• Title/Summary/Keyword: DWI

Search Result 259, Processing Time 0.022 seconds

Feasibility of Simultaneous Multislice Acceleration Technique in Diffusion-Weighted Magnetic Resonance Imaging of the Rectum

  • Jae Hyon Park;Nieun Seo;Joon Seok Lim;Jongmoon Hahm;Myeong-Jin Kim
    • Korean Journal of Radiology
    • /
    • v.21 no.1
    • /
    • pp.77-87
    • /
    • 2020
  • Objective: To assess the feasibility of simultaneous multislice-accelerated diffusion-weighted imaging (SMS-DWI) of the rectum in comparison with conventional DWI (C-DWI) in rectal cancer patients. Materials and Methods: This study included 65 patients with initially-diagnosed rectal cancer. All patients underwent C-DWI and SMS-DWI with acceleration factors of 2 and 3 (SMS2-DWI and SMS3-DWI, respectively) using a 3T scanner. Acquisition times of the three DWI sequences were measured. Image quality in the three DWI sequences was reviewed by two independent radiologists using a 4-point Likert scale and subsequently compared using the Friedman test. Apparent diffusion coefficient (ADC) values for rectal cancer and the normal rectal wall were compared among the three sequences using repeated measures analysis of variance. Results: Acquisition times using C-DWI, SMS2-DWI, and SMS3-DWI were 173 seconds, 107 seconds, (38.2% shorter than C-DWI), and 77 seconds (55.5% shorter than C-DWI), respectively. For all image quality parameters other than distortion (margin sharpness, artifact, lesion conspicuity, and overall image quality), C-DWI and SMS2-DWI yielded better results than did SMS3-DWI (Ps < 0.001), with no significant differences observed between C-DWI and SMS2-DWI (Ps ≥ 0.054). ADC values of rectal cancer (p = 0.943) and normal rectal wall (p = 0.360) were not significantly different among C-DWI, SMS2-DWI, and SMS3-DWI. Conclusion: SMS-DWI using an acceleration factor of 2 is feasible for rectal MRI resulting in substantial reductions in acquisition time while maintaining diagnostic image quality and similar ADC values to those of C-DWI.

The Evaluation of Imaging Quality Depending the Shift of the Central Axis in FOCUS DWI Investigation (Focus DWI 검사에서 중심축 이동에 따른 화질 평가)

  • Kim, Younghwa;Jeong, Moontaeg;Choi, Namgil
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.5
    • /
    • pp.631-636
    • /
    • 2018
  • The problem that the existing the magnetic resonance image (MRI) was prone to have not only long readout duration and low bandwidth in the phase-encode direction, but also geometric distortion was pointed out. The purpose of this study is to identify the usefulness of FOCUS-DWI through comparing FOCUS-DWI with the Conventional-DWI on a degree of uniformity and artifacts caused by the distance change in the central axis within the magnetic field. In terms of artifacts, there happened irregular striped artifacts in the Conventional-DWI technique, which in particular, more often arose in the central axis. Also, the overlap of imaging drastically increased. By contrast, there were no irregular striped artifacts in the FOCUS-DWI technique. In conclusion, it was found that the FOCUS-DWI technique was superior to the Conventional-DWI technique in terms of artifacts, the overlap of imaging, and a degree of uniformity. In addition, there was no difference of the change in distance from the central axis between the FOCUS-DWI technique and the Conventional-DWI technique. Thus, it is considered the FOCUS-DWI technique having less imaging distortion and high image quality will be highly clinically used.

Feasibility Study of Synthetic Diffusion-Weighted MRI in Patients with Breast Cancer in Comparison with Conventional Diffusion-Weighted MRI

  • Bo Hwa Choi;Hye Jin Baek;Ji Young Ha;Kyeong Hwa Ryu;Jin Il Moon;Sung Eun Park;Kyungsoo Bae;Kyung Nyeo Jeon;Eun Jung Jung
    • Korean Journal of Radiology
    • /
    • v.21 no.9
    • /
    • pp.1036-1044
    • /
    • 2020
  • Objective: To investigate the clinical feasibility of synthetic diffusion-weighted imaging (sDWI) at different b-values in patients with breast cancer by assessing the diagnostic image quality and the quantitative measurements compared with conventional diffusion-weighted imaging (cDWI). Materials and Methods: Fifty patients with breast cancer were assessed using cDWI at b-values of 800 and 1500 s/mm2 (cDWI800 and cDWI1500) and sDWI at b-values of 1000 and 1500 s/mm2 (sDWI1000 and sDWI1500). Qualitative analysis (normal glandular tissue suppression, overall image quality, and lesion conspicuity) was performed using a 4-point Likert-scale for all DWI sets and the cancer detection rate (CDR) was calculated. We also evaluated cancer-to-parenchyma contrast ratios for each DWI set in 45 patients with the lesion identified on any of the DWI sets. Statistical comparisons were performed using Friedman test, one-way analysis of variance, and Cochran's Q test. Results: All parameters of qualitative analysis, cancer-to-parenchyma contrast ratios, and CDR increased with increasing b-values, regardless of the type of imaging (synthetic or conventional) (p < 0.001). Additionally, sDWI1500 provided better lesion conspicuity than cDWI1500 (3.52 ± 0.92 vs. 3.39 ± 0.90, p < 0.05). Although cDWI1500 showed better normal glandular tissue suppression and overall image quality than sDWI1500 (3.66 ± 0.78 and 3.73 ± 0.62 vs. 3.32 ± 0.90 and 3.35 ± 0.81, respectively; p < 0.05), there was no significant difference in their CDR (90.0%). Cancer-to-parenchyma contrast ratios were greater in sDWI1500 than in cDWI1500 (0.63 ± 0.17 vs. 0.55 ± 0.18, p < 0.001). Conclusion: sDWI1500 can be feasible for evaluating breast cancers in clinical practice. It provides higher tumor conspicuity, better cancer-to-parenchyma contrast ratio, and comparable CDR when compared with cDWI1500.

Analysis of Effectiveness of Traffic Safety Education on DWI(Driving While Intoxicated) Deterrence (교통안전교육의 음주운전억제 효과분석)

  • Jeong, Cheol-U;Jang, Myeong-Sun
    • Journal of Korean Society of Transportation
    • /
    • v.29 no.3
    • /
    • pp.21-29
    • /
    • 2011
  • The purpose of this study is to analyze the deterrence effect of traffic safety education on DWI(Driving While Intoxicated) offenders which is proposed as a incentive policy measure. For the analysis, 3512 drivers whose licenses were suspended due to DWI offence within the jurisdiction of Seongnam city in 2003, and whose driving behavior were traced for 5 years are collected. MOEs used in the study are the number of repeated DWI offence and DWI abidance duration. The statistics of analysis of covariance are used to compare the deterrence effectiveness of traffic safety education by adjusted means between groups. The results show that compared to uneducated group, educated group reveals to make less number of repeated DWI offence with longer DWI abidance period The resulting statistic also shows that active participation in the discussion during the class is more effective than just giving lecture. The former way for education can further reduce the repeated DWI by 12% and increase DWI abidance duration by 5.7% than the latter.

Diffusion-Weighted Magnetic Resonance Imaging in the Diagnosis of Cerebral Venous Thrombosis : A Meta-Analysis

  • Lv, Bin;Jing, Feng;Tian, Cheng-lin;Liu, Jian-chao;Wang, Jun;Cao, Xiang-yu;Liu, Xin-feng;Yu, Sheng-yuan
    • Journal of Korean Neurosurgical Society
    • /
    • v.64 no.3
    • /
    • pp.418-426
    • /
    • 2021
  • Objective : A role of diffusion-weighted imaging (DWI) in the diagnosis of cerebral venous thrombosis (CVT) is not well-understood. This study evaluates the effectiveness of DWI in the diagnosis of CVT. Methods : Literature search was conducted in electronic databases for the identification of studies which reported the outcomes of patients subjected to DWI for CVT diagnosis. Random-effects meta-analyses were performed to achieve overall estimates of important diagnostic efficiency indices including hyperintense signal rate, the sensitivity and specificity of DWI in diagnosing CVT, and the apparent diffusion coefficient (ADC) of DWI signal areas and surrounding tissue. Results : Nineteen studies (443 patients with 856 CVTs; age 40 years [95% confidence interval (CI), 33 to 43]; 28% males [95% CI, 18 to 38]; symptom onset to DWI time 4.6 days [95% CI, 2.3 to 6.9]) were included. Hyperintense signals on DWI were detected in 40% (95% CI, 26 to 55) of the cases. The sensitivity of DWI for detecting CVT was 22% (95% CI, 11 to 34) but specificity was 98% (95% CI, 95 to 100). ADC values were quite heterogenous in DWI signal areas. However, generally the ADC values were lower in DWI signal areas than in surrounding normal areas (mean difference-0.33×10-3 ㎟/s [95% CI, -0.44 to -0.23]; p<0.00001). Conclusion : DWI has a low sensitivity in detecting CVT and thus has a high risk of missing many CVT cases. However, because of its high specificity, it may have supporting and exploratory roles in CVT diagnosis.

Quantitative and Qualitative Evaluation of Brain Diffusion Weighted Magnetic Resonance Imaging: Comparision with 1.5 T and 3.0 T Units (뇌 확산강조 자기공명영상에 대한 정량적, 성적 평가: 1.5 T와 3.0 T 기기 비교)

  • Goo, Eun-Hoe;Dong, Kyung-Rae
    • Journal of Radiation Industry
    • /
    • v.10 no.4
    • /
    • pp.227-230
    • /
    • 2016
  • DWI of biological effects are independent of magnetic field strength in various regions. High field strength, however, does affect the signal to noise ratio (SNR) and artifacts of diffusion weighted imaging (DWI) images, which ultimately will influence the quantitative of diffusion imaging. In this study, the effects of field strength on DWI are reviewed. The effects of the diseases also are discussed. Comparing DWI in cerebellum, WM, GM, Hyperacute region measurements both as a function of field strength (1.5T and 3.0T). Overall, the SNR of the DWI roughly doubled going from 1.5 T to 3.0 T. In summary, DWI studies at 3.0 T is provided significantly improved DWI measurements relative to studies at 1.5T.

Diffusion-weighted MR Imaging of Hypoxic-Ischemic Encephalopathy (저산소성-허혈성 뇌증의 확산강조영상 소견)

  • Choi, Hye-Young;Choi, Dae-Seob;Ryoo, Jae-Wook;Cho, Jae-Min;Ko, Eun-Sook;Shin, Tae-Beom;Na, Jae-Beom;Choi, Nak-Cheon
    • Investigative Magnetic Resonance Imaging
    • /
    • v.12 no.1
    • /
    • pp.49-54
    • /
    • 2008
  • Purpose : The purpose of this study was to determine the characteristics of hypoxic-ischemic encephalopathy (HIE) on diffusion-weighted imaging (DWI) and the role of DWI for the diagnosis of HIE. Materials and Methods : Six patients with HIE underwent MRI including DWI. MR examinations were performed within 4 - 32 days (mean, 11.8 days) after hypoxic brain insult. We assessed the distribution of the lesions and compared the DWI and T2, FLAIR images for the subjective conspicuity of the lesions. Results : In all patients, symmetrical hyperintense lesions were demonstrated in the bilateral basal ganglia on T2, FLAIR, and DWI. On ADC map image, the lesions were hypointense in four of six patients and isointense in other two patients. Lesion conspicuity on DWI was higher than on T2 and FLAIR images in four of six patients and similar in other two patients. For the involvement of the cortex and subcortical white matter, in five of six patients, bilateral symmetric hyperintense lesions were seen on T2, FLAIR, and DWI. Lesion conspicuity on DWI was higher than on T2 and FLAIR images in three of them and similar in other two patients. On ADC map image, the lesions showed hypointensity in three of five patients and isointensity in other two patients. For the involvement of the deep cerebral white matter, T2, FLAIR, and DWI showed bilateral symmetric hyperintense lesions in four of six patients. Among them, Lesion conspicuity on DWI was higher than on T2 and FLAIR images in only one patient. Conclusion : HIE is characterized by symmetrical hyperintense lesions in the bilateral basal ganglia, cerebral cortex, and white matter on DWI and the lesions are more conspicuously demonstrated on DWI than on T2 and FLAIR images.

  • PDF

Growth and Yield of Rice by Field Water Management for Water-Saving Irrigation (물절약형 담수심 관리방법에 따른 벼 생육 및 수량)

  • Choi Jang Soo;Won Jong Gun;Ahn Deok Jong;Park Sang Gu;Lee Seong Phill
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.49 no.6
    • /
    • pp.441-446
    • /
    • 2004
  • To reduce water input by water-saving irrigation techniques a field study was carried out with three water managements, very shallow intermittent irrigation (VSII, 2cm), shallow intermittent irrigation (SII, 4cm) and traditional deep water irrigation (DWI, 10cm) for two years. Rice growth and grain yields of three water managements were not significantly different. However, when the water irrigation depth was decreased, the breaking and lodging resistance were increased and the roots were widely distributed into deeper paddy soil. More numbers of both annual and perennial weeds were occurred in VSII than in DWI at maximum heading stage and only the number of perennial weeds was three times in VSII than in DWI at heading stage. The total water inputs were 777, 654 and 527 mm in DWI, SII and VSII, therefore the water-saving rates of VSII and SII were $32.2\%\;and\;15.9\%$ compared to typical deep water irrigation. The water-productivity (Rice yield to water input) was highest in VSII as 0.94 and followed by SII as 0.76 and DWI as 0.63. In the face of water scarcity, it is very important to find or develope water saving irrigation system and find ways to increase the productivity of water used for rice cultivation.

Thromboembolic Events Associated with Electrolytic Detachment of Guglielmi Detachable Coils and Target Coils : Comparison with Use of Diffusion-Weighted MR Imaging

  • Kim, Myeong Jin;Lim, Yong Cheol;Oh, Se-Yang;Kim, Byung Moon;Kim, Bum-Soo;Shin, Yong Sam
    • Journal of Korean Neurosurgical Society
    • /
    • v.54 no.1
    • /
    • pp.19-24
    • /
    • 2013
  • Objective : The purpose of this study was to retrospectively evaluate and compare the incidence of diffusion-weighted image (DWI) lesions between the Guglielmi detachable coil (GDC) and the Target coil for treating unruptured intracranial aneurysm. Methods : From 2010 to 2011, consecutive 222 patients with an intracranial aneurysm underwent coil embolization. Inclusion criterias were : 1) unruptured intracranial aneurysm, 2) one or more GDC or Target coils used with or without other coils, 3) DWI examination within 24 hours after coiling, and 4) coiling performed without a balloon or stent. Results : Ninety patients (92 cases) met the inclusion criteria. DWI lesions were detected in 55 (61.1%) of 90 patients. In the GDC group (n=44), DWI lesions were detected in 31 (70.5%). The average number of DWI lesions was $5.0{\pm}8.7$ (mean${\pm}$SD; range, 1-40) in aneurysm-related territory. In the Target coil group (n=48), DWI lesions were detected in 24 (50.0%). The number of DWI lesion was $2.1{\pm}5.4$ (range, 1-32) in aneurysm-related territory. There was no significant correlation between a number of coils and DWI lesions. No significant differences were also observed in the number of DWI lesions in each group. Conclusion : The GDC and Target coils, which have an electrolytic detachable system, showed no differences in the incidence of DWI lesion.

Diagnostic Yield of Diffusion-Weighted Brain Magnetic Resonance Imaging in Patients with Transient Global Amnesia: A Systematic Review and Meta-Analysis

  • Su Jin Lim;Minjae Kim;Chong Hyun Suh;Sang Yeong Kim;Woo Hyun Shim;Sang Joon Kim
    • Korean Journal of Radiology
    • /
    • v.22 no.10
    • /
    • pp.1680-1689
    • /
    • 2021
  • Objective: To investigate the diagnostic yield of diffusion-weighted imaging (DWI) in patients with transient global amnesia (TGA) and identify significant parameters affecting diagnostic yield. Materials and Methods: A systematic literature search of the MEDLINE and EMBASE databases was conducted to identify studies that assessed the diagnostic yield of DWI in patients with TGA. The pooled diagnostic yield of DWI in patients with TGA was calculated using the DerSimonian-Laird random-effects model. Subgroup analyses were also performed of slice thickness, magnetic field strength, and interval between symptom onset and DWI. Results: Twenty-two original articles (1732 patients) were included. The pooled incidence of right, left, and bilateral hippocampal lesions was 37% (95% confidence interval [CI], 30-44%), 42% (95% CI, 39-46%), and 25% (95% CI, 20-30%) of all lesions, respectively. The pooled diagnostic yield of DWI in patients with TGA was 39% (95% CI, 27-52%). The Higgins I2 statistic showed significant heterogeneity (I2 = 95%). DWI with a slice thickness ≤ 3 mm showed a higher diagnostic yield than DWI with a slice thickness > 3 mm (pooled diagnostic yield: 63% [95% CI, 53-72%] vs. 26% [95% CI, 16-40%], p < 0.01). DWI performed at an interval between 24 and 96 hours after symptom onset showed a higher diagnostic yield (68% [95% CI, 57-78%], p < 0.01) than DWI performed within 24 hours (16% [95% CI, 7-34%]) or later than 96 hours (15% [95% CI, 8-26%]). There was no difference in the diagnostic yield between DWI performed using 3T vs. 1.5T (pooled diagnostic yield, 31% [95% CI, 25-38%] vs. 24% [95% CI, 14-37%], p = 0.31). Conclusion: The pooled diagnostic yield of DWI in TGA patients was 39%. DWI obtained with a slice thickness ≤ 3 mm or an interval between symptom onset and DWI of > 24 to 96 hours could increase the diagnostic yield.