• Title/Summary/Keyword: DVP

Search Result 9, Processing Time 0.018 seconds

Compensation of the Error Rate for the Non-invasive Sphygmomanometer System Using a Tactile Sensor

  • Jeong, In-Cheol;Choi, Yoo-Nah;Yoon, Hyung-Ro
    • Journal of Electrical Engineering and Technology
    • /
    • v.2 no.1
    • /
    • pp.136-141
    • /
    • 2007
  • The Purpose Of This Paper Is To Use A Tactile Sensor To Compensate The Error Rate. Most Automated Sphygmomanometers Use The Oscillometric Method And Characteristic Ratio To Estimate Systolic And Diastolic Blood Pressure. However, Based On The Fact That Maximum Amplitude Of The Oscillometric Waveform And Characteristic Ratio Are Affected By Compliance Of The Aorta And Large Arteries, A Method To Measure The Artery Stiffness By Using A Tactile Sensor Was Chosen In Order To Integrate It With The Sphygmomanometer In The Future Instead Of Using Photoplethysmography. Since Tactile Sensors Have Very Weak Movements, Efforts Were Made To Maintain The Subject's Arm In A Fixed Position, And A 40hz Low Pass Filter Was Used To Eliminate Noise From The Power Source As Well As High Frequency Noise. An Analyzing Program Was Made To Get Time Delay Between The First And Second Peak Of The Averaged Digital Volume Pulse(${\Delta}t_{dvp}$), And The Subject's Height Was Divided By ${\Delta}t_{dvp}$ To Calculate The Stiffness Index Of The Arteries($Si_{dvp}$). Regression Equations Of Systolic And Diastolic Pressure Using $Si_{dvp}$ And Mean Arterial Pressure(Map) Were Computed From The Test Group (60 Subjects) Among A Total Of 121 Subjects(Age: $44.9{\pm}16.5$, Male: Female=40:81) And Were Tested In 61 Subjects To Compensate The Error Rate. Error Rates Considering All Subjects Were Systolic $4.62{\pm}9.39mmhg$, And Diastolic $14.40{\pm}9.62mmhg$, And Those In The Test Set Were $3.48{\pm}9.32mmhg,\;And\;14.34{\pm}9.67mmhg$ Each. Consequently, Error Rates Were Compensated Especially In Diastolic Pressure Using $Si_{dvp}$, Various Slopes From Digital Volume Pulse And Map To Systolic-$1.91{\pm}7.57mmhg$ And Diastolic $0.05{\pm}7.49mmhg$.

Inhibitory Effects of Lyophilized Dropwort Vinegar Powder on Adipocyte Differentiation and Inflammation (미나리 발효 식초의 지방세포 분화억제 및 항염증 효과)

  • Park, Yun-Hee;Choi, Jun-Hyeok;Whang, Key;Lee, Syng-Ook;Yang, Seun-Ah;Yu, Mi Hee
    • Journal of Life Science
    • /
    • v.24 no.5
    • /
    • pp.476-484
    • /
    • 2014
  • Obesity, which is characterized by a state of mild chronic inflammation, is known to cause metabolic diseases. This study was carried out to investigate the effect of lyophilized dropwort vinegar powder (DVP) on adipocyte differentiation and inflammation in T3-L1 preadipocyte and RAW 264.7 macrophage cell lines. DVP inhibited the differentiation of 3T3-L1 preadipocytes induced by a mixture of IBMX, dexamethasone, and insulin (MDI). Western blot analysis of cell lysates showed that DVP decreased the levels of two major transcription factors involved in adipogenesis, peroxisome proliferator- activated receptor-${\gamma}$ (PPAR-${\gamma}$) and CCAAT-enhancer-binding protein ${\alpha}$ ($C/EBP{\alpha}$). DVP also significantly suppressed lipopolysaccharide (LPS)-induced production of nitric oxide (NO), and this was accompanied by a decrease in inducible NO synthase (iNOS) and cyclooxygenase-2 (COX-2) protein expression. These results demonstrate that DVP inhibits MDI-induced adipocyte differentiation of 3T3-L1 cells and LPS-induced inflammation in RAW 264.7 macrophage cells. The findings indicate that this natural product may be a good candidate as to prevent metabolic diseases.

해외통상정보

  • Korea Electronics Association
    • Journal of Korean Electronics
    • /
    • v.14 no.6
    • /
    • pp.97-100
    • /
    • 1994
  • PDF

Quality Changes of Fresh-Cut Tumeric by Packaging Methods during Storage (포장방법에 따른 세절 생울금의 저장 중 품질 변화)

  • Kim, Dong-Hoo;Han, Jin-Soo;Woo, In-Bong;Jung, Jun-Jae;Park, Si-Woo;Heo, Kyung-Chel;Ha, Ju-hyeung;Yoon, Chan-Suk
    • KOREAN JOURNAL OF PACKAGING SCIENCE & TECHNOLOGY
    • /
    • v.23 no.3
    • /
    • pp.151-162
    • /
    • 2017
  • The purpose of this study was to investigate the quality change of fresh-cut tumeric (Curcuma Longa Linne) according to packaging method during storage time. The fresh-cut tumeric were packaged in three different methods : degassing valve packaging (DVP), $CO_2$ gas absorber packaging (CAP) and micro-perforated packaging (MPP). After the samples were packaged, they were stored for 15 days at 4 and $23^{\circ}C$ respectively. The following parameters were observed to indicate the quality changes of the samples: weight loss, CIE $L^*a^*b^*$ colour difference, variation of gas composition inside the package, curcumin contents and changes in hardness of fresh-cut tumeric. DVP did not effectively release $CO_2$ gas to the outside. MPP was suitable to release $CO_2$ gas. However, MPP showed very fast browning and erosion, because a large amount of oxygen was introduced through the perforated hole on the film. CAP was most effective packaging method to inhibit browning, to prevent expansion of the packaging by $CO_2$ gas and to minimize weight loss of fresh-cut tumeric.

The Characteristic Curves of Commercial Medical X-ray Films (상용 의학용 X-ray 필름의 특성곡선)

  • Heo, Hoon;Jeong, Yeon-Tae;Lee, Jae-Sung
    • Journal of the Korean Graphic Arts Communication Society
    • /
    • v.19 no.2
    • /
    • pp.12-21
    • /
    • 2001
  • For the purpose of determining characteristics of widely used commercial medical x-ray films, which are used for obtaining the Linac-grams for radiational treatment of cancers, we placed several commercial x-ray films at a fixed distance form the linear accelerator. After varying the exposed amount of radiation step by step, we could obtain a continually increasing density image for each film whose densities were determined by microdensitometer readings. The characteristic curves of the films were obtained by plotting the densities vs. the exposed radiation amounts, and their ${\gamma}$ values were determined. These values can be used to suggest a minimum necessary amount of exposed radiation to get a useful Linac-gram. The measured ${\gamma}$ values of the characteristic curves of the Kodak-DVP/RA-1 film were 1.73 when used 6MV x-ray, 1.70 when used 15MV of intensity. For the Konica-AX film, ${\gamma}$ values were 1.29 and 1.18 respectively. The result suggests that the effective conditions for high resolution of a L-gram be 6 MV of x-ray intensity and about 3 rad of exposed dose on a Kodak-DVP/RA-1 film.

  • PDF

Early Vertebroplasty versus Delayed Vertebroplasty for Acute Osteoporotic Compression Fracture : Are the Results of the Two Surgical Strategies the Same?

  • Son, Seong;Lee, Sang-Gu;Kim, Woo-Kyung;Park, Chan-Woo;Yoo, Chan-Jong
    • Journal of Korean Neurosurgical Society
    • /
    • v.56 no.3
    • /
    • pp.211-217
    • /
    • 2014
  • Objective : In Korea, early vertebroplasty (EVP) or delayed vertebroplasty (DVP, which is performed at least 2 weeks after diagnosis) were performed for the treatment of acute osteoporotic compression fracture (OCF) of the spine. The present study compared the outcomes of two surgical strategies for the treatment of single-level acute OCF in the thoracolumbar junction (T12-L2). Methods : From 2004 to 2010, 23 patients were allocated to the EVP group (EVPG) and 27 patients to the DVP group (DVPG). Overall mean age was $68.3{\pm}7.9$ and minimum follow-up period was 1.0 year. Retrospective study of clinical and radiological results was conducted. Results : No significant differences in baseline characteristics were observed between the two groups. As expected, mean duration from onset to vertebroplasty and mean duration of hospital stay were significantly longer in the DVPG ($17.1{\pm}2.1$ and $17.5{\pm}4.2$) than in the EVPG ($3.8{\pm}3.3$ and $10.8{\pm}5.1$, p=0.001). Final clinical outcome including visual analogue scale (VAS), Oswestry Disability Index, and Odom's criteria did not differ between the two groups. However, immediate improvement of the VAS after vertebroplasty was greater in the EVPG ($5.1{\pm}1.3$) than in the DVPG ($4.0{\pm}1.0$, p=0.002). The proportion of cement leakage was lower in the EVPG (30.4%) than in the DVPG (59.3%, p=0.039). In addition, semiquantitative grade of cement interdigitation was significantly more favorable in the EVPG than in the DVPG (p=0.003). Final vertebral body collapse and segmental kyphosis did not differ significantly between the two groups. Conclusion : Our findings suggest that EVP achieves a better immediate surgical effect with more favorable cost-effectiveness.

High-availability Seamless Redundancy(HSR) Protocol for Automobile Networks (차세대 차량 네트워크를 위한 HSR (High-availability seamless Redundancy) 프로토콜 적용 연구)

  • Park, Jin-Pyo;Nsaif, Saad Allawi;Rhee, Jong-Myung
    • Journal of Satellite, Information and Communications
    • /
    • v.9 no.3
    • /
    • pp.33-40
    • /
    • 2014
  • One of the most important requirements for the Ethernet-based automobile is the reliability. In order to achieve this goal, we propose using the High-availability Seamless Redundancy (HSR) protocol (IEC 62439-3 clause 5) in these networks. The HSR protocol provides duplicated frame copies for each sent frame, which means that the destination node will receive at least one copy in case the second copy is lost due to a failure. In other words, there will be no network stoppage even if failure occurs. Moreover, the destination node will receive at least one frame copy with zero-recovery time (seamless) and it will not need to wait to receive the other copy if the first one is lost, which occurs it in the Ethernet standard, as a result of reconfiguration of the network paths. However, the main drawback of the HSR protocol is the unnecessary redundant traffic that is caused by the duplicated frames. Several solutions, including QR, VRing, RURT, and DVP, have already been proposed to improve the traffic performance of the HSR protocol. In this paper, we propose three automobile network topologies. each of which has pros and cons depending on the automobile requirements. Then we applied the HSR protocol with and without the QR and VRing approaches to each scenario. The comparison among these topologies depend on the traffic performance result for each of them. The QR and VRing approaches give a better traffic reduction percentage, ranging from 48% to 75% compared to the standard HSR protocol. Therefore they could limit the redundant traffic in automobile networks when the HSR protocol is used instead of the Ethernet network, which does not provide any seamless recovery if a failure occurs.

A Systemic Review of Pulse Contour Analysis and Fourier Spectrum Analysis on the Photoplethysmography of Digit (지첨용적맥파의 파형분석과 주파수분석에 대한 문헌적 연구)

  • Nam, Tong-Hyun;Park, Young-Bae;Park, Young-Jae;Shin, Sang-Hoon
    • The Journal of the Society of Korean Medicine Diagnostics
    • /
    • v.11 no.1
    • /
    • pp.48-60
    • /
    • 2007
  • Palpation of the pulse has been used in Korean traditional medicine since ancient times to assess physical health. Pulse wave contour may be obtained by measuring arterial pressure or blood volume change of skin. The latter is called as Photoplethysmography(PPG) or digital volume pulse(DVP). The PPG signal is measured by a device comprising an infrared light sourece and a photodetector. Although less widely used, this technique deserves further consideration because of its simplicity and ease of use. The contour of the PPG is formed as a result of a complex interaction between the left ventricle and the systemic circulation. It usually exhibits an early systolic peak and an early diastolic peak. the first peak is formed mainly by pressure trasmitted along a direct path from the left ventricle to the finger. The second peak is formed in part by pressure transmitted along the aorta and large arteries to sites of impedance mismatch in the lower body. The contour of the PPG is sensitive to changes in arterial tone and is influenced by ageing and large artery stiffness. Measurements taken directly from the PPG or from its second derivative can be used to assess these properties. In some mathematical approaches, the extraction of periodic components using frequency analysis was tried to analysis of the PPG. But we don't understand yet what kind of factor in the cardiovascular system or human body is related with the respective specific Fourier components of PPG. This review describes the background to measurement principles, representative contour, contour analysis and frequency domain analysis of PPG, and current and future.

  • PDF