• Title/Summary/Keyword: DLMS/COSEM protocol

Search Result 4, Processing Time 0.016 seconds

Implementation and Performance Evaluation of the Smart Meter Concentrator Control Protocol for Advanced Metering Infrastructure (차세대 검침 기반구조를 위한 스마트 미터 집중기 제어 프로토콜의 구현과 성능분석)

  • Jang, Soon-Gun;Choi, In-Ji;Park, Byoung-Seok;Kim, Young-Hyun;Yoon, Chong-Ho
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.48 no.3
    • /
    • pp.41-49
    • /
    • 2011
  • In this paper, we propose an open protocol to be employed between a smart meter concentrator and a metering data collection server, and also evaluate its performance. Legacy concentrators performs the connection establishment and data gathering operations with DLMS/COSEM protocol standards. However, we note that there are no standardized protocols between the concentrator and the collection server, which inevitably conduces each commercial smart metering system to have its own proprietary protocol. In order to solve this problem, we propose an open protocol - Smart Meter Concentrator Control Protocol(SMCCP) by extending the existing standard protocol(DLMS/COSEM). The SMCCP can provide the proxy mode to enable efficient transmission between the concentrator and the data collection server. It also can support the relay mode to enable a direct communication between the data collection server and each far end smart meter. We also implement an emulator system and a protocol analyzer to provide its operation. In addition, we evaluate the session holding time and the link usage ratio in both relay and proxy modes with OMNET++ simulator.

The Integrated SCADA Data Gateway Platform based on SmartGrid (스마트 그리드 기반 통합 SCADA Data Gateway 플랫폼)

  • Song, Byung-Kwen
    • Journal of IKEEE
    • /
    • v.18 no.1
    • /
    • pp.140-145
    • /
    • 2014
  • OPC UA(IEC62541) is a communication protocol for SG(Smart Grid) application platform. It was standardized by IEC TC57 group in December 2012. The IEC61850 has been used in Digital Substation Systems and Smart Distributed Systems. The DNP3.0 has been used for device's data collection/control in Distributed Systems. The DLMS/COSEM has been used to control metering and collect information in the Smart Metering. The top-level SG management platform needs an independent middleware to manage transparently the Power Information Technology, including the IEC61850, DNP3.0, DLMS/COSEM. In this paper, we propose the SDG(Scada Data Gateway) platform. It manages Power Information Technology based Digital Substation Systems and Smart Distributed systems, Smart Metering through OPC UA.

DLMS Traffic Monitoring System base on HDLC Protocol (HDLC 프로토콜 기반 DLMS 트래픽 모니터링 시스템)

  • Song, Byung-Kwon;Kim, Sae-Byuk;Kim, Kyeong-Hun;Jeong, Tae-Eui;Kim, Jin-Cheol;Kim, Yeong-Eok
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2008.06d
    • /
    • pp.491-494
    • /
    • 2008
  • 기존의 전력량계의 원격 검침을 위한 DLMS/COSEM(Device Languag Message Specification / Companion Specification for Energy Meters) 시스템에서의 실제 송, 수신되는 데이터를 수집하여 이를 표현 및 분석 할 수 있는 프로그램을 구현하여 이로 하여금 실제 검침원에게 시스템에서의 송 수신되는 데이터의 흐름을 한 눈에 볼 수 있게 하였다. 또한 데이터의 실제 값 들을 분석하여 이틀을 가시적으로 볼 수 있어 오류 발생 시에 세부적으로 데이터를 분석하여 오류 원인을 찾아 낼 수 있다.

  • PDF

Data Interworking Model Between DLMS and LwM2M Protocol (DLMS와 LwM2M 프로토콜 간 데이터 연동 모델 연구)

  • Myoung, Nogil;Park, Myunghye;Kim, Younghyun;Kang, Donghoon;Eun, Changsoo
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.6 no.1
    • /
    • pp.29-33
    • /
    • 2020
  • Despite the same system architecture and operation principle, Advanced Metering Infrastructure (AMI) and Internet of Things (IoT) are recognized as a heterogeneous system. This is due to the different object modeling and communication protocols used in smart meters and sensors. However, data interworking between AMI and IoT is expected to be inevitable in the future. In this paper, we propose Device Language Message Specification (DLMS) to Lightweight Machine to Machine (LwM2M) conversion model. The proposed interworking model can reduce the packet size by 46.5% compared to that of the encapsulation method.