• 제목/요약/키워드: DC-link

검색결과 1,020건 처리시간 0.031초

조건부 적분기를 가지는 LQ 제어기를 이용한 3상 PWM 컨버터의 전류제어 (Current Control for Three Phase PWM Converter Using LQ Controller with Conditional Integrator)

  • 김홍성;전윤석;조영준;목형수;최규하;김한성
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1997년도 전력전자학술대회 논문집
    • /
    • pp.345-351
    • /
    • 1997
  • In this paper, controller for PWM converter considering unsymetrical input voltage is designed and current controller using LQ controller with conditional integrator is proposed. And the proposed current controller is compared with other current controller-predictive controller, decoupling PI controller. As simulation results, LQ controller with Conditional Integrator shows the improved performance for DC link voltage regulation through transient test of load variation. And when unsymeritrical input voltage is applied to converter with conventional current controller considering only symetrical input voltage, input current is distorted but it is showed that current controller considering unsymetrical input has robust control characteristics under phase voltage unbalance.

  • PDF

Novel Crest Factor Improvement of Electronic Ballast-Fed Fluorescent Lamp Current Using Pulse Frequency Modulation

  • Song Joong-Ho;Choy Ick;Choi Ju-Yeop
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 Proceedings ICPE 01 2001 International Conference on Power Electronics
    • /
    • pp.98-103
    • /
    • 2001
  • In case that electronic ballast employing a valley-fill passive power factor correction (PFC) circuit is used for feeding fluorescent lamps, a new method to reduce crest factor of the lamp current is studied in this paper. In order to reduce crest factor to lower value, a pulse frequency modulation technique based on the waveform of the dc-link voltage which is predetermined by the passive PFC circuit, is taken into the switching control action of the electronic ballast. An equation-based analysis between the crest factor of lamp current and the effect of varying the inverter switching frequency is comprehensively performed.

  • PDF

Fuse Protection of IGBT Modules against Explosions

  • Blaabjerg Frede;Iov Florin;Ries Karsten
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 Proceedings ICPE 01 2001 International Conference on Power Electronics
    • /
    • pp.703-707
    • /
    • 2001
  • The demand for protection of power electronic applications has during the last couple of years increased regarding the high-power IGBT modules. Even with an active protection, a high power IGBT still has a risk of exhibiting a violent rupture in the case of a fault if IGBT Fuses do not protect it. By introducing fuses into the circuit this will increase the circuit inductance and slight increase the over-voltage during the turn-off of the diode and the IGBT. It is therefore vital when using fuses that the added inductance is kept at a minimum. This paper discuss three issues regarding the IGBT Fuse protection. First, the problem of adding inductance of existing High-Speed and new Typower fuses in DC-link circuit is treated, second a short discussion of the protection of the IGBT module is done, and finally, the impact of the high frequency loading on the current carrying capability of the fuses is presented.

  • PDF

반도체 스위치를 이용한 양방향 고압 펄스 발생기 (Bi-polar High-voltage Pulse Generator Using Semiconductor switches)

  • 김종현;류명효;정인화;;김종수;임근희
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2003년도 춘계전력전자학술대회 논문집(1)
    • /
    • pp.291-293
    • /
    • 2003
  • A semiconductor switch-based fast hi-polar high voltage pulse generator is proposed in this paper The proposed pulse system is made of a thyristor based-rectifier, DC link capacitor, a push-pull resonant inverter, a high voltage transformer. secondary capacitor, a high voltage IGBT & diode stacks, and a variable capacitor. The proposed system makes hi-polar high voltage sinusoidal waveform using resonance between leakage inductance of the transformer and secondary capacitor and transfers energy to output load at maximum of the secondary capacitor voltage. Compared to previous hi-polar high voltage pulse power supply using nonlinear transmission line, the proposed pulse power system using only semiconductor switches has simple structure and gives high efficiency

  • PDF

전동차용 PWM 정류기를 위한 집전기(pantograph) 접점상태 검출방법 및 비접촉상태를 고려한 PWM 정류기 제어기법 (Pantograph Detachment Detector and Control Scheme for a PWM rectifier Considering Pantograph Detachement Condition)

  • 송홍석;남광희
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2003년도 춘계전력전자학술대회 논문집(1)
    • /
    • pp.275-278
    • /
    • 2003
  • The pantograph contact can be disrupted due to irregularities in the motion. The pantograph detachment prohibits the current flow and makes the system uncontrollable. During the pantograph detachment period, the control error are accumulated by the integral property of the controller. The output of the controller, therefore, can be induced to be an extremely large value. When the pantograph is reattached, the extremely large output of the controllers causes a very high overshoot (or under-shoot) of the line current and the DC-link voltage. This work proposes a new method for detecting the pantograph bouncing conditions and designs a controller considering such conditions based on the pantograph bouncing detector.

  • PDF

국내외 PV PCS 기술현황 (Recent PV PCS Technology)

  • 최주엽;유권종;정영석;소정훈;최익
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2005년도 춘계학술대회
    • /
    • pp.117-122
    • /
    • 2005
  • This paper proposes an inverter for the grid-connected photovoltaic system based on the transformer-less inverter. This system consists of a high frequency converter bridge, high frequency transformer, diode bridge rectifiers, a DC filter, a low frequency inverter bridge, and an AC filter. The high frequency converter bridge switching at 20kHz is used to generate bipolar PWM pulse, and the high frequency transformer raise its voltage twice, which is subsequently rectified by diode bridge rectifiers to result in a full-wave rectified sine wave. Finally, it is unfolded by a low frequency inverter bridge to result in a 60Hz sine wave power output. Even though the high frequency link system needs more power semiconductors, a reduced size, light weight, and saved parts cost make this system more comparative than the other systems due to elimination of 60Hz transformer.

  • PDF

Output Power Control of Wind Generation System by Machine Loss Minimization

  • Abo-Khalil Ahmed;Lee Dong-Choon
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2005년도 춘계학술대회
    • /
    • pp.51-54
    • /
    • 2005
  • Generator efficiency optimization is important for economic saving and environmental pollution reduction. In general, the machine loss can be reduced by the decreasing the flux level, resulting in the significant reduction of the core loss. This paper proposesan model-based controller is used to decrement the excitation current component on the basis of measured stator current and machine parameters and the q-axis current component controls the generator torque, by which the speed of the induction generator iscontrolled according to the variation of the wind speed in order to produce the maximum output power. The generator reference speed is adjusted according to the optimum tip-speed ratio. The generated power flows into the utility grid through the back-to-back PWM converter. The grid-side converter controls the dc link voltage and the line-side power factor by the q-axis and the d-axis current control, respectively. Experimental results are shown to verify the validity of the proposed scheme.

  • PDF

IPMSM을 이용한 PV 펌프 시스템의 FLC MPPT 제어 (FLC MPPT Control of PV Pump System using IPMSM)

  • 장미금;고재섭;강성준;김순영;문주희;이진국;정동화
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2011년도 제42회 하계학술대회
    • /
    • pp.1392-1393
    • /
    • 2011
  • This paper proposes fuzzy logic control maximum power point tracking(FLC MPPT) of photovoltaic(PV) pump system using IPMSM. Conventional MPPT controller was unstable by reason of the ripple-current of DC link in three phase inverter. Thus in this paper the control algorithm of IPMSM using $i_q$ current is composed to improve the insecurity of conventional MPPT controller. Proposed algorithm is operated by simulation with variation radiation condition. And analyze the response characteristic of IPMSM. The validity of this paper is proved by analyzed data.

  • PDF

Fuzzy Algorithm에 의한 1-링크 탄성 로보트 Arm 선단의 위치제어

  • 양길태;이영춘;이성철
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2001년도 추계학술대회 논문집
    • /
    • pp.149-153
    • /
    • 2001
  • This paper presents an end-point control of 1-link flexible arm tip-mass by using fuzzy position control algorithm. The arm is mounted on a translational mechanism driven by a ballscrew, whose rotation is controlled by a DC servomotor. Tip position is controlled so that it follows a desired position. Feedback signal is composed of both tip displacement error and change of error. This paper gives tip responses according to the variations of tip-mass and beam length, and the effects of reducing the residual vibrations occurring at the end-point. In the case of the residual vibrations of tip displacement, fuzzy control has better results than the PD-control.

구동 속도를 고려한 고속 영구자석형 동기발전기의 특성 해석 (Characteristic Analysis of a High Speed Permanent Magnet Synchronous Generator considering the Operating Speed)

  • 장석명;고경진;조한욱;정연호;오원규
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 추계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.116-118
    • /
    • 2006
  • Recently more attention is paid to the development of high-speed permanent magnet (PM) synchronous generators driven by gas-turbine, since they are conductive to high efficiency, high power density, small size, low weight, simple mechanical construction, easy maintenance and good reliability. In this paper, the performance analysis of a high-speed PM synchronous generator for military power application considering the min-max operating speed is presented. The output current and power versus DC-link voltage loci can obtained by solving the PM machine's steady-state equations for variable resistive load.

  • PDF