Study of Smoke Behavior and Differential Pressure in the Refuge Safety Area According to Damper Capacity of Smoke Control (제연댐퍼 송풍량에 따른 피난 안전 구역 차압 및 연기 거동 특성 연구)

  • Lee, Jae-Bin;Moon, Joo-Hyun;Lee, Seong-Hyuk;Ryou, Hong-Sun
    • Fire Science and Engineering
    • /
    • v.25 no.4
    • /
    • pp.103-109
    • /
    • 2011
  • In this study, we calculated the smoke movement at the fire area of the refuge floor which has the refuge safety area in case of fire in the high rise building by using a computational fluid dynamics (CFD) code of FLUENT (ver. 13.0). The buoyancy plume was applied using the temperature and flow velocity which represent 10 MW heat release rate in order to describe the fire, and the smoke movement was predicted using a species conservation equation. The pressurization system of smoke control was adopted with smoke control damper in refuge safety area, at the result, it is confirmed that the damper capacity was enough to smoke control in which the flow rate of supply was applied 25 $m^3/s$ in the case of the door at fire area opened only, and 50 $m^3/s$ in the doors at the fire area and lobby both opened case. They were satisfied in NFSC 501-A. Even though the door of fire area closed, there were smoke leakages at the gap between the door and wall. In addition, the refugee could be isolated in the fire area when the door of fire area closed during smoke control in the case of using the high damper flow rate of supply, 50 $m^3/s$. Therefore the proper damper flow rate of supply are needed in order to prevent the damage of refugee and this study proposes the suitable condition of damper capacity according to refuge scenario.

Forecast study for active factor of V2B(Vehicle to Building) operation zero energy building using monte carlo method (몬테카를로방법을 이용한 V2B(Vehicle to Building) 운용 제로에너지빌딩의 액티브 요소 예측 연구)

  • Kim, Youngil;Kim, Insoo
    • Journal of Energy Engineering
    • /
    • v.26 no.4
    • /
    • pp.29-34
    • /
    • 2017
  • Factors of Zero-Energy Building are divided into active and passive factor. Passive factor means insulation, heat bridge of building like insulation, windows and doors, awning, outside etc. and active factor means energy output and efficiency coefficient. Energy output of active factor is achieved by new generating energy. This study anticipated how many effects will be produced when not new generating energy but Vehicle to Building; V2B, bi-directional charging and discharging technology, is applied to Zero-Energy Building. In new generating energy, power generation will be anticipated by geography and climate, but in V2B, several input variable like user's discharging intention and number of usable charger etc. should be considered. We can check how much V2B contribute to the Zero-Energy Building by anticipated results, and that results should be anticipated by using probabilitic method because there is few statistical data. This study anticipate change of charging and discharging pattern, based by Demand Response slot, by using monte carlo method among the probabilitic methods.

A Study on the Original State of the Buildings in NakSunJae Area (낙선제(樂善齊) 일곽(一廓) 건축(建築)의 조영(造營)에 관한 복원적(復元的) 고찰(考察))

  • Noh, Jin-Ha;Lee, Sang-Hae
    • Journal of architectural history
    • /
    • v.4 no.1
    • /
    • pp.43-70
    • /
    • 1995
  • This paper aims to clarify the historical background and the architectural purpose of the buildings in NakSunJae area to the original state. Through the investigation, the clarified facts are as follows. 1. The relation with the buildings for the Crown Prince in the ChangDok Palace By constructing buildings in the NakSunJae area, the spatial conception of the Royal Palace was changed, that is, buildings for the Crown Prince in the ChangDok Palace disappeared and they became to belong to the ChangGyeong Palace. Moreover, by constructing the NakSunJae and its attached buildings, the area for the Crown Prince shifted to use as a private area for the king. 2. The date and the purpose of the construction The NakSunJae area is consisted of three compounds of building: NakSunJae, SukBokHun and SooKangJae. The NakSunJae was constructed for the king HunChong's private occupancy in 1847 and the SukBokHun for a residence of a royal concubine Kim, in 1847. The SooKangJae was originally built in 1785 in the SooKang Palace where the ex-king took up as his residence after abdicate the throne. Later on, it was repaired as the residence of the Queen SoonWon, king HunChong's grandmother, in commemoration for the 60th anniversary of her birth in 1848. 3. Architectural features of the NakSunJae area at the time of construction First, as the NakSunJae area is surrounded by quite high hills in northeast and by low hills in southwest, it is naturally distinguished from its surroundings and gives a cosy feeling. Second, the NakSunJae area shows very untrammeled style of arrangement in general, because it was constructed as a private occupancy for the king. other buildings are arranged in the latticing orderly, nonetheless, they are free by themselves from a strict form and make themselves an area full of variety. Third, the buildings in the NakSunJae area have a characteristic of naivety of common people's houses, because they were not an official but private place for the king, his concubine and his grandmother. Forth, the ornaments in the NakSunJae area are variously, elegantly and harmoniously patterned with the meaning of good luck. Fifth, back garden in the NakSunJae area was made by taking advantage of sloping hills. The back garden is beautifully configurated by arranging various constituent elements of pavilions, tiered flower beds, chimneys, decorated walls, small doors between walls, stoneworks and trees.

  • PDF

Development of Door Control Unit for the Electric Plug-in Door of Subway Train (전동차 전기식 플러그도어 출입문 제어 장치 개발)

  • Joung, Eui-Jin
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.48 no.4
    • /
    • pp.47-53
    • /
    • 2011
  • The Electric Multiple Unit (EMU) has many types of door system such as sliding door, plug door etc.al. according to customer's requirements. The sliding door is widely used in Korea but has weak point in the noise problem. In the low operation speed, the noise coming from outer side of the EMU is not an important factor. As the speed is higher than before, noise is increased and make a problem. The main cause of noise is the imperfect air tightness in the EMU. The plug door system has advantages for the noise reduction characteristic in the high speed area. We have been developing electric plug-in door. The door is controlled by Door Control Unit(DCU) following the order of Automatic Train Protection (ATP) that is a kind of train signalling system. DCU has to simultaneously open and close the doors and the operation of it is related to the passengers safety. So DCU is a safety device that is important to reliability and safety. DCU is composed of several devices of control, motor driving, Input/Output, communication and power. In this paper, we will describe the functions, characteristic, requirement, subsystem and test results of DCU used for the electric plug-in door.

Barrier Free Accessibility to Trains for All

  • Rentzsch, Manfred;Seliger, Denis;Meissner, Thomas;Wessner, Claudia
    • International Journal of Railway
    • /
    • v.1 no.4
    • /
    • pp.143-148
    • /
    • 2008
  • This paper is the output of a collaborative European project concerning the barrier free accessibility for disabled persons to regional and long distance trains in Europe. Disabled people represent around 13% of the population in Europe. This is approximately 63 million people. The range of disabilities includes people with reduced mobility including wheel chair users, viewing and hearing impaired people and other forms of impairment. Improving accessibility aims at contributing to the provision of public transport services to all citizens in an equitable way. The purpose of the project was to analyse and to evaluate the existing solutions at selected European railways for all required modules at the entrance (doors, information and safety solutions), to derive a design concept, to develop a mock-up in meeting the needs of rail travellers with the above mentioned impairments and to test it with user groups. The project also aims at deriving components for the determination of standards. The EUPAX Design Mock-up test was performed to verify the advantages of the layout of the train segment including the different modules such as access area (including the access door, gaps between platform and train as well as boarding aid devices), entrance vestibule, information systems inside and outside the train, emergency facilities, toilet with all conveniences and the additional test arrangements regarding push buttons, steps and emergency equipment. For this purpose a questionnaire was developed for the assessment of the EUPAX segment and the additional test arrangements. With the help of this questionnaire it was possible to execute a quantitative and qualitative evaluation. During three test phases 67 experts and handicapped persons from 6 countries have evaluated the Industrial Design mock-up based on this questionnaire. The test group covered persons from North (Denmark) to the South (Italy) and from the West (Spain) to the Middle of Europe (Germany). This is especially important for the generalization (harmonisation) of the results for all European countries. According to COST 335 the information for people with reduced mobility should be clear, concise, accurate and timely. So that all information can be received from persons, they must be transferred on at least two of the three possible ways (acoustical, visual, tactile), a so called "2-sense-principle". Based on the results ergonomic specifications/ solutions for the ergonomic design of the access area, the acoustic, visual and tactile information and the emergency devices including the emergency communication system were developed, related to the benefiting passenger groups.

  • PDF

Reliability Analysis of Access Door Opening Force Measured with a Digital Force Gauge of a Pressurized Smoke Control Zone and Presentation of Optimum Conditions for the Opening Force (디지털 측정기로 측정된 급기가압 제연구역의 출입문 개방력에 대한 신뢰성 분석 및 최적 조건 제시)

  • Lee, Jae-Ou;Choi, Chung-Seog
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.1
    • /
    • pp.468-473
    • /
    • 2016
  • The aim of this study was to measure the opening force of an access door of a pressurized smoke control zone and verify the reliability of the opening force. For the access door opening force, the opening load of the access door was measured before and after pressurized air had entered the smoke control zone. The reliability of the measured values was verified using the Anderson Darling's statistical analysis method of the Minitab Program. Because the analyzed P values were greater than 0.05 except for some floors before and after the operation of the smoke control equipment, the opening force was found to have 95% reliability. The normal distribution of the measured values showed no relationship with the operation of the smoke control equipment and the precision of the force gauge was believed to be reliable. The major factors for the optimal design of the pressurized smoke control equipment include the precision and reliability of the force gauge, the correct posture of the measuring person, and the same conditions for access doors. Therefore, a digital force gauge is believed to be suitable for measuring the opening force of the access door of a pressurized smoke control zone. In addition, standardization of the posture of a measuring person, the setup of the initial opening force of an access door, etc., are major variables for effective measurements of the door opening force of an access door.

Study on the optimal design of floor exhaust system using computational fluid dynamics for subway platform (수치해석을 활용한 승강장 바닥배기 시스템 최적화 연구)

  • Namgung, Hyeong-Gyu;Park, Sechan;Kim, Minhae;Kim, Soo-Yeon;Kwon, Soon-Bark
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.2
    • /
    • pp.443-449
    • /
    • 2017
  • The imbalance of air supply and the exhaust on subway platforms has led to the installation of platform screen doors in underground subway stations. This imbalance causes the accumulation of pollutants on the platform and loss of comfort due to the lack of ventilation. In this study, a floor exhaust system was optimized using computational fluid dynamics (CFD) and an optimization program. The optimized floor exhaust system was manufactured and tested experimentally to evaluate the particle collection efficiency. CFX 17.0 and HEEDS were used to analyze the flow field and optimize the principal dimensions of the exhaust system. As a result of the three-step optimization, the optimized floor exhaust system had a total height of 1.78 m, pressure drop of 430 Pa, and particle collection capability of 61%. A fine dust particle collection experiment was conducted using a floor exhaust system that was manufactured at full scale based on the optimized design. The experiment indicated about 65% particle collection efficiency. Therefore, the optimized design can be applied to subway platforms to draw in exhaust air and remove particulate matter at the same time.

Fire Alarm Sound Transmission in Apartment Units (공동주택에서의 화재경보음 전달)

  • Jeong, Jeong-Ho
    • Fire Science and Engineering
    • /
    • v.32 no.3
    • /
    • pp.67-75
    • /
    • 2018
  • To reduce the number of casualties in the case of fire, an alarm sound needs to be delivered to the people who remain in the apartment unit. On the other hand, it was reported that the fire alarm sound generated in the elevator hall was not delivered sufficiently to the people staying in the apartment units. In this study, the background noise level and noise level generated in an apartment unit were measured during the day and night time. In addition, the transmission of the fire alarm sound into the each room of apartment units was simulated and compared with the background noise level. The fire alarm sound generated in the elevator halls was reduced by the fire door and doors, and was not transmitted sufficiently into the internal spaces of the apartment units. Starting evacuation action was difficult after hearing the fire alarm sound generated outside the apartment units. To improve the transmission of an alarm sound to the inner spaces of apartment units, an acoustic simulation was carried out for cases where the alarm sound generator was installed on a wall-pad in the living room and the alarm sound generator was installed on the ceiling of each rooms in apartment units. Background noise of + 15 dB and 75 dB (A) were satisfied when alarm sound generator was installed on the ceiling of each room.

A Study on the Evaluation of Thermal Transmittance Performance of Aluminum Alloy Window Frame of Educational Facility considering 2 Dimensional Steady-state Heat Transfer (2차원 정상상태 전열해석을 통한 교육시설의 알루미늄 창호 열관류율 평가에 관한 연구)

  • Park, Tong-So
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.11
    • /
    • pp.5284-5289
    • /
    • 2011
  • This study focused to evaluate thermal transmittance(U-value) performance of sliding type of aluminum alloy window frame(AAWF) with double glazing(DG) and glazing spacer and that without thermal breaker in winter and summer season by two dimensional steady state heat transfer analysis. The AAWE was installed to an existing educational facilities in Seosan area which is the southern region of the Korean Peninsula. Analysis of 2D steady-state heat transfer was performed through the use of BISCO as calculation and simulation program. U-value and temperature factors were calculated. The results are as followed. First, the isotherm simulation shows that AAWF with double glazing have serious differences from recently proposed window thermal performance standards such as Insulation Performance of Windows and Doors of Building Energy Saving Design Standards and the results of calculation of thermal transmittance performance of AAWF and DG are U=9.631 W/$m^2K$, U=2.382 W/$m^2K$ respectively during winter and summer season. Second, the results of analysis of heat transfer analysis, calculated by simulation, shows that 225% of heat is lost comparing with thermal performance standards U=4.0 W/$m^2K$ of general double glazing among those standards on AAWF without thermal breaker.

A Study on Smoke Extract Vents in a Subway with Screen door by Evacuation Performance Evaluation through RSET vs. ASET based on Computer Simulations (스크린도어가 설치된 지하철 승강장의 대피안전성 평가를 통한 제연환기구의 방재성능 개선방안 연구)

  • Park, Hyung-Joo;Lee, Young-Jae;Shin, Dong-Cheol;Baek, Dong-Ho
    • Journal of the Korean Society for Railway
    • /
    • v.10 no.5
    • /
    • pp.511-519
    • /
    • 2007
  • This study provides comprehensive design improvements covering technical issues concerning life safety matter In case of fire train stoppage in the middle of a tunnel. Recently Government announced that most of subway platforms will have screen doors in 3 years. Therefore, many fire safety engineers considered that they may contribute on life safety on train stoppage in tunnel. Especially The screen door can protect platform from smoke along tunnel ceiling when fire train stopped in tunnel. The study showed that platform ventilation ducts and the a tunnel ventilation chimney in the middle of tunnel in exiting subway tunnel could not guarantee life safety ability in terms of RSET vs. ASET comparison. Furthermore during evacuation process many peoples may be threatened from the smoke spread from the origin of fire. Although only additional vertical route can be installed in tunnels In order to decrease RSET, it will costs high or no spaces remains in outside on the road. The study suggested that increase of ASET can be best solution without additional escape route, therefore alternative design methods suggested on the base of simulation results. Finally the study shows alternative methods can give good result in terms of evacuation performance evaluation. The evacuation performance evaluation helps the decision-maker to determine the preferred alternatives or upgrades to existing tunnel infrastructure and other measure to meet safety objectives. Finally, the study details the effectiveness of measures the can be taken to reduce the risk of incidents in subway tunnels.