, domestic and industrial water were included to the original result of model simulation to calibrate model parameters of watershed runoff. Agricultural water demand was estimated only in paddy fields supposing that return flow responded at stream was originated from paddy fields. Domestic and industrial water demand was estimated by average daily water demand multiplied monthly variation coefficient. Daily inflow to the Daechung multipurpose dam was applied to verify the DAWAST model considered return flows. On annual average from 1983 to 2001, inflows were simulated to 652.5 mm with return flows considered, which was approached more closer to observed inflow of 667.3 mm, compared with case of 606.8 mm with return flows not considered.