• Title/Summary/Keyword: DC potential

Search Result 368, Processing Time 0.043 seconds

Anti-inflammatory Activities of Chopi (Zanthoxylum piperitum A.P. DC) Essential Oil: Suppression of the Inducible Nitric Oxide Synthase and Cellular Adhesion

  • Lee, Je-Hyuk;Chang, Kyung-Mi;Kim, Gun-Hee
    • Food Science and Biotechnology
    • /
    • v.18 no.6
    • /
    • pp.1371-1378
    • /
    • 2009
  • The aim of this study is to elucidate the anti-inflammatory activities of chopi (Zanthoxylum piperitum A.P. DC.) essential oil. Essential oil (EO) of chopi was extracted by steam distillation method, and its major constituents were limonene and geranyl acetate. Chopi-EO decreased approximately 38% of nitrite production, as compared to the lipopolysaccharde (LPS)-induced nitrite production. However, chopi-EO and its components did not quench nitric oxide (NO) chemically in cellfree system, and markedly inhibited approximately 40.4% of inducible nitric oxide synthase (iNOS) mRNA transcription. In addition, the inhibition of E-selectin gene transcription by chopi-EO caused the suppression of cellular adhesion. These results suggest that chopi-EO may exert potential anti-immunological inflammatory activity.

Simulation of a Dually Excited Capacitively Coupled RF Plasma

  • Kim, Heon-Chang;Sul, Yong-Tae;Park, Sung-Jin
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2005.07a
    • /
    • pp.513-514
    • /
    • 2005
  • In plasma processing reactors, it is common practice to control plasma density and ion bombardment energy by manipulating excitation voltage and frequency. In this paper, a dually excited capacitively coupled rf plasma reactor is self-consistently simulated with a three moment model. Effects of phase differences between primary and secondary voltage waves, simultaneously modulated at various combination of commensurate frequencies, on plasma properties are investigated. The simulation results show that plasma potential and density as well as primary self-dc bias are nearly unaffected by the phase lag between the primary and the secondary voltage waves. The results also show that, with the secondary frequency substantially lower than the primary frequency, secondary self-dc bias remains constant regardless of the phase lag. As the secondary frequency approaches to the primary frequency, however, the secondary self-dc bias becomes greatly altered by the phase lag, and so does the ion bombardment energy at the secondary electrode. These results demonstrate that ion bombardment energy can be more carefully controlled through plasma simulation.

  • PDF

A Control Method of Electric Railway Vehicle Recycle Energy Storage System Using Supercapacitor (슈퍼커패시터를 이용한 전동차량 화생 에너지 저장 시스템의 제어기법)

  • Noh, Se-Jin;Lee, Jin-Mok;Son, Kyoung-Min;Choi, Jae-Ho
    • Proceedings of the KIPE Conference
    • /
    • 2008.06a
    • /
    • pp.97-99
    • /
    • 2008
  • It is possible to suppress voltage drops, power loading fluctuations and regeneration power lapses for DC railway systems by applying an energy storage system. Recently the electric double layer capacitor (EDLC) of the rapid charge/discharge type has been developed and used in wide ranges. The on board energy storage system with supercapacitor for railway vehicles presented in this paper seems to be a reliable technical solution with an enormous energy saving potential. In this paper, an efficient charge and discharge control method of a bidirectional DC-DC converter using the supercapacitor is proposed.

  • PDF

Effects of Phase Difference between Voltage loaves Applied to Primary and Secondary Electrodes in Dual Radio Frequency Plasma Chamber

  • Kim, Heon-Chang
    • Journal of the Semiconductor & Display Technology
    • /
    • v.4 no.2 s.11
    • /
    • pp.11-14
    • /
    • 2005
  • In plasma processing reactors, it is common practice to control plasma density and ion bombardment energy by manipulating excitation voltage and frequency. In this paper, a dually excited capacitively coupled rf plasma reactor is self-consistently simulated with a three moment model. Effects of phase differences between primary and secondary voltage waves, simultaneously modulated at various combinations of commensurate frequencies, on plasma properties are investigated. The simulation results show that plasma potential and density as well as primary self-dc bias are nearly unaffected by the phase lag between the primary and the secondary voltage waves. The results also show that, with the secondary frequency substantially lower than the primary frequency, secondary self·do bias remains constant regardless of the phase lag. As the secondary frequency approaches to the primary frequency, however, the secondary self-dc bias becomes greatly altered by the phase lag, and so does the ion bombardment energy at the secondary electrode. These results demonstrate that ion bombardment energy can be more carefully controlled through plasma simulation.

  • PDF

A Study on High Impedance Grounding Protection for DC Power Supply System (DC 급전계통 고저항 지락보호에 대한 연구)

  • Lee, Kuk-Myoung;Kim, Byung-Hyun;So, Sun-Young;Kim, Hak-Lyun
    • Proceedings of the KSR Conference
    • /
    • 2006.11b
    • /
    • pp.878-884
    • /
    • 2006
  • Grounding fault and short of the DC power supply systems are detected and protected by high-speed circuit breaker, linked breaking device, ground relay and fault selective device, all of which are installed and operated in substaions. however, there have been many cases in which the protective devices did not detect grounding of of the over head catenary systems on concrete support for an extended period of time. Such cases often cause severe damages to the supports with high grounding resistances. If grounding accidents occur repetitively, the earth current and the rise of earth potential can damage not only passenger and staff but also electric facilities and equipment, necessitating high cost and endeavor to restore. The following study points out various problems that can be occurred occur as a result of high impedance grounding accident, and proposes a new system which can protect and intercept them.

  • PDF

Investigation of the real time stray current monitoring techniques on the DC railway system (직류전기철도에서의 실시간 누설전류 계측기법에 관한 조사분석)

  • Jung, Ho-Sung;Han, Moon-Seob;Park, Young;Kim, Hyeng-Chul;Kim, Jin-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2009.04b
    • /
    • pp.201-203
    • /
    • 2009
  • This paper presents the real time stray current monitoring techniques on the DC railway system. These techniques are two types. The first one is the rail potential measurement technique between running rail and earthing mats on the important locations such as substation, station, and so on. And the second one is measurement technique of stray current through substation earthing mats and from collection mats, and continuous monitoring of return currents through the running rails. We need to apply these techniques on DC railway system to monitor stray current periodically and maintain the system properly.

  • PDF

A Study on the Optical Gain Characteristics of a UV Line 250.199nm from Helium-Zinc Discharge Excited by CCRF with Overlapped DC (DC 중첩형 CCRF 여기 헬륨-아연방전에서 자외선 250.199nm의 광이득 특성 연구)

  • Choi, Sang Tae
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.7
    • /
    • pp.13-18
    • /
    • 2014
  • On 250.199nm uv-line, witch has the potential to emit as a laser line, from a ccrf-excited He-Zn discharge with overlapped DC was carried out optimization of the discharge parameters and measurement of the optical gain. In this study the optical gain of the 250.199nm uv-line has been optained 4% for the first time. At a rf-power of 400W with the frequency 13.56MHz the optimal He-pressure indicated 2kPa.

A Study on the Real Time Measuring Technique of Stray Current by Using Return Current Ratio in the DC Railway System (직류급전시스템에서의 귀환전류 변화비를 이용한 표유전류 실시간 감시기법에 관한 연구)

  • Jung, Ho-Sung;Park, Young;Kim, Hyeng-Chul;Min, Myung-Hwan;Shin, Myong-Chul
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.4
    • /
    • pp.892-898
    • /
    • 2011
  • In DC electric railways, while an electric rail car is driving, a part of the working current returned to the substation through rails leaks into the ground. Such a stray current causes railway facilities and metal objects to corrode electrolytically. Therefore, change of stray current needs to be monitored constantly. But so far in domestic, the research on stray current measuring techniques and system adaption are insufficient. To estimate stray current, this paper addresses a method of monitoring the return current that is returned into the negative pole of the substation in real time.

Investigation for the Report of DC Traction Stray Current Protection (도시철도 전식방지 조사보고 현황)

  • Lee, Hyun-Goo;Ha, Tae-Hyun;Jung, Ho-Sung;Han, Moon-Sub;Bae, Jeong-Hyo
    • Proceedings of the KSR Conference
    • /
    • 2008.11b
    • /
    • pp.281-285
    • /
    • 2008
  • Corrosion of metallic structures arises when an electric current flows from the metal into the electrolyte such as soil and water. The potential difference across the metal-electrolyte interface, the driving force for the corrosion current, can emerge due to a variety of temperature, pH, humidity and resistivity etc.. With respect to a given structure, a stray current is to be defined as a current flowing on a structure that is not part of the intended electrical circuit. Stray currents are caused by other cathodic protection installations, grounding systems and welding posts, referred to as steady state stray currents. But most often traction systems like railroads and tramlines are responsible for large dynamic stray currents. This type of stray current is generally results from the leakage of return currents from large DC traction systems that are grounded or have a bad earth-insulated return path. This paper investigates the reports, which is made for protecting the electrical corrosion by the DC traction stray current before the construction period.

  • PDF

Neutral-point Potential Balancing Method for Switched-Inductor Z-Source Three-level Inverter

  • Wang, Xiaogang;Zhang, Jie
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.3
    • /
    • pp.1203-1210
    • /
    • 2017
  • Switched-inductor (SL) Z-source three-level inverter is a novel high power topology. The SL based impedance network can boost the input dc voltage to a higher value than the single LC impedance network. However, as all the neutral-point-clamped (NPC) inverters, the SL Z-source three-level inverter has to balance the neutral-point (NP) potential too. The principle of the inverter is introduced and then the effects of NP potential unbalance are analyzed. A NP balancing method is proposed. Other than the methods for conventional NPC inverter without Z-source impedance network, the upper and lower shoot-through durations are corrected by the feedforward compensation factors. With the proposed method, the NP potential is balanced and the voltage boosting ability of the Z-source network is not affected obviously. Simulations are conducted to verify the proposed method.