• Title/Summary/Keyword: DOORS

Search Result 596, Processing Time 0.031 seconds

A Study on the Evaluation of Thermal Transmittance Performance of Aluminum Alloy Window Frame of Educational Facility considering 2 Dimensional Steady-state Heat Transfer (2차원 정상상태 전열해석을 통한 교육시설의 알루미늄 창호 열관류율 평가에 관한 연구)

  • Park, Tong-So
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.11
    • /
    • pp.5284-5289
    • /
    • 2011
  • This study focused to evaluate thermal transmittance(U-value) performance of sliding type of aluminum alloy window frame(AAWF) with double glazing(DG) and glazing spacer and that without thermal breaker in winter and summer season by two dimensional steady state heat transfer analysis. The AAWE was installed to an existing educational facilities in Seosan area which is the southern region of the Korean Peninsula. Analysis of 2D steady-state heat transfer was performed through the use of BISCO as calculation and simulation program. U-value and temperature factors were calculated. The results are as followed. First, the isotherm simulation shows that AAWF with double glazing have serious differences from recently proposed window thermal performance standards such as Insulation Performance of Windows and Doors of Building Energy Saving Design Standards and the results of calculation of thermal transmittance performance of AAWF and DG are U=9.631 W/$m^2K$, U=2.382 W/$m^2K$ respectively during winter and summer season. Second, the results of analysis of heat transfer analysis, calculated by simulation, shows that 225% of heat is lost comparing with thermal performance standards U=4.0 W/$m^2K$ of general double glazing among those standards on AAWF without thermal breaker.

A Study on Smoke Extract Vents in a Subway with Screen door by Evacuation Performance Evaluation through RSET vs. ASET based on Computer Simulations (스크린도어가 설치된 지하철 승강장의 대피안전성 평가를 통한 제연환기구의 방재성능 개선방안 연구)

  • Park, Hyung-Joo;Lee, Young-Jae;Shin, Dong-Cheol;Baek, Dong-Ho
    • Journal of the Korean Society for Railway
    • /
    • v.10 no.5
    • /
    • pp.511-519
    • /
    • 2007
  • This study provides comprehensive design improvements covering technical issues concerning life safety matter In case of fire train stoppage in the middle of a tunnel. Recently Government announced that most of subway platforms will have screen doors in 3 years. Therefore, many fire safety engineers considered that they may contribute on life safety on train stoppage in tunnel. Especially The screen door can protect platform from smoke along tunnel ceiling when fire train stopped in tunnel. The study showed that platform ventilation ducts and the a tunnel ventilation chimney in the middle of tunnel in exiting subway tunnel could not guarantee life safety ability in terms of RSET vs. ASET comparison. Furthermore during evacuation process many peoples may be threatened from the smoke spread from the origin of fire. Although only additional vertical route can be installed in tunnels In order to decrease RSET, it will costs high or no spaces remains in outside on the road. The study suggested that increase of ASET can be best solution without additional escape route, therefore alternative design methods suggested on the base of simulation results. Finally the study shows alternative methods can give good result in terms of evacuation performance evaluation. The evacuation performance evaluation helps the decision-maker to determine the preferred alternatives or upgrades to existing tunnel infrastructure and other measure to meet safety objectives. Finally, the study details the effectiveness of measures the can be taken to reduce the risk of incidents in subway tunnels.

A study on the selection of the optimal smoke control mode in train platform through quantitative risk assessment (정량적 위험도 평가를 통한 열차 승강장 화재시 최적 제연모드 선정에 관한 연구)

  • Lee, Bo-Hoon;Hong, Seo-Hee;Baek, Doo-San;Lee, Ho-Hyung
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.24 no.6
    • /
    • pp.539-552
    • /
    • 2022
  • In the case of train stations, due to the specificity of underground spaces with limited smoke emissions, if appropriate removal equipment is not equipped, the damage caused by fire smoke may increase in the event of a fire. As a result, the need for measures to ensure the safety of evacuation of underground stations has been highlighted, and research for safe evacuation of platform users in case of fire is continuously being conducted at home and abroad. However, although the smoke removal area is currently divided by smoke boundary walls and platform screen doors (PSD) and installed in the train platform, standards for smoke removal methods (air supply or exhaust) for each fire removal area, that is, smoke removal mode, are not presented. In this study, fire analysis and evacuation analysis were performed to estimate the number of deaths and to derive F/N guidance in order to quantitatively evaluate the fire risk according to the fire station fire, and the total risk was the lowest in the case of fire area exhaust and supply to adjacent areas.

Smoke Control Experiment of a Very Deep Underground Station Where Platform Screens Doors are Installed - Analysis on Smoke Control Performance by Fans equipped in Tunnel (스크린도어가 설치된 대심도 지하역사의 제연 실험 - 터널 송풍기에 의한 제연의 효과 분석)

  • Park, Won-Hee;Kim, Chang-Yong;Cho, Youngmin
    • Asia-pacific Journal of Multimedia Services Convergent with Art, Humanities, and Sociology
    • /
    • v.9 no.9
    • /
    • pp.721-736
    • /
    • 2019
  • In this paper, the behavior of the fire smoke due to the operation of the ventilation systems when the fire occurred in the underground station (6 basement floors) and the tunnel at the great depth was measured. Fire smoke was generated by using a smoke generator which realized heat buoyancy effect by using hot air blower. The two locations of the fire were selected on the platform and on the platform of the tunnel located outside the screen door. A ventilation mode is generally used in which smoke is exhausted through a vent hole provided in a platform when a platform fire occurs. The tests were performed by operating the exhaust through the ventilation holes of the tunnel part located at both ends of the platform. The smoke density and the wind speed/velocity were measured at various positions, and the videos were taken to analyze the movement and smoke of the smoke. In both cases for fire inside the platform and in the railway tunnel, due to the ventilation mode operation of the fan for the platform and the exhaust of the fans in the tunnel smoke were well exhausted and the smoke propagation to the area near the smoke zone was suppressed. The smoke-control mode, which is applied to both fans for the platform and fans for in the tunnel at both ends of the platform, can provide a safer evacuation environment to the passengers from the fire smoke when the platform fire or fire train stops.

Development of AAB (Algorithm-Aided BIM) Based 3D Design Bases Management System in Nuclear Power Plant (Algorithm-Aided BIM 기반 원전 3차원 설계기준 관리시스템 개발)

  • Shin, Jaeseop
    • Korean Journal of Construction Engineering and Management
    • /
    • v.20 no.2
    • /
    • pp.28-36
    • /
    • 2019
  • The APR1400 (Advanced Power Reactor 1400MW) nuclear power plant is a large-scale national infrastructure facility with a total project cost of 8.6 trillion won and a project period of 10 years or more. The total project area is about 2.17 million square meters and consists of more than 20 buildings and structures. And the total number of drawings required for construction is about 65,000. In order to design such a large facility, it is important to establish a design standard that reflects the design intent and can increase conformity between documents (drawings). To this end, a design bases document (DBD) reflecting the design bases that extracted in regulatory requirements (e.g. 10CFR50, Korean Law, etc.) is created. However, although the design bases are important concepts that are a big framework for the whole design of the nuclear power plant, they are managed in 2-dimensional by the experts in each field fragmentarily. Therefore, in order to improve the usability of building information, we developed BIM(Building Information Model) based 3-dimensional design bases management system. For this purpose, the concept of design bases information layer (DBIL) was introduced. Through the simulation of developed system, design bases attribute and element data extraction for each DBIL was confirmed, and walls, floors, doors, and penetrations with DBIL were successfully extracted.

Measurement and evaluation of speech privacy in university office rooms (대학 내 사무실의 스피치 프라이버시 측정 및 평가)

  • Lim, Jae-Seop;Choi, Young-Ji
    • The Journal of the Acoustical Society of Korea
    • /
    • v.38 no.4
    • /
    • pp.396-405
    • /
    • 2019
  • The speech privacy of closed office rooms located in a university campus was measured and assessed in terms of SPC (Speech Privacy Class) values. The measurements of two quantities, the LD (Level Difference) between a source and a receiving room, and the background noise level ($L_b$) at the receiving room were carried out in 5 rooms located in 3 different buildings in the university campus. Each of the 5 rooms was adjacent to both offices and corridors through walls. The TL (Transmission Loss) between the source and the receiver room was also measured to compare the difference of two standard methods, ASTM E2836-10 and KS F 2809. The present results show that the speech privacy of the 5 office rooms is not met the requirement for a minimum SPC values of 70. A minimum LD value of 41 dB between the source and the receiver room should be achieved for having a SPC value of 70 when the mean measured value of $L_b$ at the receiving room is 29.2 dB. That is, the TL(avg) value averaged over the octave bands from 160 Hz to 5000 Hz between the source and the receiver room should be or greater than 40 dB. The most important architectural factor influencing the LD value is the presence of openings, such as doors, and windows, on the adjacent walls between the source and receiving room. Therefore, if the opening of the adjacent wall is replaced by an opening with high sound insulation, the appropriate SPC value of the research and office rooms can be achieved.

A Study on Survey Research Design Quality Indicators for the Educational Building - Focused on Teachers, School Personnel and Education Office Supervisor - (학교시설 디자인 품질지표에 대한 설문 연구 - 교사, 학교직원, 교육청담당자를 중심으로 -)

  • Cho, Kyung-Sik;Belyalova, Aigerim
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.25 no.5
    • /
    • pp.3-12
    • /
    • 2018
  • The purpose of this study is to examine the degree of appropriateness of using design quality indicators for the educational building, and complements for design quality indicators. For doing this, each items of the Korean educational building design indicator was validated by teachers, school staff and an education officer. First, School Personnel and Teachers considered indicators for the classroom designed for general subjects as being valid. However, in terms of indicators for the outside space, they thought of them as not being valid. In particular, it seemed that school staff would have a passive attitude toward the open of the school facility for the local society. It is judged that there happens an adverse effect caused by the open of the school facility for the local society in the educational environment of the school. Second, Education Office Supervisors thought that eco-friendly indicators, LED lighting, an outer wall, and widows and doors had a high validity. On the contrary, he viewed the validity of a rainwater retention basin as being low, which was likely because he rarely had expertise on the construction. When it comes to the indicator of technology capability, ultrahigh-speed information network was seen as being valid, and the indicator of economic feasibility had high validity on maintenance and durability. Third, compared to groups of Teachers and School Personnel, the group of education officers presented high validity of indicators. Validity of indicators might be differently showed because different items on indicators were measured. However, it is speculated that Education Office Supervisors mostly acknowledged the validity of indicators. Fourth, a majority of Teachers, School staff, and Education Office Supervisors were favor of the system of the evaluation accreditation for school facilities since it played a guide role in improving the quality of school. In order to settle the system of the evaluation accreditation for school facilities, it is most important that institutions in the local society which are publicly reliable should participate in the phase of designing the system of the evaluation accreditation for school facilities. In sum, overall respondents agreed with the system of the evaluation accreditation for school facilities but were aware that reliable organizations in public would need to take part in planning the system of the evaluation accreditation for school facilities from the beginning.

An Analysis of Dwelling Environment of Public Retirement(Silver) Housing Based on Post Occupancy Evaluation (거주 후 평가(P.O.E)에 의한 공공실버주택의 거주환경 분석)

  • Bak, Da-Hye;Kim, Young-Hwa;Lee, Sang-Hong
    • Journal of the Architectural Institute of Korea Planning & Design
    • /
    • v.34 no.12
    • /
    • pp.65-76
    • /
    • 2018
  • Due to the rapid demographic and structural changes, Korea has faced a variety of social issues and quickly entered the aged society since the 2000s. In order deal with this reality, diverse types of welfare policies are emerging in the society as a whole. The government began to supply domestic public silver housing in 2016 to provide against the quickly growing aged society and now, the government is planning to supply approximately 50,000 housing by 2022 for quantitative growth of aged society, by selecting 1st and 2nd designated areas for the project additionally. This public retirement(silver) housing combines 'space' with 'service'. The lower floors are a public silver welfare Facilities and the upper floors are a housing spaces. This type of housing is to deal with requirements of rental housing residents by combining physical space with supporting service. Based on barrier-free design, the complex and unit house have safety handles and alarm bells in the bathroom, undulating washstands, bathroom sliding doors, corridor safety handles, and emergency safety exit lamps in each housing unit so the aged and the disabled can use easily and conveniently. Also, hand rails are installed and stepped pulleys are removed to promote convenience. Currently, the government is planning to increase the supply, focusing on low-income groups, such as beneficiaries of national basic livelihood and the working poor. Recognizing that the public retirement(silver) housing project is at its early stage, this study examined satisfaction, based on evaluations of real residents. This study aimed to obtain more empirical research data and apply them to public retirement(silver) house space analysis. For analysis, this study targeted Wirye public retirement(silver) housing and Magnolia public retirement(silver) housing that are in operation, and literature review, previous research review, and field survey were conducted to examine the present state. Using the questionnaires consisting of four large classification items; Block Layout, Housing Unit, Welfare Facilities, and Barrier-free Design, and sub-details, a survey was conducted to analyze residents' satisfaction. In conclusion, it is anticipated that this study would serve as basic research data about public retirement(silver) housing to increase continuously in future by analyzing public retirement(silver) housing spaces, on the basis of the analyzed data.

Impacts of Minijob on Women's Employment in Germany (독일 미니잡이 여성 고용에 미친 영향)

  • Kang, Su-Dol
    • Korean Journal of Labor Studies
    • /
    • v.23 no.2
    • /
    • pp.277-306
    • /
    • 2017
  • This article empirically explores the impact of minijobs in the wake of the Hartz reform in Germany on women's employment relationship. Theoretically it is of great significance to examine whether the minijobs play an active role as a bridge in leading the minijobbers to regular, socially secured jobs or not. Several interviews as well as secondary data I could get during my sabbatical in 2015 were used to test the theory. One of the main findings was the fact that the minijob labor market opened doors wide for women in Germany, particularly for career-interrupted women, students or pensioners. However, the minijob can easily become a trap of lowest income and poverty for women. Most women minjobbers cannot go over to regular, socially secured jobs. Especially in terms of collective industrial relations, it considerably damages the power of industrial unions and the legal binding force of collective agreement. In conclusion, this study makes it clear that the labor market segmentation theory rather than the transitional labor market theory is valid in accounting for the reality of minijob in Germany. In other words, the minijob in Germany has a Toijan Horse Effect. It also suggests, from a practical viewpoint, that German industrial unions or works councils organize the minijobbers and that the coverage of collective agreements be extended to the minijobbers. Consequently, the time-selective part-timer model put into practice in Korea in 2014 is not only invalid but also undesirable.

Evaluation of Electromagnetic Pulse Shielding Effectiveness and Bonding Performance of Inorganic Paint based on Carbon Material (탄소재료 기반 무기계 도료의 전자파 차폐성능 및 부착성능 평가)

  • Jang, Kyong-Pil;Kim, Sang-Hee
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.1
    • /
    • pp.801-807
    • /
    • 2021
  • In various industrial fields and infrastructure based on electronic components, such as communication equipment, transportation, computer networks, and military equipment, the need for electromagnetic pulse shielding has increased. Two methods for applying electromagnetic pulse shielding are effective. The first is construction using shielding materials, such as shielding concrete, shielding doors, and shielding windows. The other is coating shielding paints on non-shielding structures. Electromagnetic pulse shielding paints are made using conductive materials, such as carbon nanotubes, graphite, carbon black, and carbon fiber. In this paint, electromagnetic pulse shielding performance is added to the commonly used water-based paint. In this study, the shielding effectiveness and bonding performance of paints using conductive graphite and carbon black as shielding materials were evaluated to develop electromagnetic pulse shielding inorganic paints. The shielding effectiveness and bonding performance were evaluated by applying six mixtures composed of different kinds and amounts of shielding material. The mixture of conductive graphite and carbon black at a weight ratio of 1:0.2 was the most effective in shielding as 33.6 dB. Furthermore, the mixture produced using conductive graphite only showed the highest bonding performance of 1.06 MPa.