• Title/Summary/Keyword: DSF Model

Search Result 18, Processing Time 0.027 seconds

Numerical Study of Particle Collection Performance of Electrostatic Precipitator Integrated with Double Skin Façade in Residential Buildings (주거건물용 이중외피 통합형 전기집진기의 미세먼지 집진성능 수치해석 평가)

  • Eom, Ye Seul;Choi, Dong Hee;Kang, Dong Hwa
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.34 no.12
    • /
    • pp.73-82
    • /
    • 2018
  • The objective of this study was to evaluate particle collection performance of electrostatic precipitator (ESP) integrated with double skin façade in naturally ventilated residential buildings using numerical method. To evaluate the efficiency, computational fluid dynamics (CFD) simulation based on electric potential and Lagrangian method was applied. The CFD model was validated by comparing the simulated results with the experimental data including thermal characteristic of double skin façade (DSF) and particle removal characteristic of electrostatic precipitator. The validation results showed that the root mean square error (RMSE) between predicted values and measured values of velocity and temperature in intermediate space of DSF was 1.2%. The adequacy of ion space charge density and turbulent model were determined. The RMSE between predicted values and measured values of collection efficiency of ESP was 9.2%. In addition, the case study was performed to present the application of the numerical method based on validation results of ESP integrated with façade.

A statistical framework with stiffness proportional damage sensitive features for structural health monitoring

  • Balsamo, Luciana;Mukhopadhyay, Suparno;Betti, Raimondo
    • Smart Structures and Systems
    • /
    • v.15 no.3
    • /
    • pp.699-715
    • /
    • 2015
  • A modal parameter based damage sensitive feature (DSF) is defined to mimic the relative change in any diagonal element of the stiffness matrix of a model of a structure. The damage assessment is performed in a statistical pattern recognition framework using empirical complementary cumulative distribution functions (ECCDFs) of the DSFs extracted from measured operational vibration response data. Methods are discussed to perform probabilistic structural health assessment with respect to the following questions: (a) "Is there a change in the current state of the structure compared to the baseline state?", (b) "Does the change indicate a localized stiffness reduction or increase?", with the latter representing a situation of retrofitting operations, and (c) "What is the severity of the change in a probabilistic sense?". To identify a range of normal structural variations due to environmental and operational conditions, lower and upper bound ECCDFs are used to define the baseline structural state. Such an approach attempts to decouple "non-damage" related variations from damage induced changes, and account for the unknown environmental/operational conditions of the current state. The damage assessment procedure is discussed using numerical simulations of ambient vibration testing of a bridge deck system, as well as shake table experimental data from a 4-story steel frame.

Analysis of Spray Combustion for the Performance Prediction of Liquid Rocket Combustor (3차원 분무연소장 해석에 의한 액체추진기관 연소실 성능예측에 대한 연구)

  • 황용석;윤웅섭
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.3 no.3
    • /
    • pp.31-39
    • /
    • 1999
  • In this paper, numerical experiment is attempted to analyze and compare the combustion efficiency of the burning sprays due to OFO, FOF triplet / FOOF split doublet injectors. Preconditioned Wavier-Stokes equation system with low Reynolds number $\kappa$-$\varepsilon$ model for turbulence closure, is LU-SGS time-integrated. Spray processes are modeled by DSF analysis with experimentally determined injection characteristics. n-heptane/air global reaction model approximates the combustion for simplicity, and the influence of turbulence on the chemical reaction is included using eddy dissipation model. The results showed the FOF triplet injector of highest combustion efficiency, whereas the OFO type of poet performance. It was also observed that the droplet mean diameter and the average gas temperature due to the mixing efficiency, are the representative parameters for the performance design of combustion.

  • PDF

A Tank Model Shell Program for Simulating Daily Streamflow from Small Watersheds (Tank모형 쉘프로그램을 이용한 중소하천의 일유출량 추정)

  • 박승우
    • Water for future
    • /
    • v.26 no.3
    • /
    • pp.47-61
    • /
    • 1993
  • A menu-driven shell program DSFS (Daily Streamflow Simulation Model), that can process the input data, optimize the parameters, execute the program, and graphically display the results of a modified tank model, was developed and applied to simulating daily streamflow from small watersheds. The model defines daily watershed evapotranspiration losses from potential values multiplied by monthly landuse coefficients and correction factors for soil water storage levels. The parameters were calibrated using observed hydrologic data for fifteen watersheds, and the results were correlated with watershed parameters to define empirical relationships. The proposed model was tested with streamflow data of ungaged conditions, and the simulation results overestimated the annual runoff.

  • PDF

Turbulent Spray Combustion due to Triplet/Split Doublet Injectors (삼중/분리 충돌형 분사특성에 따른 난류 분무연소장 해석)

  • Hwang Yong-Sok;Yoon Woong-Sup
    • 한국전산유체공학회:학술대회논문집
    • /
    • 1998.11a
    • /
    • pp.211-219
    • /
    • 1998
  • Propellants pressurized and fed into the combustion chamber undergoes the mechanical, chemical combustion processes. Along with their distinctive physical characteristics, propellant combustion is typically divided into the processes; injection, atomization, mixing, vaporization and chemical reaction. These processes assumed to happen in a serial manner are strongly coupled, thereby involves formidable physical complexities. In this study a numerical experiment is attempted to simulate the burning sprays due to OFO, FOF triplet / FOOF split doublet injectors. Based on Eulerian-Lagrangian frame, Navier-Stokes equation system for compressible flows is preconditioned with low Reynolds number $k-{\varepsilon}$ turbulent model and time-integrated by LU-SGS, and the sprays are described by DSF model with the characteristics initialized by experimentally determined spray characteristics. Simplified single global reaction model approximates heptane-air reaction. It was observed that FOOF split doublet injector shows better atmization with shortest residence and the FOF triplet injector produces better combustion performance.

  • PDF

The Application of Preconditioning in Laminar Spray Combustion Analysis (예조건화 압축성 알고리듬을 이용한 층류 분무연소장 해석)

  • Hwang Yong-Sok;Yoon Woong-Sup
    • 한국전산유체공학회:학술대회논문집
    • /
    • 1998.05a
    • /
    • pp.128-137
    • /
    • 1998
  • In this numerical experiment, the preconditioned compressible Navier-Stokes equation is tested to analyze the laminar spray combustion. Sprayed flow field is formulated by Eulerian-Lagrangian system for the gas and liquid phases each. DSF(Deterministic Separated Flow) model was adopted for the sprays with the vortex model to describe transients of individual droplet heating. Simplified single global reaction model approximates methanol-air reaction with and without disk flame holder. The equation system is discretized by finite difference technique and time integrated by LU-SGS. Due to greatly simplified chemical reaction mechanism and the lack of experimental evidences, most of the efforts were devoted to show the applicability and robustness of preconditioned compressible flow calculation algorithm. Computation results in qualitatively reasonable combusting flow field, hence it is believed that further refinement are required to produce quantitatively accurate solutions.

  • PDF

ANALYSES OF ANNULAR LINEAR INDUCTION PUMP CHARACTERISTICS USING A TIME-HARMONIC FINITE DIFFERENCE ANALYSIS

  • Seong, Seung-Hwan;Kim, Seong-O
    • Nuclear Engineering and Technology
    • /
    • v.40 no.3
    • /
    • pp.213-224
    • /
    • 2008
  • The pumping of coolant in a liquid metal fast reactor may be performed with an annular linear induction electro-magnetic (EM) pump. Linear induction pumps use a traveling magnetic field wave created by poly-phase currents, and the induced currents and their associated magnetic field generate a Lorentz force, whose effect can be the pumping of the liquid metal. The flow behaviors in the pump are very complex, including a time-varying Lorentz force and pressure pulsation, because an induction EM pump has time-varying magnetic fields and the induced convective currents that originate from the flow of the liquid metal. These phenomena lead to an instability problem in the pump arising from the changes of the generated Lorentz forces along the pump's geometry. Therefore, a magneto-hydro-dynamics (MHD) analysis is required for the design and operation of a linear induction EM pump. We have developed a time-harmonic 2-dimensional axisymmetry MHD analysis method based on the Maxwell equations. This paper describes the analysis and numerical method for obtaining solutions for some MHD parameters in an induction EM pump. Experimental test results obtained from an induction EM pump of CLIP-150 at the STC "Sintez," D.V. Efremov Institute of Electro-physical Apparatus in St. Petersburg were used to validate the method. In addition, we investigated some characteristics of a linear induction EM pump, such as the effect of the convective current and the double supply frequency (DSF) pressure pulsation. This simple model overestimated the convective eddy current generated from the sodium flow in the pump channel; however, it had a similar tendency for the measured data of the pump performance through a comparison with the experimental data. Considering its simplicity, it could be a base model for designing an EM pump and for evaluating the MHD flow in an EM pump.

Drought Risk Analysis Using Stochastic Rainfall Generation Model and Copula Functions (추계학적 강우발생모형과 Copula 함수를 이용한 가뭄위험분석)

  • Yoo, Ji Young;Shin, Ji Yae;Kim, Dongkyun;Kim, Tae-Woong
    • Journal of Korea Water Resources Association
    • /
    • v.46 no.4
    • /
    • pp.425-437
    • /
    • 2013
  • This study performed the bivariate drought frequency analysis for duration and severity of drought, using copula functions which allow considering the correlation structure of joint features of drought. We suggested the confidence intervals of duration-severity-frequency (DSF) curves for the given drought duration using stochastic scheme of monthly rainfall generation for 57 sites in Korea. This study also investigated drought risk via illustrating the largest drought events on record over 50 and 100 consecutive years. It appears that drought risks are much higher in some parts of the Nakdong River basin, southern and east coastal areas. However, such analyses are not always reliable, especially when the frequency analysis is performed based on the data observed over relatively short period of time. To quantify the uncertainty of drought frequency curves, the droughts were filtered by different durations. The 5%, 25%, 50%, 75%, and 95% confidence intervals of the drought severity for a given duration were estimated based on the simulated rainfall time series. Finally, it is shown that the growing uncertainties is revealed in the estimation of the joint probability using the two marginal distributions since the correlation coefficient of two variables is relatively low.