• 제목/요약/키워드: DT rate

검색결과 286건 처리시간 0.024초

Characterization of Solidification and Microstructure of an Al-Zn-Mg-Si Alloy

  • He Tian;Dongdong Qu;Zherui Tong;Nega Setargew;Daniel J. Parker;David StJohn;Kazuhiro Nogita
    • Corrosion Science and Technology
    • /
    • 제23권2호
    • /
    • pp.104-112
    • /
    • 2024
  • Al-Zn-Mg-Si alloy coatings have been developed to inhibit corrosion of cold rolled steel sheets, and an understanding of the alloy system helps prevent coating defects. We used a Bridgman furnace to characterise the nature and formation mechanisms of the phases present in the quaternary system with 0.4 wt% Fe. In the directional solidification experiments we imposed steep temperature gradients and varied the pull rate. After the samples were quenched in the furnace, detailed characterization of the samples was carried out by electron microscopy (SEM/EDS). From the dT/dt vs T plots of the cooling curves of the alloys, the solidification path was determined to be $Liquid{\longrightarrow[80]^{544-558}}{\alpha}-Al{\longrightarrow[80]^{453-459}}Al/Mg_2Si{\longrightarrow[80]^{371-374}}Al/Zn{\longrightarrow[80]^{331-333}}Zn/mgZn_2$. The formation mechanisms of the Mg and Zn containing phases and their morphology was discussed together with the effects of the cooling rate. Key findings include the lengthening of the mushy zone in directionally solidified samples remelted against a positive temperature gradient, as well as an enrichening of the α-Al phase by Zn through remelting. Mg2Si and other Si based phases were observed to adopt a much finer faceted microstructure in favour of a script-like microstructure when exposed to the higher cooling rate of coolant quenching.

벼에서 흑다리긴노린재 [Paromius exiguus (Distant)] (Hemiptera: Lygaeidae) 산란모델 및 생명표 (Temperature-dependent Oviposition Model and Life Table Parameters of Paromius exiguus (Distant) (Hemiptera: Lygaeidae) Growing on Rice)

  • 박창규;박홍현;서보윤
    • 한국응용곤충학회지
    • /
    • 제56권4호
    • /
    • pp.387-394
    • /
    • 2017
  • 벼에 반점미를 유발하는 흑다리긴노린재 [Paromius exiguus (Distant)]의 온도에 따른 산란 특성을 $17.5{\sim}35^{\circ}C$ 8개 항온조건 광주기 14L:10D에서 조사하고 산란모델 구축을 위한 단위 함수 개발 및 생명표 분석을 수행하였다. 성충 수명은 $17.5^{\circ}C$에서 123.8일로 가장 길었고, $32.5^{\circ}C$에서 23.6일로 가장 짧았으며 온도가 올라감에 따라 수명도 짧아졌다. 암컷 한 마리당 총산란수는 $30^{\circ}C$에서 585.2개로 가장 많았으며, $17.5^{\circ}C$에서 21.5개로 가장 적었다. 온도에 기반한 산란 모델 개발을 위해 성충노화율, 총산란수, 성충생존율 및 누적산란율 단위모델을 추정하였다. 총 산란수($r^2=0.83{\sim}0.85$)를 제외한 3개의 단위모델 모두에서 높은 수준의 모델 적합성을 보였다($r^2=0.92{\sim}0.98$). 온도에 따른 흑다리긴노린재 생명표 매개변수들을 추정하였다. 순증가율($R_0$)은 $30^{\circ}C$에서 118.21로 가장 높았다. 평균 세대기간(T)은 $32.5^{\circ}C$에서 32.99일로 가장 짧았으며, 개체군 배수기간(Dt)은 $30^{\circ}C$에서 5.69일로 가장 짧았다. 내적자연증가율($r_m$)과 기간증가율(${\lambda}$)은 $30^{\circ}C$에서 가장 커 각각 0.122, 1.129였다.

The Reduction of Np(VI) by Acetohydroxamic Acid in Nitric Acid Solution

  • Chung, Dong-Yong;Lee, Eil-Hee
    • Bulletin of the Korean Chemical Society
    • /
    • 제26권11호
    • /
    • pp.1692-1694
    • /
    • 2005
  • Spent nuclear fuel is reprocessed commercially by the chemical process to recover U and Pu. Recently, new salt-free reagents to separate plutonium and neptunium from uranium suitable for use in a single cycle flowsheet have been developed. Acetohydroxamic acid $(CH_3CONHOH)$ has been taken much interest in as a complexing agent capable of selective stripping of tetravalent actinides from U(VI) when actinides are present in the solvent stream of the advanced PUREX process. Additionally acetohydroxamic acid will rapidly reduce Np(VI) to inextractable Np(V) thus allowing the separation of Np from U. In this study, the rate equation for the reduction of Np(VI) to Np(V) in nitric acid aqueous solution has been determined as: $-[NpO_2^{2+}]$/dt = $k[NpO_2^{2+}]$[AHA] with k = 191.2 ${\pm}$ 11.2 $M^{-1}s^{-1}$ at 25 ${\pm}$ 0.5 ${^{\circ}C}$ and $[HNO_3]$ = 1.0 M. Comparison with other reductants available in the literature, acetohydroxamic acid is a strong one for $NpO_2^{2+}$.

스케일링 환자들의 정기적인 스케일링과 비정기적인 스케일링의 구강건강행동지수와 구강건강지수 비교 (Comparison of Oral Health Behavior and Oral Health Indexes between Patients Undergoing Scaling Regularly and Those Undergoing Scaling Irregularly)

  • 김유린
    • 보건의료산업학회지
    • /
    • 제11권1호
    • /
    • pp.171-180
    • /
    • 2017
  • Objectives : The objective of this study was to compare oral health behaviors and oral health indices between regular scaling group and irregular scaling group. Methods : This study was performed at M Dental Clinic in Busan on 352 dental patients treated between January 2014 and June 2015 using V6.0 software and medical interviews. The 352 patients were divided into 3 groups and oral health behavior (OHB) and oral health indices were compared. Results : The OHB scores significantly differed among Groups C and A. Group C had the lowest number of "Bad" scores for the Simplified Debris Index (S-DI), Simplified Calculus Index (S-CI), and Simplified Oral Hygiene Index (S-OHI). Groups B and A had the lowest number of "Excellent" scores. Group C had the lowest bleeding on probing (BOP), calculus rate (CR) and decayed teeth (DT). Furthermore, Group C had the highest number of missing teeth (MT) and filled teeth (FT). Conclusions : Patients who underwent regular scaling had the highest OHB and oral health index scores. This emphasizes the importance of regular scaling for prevention and early detection of oral disease.

Magnetic Design of Flyback Type Snubber for IGCT Applications

  • Shirmohammadi, Siamak;Lama, Amreena;Suh, Yongsug
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2016년도 전력전자학술대회 논문집
    • /
    • pp.367-368
    • /
    • 2016
  • 10kV IGCT has been recently developed and has the potential to push wind turbine systems to higher power and voltage rating. Converters employing IGCTs need snubber and OVP circuit to limit the rate of current's rising and peak over voltage across IGCT during turn on and off state, respectively. The conventional RCD snubber which is used in such power converter dissipates a significant amount of power. In order to reduce the amount of energy lost by conventional RCD snubber, this paper proposes flyback type snubber comprising two coils wound on a magnetic core. The flyback snubber not only meets all of the IGCTs characteristics during on and off-state but also significantly saves the power loss. Modern magnetic model using permeance-capacitance analogy leads to more accurate loss analysis of flyback type di/dt snubber circuit in 3-level NPC type back-to-back VSC. In turns, the comparison between conventional and flyback type snubber yield the effectiveness of proposed snubber in wind turbine systems.

  • PDF

Oxidation Behavior of U-0.75 wt% Ti Chips in Air at 250-50$0^{\circ}C$

  • Kang, Kweon-Ho;Shin, Hyun-Kyoo;Kim, Chul;Park, Young-Moo
    • 에너지공학
    • /
    • 제5권2호
    • /
    • pp.193-197
    • /
    • 1996
  • A study was conducted on the oxidation behavior of U-0.75 wt% Ti chips (Depleted Uranium, DU chips) using an XRD and a thermogravimetric analyzer in the temperature range from 250 to 500$^{\circ}C$ in air. At the temperature lower than 400$^{\circ}C$, DU chips were converted to UO$_2$, U$_3$O$\_$7/, and U$_3$O$\_$8/ whereas at the temperature higher than 400$^{\circ}C$, DU chips were completely converted to U$_3$O$\_$8/, the most stable form of uranium oxide. The activation energy for the oxidation of DU chips is found, 44.9 kJ/mol and the oxidation rate in terms of weight gain (%) can be expressed as; dW/dt8.4${\times}$10$^2$e(equation omitted) wt%/min (250$\leq$T($^{\circ}C$) $\leq$ 500) where W=weight gain (%), t=time and T=temperature.

  • PDF

Friability 시험에 의한 둔감화약의 기계적 충격 감도 평가 연구 (A study on friability test to assess the mechanical impact sensitivity of insensitive explosives)

  • 박정수;박희덕;김성호;이정관
    • 한국군사과학기술학회지
    • /
    • 제4권1호
    • /
    • pp.20-29
    • /
    • 2001
  • We recently developed a friability test procedure, which will be used as one of substance tests for Extremely Insensitive Detonating Substances(EIDSs) in Test Series 7 of the United Nations. This test was intended to assess the susceptibility of insensitive explosives to the break-up as high strain rate and subsequent ignition characteristics of the deformed material. We designed an air gun system using the hydro code simulation. The projectile velocities of the gun were in good agreement with those predicted by the hydro code with an inert material. Three different types of explosives, melt castable Comp B, castable plastic bonded explosives(PBXs), and pressable PBXs were tested during the development of the test procedure. Two tastable PBXs, i.e. DXD-09 and DXD-10, which are currently under development as candidate formulations of EIDS were classified as EIDS, since test results with these formulations were far better than the criterion of the UN Test Series 7.

  • PDF

잡견을 이용한 실험적 뇌사모델에서 뇌사가 혈역학적 변화와 심근손상에 미치는 영향 -제1보;급격한 뇌압의 상승에 의한 뇌사모델에서의 혈역학적 및 심전도학적 변화- (Effect of the Brain Death on Hemodynamic Changes and Myocardial Damages in Canine Brain Death Model -Hemodynamic and Electrocardiographic Changes in the Brain Death Model Caused by Sudden Increase of Intracranial Pressure-)

  • 조명찬
    • Journal of Chest Surgery
    • /
    • 제28권5호
    • /
    • pp.437-442
    • /
    • 1995
  • We developed an experimental model of brain death using dogs. Brain death was caused by increasing the intracranial pressure[ICP suddenly by injecting saline to an epidural Foley catheter in five female mongrel dogs[weight, 20-25Kg .Hemodynamic and electrocardiographic changes were evaluated continuously during the process of brain death. 1. Abrupt rise of ICP after each injection of saline followed by a rapid decline to a new steady-state level within 15 minutes and the average volume required to induce brain death was 7.6$\pm$0.8ml.2. Body temperature, heart rate, mean pulmonary arterial pressure, left ventricular[LV enddiastolic pressure and cardiac output was not changed significantly during the process of brain death, but there was an increasing tendency.3. Mean arterial pressure and LV maximum +dP/dt increased significantly at the time of brain death.4. Hemodynamic collapse was developed within 140 minutes after brain death.5. Marked sinus bradycardia followed by junctional rhythm was seen in two dogs and frequent VPB`s with ventricular tachycardia was observed in one dog at the time of brain death. Hyperdynamic state develops and arrhythmia appears frequently at the time of brain death. Studies on the effects of brain death on myocardium and its pathophysiologic mechanism should be followed in the near future.

  • PDF

디지털 방송용 한글 허프만 부호 설계 및 PSIP 구조 (Huffman Code Design and PSIP Structure of Hangul Data for Digital Broadcasting)

  • 황재정;진경식;한학수;최준영;이진환
    • 방송공학회논문지
    • /
    • 제6권1호
    • /
    • pp.98-107
    • /
    • 2001
  • 본 논문은 한글 텍스트 데이터에 대한 부호화 효율을 극대화시키는 관점에서 예외 부호화를 통해 최적의 허프만 부호를 얻는 다. 한글 코드는 표준 완성형과 유니 코드를 대상으로 하였으며 같은 허프만 부호를 부여하였다. 현재 우리나라의 디지털 TV는 한글 문자를 압축하지 않고 전송하는 형태이며. 본격적인 데이터 방송이 시작되면 한글 데이터가 차지하는 전송량으로 인한 심자 한 문제가 야기된다. 본 논문에서는 데이터 방송에서 문제가 되는 전송량을 줄이기 위해 한글 진용 퇴적의 허프만 부호를 생성한 다. 미국의 ATSC 표준을 바탕으로 한 디지털 TV 국내 표준에 적용하기 위해 프로그램 및 시스템 프로토콜(PSIP) 구조를 제안한 다. 결과로서. 발생확률 0.0043 이하의 확률을 갖는 문자를 예외 부호화하여 최대 47%의 압축율을 얻는 기법을 제안하였다.

  • PDF

양손 전극의 임피던스법을 이용한 심박출량 측정의 최적화 (Optimization of Measuring Cardiac Output by Both Hands Electrode Impedance Method)

  • 정상오;심명헌;정운모;김민용;윤찬솔;윤형로
    • 전기학회논문지
    • /
    • 제60권9호
    • /
    • pp.1770-1776
    • /
    • 2011
  • In this study, a new method that can estimate ICG data from a subject's both hands to measure Cardiac Output under convenient sensor environment. With this aim, a grip-type electrode was implemented to measure ICG. To improve the accuracy of measurement, the regression equation was extracted using multiple bio-parameters and our result was compared with the thoracic ICG equipment(Physio Flow$^{(R)}$, PF104D, Manatec Biomedical, France), which is being used in clinics. The subjects consist of 26 men and 4 women(age in $22.0{\pm}3.32$). They are no cardiac disease. Parameters available for regression model were used gender, BMI, MBP, LVET, dZ/dt(max), distance between the measured electrodes, body impedance, and PTT. As a result of analyzing the ICG measurement value on thorax and both hands, the correlation with stroke volume, heart rate, and cardiac output was $R^2$=0.853, $R^2$=0.958 and $R^2$=0.899, respectively.