• Title/Summary/Keyword: DPC

Search Result 184, Processing Time 0.027 seconds

Establishment and characterization of an immortalized human dermal papilla cell line

  • Shin, Seung-Hyun;Park, Sang-Yoon;Kim, Moon-Kyu;Kim, Jung-Chul;Sung, Young-Kwan
    • BMB Reports
    • /
    • v.44 no.8
    • /
    • pp.512-516
    • /
    • 2011
  • Establishment of immortalized human dermal papilla cells (DPCs) retaining the characteristics of DPCs would be a great help for hair researchers. We recently established a simian virus 40T (SV40T)-transformed human DP cell line (SV40TDPC). However, the cell line senesced around passage 25 and ceased proliferation. In this study, we introduced the human telomerase reverse transcriptase (hTERT) gene into SV40T-DPC and established an immortalized human DP cell line. The cell line, SV40T-hTERT-DPC, did not induce tumors when inoculated into nude mice. SV40T-hTERT-DPC maintained morphology of early passage DPCs, expressed markers of DPCs, and retained responses to Wnt/${\beta}$-catenin and bone morphogenic protein (BMP) signaling pathways known to be required for hair-inducing activity of DPCs. The data strongly suggest that SV40T-hTERT-DPC retains many characteristics of human DPCs in vivo without malignant transformation.

Automatic Command Mode Transition Strategy of Direct Power Control for PMSG MV Offshore Wind Turbines (자동 지령모드절환 기능을 갖춘 PMSG MV 해상 풍력 발전기의 직접전력제어 방법)

  • Kwon, Gookmin;Suh, Yongsug
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.21 no.3
    • /
    • pp.238-248
    • /
    • 2016
  • In this study, an automatic command mode transition strategy of direct power control (DPC) is proposed for permanent magnet synchronous generators (PMSGs) medium-voltage (MV) offshore wind turbines (WTs). Benchmarking against the control methods are performed based on a three-level neutral-point-clamped (NPC) back-to-back type voltage source converter (VSC). The ramping rate criterion of complex power is utilized to select the switching vector in DPC for a three-level NPC converter. With a grid command and an MPPT mode transition strategy, the proposed control method automatically controls the generated output power to satisfy a grid requirement from the hierarchical wind farm controller. The automatic command mode transition strategy of DPC is confirmed through PLECS simulations based on Matlab. The simulation result of the automatic mode transition strategy shows that the proposed control method of VOC and DPC achieves a much shorter transient time of generated output power than the conventional control methods of MPPT and VOC under a step response. The proposed control method helps provide a good dynamic performance for PMSGs MV offshore WTs, thereby generating high quality output power.

Light Scattering Studies on the Second CMC of the Aqueous Solution of Dodecyl Pyridinium Chloride and Tetradecyl Pyridinium Chloride (光散亂에 依한 Dodecyl Pyridinium Chloride 및 Tetradecyl Pyridinium Chloride 水溶液의 第二 CMC에 關한 硏究)

  • Moo Ill Chung;In Ja Tak;Kun Moo Lee
    • Journal of the Korean Chemical Society
    • /
    • v.19 no.6
    • /
    • pp.398-402
    • /
    • 1975
  • The light scattering studies of the aqueous solution of dodecyl pyridinium chloride (DPC) and tetradecyl pyridinium chloride (TPC) over the concentration range of 0~70 mM revealed that there exists a so-called 2nd critical micelle concentration (cmc) at about 43 mM and 8 mM respectively in addition to their 1st cmc at 17 mM and 3.5 mM. The 2nd cmc was greatly influenced by additives KCl, which lowered the 2nd cmc. The micelle molecular weight of DPC and TPC solutions at 1st cmc were 20800 and 15600 and the degree of ionization of their micelles at 1st cmc were 0.092 and 0.226 respectively.

  • PDF

Two Vector Based Direct Power Control of AC/DC Grid Connected Converters Using a Constant Switching Frequency

  • Mehdi, Adel;Reama, Abdellatif;Benalla, Hocine
    • Journal of Power Electronics
    • /
    • v.17 no.5
    • /
    • pp.1363-1371
    • /
    • 2017
  • In this paper, an improved Direct Power Control (DPC) algorithm is presented for grid connected three phase PWM rectifiers. The new DPC approach is based on two main tasks. First the optimization of the look-up table, which is well-known in conventional DPC, is outlined for selecting the optimum converter output voltage vectors. Secondly a very simple and effective method is used to directly calculate their duty cycles from the power errors. Therefore, the measured active and reactive powers are made to track their references using hysteresis controllers. Then two vectors are selected and applied during one control cycle to minimize both the active and reactive power ripples. The main advantages of this method are that there is no need of linear current controllers, coordinates transformations or modulators. In addition, the control strategy is able to operate at constant switching frequencies to ease the design of the power converter and the AC harmonic filter. The control exhibits a good steady state performance and improves the dynamic response without any overshoot in the line current. Theoretical principles of the proposed method are discussed. Both simulation and experimental results are presented to verify the performance and effectiveness of this control scheme.

Paired Many-to-Many Disjoint Path Covers in Recursive Circulants and Tori (재귀원형군과 토러스에서 쌍형 다대다 서로소인 경로 커버)

  • Kim, Eu-Sang;Park, Jung-Heum
    • Journal of KIISE:Computer Systems and Theory
    • /
    • v.36 no.1
    • /
    • pp.40-51
    • /
    • 2009
  • A paired many-to-many k-disjoint path cover (paired k-DPC) of a graph G is a set of k disjoint paths joining k distinct source-sink pairs in which each vertex of G is covered by a path. In this paper, we investigate disjoint path covers in recursive circulants G($cd^m$,d) with $d{\geq}3$ and tori, and show that provided the number of faulty elements (vertices and/or edges) is f or less, every nonbipartite recursive circulant and torus of degree $\delta$ has a paired k-DPC for any f and $k{\geq}1$ with $f+2k{\leq}{\delta}-1$.

Implementation for Real-Time of MIL-STD-1553B Communication in Inspection Equipment Based on Windows with RTiK and DPC Control (RTiK과 DPC 제어를 통한 윈도우즈 기반의 검사장비에서 MIL-STD-1553B 통신의 실시간 구현)

  • Kim, Jong-Jin;Lee, Sang-Gil;Lee, Cheol-Hoon
    • Journal of Korea Multimedia Society
    • /
    • v.24 no.2
    • /
    • pp.199-207
    • /
    • 2021
  • It is very important to support real-time on the inspection equipment based on Windows. In particular, in the system using MIL-STD-1553B communication, which is widely used in military weapon systems, real-time is required for inspection equipment that uses mostly platforms based on Windows such as Industrial PCs. However, in order to use a complete real-time operating system such as VxWorks, the purchase cost is expensive and the implementation is complicated on the system, so it is not suitable for inspection equipment that requires simple functions to just check go or no-go. Therefore, in this paper, a Real-Time implanted Kernel(RTiK) in the Windows kernel is implanted in order to improve these defects, and real-time performance is implemented for periodically MIL-STD-1553B communication by Deferred Procedure Call(DPC) of Windows. Also, it was verified that the period of up to 2ms was guaranteed with a RDTSC into the EDX:EAX registers for measuring the periodicity.

Autofocus Phase Compensation of Velocity Disturbed UUV by DPC Processing with Multiple-Receiver (다중 수신기 DPC 처리에 의한 속도 교란 수중 무인체의 자동초점 위상 보상)

  • Kim, Boo-il
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.21 no.10
    • /
    • pp.1973-1980
    • /
    • 2017
  • In the case of a small UUV operating an active synthetic aperture sonar, various velocity disturbances may occur on the path due to the influence of external underwater environment, and this causes phase errors in coherent synthetic aperture processing, which has a large influence on the detected image. In this paper, when a periodic sinusoidal velocity disturbance is generated in the traveling direction, the phase generated by the round trip slope range at each position is estimated the cross correlation coefficient for multiple received signals and compensated the position variation in the overlapped DPC by the average value within the maximum allowable width. Through simulations, it has been confirmed that the images degraded by the velocity disturbance amplitude and fluctuating frequency of the UUV are removed from the false targets and the performance of azimuth resolution is improved by the proposed phase compensation method.

Enrichment of Chromium(Ⅵ) by Macrorecticular DPC Resin (큰 그물 구조-DPC 수지에 의한 Cr(Ⅵ)의 농축)

  • In Hwa Woo;Tong Oh Seo;Kyu Ja Whang;Yong Keun Lee
    • Journal of the Korean Chemical Society
    • /
    • v.27 no.5
    • /
    • pp.345-352
    • /
    • 1983
  • Using a column of macrorecticular gel beads impregnated with alcohol solution of diphenylcarbarzide (DPC), the enrichment of Cr(Ⅵ) ion in 0.1M sulfuric acid was investigated. The column performance was compared with respect to the types of solid support such as Amberlite XAD and Diaion HP. Diaion HP-20 was found to be most suitable for this purpose. The break through point was increased when increasing the amount of DPC absorbed in the resin and the concentrated sample solution showed higher break through capacity than the dilute one. The extraction of Cr(Ⅵ) was not affected by the presence of 100 ppm Fe(Ⅲ) which amounted to ten times of 10 ppm Cr(Ⅵ) and the presence of other metal ions which amounted to 100 times of 10 ppm Cr(Ⅵ). Because the used gel particles were effectively regenerated with methanol, they were able to be used repeatedly.

  • PDF

Reduction of hexavalent chromium (Cr(VI)) under acidic conditions during its determination in cement (시멘트 6가 크롬 (Cr(VI))정량분석법에 관한 고찰 - 분석과정에서 Cr(VI) 의 환원에 따른 오차제어-)

  • Moon, Se-Heum;Jeong, Jae-Hong;Lee, Seung-Hoon;Lee, Seung-Heun
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.04a
    • /
    • pp.897-900
    • /
    • 2008
  • Some substances of cement could make underestimate concentration of hexavalent chromium(Cr(VI)) as they reduce Cr(VI) to Cr(III) in acidic condition during the determination of Cr(VI) content in cement. The reduction of Cr(VI) increased with elapsed time after acidification in this study. The reduction rate varied with various cements. From our result, we can conclude that simultaneous additions of acid and DPC were required for the accurate measurement of Cr(VI) in cement. The high recovery rate of 94.3 to 106.7% with the simultaneous acid-DPC addition method can also support our conclusion.

  • PDF

Distributed Constrained Power Control with Fast Outage Convegence in CDMA systems

  • Lee, Moo-Young;Oh, Do-Chang;Kwon, Woo-Hyen
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.2121-2125
    • /
    • 2003
  • This paper proposes a fast distributed constrained power control (FDCPC) with non-stationary relaxation factor to next power update in CDMA cellular power control system. We review unconstrained control algorithms, the distributed power control (DPC), unconstrained second order power control (USOPC) and DPC with stationary relaxation factor (DPCSRF). Under the unconstrained condition, the convergence analysis shows theoretically that the convergence rate of DPC is the fastest one. However, under the constrained control algorithms, DCPC is not the fastest one any more because of transmission power constraint. To improve the convergence speed, the DCPC with non-stationary relaxation factor (FDCPC) are proposed. Under the constrained condition, the convergence rate of FDCPC outperforms that of DCPC and CSOPC.

  • PDF