• Title/Summary/Keyword: DROP-IN

Search Result 6,161, Processing Time 0.035 seconds

Behaviour of steel-fibre-reinforced concrete beams under high-rate loading

  • Behinaein, Pegah;Cotsovos, Demetrios M.;Abbas, Ali A.
    • Computers and Concrete
    • /
    • v.22 no.3
    • /
    • pp.337-353
    • /
    • 2018
  • The present study focuses on examining the structural behaviour of steel-fibre-reinforced concrete (SFRC) beams under high rates of loading largely associated with impact problems. Fibres are added to the concrete mix to enhance ductility and energy absorption, which is important for impact-resistant design. A simple, yet practical non-linear finite-element analysis (NLFEA) model was used in the present study. Experimental static and impact tests were also carried out on beams spanning 1.3 meter with weights dropped from heights of 1.5 m and 2.5 m, respectively. The numerical model realistically describes the fully-brittle tensile behaviour of plain concrete as well as the contribution of steel fibres to the post-cracking response (the latter was allowed for by conveniently adjusting the constitutive relations for plain concrete, mainly in uniaxial tension). Suitable material relations (describing compression, tension and shear) were selected for SFRC and incorporated into ABAQUS software Brittle Cracking concrete model. A more complex model (i.e., the Damaged Plasticity concrete model in ABAQUS) was also considered and it was found that the seemingly simple (but fundamental) Brittle Cracking model yielded reliable results. Published data obtained from drop-weight experimental tests on RC and SFRC beams indicates that there is an increase in the maximum load recorded (compared to the corresponding static one) and a reduction in the portion of the beam span reacting to the impact load. However, there is considerable scatter and the specimens were often tested to complete destruction and thus yielding post-failure characteristics of little design value and making it difficult to pinpoint the actual load-carrying capacity and identify the associated true ultimate limit state (ULS). To address this, dynamic NLFEA was employed and the impact load applied was reduced gradually and applied in pulses to pinpoint the actual failure point. Different case studies were considered covering impact loading responses at both the material and structural levels as well as comparisons between RC and SFRC specimens. Steel fibres were found to increase the load-carrying capacity and deformability by offering better control over the cracking process concrete undergoes and allowing the impact energy to be absorbed more effectively compared to conventional RC members. This is useful for impact-resistant design of SFRC beams.

An Aggregate Fairness Marker without Per Flow Management for Fairness Improvement of Assured Service in DiffServ (DiffServ 방식의 Assured Service 에서 플로별 관리 없이 Fairness향상을 위한 Aggregate Fairness Marker)

  • Park, Ji-Hoon;Hur, Kyeong;Eom, Doo-Seop
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.29 no.7B
    • /
    • pp.613-627
    • /
    • 2004
  • In this paper, we propose an Aggregate Fairness Maker (ARM) required for an Edge router to improve fairness of throughput among the flows of Assured Service in DiffServ with different round trip time (RTT) and we propose a user flow Three Color Marker (uf-TCM) as a flow marker that marks packets from the flow as green, yellow, or red. A yellow packet is the packet that consumes loss token in uf-TCM as well as that is demoted green packet in AM due to disobey the aggregate traffic profile. The proposed AFH promotes yellow packet to green packet or demotes green packet to yellow packet through the fair method without per-flow management, and it improves the feirness of throughput among the flows as well as link utilization. A yellow packet and a red packet have the same drop precedence at Core Router in our scheme. So we can use the RIO buffer management scheme. We evaluated the performance of our proposed AFM and the REDP Marker that was proposed to improve fairness without per-flow management. Simulation results show that, compared with the REDP marker, proposed AFM can improve performance of throughput fairness among the flows with different RTT and link utilization under the over-provisioning, exact-provisioning, and under-provisioning network environments at Multiple DiffServ domains as well as at Single DiffServ domain.

A Dual Processing Load Shedding to Improve The Accuracy of Aggregate Queries on Clustering Environment of GeoSensor Data Stream (클러스터 환경에서 GeoSensor 스트림 데이터의 집계질의의 정확도 향상을 위한 이중처리 부하제한 기법)

  • Ji, Min-Sub;Lee, Yeon;Kim, Gyeong-Bae;Bae, Hae-Young
    • Journal of the Korea Society of Computer and Information
    • /
    • v.17 no.1
    • /
    • pp.31-40
    • /
    • 2012
  • u-GIS DSMSs have been researched to deal with various sensor data from GeoSensors in ubiquitous environment. Also, they has been more important for high availability. The data from GeoSensors have some characteristics that increase explosively. This characteristic could lead memory overflow and data loss. To solve the problem, various load shedding methods have been researched. Traditional methods drop the overloaded tuples according to a particular criteria in a single server. Tuple deletion sensitive queries such as aggregation is hard to satisfy accuracy. In this paper a dual processing load shedding method is suggested to improve the accuracy of aggregation in clustering environment. In this method two nodes use replicated stream data for high availability. They process a stream in two nodes by using a characteristic they share stream data. Stream data are synchronized between them with a window as a unit. Then, processed results are merged. We gain improved query accuracy without data loss.

Preimplantation Genetic Diagnosis for Single Gene Disorders (단일 유전자 질환에 대한 착상전 유전진단)

  • Lee, Hyoung-Song;Kim, Min-Jee;Kang, Inn-Soo
    • Journal of Genetic Medicine
    • /
    • v.6 no.2
    • /
    • pp.131-145
    • /
    • 2009
  • Preimplantation genetic diagnosis (PGD) has become an assisted reproductive technique for couples who are at risk that enables them to have unaffected baby without facing the risk of pregnancy termination after invasive prenatal diagnosis. The molecular biology and technology for single-cell genetics has reached an extremely high level of accuracy, and has enabled the possibility of performing multiple diagnoses on one cell using whole genome amplification. These technological advances have contributed to the avoidance of misdiagnosis in PGD for single gene disorders. Polymerase chain reaction (PCR)-based PGD will lead to a significant increase in the number of disorders diagnosed and will find more widespread use, benefiting many more couples who are at risk of transmitting an inherited disease to their baby. In this review, we will focus on the molecular biological techniques that are currently in use in the most advanced centers for PGD for single gene disorders, including biopsy procedure, multiplex PCR and post-PCR diagnostic methods, and multiple displacement amplification (MDA) and the problems in the single cell genetic analysis.

  • PDF

A Fast Motion Vector Search in Integer Pixel Unit for Variable Blocks Siz (가변 크기 블록에서 정수단위 화소 움직임 벡터의 빠른 검색)

  • 이융기;이영렬
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.40 no.5
    • /
    • pp.388-396
    • /
    • 2003
  • In this paper, a fast motion search algorithm that performs motion search for variable blocks in integer pixel unit is proposed. The proposed method is based on the successive elimination algorithm (SEA) using sum norms to find the best estimate of motion vector and obtains the best estimate of the motion vectors of blocks, including 16${\times}$8, 8${\times}$16, and 8${\times}$8, by searching eight pixels around the best motion vector of 16${\times}$16 block obtained from all candidates. And the motion vectors of blocks, including 8${\times}$4, 4${\times}$8, and 4${\times}$4, is obtained by searching eight pixels around the best motion vector of 8${\times}$8 block. The proposed motion search is applied to the H.264 encoder that performs variable blocks motion estimation (ME). In terms of computational complexity, the proposed search algorithm for motion estimation (ME) calculates motion vectors in about 23.8 times speed compared with the spiral full search without early termination and 4.6 times speed compared with the motion estimation method using hierarchical sum of absolute difference (SAD) of 4${\times}$4 blocks, while it shows 0.1dB∼0.4dB peak signal-to-noise ratio (PSNR) drop in comparison to the spiral full search.

The Measurement of Size of the Pedicle Using 3 Dimensional Reconstruction Image in Idiopathic Scoliosis (특발성 척추측만증 환자에서의 3차원적 재구성을 이용한 척추경의 크기 측정)

  • Heo, Jae-Hee;Ahn, Myun-Hwan
    • Journal of Yeungnam Medical Science
    • /
    • v.21 no.1
    • /
    • pp.40-50
    • /
    • 2004
  • Background: This study was conducted to analyze the height and width of the pedicle of the upper and lower levels on the concave and the convex sides. In addition, we checked for the appropriate pedicle screw size which could be screwed in without complications. Materials and Methods: Taking a simple AP radiography in a standing position, 99 vertebrae on the major curve with the possibility of 3-D reconstruction were analyzed after checking the CT in a supine position of 22 idiopathic scoliosis. We measured Cobb's angle from a simple radiograph, and measured the size of the isthmus by the Inner Space 3-D Editor after 3-D reconstruction with the Inner Space 3-D program in the DICOM file transformed from CT image. We then analyzed the size of pedicles of the upper and lower levels on the concave and the convex sides by measuring the height and width of the pedicle. Results: All pedicles on the concave side were smaller than those on the convex side. Their size increased as the measurement moved from the upper to lower vertebra, except for the upper thoracic vertebra. When the width of the pedicle through 3-D reconstruction was compared with the narrowest width of the pedicle measured by using CT, the width of the pedicles through 3-D reconstruction was statistically smaller (P<0.01). Most of the pedicles were tear-drop or kidney shaped rather than cylindrical. Conclusion: These results suggest that the use of the coronal plane through 3-D reconstruction would be necessary for an accurate measurement of the size of the pedicle. It is important to pay careful attention to the screw size and the screwing method considering the pedicle shape through 3-D reconstruction.

  • PDF

A Study on Mine Ventilation Network (광산 통기 네트워크 연구)

  • Kim, Soo Hong;Kim, Yun Kwang;Kim, Sun Myung;Jang, Yun Ho
    • Tunnel and Underground Space
    • /
    • v.27 no.4
    • /
    • pp.217-229
    • /
    • 2017
  • This study focuses on the improvement of the working environment in domestic collieries where temperature is increasing due to heat of the earth that is caused by the long-term mining. In order to improve the working environment of the mine, a ventilation evaluation was carried out for Hwasoon Mining Industry. In order to increase the ventilation efficiency of the mine, numerical analysis of the effect on temperature was carried out by using climsim, a temperature prediction program. The analysis shows that A coal mine needs $6,152m^3/min$ for in-flow ventilation rate but the total input air flowrate is $4,710m^3/min$, $1,442m^3/min$ of in-flow ventilation rate shortage. The 93 m hypothetical ventilation shaft from -395 ML to -488 ML could result about $3^{\circ}C$ temperature drop in the coal mine of -488 ML far. As a result of predicting the $CO_2$ concentration at -523 ML development using artificial neural network, the emission of $CO_2$ increased as the amount of coal and coal bed thickness increased. The factors that have the greatest effect on the amount of $CO_2$ emissions were coal layer thickness and coal mining. And, as the air quantity increases, it has a great effect on the decrease of carbon dioxide concentration.

Study on the Difference of Urine Sediment Preparation for Microscopic Examination (현미경검사를 위한 요침사 표본제작에 따른 차이 연구)

  • Lee, Hyeok-Jae;Park, Chul;Seo, Min-Young
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.49 no.4
    • /
    • pp.366-373
    • /
    • 2017
  • Urinalysis is considered to be easier and simpler than other tests. It has been known to cause no burden to patients, while offering important information on diagnosing, treating, and determining the prognoses of kidney and urinary tract diseases. Urinary sediments are usually performed by microscopic examination of centrifuged urine by technologist. The guidelines proposed by the Korean Association of External Quality Assessment Service are actually different from those actually practiced by medical institutions and taught to biomedical students in textbooks. Therefore, we verified whether different sediment preparation methods lead different test results. Specimens that tested positive from the occult blood and leukocyte esterase in the urine dipstick test were randomly selected for a microscopic examination. The differences in the urine sediment preparation affected the sediment concentrations, which influenced the cell grade and cell number per HPF. The first factor in determining the sediment concentration is the centrifugal force. Many medical institutions use 1,500 rpm as the centrifugal speed without considering the radius of the centrifuge; such a value may not be accurate for 400 G. Consequently, there were differences in urine concentrations, which influenced the results. The second factor is the amount of sediment in urine. Different amounts of the remaining supernatant led to different sediment concentration factors, again, causing different results. Furthermore, not only by using a pipette to obtain an accurate amount as stipulated, but also by roughly obtaining a drop, the microscopic examination using such a volume of sediment examined affected the results. Therefore, this study highlights the importance of standardization of urine sediment preparation procedures to promote consistency and accuracy across institutions.

Analysis of Broken Rice Separation Efficiency of a Laboratory Indented Cylinder Separator

  • Kim, Myoung Ho;Park, Seung Je
    • Journal of Biosystems Engineering
    • /
    • v.38 no.2
    • /
    • pp.95-102
    • /
    • 2013
  • Purpose: Using a laboratory indented cylinder separator, broken rice separation experiments were conducted and the characteristics of the separation process were studied to provide information for developing a prototype indented cylinder broken rice separator. Methods: Rice (Ilmi variety) milled in a local RPC was used for the experiment. Rice kernels were classified into four groups according to their length l; whole kernels (I > 3.75 mm), semi-whole kernels (2.5 < I < 3.75 mm), broken kernels (1.75 < I < 2.5 mm), and foreign matters (I < 1.75 mm). A laboratory grain cleaner, Labofix '90 (Schmidt AG, Germany) was used for the experiments. Experiments were designed as a $4{\times}4$ factorial arrangement in randomized blocks with three replications. Cylinder rotational speeds (17, 34, 51, 68 rpm) and trough angles (15, 37.5, 60, $82.5^{\circ}$) were the two factors and feed rates (25, 50 kg/h), indent shapes (Us, $S_1$ type), and indent sizes (2.5, 3.75 mm) were treated as the blocks. Two 125 g samples and one 125 g sample were taken at the cylinder outlet and from the trough, respectively. The whole, semi-whole, and broken kernel weight ratio of the samples and feed was determined by a rice sizing device. From these weight ratios, purities, degrees of extraction and coefficient of separation efficiency were calculated. Results: Trough angle, cylinder speed, and their interaction on the coefficient of separation efficiency were statistically significant. Cylinder speed of 17, 34, and 51 rpm made the most effective separation when the trough angle was $15^{\circ}$ or $37.5^{\circ}$, $60^{\circ}$, and $82.5^{\circ}$, respectively. Maximum values of coefficient of separation efficiency were in the range of 60 to 70% except when the indent size was 2.5 mm and were recorded for the combinations of low cylinder speed (17 rpm) with medium trough angle ($37.5^{\circ}$ or $60^{\circ}$). Indent shape did not appear to make any noticeable difference in separation efficiency. Conclusions: Due to the interaction effect, the trough angle needs to be increased appropriately when an increase in cylinder speed is made if a rapid drop of effectiveness of separation should be avoided. In commercial applications, $S_1$ type indents are preferred because of their better manufacturability and easier maintenance. For successful separation of broken kernels, the indent size should be set slightly bigger than the actual sizes of broken kernels: an indent size of 3.0 mm for separating broken kernels shorter than 2.5 mm.

Performance of Oscillating Water Column type Wave Energy Converter in Oblique Waves (사파중 진동수주형 파력발전장치의 성능평가)

  • Jin, Jiyuan;Hyun, Beom-Soo;Hong, Keyyong;Liu, Zhen
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.17 no.3
    • /
    • pp.182-188
    • /
    • 2014
  • In an oscillating water column (OWC)-type wave energy conversion system, the performance of the OWC chamber depends on the chamber shape, as well as the incident wave direction and pressure drop produced by the turbine. Although the previous studies on OWC chambers have focused on wave absorbing performance in ideal operating conditions, incident waves do not always arrive normally to the OWC chamber in real sea conditions, especially in fixed devices. The present study deals with experiments and numerical calculations to investigate the effects of wave direction on the performance of the OWC chamber. The experiments were carried out in a three-dimensional wave basin for five different wave directions, including the effect of turbine using the corresponding orifice. The wave elevation inside the chamber was measured at the center point under various incident wave conditions. The numerical study was conducted by using a numerical wave tank-based volume-of-fluid model to compare the results with experimental data and to reveal the detailed flows around the chamber.