• Title/Summary/Keyword: DC-link

Search Result 1,020, Processing Time 0.028 seconds

The Power Analysis and Its Control of Two-phase Orthogonal Power Supply for the Continuous Casting

  • Ma, Fujun;Luo, An;Xiong, Qiaopo
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권3호
    • /
    • pp.971-982
    • /
    • 2015
  • In order to improve the quality of the billet continuous casting, a two-phase orthogonal power supply (TPOPS) for electromagnetic stirrer is researched, which is composed of three-phase PWM rectifier and three-leg inverter. According to the power analysis of system, the ripple of dc-link voltage is analyzed and its analytical expression is derived. In order to improve the performance of electromagnetic stirring, an integrated control method with feedforward control is proposed for PWM rectifier to suppress the fluctuations of dc-link voltage and provide a stable dc source for inverter. According to the simplified equivalent model, a composite current control method is proposed for inverter. This proposed method can combine the merits of feedforward control with feedback control to effectively improve the dynamic output performance of TPOPS. Finally, a 300kVA prototype of TPOPS is developed, and the results have verified the analysis and control method.

1kW급 태양광발전용 고주파링크 방식의 컨버터 (1kW Photovoltaic Converter with High Frequency Transformer)

  • 유병규;이기옥;유권종;최주엽
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.1087-1088
    • /
    • 2008
  • 계통연계형 태양광발전 시스템을 구성하고 있는 전력변환 장치인 PCS(power conditioning system)은 성능, 효율, 가격, 그리고 보호 및 협조 문제에 따라 여러 가지 형태가 있다. 본 논문에서는 고주파 변압기를 이용한 컨버터에 대하여 제안한다. 이 시스템은 FB(full bridge) 컨버터, 고주파 변압기, 다이오드 정류기, DC link 필터, PWM 인버터 그리고 저역통과필터로 이루어져 있다. 고주파 변압기를 이용한 컨버터의 스위칭 주파수는 10kHz로 Uniploar PWM 방식을 이용하였고, 변압기의 2차단에 다이오드 정류기와 커패시터를 통하여 DC로 정류한다. 고주파 변압기를 이용한 컨버터의 제어는 전압형 전류제어로 MPPT 알고리즘에 의한 입력전류제어를 담당하고, DC link 전압의 제어는 Unipolar PWM 인버터에서 제어를 담당한다. 논문에서는 고주파 변압기를 이용한 FB Conveter의 제어 방법에 대하여 시뮬레이션을 통하여 검증하고자 한다.

  • PDF

Capacitance Estimation of DC-Link Capacitor Considering Temperature Effect

  • 보성사;김경현;이동춘;이교범;김장목
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2010년도 하계학술대회 논문집
    • /
    • pp.156-157
    • /
    • 2010
  • This paper proposes a correction method of capacitance estimation considering the temperature effect for the DC-link capacitor banks in three-phase AC/DC PWM converters. In this work, a sensing circuit using a temperature sensor is designed for measuring the operating temperature. Capacitance value is corrected considering the measured temperature. This method has been implemented in experiment.

  • PDF

3상 2레벨 계통연계형 태양광 인버터의 강인제어 (Robust Control of a Grid Connected Three-Phase Two-Level Photovoltaic Inverter)

  • 안경필;이영일
    • 전력전자학회논문지
    • /
    • 제19권6호
    • /
    • pp.538-548
    • /
    • 2014
  • This study provides a robust control of a grid-connected three-phase two-level photo voltaic inverter. The introduced control method uses the cascade control strategy to regulate AC-side current and DC-link voltage. A robust controller with integration action is used for the inner-loop AC-side current control, which maximizes the convergence rate using a linear matrix inequality-based optimization design method and eliminates the offset error. The robust controller design method considers the parameter uncertainty set to accommodate parameter mismatch and un-modeled components in the inverter model. An outer-loop proportional-integral controller is used to regulate DC-link voltage with linearization of DC/AC relation. The proposed control strategy is applied to a grid-connected 100 kW photo voltaic inverter.

보조공진 DC 링크 스너버를 이용한 3상 전압형 소프트 스위칭 인버터 (Three Phase Voltage-ed Soft Switching Inverter using Auxiliary Resonant DC Link)

  • 김주용;서기영;이현우;문상필;류재엽
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.143-146
    • /
    • 2002
  • This paper proposes a new auxiliary resonant DC link(ARDCL)snubber circuit and deals with its power loss on the basis of actually-measured conduction loss characteristic of switching device module. Voltage-ed soft switching three-phase inverter using proposed ARDCL snubber circuit is presented along with its performance evaluations. And, the power loss analysis of three-phase hard and soft switching inverter are carried out from the point of simulation and experimental results.

  • PDF

A PI-based Control Scheme for Primary Cascaded H-Bridge Rectifier in Transformerless Traction Converters

  • Tao, Xing-Hua;Li, Yong-Dong;Sun, Min
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • 제1권3호
    • /
    • pp.360-365
    • /
    • 2012
  • Cascaded H-Bridge rectifier (CHBR) is a more attractive solution in traction application for its transformerless structure. Because of the currents of different cells are exactly the same one, it is a challenge job to regulate the voltages of cells with only one current controller. In this paper, a PI-based control scheme is presented to deal with the voltages balance issue in CHBR. To satisfy the demand of rectifier such as unity power factor and regulated output DC voltages, the proposed control scheme consists of two parts. One is for shaping the grid current waveform and regulating the sum of DC-link voltages of all the cells; the other one is for balancing DC-link voltages. The latter is more concerned in this paper and is discussed in detail especially. Simulations and experiments are carried on. The results verified the feasibility and effectiveness of the proposed scheme.

준 공진 DC 링크를 사용한 공간 벡터 PWM 인버터의 구현 (Realization of the Space Vector PWM Inverter Using a Quasi - Resonant DC Link)

  • 한완옥;조성정;이정규;임승하;이성백
    • 전자공학회논문지B
    • /
    • 제31B권12호
    • /
    • pp.137-144
    • /
    • 1994
  • In this paepr, we present a soft switching PWM inverter as reducing switching loss and stress at high power application. The PWM inverter is designed by space voltage about 2$\sqrt{3}$ times (15%) than conventional SPWM method. To reduce switching loss and stress. The DC link requires a capacitor, an inductor and two additional switches. Therefore proposed inverter performs trun PWM operation under the soft switching condition. As a result of soft switching we can reduce switching loss and ensure stability of switching devices. For approach to real time, control system is realized by 8 bit single-chip microprocessor. Therefore, we can construct system is with simplified volumn and structure by eliminating carrier wave and referrence wave generator of conventional SPWM method.

  • PDF

연료전지 발전 시스템용 고주파 링크 DC-AC 컨버터 (A High Frequency Link Direct DC-AC Converter for Fuel Cell Power Source)

  • 송유진;박석인;정학근;한수빈;정봉만
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2005년도 학술대회 논문집
    • /
    • pp.245-249
    • /
    • 2005
  • This paper describes a boost converter cascaded high frequency link direct dc-ac converter suitable for fuel cell power sources. A new multi-loop control for a boost converter to reduce the low frequency input current harmonics drawn from fuel cell is proposed. A new PWM technique for the cycloconverter at the secondary to reject the low order harmonics in the output voltages is presented in detail.

  • PDF

A Commutation Torque Ripple Reduction for Brushless DC Motor Drives

  • Won, Chang-hee;Song, Joong-Ho;Ick Choy
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • 제2B권4호
    • /
    • pp.174-182
    • /
    • 2002
  • This paper presents a comprehensive study on reducing commutation torque ripples generated in brushless DC motor drives with only a single do-link current sensor provided. In such drives, commutation torque ripple suppression techniques that are practically effective in low speed as well as high speed regions are scarcely found. The commutation compensation technique proposed here is based on a strategy that the current slopes of the incoming and the outgoing phases during the commutation interval can be equalized by a proper duty-ratio control. Being directly linked with deadbeat current control scheme, the proposed control method accomplishes suppression of the spikes and dips superimposed on the current and torque responses during the commutation intervals of the inverter. Effectiveness of the proposed control method is verified through simulations and experiments.

상 저항을 고려한 BLDC Motor의 상 전환 토크리플 저감에 대한 연구 (Commutation torque ripple reduction in brushless dc motor considering phase resistance)

  • 오대영;최익;송중호
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2007년도 하계학술대회 논문집
    • /
    • pp.220-222
    • /
    • 2007
  • 본 논문에서는 하나의 DC-Link 전류센서를 사용하여 BLDC 모터의 상 저항을 고려한 상 전환 토크리플 저감 방법을 제안하고자 한다. 지금까지 하나의 DC-Link 전류센서를 사용하여 BLDC 모터의 상 전환 토크리플 저감에 대한 연구는 많이 진행 되어 왔다. 기존의 방법들은 상 저항 값을 무시하여 상 인덕턴스 성분만을 가지고 제어한 방법이 주류를 이루어 왔다. 하지만 상 저항 값이 크면, 저속 영역과 고속 영역 구간에 변화를 가져와 기존의 방법을 사용할 시 토크리플이 발생한다. 또한 상 전환 시 전류 기울기와 상 전환 시간에 대해 영향을 미치게 되어 기존의 방법을 사용할 경우 토크리플이 발생하게 된다. 본 논문에서는 시뮬레이션을 통하여 상 저항을 고려한 BLDC 모터의 상 전환 토크리플 저감 방법에 대해 효용성을 입증하고자 한다.

  • PDF