• Title/Summary/Keyword: DMA

Search Result 496, Processing Time 0.049 seconds

Carbon dioxide absorption characteristics according to amine mixtures with different order (급수가 다른 아민 혼합에 따른 이산화탄소 흡수 특성)

  • Choi, Soo-Hyun;You, Jong-Kyun;Park, Ki-Tae;Baek, Il-Hyun;Park, So-Jin
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.9
    • /
    • pp.4635-4642
    • /
    • 2013
  • The advanced absorbent that used amine mixture with different order were developed to separate carbon dioxide emitted from fossil fuel power plant. The carbon dioxide absorption capacity for mixtures with different amine(primary, secondary and tertiary) were investigated according to $CO_2$ partial pressure. The carbon dioxide absorption capacity at the same pressure is ordered as 3DMA1P 30wt%>3DMA1P 27wt%+MEA 3wt%>3DMA1P 27wt%+DEA 3wt%. The result indicates that mixing tertiary amine with primary amine yields more efficient carbon dioxide absorbent than mixing tertiary with secondary amine does. Finally, the predicted semi-empirical gas-liquid equilibrium model fitted with experimental results.

Analysis of Dimethylamine and Trimethylamine in Fishes by Gas Chromatography

  • Oh, Myung-Cheol;Oh, Chang-Kyung;Kim, Sung-Hong;Kim, Soo-Hyun
    • Preventive Nutrition and Food Science
    • /
    • v.2 no.3
    • /
    • pp.197-201
    • /
    • 1997
  • To develop a rapid analytical method of dimethylamine(DMA) and trimethylamine(TMA) in fish, the contents of DMA and TMA in squid(Illex illecebrosus and Sepiell maindroni), cod(Gadus marcrocephalus) and plaice (Paralichthys olivaceus) by gas chromatographic (GC) and colorimetric method were determined. Recoveries for DMA in fish were 86.8~102.5% by GC and 74.2~94.5% by colorimetric method, while those for TMA were 93.0~101.1% by GC and 62.9~117.5% by colorimetric method. The contents of DMA and TMA in fish by GC were 29.7~325.3mg/kg and 145.6~356.0 mg/kg, respectively, and these by colorimetric method were 20.0~241.2mg/kg and 139.1~304.3mg/kg, respectively. The analysis of DMA and TMA in fishes by GC after the solvent extraction was simpler and faster and showed better recovery than colorimetric method.

  • PDF

Recent Development of Differential Mobility Analyzers For Size-Classification of Nanoparticles and Their Applications to Nanotechnologies

  • Seol, Kwang-Soo;Yoshimichi Ohki;Kazuo Takeuchi
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • v.4C no.2
    • /
    • pp.39-44
    • /
    • 2004
  • The present paper gives a review of the recent development of a differential mobility analyzer (DMA) available for both particle size measurements and production of monodisperse particles in the nanometer range. Operating principles of a general DMA are introduced as well as characteristics of highly functional DMAs such as those capable of classifying particles in a measurement range as broad as 1-1000nm at low pressures. Some examples of DMA applications are also described.

Water loss Control in DMA Monitoring System Used Wireless Technology

  • Malithong, P.;Gulphanich, S.;Suesut, T.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.773-777
    • /
    • 2005
  • This article is about using information technology to apply with water loss inspection system in District Metering Area (DMA). Inspector can check Flow rate and Minimum Night Flow; NMF via Smart Phone or PDA include sending SMS Alert in case the Pressure, Flow rate and NMF is over the range of controlling. This will be used as equipment to implement water loss in international proactive and can keep on water loss reduction more efficiency. The system consists of Data Logger which collects data of Flow rate from DMA Master Meter. PC is Wap Server which dial via modem in order to get data through FTP Protocal that will convert text file to Microsoft Access Database. Wappage will use xhtml language to show database on Wapbrowser and can show the result on Smart Phone or PDA by graph and table for system analysis.

  • PDF

Optimal design methodology of district metered area utilizing Geographic Information System (GIS를 이용한 상수관망 소블록 최적설계기법 개발)

  • Kim, Kyoung-Pil;Park, Yong-Gyun;Koo, Ja-Yong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.29 no.2
    • /
    • pp.223-231
    • /
    • 2015
  • District Metered Area (DMA) construction is one of the most cost effective alternatives for management of water loss (i.e., water leakage) and energy consumption (i.e., water pressure) in water distribution systems. Therefore, it's being implemented to numerous new and existing water distribution systems worldwide. However, due to the complexity of water distribution systems, especially large-scale and highly looped systems, it is still very difficult to define the optimal boundary of DMAs considering all the aspects of water distribution system management requirements. In this study, a DMA design methodology (or a DMA design model) was developed with Geographic Information Systems (GIS) and hydraulic distribution system model to determine the optimal DMA boundary.

비소종(Arsenite, Arsenate, DMA)에 따른 토양독성 비교분석

  • Lee U-Mi;Lee Ju-Yeong;Im Seung-Yun;Jeong Hye-Won;An Yun-Ju
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2005.04a
    • /
    • pp.175-177
    • /
    • 2005
  • Effect of arsenite, arsenate and dimethylarsinic acid (DMA) on the growth of seedling plants were investigated in order to compare the toxicity of arsenic species in soil environments. Test plants were mung bean (Phaseolus radiatus), wheat (Triticum aestivum), barely (Hordeum vulgare), cucumber (Cucumis sativus L.). Seedling growth in As-contaminated soil were significantly reduced in all test species. Arsenite was more toxic than arsenate and DMA. Among the test plants, mung bean was most sensitive to arsenic, followed by cucumber, wheat, and barely.

  • PDF

Efficiency Improvement of Digital Protective Relay for Power Transformer Using DMA Controller of DSP (DSP의 DMA 제어기를 이용한 변압기용 디지털 보호계전기의 성능향상)

  • 권기백;서희석;신명철
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.52 no.11
    • /
    • pp.647-654
    • /
    • 2003
  • As electrical power system has become complicated and enlarged to cope with the increasing electric demand, it has to be expected that higher speed, higher reliability, higher function and higher arithmetic ability in protective relay should be realized. Therefore, in this papers, by hardware design and implementation used DMA controller that transfer blocks of data to any location in the memory map without interfering with CPU operation, CPU utilization is increased effectively, as a result it made possible to implement multi-function digital protective relay which has high trust and high function of protection as well as control and metering for power transformers using single processor(DSP).

Memory Access Tracing for Device DMA operations using Full System Emulator (Full System Emulator를 사용한 디바이스 DMA 동작의 메모리 접근 추적기법)

  • Jang, Ikjoon
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2012.11a
    • /
    • pp.75-78
    • /
    • 2012
  • 디바이스 드라이버의 결함은 시스템 실패의 주요 원인이다. 임베디드 디바이스 드라이버는 세심히 검증되어야 하지만, 디바이스 드라이버는 디바이스 동작에 큰 연관이 있기 때문에 단독으로 검증하기 어렵다. 비동기적인 디바이스의 DMA 동작들은 보통 복잡한 구조를 가질 수 있으며 비결정적인 조건상에서 발생하는 문제가 있을 경우 재현하기가 매우 어렵다. 이러한 관점에서, 실제와 동일한 인터페이스를 가지고 있는 가상 디바이스를 사용하게 되면, 코드의 변경 없이 디바이스 내부 상태 변화를 관찰 할 수 있다. 본 논문에서는 가상 디바이스를 활용하여 DMA 동작과 CPU 의 메모리 접근간의 충돌을 감시할 수 있는 방법을 제시한다. 가상 임베디드 시스템을 QEMU full system emulator 상에서 동작시키고, CPU 와 가상디바이스의 시스템 버스에 대한 메모리 접근을 추적하는 기능을 개발하였다.

Study on the real-time measurement equipment for nanoparticle in low-pressure processes (저압공정 중 발생하는 나노입자 실시간 측정장비에 관한 연구)

  • Na, Jeong-Gil;Cho, Dae-Geun;Choi, Jae-Boong;Kim, Young-Gin;Kim, Tae-Sung
    • Journal of the Korean Vacuum Society
    • /
    • v.16 no.6
    • /
    • pp.468-473
    • /
    • 2007
  • In this paper, we discussed about the development of the PBMS(Particle Beam Mass Spectrometer) that can measure the nanoparticles on real-time in low-pressure processes. To calibrate this equipment, a DMA(Differential Mobility Analyzer) was used to generate NaCl particles which are charged to +1. Total aerosols flow rate was 1 lpm and 0.086 lpm of that was introduced into the PBMS through the pressure-reducing critical orifice. Transport efficiency through PBMS was 50$\sim$60 % compared to particle current for DMA and PBMS according to the particle size. Results of mesurements are in good agreement with size distributions obtained by DMA.