• Title/Summary/Keyword: DQ 변환

Search Result 45, Processing Time 0.022 seconds

Dynamic Analysis of Variable Speed Wind Power Systems with Doubly-Fed Induction Generators (이중여자 유도발전기에 의한 가변속 풍력 발전시스템의 동특성 해석)

  • Choi, Jang-Young;Jang, Seok-Myeong
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.55 no.6
    • /
    • pp.325-336
    • /
    • 2006
  • This paper deals with the dynamic analysis of variable speed wind power systems with doubly-fed induction generators (DFIG). First, the mathematical modeling of wind farm which consists of turbine rotor, DFIG, rotor side and grid side converter and control systems is presented. In particular, the equation for dynamic modeling of the DFIG and the AC/DC/AC converter is expressed as dq reference frame. And then, on the basis of mathematical modeling for each component of wind farm, dynamic simulation algorithms for speed and pitch angle control of wind turbine and generated active and reactive power control of the DFIG and the AC/DC/AC converter are established. Finally, Using the MATLAB/SIMULINK, this paper presents dynamic simulation model for 6MW wind power generation systems with the DFIG considering distribution systems and performs the dynamic analysis of wind power systems in steady state. Moreover, this paper also presents the dynamic performance for the case when the voltage sag in grid source and phase fault in bus are occurred.

Comparative study of proportional-integral, proportional-resonant, and predictive deadbeat controllers in a PV PCS (태양광 전력변환장치의 PI, PR 및 PD 제어기 비교 연구)

  • Le, Dinh-Vuong;Kim, Chang-Soon;Hwang, Chul-Sang;Park, Minwon;Yu, In-Keun
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.1050-1051
    • /
    • 2015
  • In industry, there are several different controllers which can be implemented for power conditioning systems (PCS) such as proportional-resonant (PR), predictive deadbeat (PD), or proportional-integral (PI) controller. But there are not any comparison studies about these controllers. To investigate the differences between the three types of the controllers, this paper presents a comparative study of PR, PI, and PD controllers in a photovoltaic (PV) PCS. These controllers are designed mathematically and simulated for the comparative analysis. The PI controller is designed in the rotating reference (dq) frame. The PR and PD controllers are implemented in the natural (abc) reference frame. The PCS is composed of a DC-DC boost converter and a full bridge inverter. The filter of the PCS is an LCL filter including a passive damping resistor. The parameters of PCS are 3 kW, 25 kHz switching frequency and 220 V-60 Hz grid voltage. The comparison results between these controllers for the grid-connected PCS are clearly shown. The simulation results demonstrate the detailed characteristics of each controller for the PV PCS in order to choose the controller for individual target properly.

  • PDF

A Rejection of Harmonic Ripples for d-q Transformation (d-q 변환에서의 고조파 맥동 제거)

  • Choi, Nam-Yerl;Lee, Chi-Hwan
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.12
    • /
    • pp.83-87
    • /
    • 2015
  • This paper presents a simple notch filter, which is so suitable for three-phase unbalanced and distorted power line. In the d-q synchronous transformation, three-phase unbalanced and distorted voltages generate lots of ripple voltages on d-q axes. The ripples make disturbances on controllers such as PLL of phase tracking. Unbalanced state makes ripple of double the frequency of power line. Odd harmonics 5th and 7th on the line make even 4th and 6th ripples on d-q axes due to the rotating reference frame, respectively. Cascaded two comb filters, delay lines 1/4T and 1/8T, are adopted for the ripple rejection. The filter rejects harmonics 2nd, 4th, 6th, 10th and so on. They are very effective to remove the ripples of both unbalance and distortion. The filter, implemented by two FIFOs on an experimental system, is adopted on a PLL controller of power line phase tracking. Through the simulation and experimental results, performance of the proposed comb filter has been validated.

A Study of Inter-harmonic Control for the KSTAR Power System (KSTAR 전력계통 안정화를 위한 비정수 고조파 보상에 관한 연구)

  • Oh, Jeong-Cheol;Shin, Tae-Sung;Park, Byung-Ju;Yoo, Hang-Kyu;Hwang, An-Il;Kong, Jong-dae;Hong, Seong-lok
    • Proceedings of the KIPE Conference
    • /
    • 2015.07a
    • /
    • pp.467-468
    • /
    • 2015
  • 능동형필터는 주로 비선형 부하로 부터 발생되는 정수배의 고조파를 보상하는데 응용되어 왔다. 본 논문에서는 국가핵융합연구소(NFRI)의 KSTAR 주장치의 전원공급장치인 PF MPS가 가동되면서 특이한 저차수 대역의 비정수 고조파가 발생되는데 이는 MG(motor generator)와 RPC (Reactive Power Compensator)간의 병렬공진 확대현상으로 나타나 고조파 전류의 증가, 전압왜형 상승 등 안정적인 전력계통 운영에 영향을 주고 있다. 따라서 이의 원인이 되는 특이성의 비정수 고조파를 저감시키기 위한 제어 알고리즘 개발과 모의시험에 관한 연구내용을 다루고자한다. 지금까지 개발된 알고리즘은 주로 정수배 고조파만을 대상으로 한 FFT의 일괄보상, 혹은 개별차수 보상방식이었으나 여기서는 DQ 변환 알고리즘을 채용하여 정수배 고조파는 물론 0.5차 단위의 비정수 고조파까지 제어하는 기술을 다루었다.

  • PDF

PR Controller Based Current Control Scheme for Single-Phase Inter-Connected PV Inverter (PR제어기를 이용한 단상 계통 연계형 태양광 인버터 설계)

  • Vu, Trung-Kien;Seong, Se-Jin
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.12
    • /
    • pp.3587-3593
    • /
    • 2009
  • Nowadays, the PV systems have been focused on the interconnection between the power source and the grid. The PV inverter, either single-phase or three-phase, can be considered as the core of the whole system because of an important role in the grid-interconnecting operation. An important issue in the inverter control is the load current regulation. In the literature, the Proportional+Integral (PI) controller, normally used in the current-controlled Voltage Source Inverter (VSI), cannot be a satisfactory controller for an ac system because of the steady-sate error and the poor disturbance rejection, especially in high-frequency range. By comparison with the PI controller, the Proportional+Resonant (PR) controller can introduce an infinite gain at the fundamental ac frequency; hence can achieve the zero steady-state error without requiring the complex transformation and the dq-coupling technique. In this paper, a PR controller is designed and adopted for replacing the PI controller. Based on the theoretical analyses, the PR controller based control strategy is implemented in a 32-bit fixed-point TMS320F2812 DSP and evaluated in a 3kW experimental prototype Photovoltaic (PV) power conditioning system (PCS). Simulation and experimental results are shown to verify the performance of implemented control scheme in PV PCS.