• Title/Summary/Keyword: DC transmission

Search Result 477, Processing Time 0.026 seconds

Electrical characteristics of soot particles in a LPG diffusion flame and particle size change by electric fields (LPG 확산화염내 매연입자의 전기적 특성 및 전기장에 의한 입자 크기 변화)

  • Park, Jong-In;Ji, Jun-Ho;Hwang, Jeong-Ho
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.21 no.10
    • /
    • pp.1326-1338
    • /
    • 1997
  • Electrical characteristics of soot particles in a LPG diffusion flame were studied for the control of soot particle coagulation. When a DC voltage was applied between two electrodes installed parallel to gas flow, ionic wind effect caused soot deposition on the cathode, implying that most of the soot particles were positively charged. Soot deposit on the cathode linearly increased and was saturated with respect to the strength of the applied voltage. The possibility of applying an AC voltage to enhance the particle coagulation was then investigated and the efficiency of the size control was checked with transmission electron microscope photographs. For the amplitude of 2 kV AC field, primary (spherical) soot particle size decreased from 30 ~ 40 nm to around 20 nm when the frequency of the applied AC voltage was 60 Hz and higher. Collisions between the soot particles in such a selected AC condition could lead to the formation of much bigger agglomerates of roughly 1-5 .mu.m in size.

The study on formation of ITO by DC reacrive magnetron sputtering (반응성 직류마그네트론 스퍼터링에 의한 ITO박막 형성에 관한 연구)

  • 하홍주;조정수;박정후
    • Electrical & Electronic Materials
    • /
    • v.8 no.6
    • /
    • pp.699-707
    • /
    • 1995
  • The material that is both conductive in electricity and transparent to the visible ray is called transparent conducting thin film. It has many fields of application such as Solar Cell, Liquid Crystal display, Vidicon on T.V, transparent electrical heater, selective optical filter, and a optical electric device , etc. In the recent papers on several TCO( transparent conducting oxide ) material, the study is mainly focusing on ITO(indium tin oxide) because ITO shows good results on both optical and electrical properties. Nowaday, in the development of LCD(Liquid Crystal display), the low temperature process to reduce the production cost and to deposit ITO on polymer substrate (or low melting substrate) has been demanded. In this study, we prepared indium tin oxide(ITO) by a cylindrical DC magnetron sputtering with Indium-tin (9:1) alloy target instead of indium-tin oxide target. The resistivity of the film deposited in oxygen partial pressure of 5% and substrate temperature of 140.deg. C. is 1.6*10$\^$-4/.ohm..cm with 85% optical transmission in viaible ray.

  • PDF

Active Voltage-balancing Control Methods for the Floating Capacitors and DC-link Capacitors of Five-level Active Neutral-Point-Clamped Converter

  • Li, Junjie;Jiang, Jianguo
    • Journal of Power Electronics
    • /
    • v.17 no.3
    • /
    • pp.653-663
    • /
    • 2017
  • Multilevel active neutral-point-clamped (ANPC) converter combines the advantages of three-level ANPC converter and multilevel flying capacitor (FC) converter. However, multilevel ANPC converter often suffers from capacitor voltage balancing problems. In order to solve the capacitor voltage balancing problems for five-level ANPC converter, phase-shifted pulse width modulation (PS-PWM) is used, which generally provides natural voltage balancing ability. However, the natural voltage balancing ability depends on the load conditions and converter parameters. In order to eliminate voltage deviations under steady-state and dynamic conditions, the active voltage-balancing control (AVBC) methods of floating capacitors and dc-link capacitors based on PS-PWM are proposed. First, the neutral-point current is regulated to balance the neutral-point voltage by injecting zero-sequence voltage. After that, the duty cycles of the redundant switch combinations are adjusted to balance the floating-capacitor voltages by introducing moderating variables for each of the phases. Finally, the effectiveness of the proposed AVBC methods is verified by experimental results.

Data Transmission through Power Line of Smart Transmitter

  • Kim, Jong-Hyun;Kang, Hyun-Kook;Seong, Poong-Hyun
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1996.05a
    • /
    • pp.471-476
    • /
    • 1996
  • In this study, the method to use the phase shift keying (PSK) communication technique in smart transmitter is presented. In nuclear applications. smart transmitters for various parameters are expected to improve the accuracy of measurement and to reduce the load of calibration work. The capability of communication in field level is the most important merit of the smart transmitter. The most popular method is using of digital and analog techniques simultaneously - transmitting measurements from the field at 4∼20mA while modulating the current to carry digital information in both directions over the same twisted pairs. Conventional smart transmitters use the frequency shift keying (FSK) method for digital communication. Generally, however, the FSK method has the speed limit at 1200 bps. Amount of information to transmit becomes increasing as the processing technique is improved. The PSK method is noticeable alternative for high speed digital communication, but it has non-zero DC component. In order to use the PSK method in the field transmission with smart transmitter, the method to remove the DC component is studied in this work.

  • PDF

The generation and detection of binary signals by narrow terahertz dipole antenna (좁은 간격의 테라헤르츠 다이폴 안테나를 이용한 이진신호의 발생과 검출)

  • 전태인;김근주
    • Korean Journal of Optics and Photonics
    • /
    • v.13 no.5
    • /
    • pp.430-434
    • /
    • 2002
  • We present the magnitude of terahertz electromagnetic pulses when femtosecond laser pulses are moving along to a dipole antenna. The dipole antenna chip has maximum 4.7 nA THz current, generated at 11 DC volt. This current is 3.4 times bigger than the current of a $300{\mu}{\textrm}{m}$ separated transmission line structure chip that has 70 DC volt. We also apply an AC square wave voltage to the dipole antenna from 0.1 volt to 10 volt for binary signals using the terahertz electromagnetic pulses.

Approach for Microwave Frequency Measurement Based on a Single Photonic Chip Combined with a Phase Modulator and Microring Resonator

  • Zhang, Jiahong;Zhu, Chuyi;Yang, Xiumei;Li, Yingna;Zhao, Zhengang;Li, Chuan
    • Current Optics and Photonics
    • /
    • v.2 no.6
    • /
    • pp.576-581
    • /
    • 2018
  • A new approach for identification of a microwave frequency using an integrated optical waveguide chip, combined with a phase modulator (PM) and two microring resonators (MRRs), is proposed, theoretically deduced, and verified. By wavelength tuning to set the PM under the condition of a double side band (DSB), the measurement range can be started from the dc component, and the measurement range and response slope can be adjusted by designing the radius and transmission coefficient of the MRR. Simulations reveal that the amplitude comparison function (ACF) has a monotonic relationship from dc to 32.5 GHz, with a response slope of 5.15 dB under conditions of DSB modulation, when the radius values, transmission coefficients, and the loss factors are designed respectively as $R_1=400{\mu}m$, $R_2=600{\mu}m$, $t_1=t_2=0.63$, and ${\gamma}_1={\gamma}_2=0.66$. Theoretical calculations and simulation results both indicate that this new approach has the potential to be used for measuring microwave frequencies, with the advantages of compact structure and superior reconfigurability.

Application Analysis of a Resistive type SFCL for Transmission Systems (EMTCD를 이용한 154kV 송전계통에서의 초전도 한류기 적용 해석)

  • Heo Tae Jeon;Bae Hyeong Thaek;Park Min Won;Yu In Keun
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.409-411
    • /
    • 2004
  • The need for Fault Current Limiters (FCL) is associated with the continuous growth and interconnection of modem power systems and increase in dispersed generation facilities, which result in progressive increase in the short circuit capacity far beyond their original design capacity. Fault Current Limiters (FCL) clips the fault currents and reduces the electromechanical stresses on the network and the need to handle excessive fault currents. In addition, the reduction of the fault duration Provided by the limiter should increase the power transmission capability and improve the dynamic stability. This paper proposes the model of resistive type superconducting fault current limiter using EMTDC(Electromagnetic transients for DC analysis program). In order to verify the effectiveness of the SFCL, in this paper, the analysis of fault current in a transmission system through the EMTDC based simulation by using the modeled component of a resistive type SFCL is peformed and the detailed results are given.

  • PDF

A Breaching of Electromagnetic Shielding by Narrow Aperture in Metal Film

  • Park, Doo Jae;Chu, Hong;Kyoung, Jisoo;Choi, Soo Bong
    • Journal of the Optical Society of Korea
    • /
    • v.20 no.5
    • /
    • pp.563-566
    • /
    • 2016
  • We report a theoretical research for the condition of electromagnetic shield breaching when a narrow aperture is punctured in thin metal film. To calculate electromagnetic field transmission through a narrow slit, a Rayleigh wave expansion has been applied for free standing, thin metal film. We found that the DC electric field allows perfect transmission when the length of the slit is infinite, regardless of the other geometrical factors such as slitwidth and thickness. Slitwidth dependent transmission spectra as a function of frequency shows a cutoff frequency that decreases almost linearly to the slitwidth, giving that almost successful shielding is only possible when the slitwidth is smaller than 1 micron.

Economic Assessments of LFAC and HVDC Transmissions for Large Offshore Wind Farms

  • Park, Taesik;Kwak, Nohong;Moon, Chaeju;Cha, Seungtae;Kwon, Seongchul
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.1 no.1
    • /
    • pp.73-77
    • /
    • 2015
  • Offshore wind farms extend a distance from an onshore grid to increase their generating power, but long distance and high power transmissions raise a lot of cost challenges. LFAC (Low Frequency AC) transmission is a new promising technology in high power and low cost power transmission fields against HVDC (High Voltage DC) and HVAC (High Voltage AC) transmissions. This paper presents an economic comparison of LFAC and HVDC transmissions for large offshore wind farms. The economic assessments of two different transmission technologies are analyzed and compared in terms of wind farm capacities (600 MW and 900 MW) and distances (from 25 km to 100 km) from the onshore grid. Based on this comparison, the economic feasibility of LFAC is verified as a most economical solution for remote offshore wind farms.

Electrical characteristics simulation of thyristor devices for HVDC transmission (HVDC용 사이리스터 소자의 전기적 특성 simulation 연구)

  • Kim, Sang-Cheol;Seo, Kil-Soo;Kim, Eun-Dong
    • Proceedings of the KIEE Conference
    • /
    • 2003.07c
    • /
    • pp.1559-1561
    • /
    • 2003
  • In northeast Asia, there will be several important HVDC transmission lines to be established in Korea and China for perspective electric network market. 5500V 4-inches High voltage thyristor can be used in the DC transmission and distribution of electric power system. In this application, many thyristors are connected in series for each thyristor valves. Therefore, the required low reverse-recovery charge QRR and low on-state voltage drop $V_{TM}$ for such thyristor is necessary to this application. In our work, the on-state and off-state voltage performance was simulated by commercial simulation software.

  • PDF