• Title/Summary/Keyword: DCM Analysis

Search Result 105, Processing Time 0.03 seconds

Numerical analysis of center cracked orthotropic fgm plate: Crack and material axes differ by θ°

  • Kaman, Mete Onur;Cetisli, Fatih
    • Steel and Composite Structures
    • /
    • v.13 no.2
    • /
    • pp.187-206
    • /
    • 2012
  • In this study, fracture analysis of orthotropic FGM (Functionally Graded Material) plate having center crack is performed, numerically. Material axis arbitrarily oriented and there is an angle ${\theta}^{\circ}$ between material and crack axes. Stress intensity factors at the crack tips for Mode I are calculated using Displacement Correlation Method (DCM). In numerical analysis, effects of material properties and variation of angle ${\theta}^{\circ}$ between material and crack axes on the fracture behavior are investigated for four different boundary conditions. Consequently, it is found that the effect of ${\theta}^{\circ}$ on stress intensity factor depends on variation of material properties.

Estimation of Inelastic Response for Building Structure by Analysis Method (해석방법에 따른 빌딩구조물의 비탄성 응답 평가)

  • Chang, Dong-Hui;Song, Jong-Keol;Chung, Yeong-Hwa
    • Journal of Industrial Technology
    • /
    • v.25 no.A
    • /
    • pp.31-38
    • /
    • 2005
  • Recent earthquakes have shown that near-field earthquakes can produce spectral demands significantly larger than those considered in current design code. International Atomic Energy Agency (IAEA) has recently initiated a coordinated research program on safety significance of near-field earthquakes. The purpose of this program is to focus on the assessment of vulnerability of nuclear facility structures by using and adapting the best available engineering practices appropriate to evaluate the effects of near-field earthquakes. The objective of this paper is to evaluate of seismic responses of a shear building test specimen subjected to near-filed earthquakes. To achieve the objective, the seismic responses of the test specimen, evaluated by the Displacement Coefficient Method (DCM) and Nonlinear Dynamic Analysis (NDA), are compared with those by the experimental tests.

  • PDF

Development of Performance-Based Seismic Design of RC Column Retrofitted By FRP Jacket using Direct Displacement-Based Design (직접변위기반설계법에 의한 철근콘크리트 기둥의 FRP 피복보강 내진성능설계법의 개발)

  • Cho, Chang-Geun
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.11 no.2 s.54
    • /
    • pp.105-113
    • /
    • 2007
  • In the current research, an algorithm of performance-based seismic retrofit design of reinforced concrete columns using FRP jacket has been proposed. For exact prediction of the nonlinear flexural analysis or FRP composite RC members, multiaxial constitutive laws of concrete and composite materials have been presented. For seismic retrofit design, an algorithm of direct displacement-based design method (DDM) proposed by Chopra and Goel (2001) has been newly applied to determine the design thickness of FRP jacket in seismic retrofit of reinforced concrete columns. To compare with the displacement coefficient method (DCM), the DDM gives an accurate prediction of the target displacement in highly nonlinear region, since the DCM uses the elastic stiffness before reaching the yield load as the effective stiffness but the DDM uses the secant stiffness.

The comparison of accuracy on three-unit fixed dental prosthesis made with CAD/CAM milling machines (치과 캐드캠 밀링장비에 따른 3본브릿지의 정확도 비교)

  • Bae, So-Yeon;Park, Jin-Young;Kim, Ji-Hwan;Kim, Hae-Young;Kim, Myung-Bae;Kim, Woong-Chul
    • Journal of Technologic Dentistry
    • /
    • v.37 no.1
    • /
    • pp.9-15
    • /
    • 2015
  • Purpose: The purpose of this study was to compare the accuracy of the maxillary three-unit fixed dental prosthesis (FDPs) made using two CAD/CAM milling machines : DCM Group(Dentaim CAD/CAM milling machine), WCM Group(Wieland CAD/CAM milling machine). Methods: Each of 10 duplicate models was scanned by blue light scanner(Identica, Medit, Korea), and the three-unit FDPs (STL file) was designed using DelcamCAD. A total of 20 three-unit FDPs was fabricated, comprising 2 groups of 10 specimens each (shrinkage ratio is 1:1). The first three-unit FDPs STL file was used as a CAD reference model (CRM). Obtained STL files by scanning the inner surface of three-unit FDPs were convened into the point clouds-ASC II files. Discrepancies between the point clouds and CRM were measured by superimposition software. Statistical methods to analyze the data were used non-parametric method. The mean (SD) values were compared by a Mann-Whitney U-test. Type one error rate was set at 0.05. Results: WCM group had small discrepancies with $2.17{\mu}m$ of mean value compared to $4.44{\mu}m$ in DCM group. The accuracy values between the two groups showed a sratistically significant difference (Table 2, p<.05). Conclusion: The accuracy of the three-unit fixed dental prosthesis(FDPs) made of two CAD/CAM milling machines were statistically different. Accuracy with which the prosthesis made of WCM group was superior.

Power Factor Correction LED Driver with Small 120Hz Current Ripple (낮은 120Hz 출력 전류 리플을 갖는 역률개선 LED 구동 회로)

  • Sakong, Suk-Chin;Park, Hyun-Seo;Kang, Jeong-Il;Han, Sang-Kyoo
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.19 no.1
    • /
    • pp.91-97
    • /
    • 2014
  • Recently, the LED(Light Emitting Diode) is expected to replace conventional lamps including incandescent, halogen and fluorescent lamps for some general illumination application, due to some obvious features such as high luminous efficiency, safety, long life, environment-friendly characteristics and so on. To drive the LED, a single stage PFC(Power Factor Correction) flyback converter has been adopted to satisfy the isolation, PFC and low cost. The conventional flyback LED driver has the serious disadvantage of high 120Hz output current ripple caused by the PFC operation. To overcome this drawback, a new PFC flyback with low 120Hz output current ripple is proposed in this paper. It is composed of 2 power stages, the DCM(Discontinuous Conduction Mode) flyback converter for PFC and BCM(Boundary Conduction Mode) boost converter for tightly regulated LED current. Since the link capacitor is located in the secondary side, its voltage stress is small. Moreover, since the driver is composed of 2 power stages, small output filter and link capacitor can be used. Especially, since the flyback is operated at DCM, the PFC can be automatically obtained and thus, an additional PFC IC is not necessary. Therefore, only one control IC for BCM boost converter is required. To confirm the validity of the proposed converter, theoretical analysis and experimental results from a prototype of 24W LED driver are presented.

Polarity affects the antioxidant and antimicrobial activities of jellyfish (Acromitus hardenbergi) extracts

  • Khong, Nicholas M.H.;Foo, Su Chern;Yau, Sook Kun;Chan, Kim Wei;Yusoff, Fatimah Md.
    • Fisheries and Aquatic Sciences
    • /
    • v.25 no.4
    • /
    • pp.189-201
    • /
    • 2022
  • Jellyfish is an emerging aquaculture species, farmed for Oriental cuisines and nutraceutical ingredients. This study aimed to examine antioxidative and antimicrobial potentials of various fractions of the jellyfish, Acromitus hardenbergi. The bell and oral arms of the jellyfish were sequentially extracted with petroleum ether (PE), dichloromethane (DCM), chloroform (CHCl3), methanol (MeOH), and water (H2O) to extract its bioactive in an increasing polarity gradient. Test fractions were assayed for antiradical activities using electron spin resonance spectrometry, β-carotene-linoleate model and Folin-Ciocalteu assay; and antimicrobial activity against 2 Gram-negative bacteria, 4 Gram-positive bacteria and 2 fungal species using the disc diffusion assay. All fractions were also subjected to Fourier Transform Infrared (FTIR) analysis to identify types of functional groups present. It was found that the hydrophilic extracts (H2O fractions) possessed the most effective radical scavenging activity (p < 0.05) while the lipophilic extracts (PE fractions) the most active antimicrobial activity, especially against Gram-positive bacteria (p < 0.05). Total oxidation substrates content was found to be highest in the PE fractions of jellyfish bell and oral arms (p < 0.05). FTIR data showed that the H2O and MeOH fractions contains similar functional groups including -OH, -C=O, -N-H and -S=O groups, while the PE, DCM, and CHCl3 fractions, the -CH3, -COOH groups. This study showed that A. hardenbergi contains antioxidants and antimicrobials, thereby supporting the traditional claim of the jellyfish as an anti-aging and health-promoting functional food. Bioassay-guided fractionation approach serves as a critical milestone for the strategic screening, purification, and elucidation of therapeutically significant actives from jellyfish.

Power Supply for 60kW Industrial Magnetron (60kW 산업용 마그네트론 구동용 전원)

  • Jang, S.R.;Ahn, S.H.;Ryoo, H.J.;Kim, J.S.
    • Proceedings of the KIPE Conference
    • /
    • 2010.07a
    • /
    • pp.248-249
    • /
    • 2010
  • This paper deals with the design and experiment of 85kW(17kV, 5A) high voltage power supply for 60kW industrial magnetron. The power supply was designed based on the series resonant converter discontinuous conduction mode(DCM) which has the current source characteristic and high efficiency. In addition, inevitable leakage inductance of high voltage transformer can be used as resonant inductance. The basic analysis of full-bridge series resonant converter with transformer is given and the relationships between resonant tank parameters and input, output specification was derived. Simulation and experiment was done with variable switching frequency and their results verify the theoretical analysis.

  • PDF

Analysis and Design of a PFC AC-DC Converter with Electrical Isolation

  • Lin, Chia-Ching;Yang, Lung-Sheng;Zheng, Ren-Jun
    • Journal of Power Electronics
    • /
    • v.14 no.5
    • /
    • pp.874-881
    • /
    • 2014
  • This study presents a single-phase power factor correction AC-DC converter that operates in discontinuous conduction mode. This converter uses the pulse-width modulation technique to achieve almost unity power factor and low total harmonic distortion of input current for universal input voltage $90V_{rms}$ to $264V_{rms}$) applications. The converter has a simple structure and electrical isolation. The magnetizing-inductor energy of the transformer can be recycled to the output without an additional third winding. The steady-state analysis of voltage gain and boundary operating conditions are discussed in detail. Finally, experimental results are shown to verify the performance of the proposed converter.

An Optimal Design Methodology of an Interleaved Boost Converter for Fuel Cell Applications

  • Choe, Gyu-Yeong;Kim, Jong-Soo;Kang, Hyun-Soo;Lee, Byoung-Kuk
    • Journal of Electrical Engineering and Technology
    • /
    • v.5 no.2
    • /
    • pp.319-328
    • /
    • 2010
  • In this paper, an optimal selection methodology for the number of phases will be proposed for an interleaved boost converter (IBC). Also, the analysis of the input current ripple according to CCM and DCM is carried out. The proposed design methodology will be theoretically analyzed, and its validity verified by simulation as well as with experimental results. Moreover, a comparison of cost and efficiency based on a 600W laboratory prototype using the Ballard NEXA 1.2kW PEMFC system is demonstrated.

Active-clamp Class-E High Frequency Resonant Inverter with Single-st (단일 전력단으로 구성된 Active-clamp E급 고주파 공진 인버터)

  • Kang, Jin-Wook;Won, Jae-Sun;Kim, Dong-Hee;Ro, Chae-Gyun;Sim, Kwang-Yeal;Le, Bong-Sub
    • Proceedings of the KIEE Conference
    • /
    • 2002.07b
    • /
    • pp.1193-1195
    • /
    • 2002
  • This paper presents Active-clamp Class-E high frequency resonant inverter with single-stage. The proposed circuit is integrated Active-c class-E circuit to boost converter with the funct power factor correction. Boost converter is opera positive and negative half cycle respectively at frequency(60Hz), operating in Discontinuous Con Mode(DCM) of boost converter performs high p factor. By adding active-clamp circuit in Cl inverter, main switch of inverter part is operat only ZVS(Zero Voltage Switch), but also reduce switching voltage stress of main switch. Simulation result using Psim4.1 show that the p prove the validity of theoretical analysis. This proposed inverter will be able to be pract used as a power supply in various fields are ind heating applications, DC-DC converter etc.

  • PDF