• 제목/요약/키워드: DC-link

검색결과 1,020건 처리시간 0.028초

Single-Phase Multilevel PWM Inverter Based on H-bridge and its Harmonics Analysis

  • Choi, Woo-Seok;Nam, Hae-Kon;Park, Sung-Jun
    • Journal of Power Electronics
    • /
    • 제15권5호
    • /
    • pp.1227-1234
    • /
    • 2015
  • The efficient electric power demand management in electric power supply industry is currently being changed by distributed generation. Meanwhile, small-scale distributed generation systems using renewable energy are being constructed worldwide. Several small-scale renewable distributed generation systems, which can supply electricity to the grid at peak load of the grid as per policy such as demand response programs, could help in the stability of the electric power demand management. In this case, the power quality of the small-scale renewable distributed generation system is more significant. Low prices of power semiconductors and multilevel inverters with high power quality have been recently investigated. However, the conventional multilevel inverter topology is unsuitable for the small-scale renewable distributed generation system, because the number of devices of such topology increases with increasing output voltage level. In this paper, a single-phase multilevel inverter based on H-bridge, with DC_Link divided by bi-directional switches, is proposed. The proposed topology has almost half the number of devices of the conventional multilevel inverter topology when these inverters have the same output voltage level. Double Fourier series solution is mainly used when comparing PWM output harmonic components of various inverter topologies. Harmonic components of the proposed multilevel inverter, which have been analyzed by double Fourier series, are compared with those of the conventional multilevel inverter. An inverter prototype is then developed to verify the validity of the theoretical analysis.

Power Conditioning for a Small-Scale PV System with Charge-Balancing Integrated Micro-Inverter

  • Manoharan, Mohana Sundar;Ahmed, Ashraf;Seo, Jung-Won;Park, Joung-Hu
    • Journal of Power Electronics
    • /
    • 제15권5호
    • /
    • pp.1318-1328
    • /
    • 2015
  • The photovoltaic (PV) power conditioning system for small-scale applications has gained significant interest in the past few decades. However, the standalone mode of operation has been rarely approached. This paper presents a two-stage multi-level micro-inverter topology that considers the different operation modes. A multi-output flyback converter provides both the DC-Link voltage balancing for the multi-level inverter side and maximum power point tracking control in grid connection mode in the PV stage. A modified H-bridge multi-level inverter topology is included for the AC output stage. The multi-level inverter lowers the total harmonic distortion and overall ratings of the power semiconductor switches. The proposed micro-inverter topology can help to decrease the size and cost of the PV system. Transient analysis and controller design of this micro-inverter have been proposed for stand-alone and grid-connected modes. Finally, the system performance was verified using a 120 W hardware prototype.

ESS 구성을 위한 고효율 3-레벨 양방향 인버터 (High Efficiency 3-level bi-directional inverter for ESS)

  • 권오원;김준석;김광섭;차우준;권봉환;최정환;김수홍;이재근
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2016년도 전력전자학술대회 논문집
    • /
    • pp.271-272
    • /
    • 2016
  • 본 논문에서는 ESS 구성을 위한 고효율 3-레벨 양방향 인버터를 제안한다. 제안된 인버터는 저주파 레그와 고주파 레그로 구성되어, dc-link 전압과 계통간의 양방향 전력 변환을 수행한다. 제안된 인버터는 3-레벨의 전압을 제공하며 기존 풀브리지 타입의 2-레벨 인버터에 비해 고조파 성분이 적고 필터의 크기를 줄일 수 있다. 또한, 소자들에 걸리는 전압 스트레스가 낮고 동작 중에 스위칭 소자의 바디 다이오드를 사용하지 않기 때문에 도통 손실과 스위칭 손실을 최소화 할 수 있다. 따라서 제안하는 양방향 인버터는 기존 2-레벨 인버터 대비 높은 계통 전류 품질과 높은 효율을 제공한다. 최종적으로 시제품을 제작하여 제안하는 양방향 인버터의 타당성을 검증하였다.

  • PDF

온도에 따른 파라미터 변동을 고려한 정션 온도 추정 방법 (Junction Temperature Estimation Method Considering Parameter Change in Accordance with Temperature)

  • 양진규;변성훈;김정빈;김영민
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2016년도 전력전자학술대회 논문집
    • /
    • pp.89-90
    • /
    • 2016
  • 인버터에 사용되는 전력용 반도체 소자의 정션 온도는 모듈의 보호 및 수명 예측에 중요한 영향을 미친다. 온도를 추정하기 위해 제조사에서 제공되는 데이터 시트로부터 피라미터를 찾아 입력하게 되는데, 온도, 전류 및 $R_g$ 저항 등의 요인에 의해 이 파라미터가 변경된다. 본 논문은 온도 추정 과정에서 사용되는 파라미터에 온도에 따라 변동되는 성분을 선형화하여 추가하여 현재 온도에 맞는 파라미터를 계산해 낼 수 있는 방법에 관한 것으로 데이터 시트로부터 미리 계산된 계수 값을 이용하여 수식적으로 온도 의존성을 반영할 수 있다.이를 이용하여 부하 전류, 스위칭 주파수, DC Link 전압 등의 변동에 따라 정션 온도를 실시간으로 추정하였으며, iGBT 의 상단에 온도 센서를 부착하여 추정결과를 검증하였다. 본 방법을 통해 파라미터의 온도 의존성을 수식적으로 반영할 수 있으므로 파라미터를 저장하는 인버터의 데이터 저장 공간을 최소화 할 수 있다.

  • PDF

유연한 인간형 로봇 손의 설계 (Design of a Dexterous Anthropomorphic Robot Hand)

  • 지호준;이상헌;최병준;최혁렬
    • 대한기계학회논문집A
    • /
    • 제30권4호
    • /
    • pp.357-363
    • /
    • 2006
  • According to the study of grasping of the human hand, it is noted that the metacarpal link of the thumb plays the key role in power grasping. Also the face of fingertip can be discriminated into five parts depending on the grasping modalities such as pinch grasp, fingertip grasp and power grasp. In this paper, the design of the anthropomorphic robot hand which has a thumb and three fingers is proposed. A difference of SKKU hand II from the previous gripperlike robot hand is that the metacarpal bone is connected between the thumb and the palm. This thumb mechanism is specially designed to get the degree of freedom which can realize flexible motions relative to objects. Based on the analysis, the hand mechanism is developed. Since the driving circuits for the hand are embedded in the hand, only the communication lines supporting CAN protocol with DC power cable are necessary as the input. A new robot is manufactured and feasibility of the hand is validated through preliminary experiments.

Sensorless vector control for super-high speed PMSM drive

  • Bae Bon-Ho;Sul Seung-Ki;Kwon Jeong-Hyeck;Shin Jong-Sub
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 Proceedings ICPE 01 2001 International Conference on Power Electronics
    • /
    • pp.773-778
    • /
    • 2001
  • This paper describes the implementation of the vector control schemes for a variable-speed 131kW PMSM (Permanent Magnet Synchronous Motor) in super-high speed application. The vector control with synchronous reference frame current regulator has been implemented with the challenging requirements such as the extremely low stator inductance$(28^{\mu}H)$, the high dc link voltage(600V) and the high excitation frequency(1.2kHz). Because the conventional position sensor is not reliable in super-high speed, a vector control scheme without any position sensor has been proposed. The proposed sensorless algorithm is implemented by processing the output voltage of the PI current regulator, and hence the structure is simple and the estimated speed is robust to the measurement noise. The experimental system has been built and the proposed control has been implemented and evaluated. The test result, up to the speed of 60,000 r/min, shows the validity of the proposed control.

  • PDF

고분자전해질 연료전지(PEMFC)와 PEMFC/SCB의 동적 Matlab/Simulink 모델링 및 독립운전특성에 관한 연구 (A Study on the Comparison of the Stand-alone operation Characteristics and Matlab/Simulink Dynamic Model of PEMFC and PEMFC/SCB)

  • 홍원표;조재훈
    • 조명전기설비학회논문지
    • /
    • 제25권2호
    • /
    • pp.53-60
    • /
    • 2011
  • The available power generated from the FC power plant may not be sufficient to meet sustained load demand, peak demand or transient events. An supercapacitor bank(SCB) can supply a large burst of power, but it cannot store a significant amount of energy. The combined use of FC and SCB has the potential for the better energy efficiency, reducing the cost of FC technology and improved dynamic response. In this paper, A single PEMFC and PEMFC operated in parallel with a SC bank are presented, A new dynamic model of PEMFC system, the converter and controller has been developed for stand-alone applications. The simulation results are presented using Matlab/Simulink, and SimPowerSystems environments. It is confirmed that the results show a good performance and stable DC-link voltage for proposed dynamic and mathematical models developed for the combined FC/SCB.

BLDC 전동기 드라이브의 개방된 스위치 고장에 대한 고장 허용 시스템 (Fault Tolerant System for Open Switch Fault of BLDC Motor Drive)

  • 박병건;김태성;류지수;이병국;현동석
    • 전력전자학회논문지
    • /
    • 제11권2호
    • /
    • pp.164-171
    • /
    • 2006
  • 본 논문에서는 BLDC 전동기 구동용 인버터의 한 상에서 개방된 형태의 스위치 고장이 발생하여도 구동 시스템의 제어 성능을 유지하기 위한 고장 허용 시스템이 제안되었다. 고장의 확인 방법은 실제 전류와 기준 전류의 오차를 이용하는 방법과 인버터 하단에 전압센서를 추가하는 방법 등 두 가지 형태가 제안되었다. 시스템의 재구성 방법은 고장이 발생한 상을 양방향 스위치에 의해 직류-링크 중성점과 연결하여 4 스위치 구동의 형태로 구성하였다. 제안한 고장 허용 시스템은 짧은 고장 검출 시간과 시스템 토폴로지의 재구성에 의해 고장 발생 후 제어 성능을 빠르게 회복하여 연속적인 시스템 운영이 가능하다. 제안한 고장 허용 시스템의 우수한 성능은 시뮬레이션을 통하여 검증하였다.

An Optimized Control Method Based on Dual Three-Level Inverters for Open-end Winding Induction Motor Drives

  • Wu, Di;Su, Liang-Cheng;Wu, Xiao-Jie;Zhao, Guo-Dong
    • Journal of Power Electronics
    • /
    • 제14권2호
    • /
    • pp.315-323
    • /
    • 2014
  • An optimized space vector pulse width modulation (SVPWM) method with common mode voltage elimination and neutral point potential balancing is proposed for an open-end winding induction motor. The motor is fed from both of the ends with two neutral point clamped (NPC) three-level inverters. In order to eliminate the common mode voltage of the motor ends and balance the neutral point potential of the DC link, only zero common mode voltage vectors are used and a balancing control factor is gained from calculation in the strategy. In order to improve the harmonic characteristics of the output voltages and currents, the balancing control factor is regulated properly and the theoretical analysis is provided. Simulation and experimental results show that by adopting the proposed method, the common mode voltage can be completely eliminated, the neutral point potential can be accurately balanced and the harmonic performance for the output voltages and currents can be effectively improved.

에너지저장장치를 갖는 단상인버터에서 매끄러운 모드절환을 위한 알고리즘 개발 (A Seamless Mode Transfer Scheme for Single Phase Inverter with ESSs)

  • 변병주;서현욱;조영훈;최규하
    • 전력전자학회논문지
    • /
    • 제18권6호
    • /
    • pp.579-586
    • /
    • 2013
  • This paper proposes a mode transition algorithm between the grid-tied and the stand-alone operations for the single-phase inverter with the energy storage system. For the grid-tied operation, the dc-link voltage and the output current are required to be control. For the stand-alone mode, both the output voltage and the output current should be regulated. In order to mitigate a falling-off in control performance during transients in mode change, the load power estimation and the current selection schemes are proposed. The proposed method allows an optimized current reference is selected to reduce an output voltage drop and an excessive over-current in transient. To verify the effectiveness of the proposed method, both the simulation and the experiments for a 3kW single-phase inverter with the energy storage system have been conducted. From the results, it has been confirmed that the proposed method reduces a transient error as well as implementing smooth mode transition.