• 제목/요약/키워드: DC supply

검색결과 1,055건 처리시간 0.029초

디지털 제어 방식의 능동 클램프형 DC-DC 컨버터에 관한 연구 (A Study On Active Clamp DC-DC Converter Using Digital Control)

  • 원기식;안태영
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2004년도 전력전자학술대회 논문집(2)
    • /
    • pp.807-810
    • /
    • 2004
  • This is a experimental result which is reported with using 16-Bit microprocessor H8 series of Renesas company, organizing digital control which is practicable PWM embodiment, and applying switched-mode power supply. The basic topology consists of the active clamp forward DC-DC converter which is widely used for the highly efficient power supply these days. In an experiment, it incites the result to lay emphasis on the highly efficient operation of converter, and performance of digital control which is practicable PWM embodiment. And it is debated on performance of processor and condition for improving performance of part.

  • PDF

PC 파워 서플라이용 비대칭 하프브리지 DC/DC 컨버터의 초기 구동시 돌입전류 제거 기법 (Start-up In-rush Current Reduction Technique of Asymmetrical Half-Bridge DC/DC Converter for PC Power Supply)

  • 김재국;이성세;오원식;김정은;문건우;길창현;조자룡
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2006년도 전력전자학술대회 논문집
    • /
    • pp.251-253
    • /
    • 2006
  • This paper presents a start-up in-rush current reduction technique of asymmetry half-bridge DC/DC converter for PC power supply. The proposed converter is composed center-tapped half-bridge converter with blocking capacitor. The proposed converter can reduce the severe in-rush current when the proposed converter is power up. The validity of this study is confirmed from the experimental results.

  • PDF

30kV 절연성능을 갖는 고절연 DC-DC 컨버터에 관한 연구 (A study and implementation of a 30kV highly isolated DC-DC converter)

  • 김정우;부한영;조영훈;김호성;김주용
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2017년도 전력전자학술대회
    • /
    • pp.355-356
    • /
    • 2017
  • In this paper, a highly isolated DC-DC converter is designed as a power supply, and an insulator-molded transformer is used to achieve high insulation performance. Finally, the insulation performance of the power supply was verified by experimental results.

  • PDF

NBI용 필라멘트 전원공급 장치 설계 (Filament Power Supply Design for Neutral Beam Injection)

  • 전범수;이희준;이승교;류동균;이택기;원충연
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2010년도 추계학술대회
    • /
    • pp.30-31
    • /
    • 2010
  • Filament power supply (FPS) for neutral beam injection (NBI) consists of an insulation type is a device that heats the interior of Tokamak. The input/output specifications of FPS are 3-phase AC 200[Vpeak] and DC16V/300A respectively. A conventional FPS is composed of a 3-phase diode rectifier with DC-link, a H-bridge DC/DC converter, a high frequency transformer, a secondary rectifier and a LC-filter. In this paper, to improve the efficiency of PSFB DC/DC converter it is substituted IGBT devices instead of diode rectifier in secondary side. The proposed method is verified by computer simulation and experiment result.

  • PDF

A Study on DC-DC Converter Development for LRT Wireless Power Supply

  • Han, Young-Jae;Lee, Su-Gil;Lee, Young-Ho
    • 한국컴퓨터정보학회논문지
    • /
    • 제23권12호
    • /
    • pp.179-184
    • /
    • 2018
  • In this paper, we have proposed the development of DC-DC converter for LRT power supply. First of all, we have studied converter technology, main functions and characteristics were determined. In also, the converter design was carried out to meet the system design conditions. Based on this design, converter simulation is performed to enable stable charging and discharging of the vehicle system. We have performed the Light-load test according to charge mode, discharge mode. As a result, the manufactured converter performance was verified through the load test, and it's stability was confirmed.

PI Controlled Active Front End Super-Lift Converter with Ripple Free DC Link for Three Phase Induction Motor Drives

  • Elangovan, P.;Mohanty, Nalin Kant
    • Journal of Power Electronics
    • /
    • 제16권1호
    • /
    • pp.190-204
    • /
    • 2016
  • An active front end (AFE) is required for a three-phase induction motor (IM) fed by a voltage source inverter (VSI), because of the increasing need to derive quality current from the utility end without sacrificing the power factor (PF). This study investigates a proportional-plus-integral (PI) controller based AFE topology that uses a super-lift converter (SLC). The significance of the proposed SLC, which converts rectified AC supply to geometrically proceed ripple-free DC supply, is explained. Variations in several power quality parameters in the intended IM drive for 0% and 100% loading conditions are demonstrated. A simulation is conducted by using MATLAB/Simulink software, and a prototype is built with a field programmable gate array (FPGA) Spartan-6 processor. Simulation results are correlated with the experimental results obtained from a 0.5 HP IM drive prototype with speed feedback and a voltage/frequency (V/f) control strategy. The proposed AFE topology using SLC is suitable for three-phase IM drives, considering the supply end PF, the DC-link voltage and current, the total harmonic distortion (THD) in supply current, and the speed response of IM.

전기철도의 DC급전시스템 시뮬레이터 (Simulator for DC Power Supply System in Electric Railway)

  • 정상기;홍재승
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2000년도 추계학술대회 논문집
    • /
    • pp.720-726
    • /
    • 2000
  • The advance of traction motor control technology and the complexity of the traction power supply system makes the simulation essential in determining the dimension of the traction power supply system. The conventional method, use of the simplified and/or empirical equations, becomes inadequate in optimization of the design. The simulator presented in this paper is a numerical time based simulator running on a PC. The input to the simulator includes the track data, the train characteristic, network data and operating data. Basically the simulator conducts train running simulation and loadflow study repeatedly. The principle algorithms and its output is discussed in the paper.

  • PDF

LCCC 공진회로와 ZVS 기능을 동시에 갖는 전류형 Push Pull DC-DC 컨버터의 특성해석 (A Characteristic Analysis of Current-Fed Push Pull type DC-DC converter using LCCC Resonant circuit and ZVS function)

  • 안항목;황계호;이달해;남승식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 B
    • /
    • pp.1324-1326
    • /
    • 2000
  • This paper proposes a Current-Fed Push Pull type DC-DC converter using LCCC Resonant circuit and Zero Voltage Switching function to reduce turn on and off loss at the switching instants. This paper have the advantage which is able to operating safely in load short, because of DC reactor is connected with resonance reactor in order to supply a fixed current with low ripple from DC Power supply. The capacitor ($C_1$, $C_2$) connected in switch are common using as resonance capacitor and ZVS capacitor. The analysis of the proposed Current-Fed Push Pull type DC-DC converter is generally described by using normalized parameter, and we have evaluated characteristic values which is needed to design a circuit. We confirm a rightfulness theoretical analysis by comparing a theoretical values and experimental values obtained from experiment using MOSFET as switching devices.

  • PDF

PWM컨버터를 적용한 경전철 전력공급시스템에 관한 연구 (A Study on DC Traction Power Supply System Using PWM Converter)

  • 김주락;박창릉;박기준;김주욱
    • 한국전기전자재료학회논문지
    • /
    • 제29권4호
    • /
    • pp.250-254
    • /
    • 2016
  • Currently, power conversion system which converts AC to DC Power is applied in domestic urban railway. The diode rectifier is used in most of them. However the diode rectifier can not control the output voltage and can not regenerate power as well. On the other hand, PWM (pulse width modulation) converter using IGBT (isolated gate bipolar transistor) can control output voltage, allowing it to reduce the output voltage drop. Moreover the Bi-directional conduction regenerates power which does not require additional device for power regeneration control. This paper compared the simulation results for the DC power supply system on both the diode rectifier and the PWM converter. Under the same load condition, simulation circuit for each power supply system was constructed with the PSIM (performance simulation and modeling tool) software. The load condition was set according to the resistance value of the currently operating impedance of light rail line, and the line impedance was set according to the distance of each substations. The train was set using a passive resistor. PI (proportional integral) controller was applied to regulate the output voltage. PSIM simulation was conducted to verify that the PWM Converter was more efficient than the diode rectifier in DC Traction power supply system.

DC 급전시스템의 지락보호계전시스템 개발 (Development of Ground Fault Protective Relaying Schemes for DC Traction Power Supply System)

  • 정상기;정락교;조홍식;이안호;권삼영
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제54권9호
    • /
    • pp.427-433
    • /
    • 2005
  • In DC tracking power supply system, ground faults are currently detected by the potential relay, 64P. Though 64P relay detects ground fault, it cannot Identify the faulted region which causes long traffic delays and safety problem to passengers. Two new ground fault protective relay schemes that can identify the faulted region are presented in this paper. One is bus differential protective relay and the other is ground overcurrent protective relay. Both type of relays is similar in principle to the ordinary bus differential protective relay and the ground overcurrent relay used in other power system. In DC traction power supply system, since it is ungrounded, ground fault current is not big enough to operate those relays. To solve the problem, a current control device, called device 'X', is newly introduced in both system, which enables large amount of ground fault current flow upon the positive line to ground fault. Algorithms for these relays are developed and their validity are verified by EMTP simulation.