• Title/Summary/Keyword: DROP-IN

Search Result 6,160, Processing Time 0.039 seconds

Pressure Drop in Two-Phase Flow Boiling of R134a, R123 and Their Mixture in Horizontal Tube

  • Lim, Tae-Woo
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.12 no.2
    • /
    • pp.70-78
    • /
    • 2004
  • An experimental study on the pressure drop during flow boiling for pure refrigerants Rl34a and R123, and their mixture was carried out in a uniformly heated horizontal tube. Tests were run at a pressure of 0.6㎫ and in the ranges of heat flux 5-50㎾/$m^2$, vapor quality 0-100 percent and mass velocity of 150-600 kg/$m^2$s. Generally, the two-phase frictional multiplier is used to predict the frictional pressure drop during the two-phase flow boiling. The obtained results have been compared to the existing various correlations for the two-phase multiplier. Also, the frictional pressure drop was compared to a few available correlations; The Lockhart-Martinelli correlation considerally overpredicted the frictional pressure drop data for mixture as well as pure components in the entire mass velocity ranges employed in the present study, while the Chisholm correlation underpredicted the present data. The Friedel correlation was found to satisfactorily correlate the frictional pressure drop data except for a low quality region.

The Study of Somatotype According to the Drop of Women in Their 20's (20대 여성의 드롭에 따른 체형 연구)

  • Park, Ju-Hee;Hong, Jung-Min;Yoon, Jin-Kyung
    • Fashion & Textile Research Journal
    • /
    • v.7 no.5
    • /
    • pp.494-500
    • /
    • 2005
  • This study classifies somatotype from exact measurements according to the women somatotype with different drop value and isfunctional and has high body fitness. This study was preceded in the following process. Took 147 women in their 20's measurement directly and grasped the general body characteristic, and classified somatotype according to distribution of drop. Drop value is classified into Drop I, Drop II, and Drop III. Drop I is the difference value between bust line and waist line measurement. Drop II is the difference value between hip line and waist line measurement. Drop III is the difference value between hip line and bust line measurement. Suggested distribution of somatotype based on drop istribution. Classified somatotype into 4 types according to the mixture of combination of Drop I, II, and III. Comprehended the characteristics of somatotype based on basic statistical data. Type 1, M type, displays 40 % distribution that is most high distribution rate among four types and it is normal type which is similar to average value in size in the this study. Type 2, A type, displays 32.4% and it's a lower half of their body developed type with a flat busted and hippy. Type 3, X type, displays 19% and it's a healthy type with tall height, slender waist and curves of bust and hip lines. Type 4, H type, displays 8.6% and it's a biggest type in size which is busty, full hipped and nearly has no curves of body line.

Influence of Longitudinal Arch of Foot on the Strength and Muscle Activity of the Abductor Hallucis in Subjects with and without Navicular Drop Sign

  • Jeon, In-Cheol
    • The Journal of Korean Physical Therapy
    • /
    • v.31 no.4
    • /
    • pp.222-227
    • /
    • 2019
  • Purpose: This study examined the influence of longitudinal arch on the strength and muscle activity of the abductor hallucis in the standing position in subjects with and without navicular drop signs. Methods: A sample of 34 subjects with and without navicular drop signs between 22 and 28 years of age were enrolled in this study. The strength and muscle activity of the abductor hallucis was measured using a tensiometer. The Smart KEMA System and electromyography device was used on the subjects with and without navicular drop signs. Two groups were classified using the navicular drop test to identify the longitudinal arch of the foot. The strength of the abductor hallucis was evaluated in standing, both with and without an external arch support condition. The two-way mixed ANOVA was used. The level of statistical significance was set to ${\alpha}=0.05$. Results: The strength and muscle activity of the abductor hallucis in standing was significantly higher with external arch support than that without the external arch support in the group with navicular drop signs. There was no significant difference in the abductor hallucis strength and muscle activity with and without external arch support in the subjects without navicular drop signs. Conclusions: The strength and muscle activity of the abductor hallucis in standing can be influenced by the external arch support in the group with navicular drop signs. The strength measurement of the abductor hallucis in standing should be separately performed in conditions with and without longitudinal arch of foot.

Comparison of the thickness of the gastrocnemius through ultrasonography during heel-drop exercise performance

  • Gal, Dan-Bee;Lee, Su-Young
    • Physical Therapy Rehabilitation Science
    • /
    • v.5 no.2
    • /
    • pp.89-94
    • /
    • 2016
  • Objective: This study was aimed to compare the thickness and pennation angle of gastrocnemius through ultrasonography during the heel-drop exercise on ankle dorsiflexion angle. Design: Cross-sectional study. Methods: Nineteen normal adults in their 20s had voluntarily participated in this study. All subjects performed the ankle heel-drop exercise with ankle dorsiflexed to $0^{\circ}$, $10^{\circ}$, and $20^{\circ}$: heel-drop exercise with ankle dorsiflexed to $0^{\circ}$ was executed on floor-level, heel-drop exercise with ankle dorsiflexed to $10^{\circ}$ on a wooden-block of 2.3 cm in height, and heel-drop exercise with ankle dorsiflexed to $20^{\circ}$ on a wooden-block of 5.5 cm in height. In each regimen, the subjects completed a session of 100 heel-drop exercises (10 repetitions${\times}$10 sets; with 30 seconds rest following each set; with 24 hours rest following each exercise). Before and immediately after each heel-drop exercise, the thickness and pennation angle of gastrocnemius were measured using an ultrasonography. Results: After the performance of the heel drop exercises with ankle dorsiflexed to $0^{\circ}$, $10^{\circ}$, and $20^{\circ}$, the thickness of the gastrocnemius was significantly higher than pre-exercise (p<0.05), and furthermore heel-drop exercise with ankle dorsiflexed to $10^{\circ}$ was significantly higher than exercise with the ankle dorsiflexed to $0^{\circ}$ (p<0.05). However, as for the pennation angle of the gastrocnemius, there were no significant changes after each heel-drop exercise. Conclusions: This finding suggest that the heel-drop exercise with ankle dorsiflexed to $0^{\circ}$, $10^{\circ}$, and $20^{\circ}$ is effective on the strengthening of the gastrocnemius. Furthermore, the heel-drop exercise with the ankle dorsiflexed to $10^{\circ}$ is more effective than with the ankle dorsiflexed to $0^{\circ}$.

Analysis of Pulsed GMAW Using Force-Displacement Model (힘-변위 모델을 이용한 펄스 GMAW의 해석)

  • Arif, Nabeel;Lee, Jae-Hak;Yoo, Choong-Don
    • Journal of Welding and Joining
    • /
    • v.27 no.1
    • /
    • pp.59-64
    • /
    • 2009
  • In order to determine the One-Drop One-Pulse(ODOP) condition of the pulsed gas metal arc(GMA) welding, the drop detaching phenomenon during the peak time is investigated using the force-displacement model. The drop detaching criterion is established based on the displacement of the pendant drop, and the forces exerted on the drop are calculated using the Modified Force Balance Model(MFBM). The effects of wire melting on the drop size and force are included in the force-displacement model. While the peak current has most significant effects on the drop detaching time, the initial drop mass prior to the peak time also influences drop transfer. The calculated results show good agreements with the experimental data, which implies that the ODOP condition can be predicted using the force-displacement method.

Gate Length Optimization for Minimum Forward Voltage Drop of IGBTs

  • Moon Jin-Woo;Park Dong-Wook;Choi Yearn-Ik;Chung Sang-Koo
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • v.5C no.6
    • /
    • pp.246-250
    • /
    • 2005
  • The forward voltage drop of IGBT is studied numerically and analytically as a function of gate length. An analytical expression is presented for the first time for the surface potential variation along the channel layer under the gate of IGBT. The surface potential drop and the carrier density near the surface allow calculation of the forward voltage drop of IGBT analytically as a function of the gate length. The voltage-drop in the drift region near the gate decreases exponentially, whereas that on the surface increases linearly with increasing the gate length, the sum of which exhibits an optimum gate length, resulting in a minimum forward voltage drop. Based on the surface potential drop, a remodelling of the forward voltage drop of IGBT is also proposed.

Challenging a Single-Factor Analysis of Case Drop in Korean

  • Chung, Eun Seon
    • Language and Information
    • /
    • v.19 no.1
    • /
    • pp.1-18
    • /
    • 2015
  • Korean marks case for subjects and objects, but it is well known that case-markers can be dropped in certain contexts. Kwon and Zribi-Hertz (2008) establishes the phenomenon of Korean case drop on a single factor of f(ocus)-structure visibility and claims that both subject and object case drop can fall under a single linguistic generalization of information structure. However, the supporting data is not empirically substantiated and the tenability of the f-structure analysis is still under question. In this paper, an experiment was conducted to show that the specific claims of Kwon and Zribi-Hertz's analysis that places exclusive importance on information structure cannot be adequately supported by empirical evidence. In addition, the present study examines H. Lee's (2006a, 2006c) multi-factor analysis of object case drop and investigates whether this approach can subsume both subject and object case drop under a unified analysis. The present findings indicate that the multi-factor analysis that involves the interaction of independent factors (Focus, Animacy, and Definiteness) is also compatible with subject case drop, and that judgments on case drop are not categorical but form gradient statistical preferences.

  • PDF

A Study on the Classification of Elderly Male's Body Type (노년남성의 체형분류에 관한 연구)

  • 김수현;이정란
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.27 no.6
    • /
    • pp.624-634
    • /
    • 2003
  • The purpose of this study was to classify body types of elderly male aged between 60 and 80. 40 direct items and 22 indexes were measured. The result were as follows. First. through the factor analysis of indexes, 8 factors were extracted upon factor scores, 4 clusters represented characteristics of elderly male's body type. Type 1 indicates flat and bend-forward type. Type 2 indicates fat and bend-forward type. Type 3 indicates lean-back type and is a little bit fat and the waist is round. Type 4 indicates a straight type in which the chest and the hip are developed. Second, drop was needed to discriminate elderly male's body type. 3 types of drop were extracted. The body type with big drop is Y type in which the drop distance is between 14 and 22cm. The body type with standard drop is A type in which the drop distance is between 6 and 14cm. The body type with small drop is B type in which the drop distance is between -4 and 6cm. Third, when the types of appearance rate were combined, 7 body types of elderly male showed high appearance rate; A1, B1, A2, B2, A3, A4, B4. According to the above result, flat and bended-forward type with drop A was dominant body type of elderly male.

Pressure Drop in a Circular Pipe of Waste Collection Piping System (쓰레기 관로 이송 시스템의 관로 압력강하 평가)

  • Jang, Choon-Man;Lee, Sang-Yun;Suh, Sang-Ho
    • The KSFM Journal of Fluid Machinery
    • /
    • v.10 no.4
    • /
    • pp.55-60
    • /
    • 2007
  • This paper describes an evaluation method of pressure drop in a circular pipe of waste collection piping system. Accurate pressure drop in a piping system is very important to determine the capacity of turbo blower, which is one of the main elements in the system. Three-dimensional Navier-Stokes analysis is introduced to analyze the pressure drop in the piping system. Organic waste is selected and modeled using the result of site survey performed in an apartment area. Evaluation method of pressure drop used In the present numerical simulation is performed in the shortened pipe line prior to the calculation of the real system. Throughout the numerical simulation, pressure drop in a waste pipe is obtained and compared to the value determined by analytical method. The pressure drop obtained by numerical simulation has a good agreement with that of the analytic method. It is noted that present evaluation method is effective to determine a pressure drop in the piping system. Detailed flow characteristics inside the pipe line are also analyzed and discussed.

Effect of Eye Drop Education on Adherence to Glaucoma Medication (점안 지도가 항녹내장 안약의 처방 순응도에 미치는 영향)

  • Park, Kyung-Ji;Song, Hyun Ju;Sohn, Uy Dong
    • YAKHAK HOEJI
    • /
    • v.57 no.2
    • /
    • pp.139-149
    • /
    • 2013
  • Glaucoma is a potentially blinding chronic disease requiring life-long commitment to medical therapy. Failure to adhere to anti-glaucoma treatment may lead to disease progression and visual loss. This study surveyed the adherence to glaucoma eye drop and eye drop instillation technique of glaucoma patients and analyzed the improvement of the adherence and installation technique after patient education for eye drop instillation instructions. Collected responses were statistically analyzed using Kruskal-Wallis test, Mann-Whitney test, Chi-square test, Fisher's exact test, Spearman's correlation coefficient, or one sample proportion test. The survey after patient education for proper eye drop instillation revealed that, even if the patients experienced the adverse effect of their eyes getting dry, they used the eye drop more regularly. They were better at instillation techniques like putting the eye drop inside the eye, and also avoiding applying too much medication or touching their eye with the eye drop bottle. Also, when the patients were divided into groups based on etiologic division, there was difference among groups regarding which category they answered has improved. The result showed improvement in adherence to glaucoma eye drop and eye drop instillation technique after patient education, implicating that patient education is an important aspect of eye care for glaucoma patient and helps them participate in the proper management.