• Title/Summary/Keyword: DC offset

Search Result 277, Processing Time 0.031 seconds

An Analytic Method for Measuring Accurate Fundamental Frequency Components (기본파 성분의 정확한 측정을 위한 해석적 방법)

  • Nam, Sun-Yeol;Gang, Sang-Hui;Park, Jong-Geun
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.51 no.4
    • /
    • pp.175-182
    • /
    • 2002
  • This paper proposes an analytic method for measuring the accurate fundamental frequency component of a fault current signal distorted with a DC-offset, a characteristic frequency component, and harmonics. The proposed algorithm is composed of four stages: sine filer, linear filter, Prony's method, and measurement. The sine filter and the linear filter eliminate harmonics and the fundamental frequency component, respectively. Then Prony's method is used to estimate the parameters of the DC-offset and the characteristic frequency component. Finally, the fundamental frequency component is measured by compensating the sine-filtered signal with the estimated parameters. The performance evaluation of the proposed method is presented for a-phase to around faults on a 345 kV 200 km overhead transmission line. The EMTP is used to generate fault current signals under different fault locations and fault inception angles. It is shown that the analytic method accurately measures the fundamental frequency component regardless of the characteristic frequency component as well as the DC-offset.

A Study on DC Offset Removal using Low-Pass Filter in AT Feeder System for Electric Railway (전기철도 AT급전계통에 Low-Pass Filter를 이용한 직류옵셋 제거에 관한 연구)

  • Lee, Hwan;Jung, No-Geon;Kim, Jae-Moon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.6
    • /
    • pp.1108-1114
    • /
    • 2016
  • The cause of failure in the AT feeding system is divided into grounding, short-circuit of feeding circuit and internal faults of the railway substation. Since the fault current is very high, real-time current is detected and the failure must be immediately removed. In this paper, a new DC offset elimination filter that can remove component to decrease in the form of exponential function using low-pass filter was proposed in order to extract the fundamental wave from distorted fault current. In order to confirm the performance of the proposed filter method, AT feeder system was modelled by simulation tool and simulations were performed under various conditions such as fault location, fault resistance and fault voltage phase angle in case of trolley-rail short-circuit fault. When applying the proposed DC-offset removal method, it can be seen that the phase delay and gain error did not appear.

Improved Reconstruction Algorithm for Spiral Scan Fast MR Imaging with DC offset Correction (DC offset을 보정한 나선 주사 초고속 자기공명영상의 재구성 알고리즘)

  • 안창범;김휴정
    • Journal of Biomedical Engineering Research
    • /
    • v.19 no.3
    • /
    • pp.243-250
    • /
    • 1998
  • Reconstruction aspects of spiral scan imaging for ultra fast magnetic resonance imagine(MRI) have been investigated with polar and rectangular coordinates-based reconstruction. For the reconstruction of the spiral scan imaging, acquired data in spiral trjectory should be converted to polar or rectangular grids, where interpolation techniques are used. Various reconstruction algorithms for spiral scan imaging are tested, and reconstructed image qualities are compared with computed phantom. An improved reconstruction algorithm with dc-offset correction in projection domain is proposed, which provides the best reconstructed image quality from the simulation. Image artifact with existing algorithms is completely removed with the proposed method.

  • PDF

A Study on Advanced Fault Locating for Short Fault of a Double Circuit Transmission Line (병행 2회선 송전선로의 선간단락시 고장점 표정의 개선에 관한 연구)

  • Park, Yu-Yeong;Park, Chul-Won
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.30 no.1
    • /
    • pp.28-37
    • /
    • 2016
  • Fault locating is an important element to minimize the damage of power system. The computation error of fault locator may occur by the influence of the DC offset component during phasor extraction. In order to minimize the bad effects of DC offset component, this paper presents an improved fault location algorithm based on a DC offset removal filter for short fault in a double circuit transmission line. We have modeled a 154kV double circuit transmission line by the ATP software to demonstrate the effectiveness of the proposed fault locating algorithm. The line to line short faults were simulated and then collected simulation data was used. It can be seen that the error rate of fault locating estimation by the proposed algorithm decreases than the error rate of fault locating estimation by conventional algorithm.

Compensation of Unbalanced Capacitor Voltage for Four-switch Three-phase Inverter Using DC Offset Current Injection (DC 오프셋 전류 주입에 의한 4-Switch 3-Phase Inverter의 커패시터 전압 불평형 보상)

  • Park, Young-Joo;Son, Sang-Hun;Choy, Ick
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.10 no.3
    • /
    • pp.365-373
    • /
    • 2015
  • The performance of 4-switch 3-phase inverter(FSTPI) is mainly affected by the unbalanced voltages between two capacitors which replace two switches of conventional 6-switch 3-phase inverter(SSTPI). This paper proposes a DC offset current injection method to compensate the capacitor voltage unbalance for FSTPI. A simplified SVPWM method which can be applied to FSTPI is also proposed. The validity of the proposed methods is verified by computer simulation.

Unified DC Offset Cancellation and I/Q Regeneration with Carrier Phase Recovery in Five-Port Junction based Direct Receivers (Five-port 접합을 이용한 RF 수신기를 위한 동시 DC 오프셋 제거와 I/Q 신호 재생 알고리즘)

  • Park, Hyung-Chul;Lim, Hyung-Sun;Yu, Jong-Won
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.44 no.6 s.360
    • /
    • pp.64-70
    • /
    • 2007
  • This paper presents a novel unified DC offset cancellation and I/Q regeneration for five-port junction based direct receivers. It utilizes the symmetry characteristics of the single-frequency continuous-wave (CW) signal, making it possible that the proposed method can be used regardless of carrier phase offset. The proposed method eliminates the additional DC offset cancellation and reduces the I/Q regeneration parameter estimation time. Since the proposed method employs a single-frequency CW signal independent of the modulation scheme, five-port junction based direct receivers can be used for the demodulation of orthogonal frequency-division multiplexing and continuous phase modulation as well as phase shift-keying.

Circuit Design for Noise Removal of Sine Wave Hall Sensor Signal (정현파 Hall Sensor 신호의 잡음제거를 위한 회로설계)

  • Jeong, Sungin
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.21 no.4
    • /
    • pp.135-141
    • /
    • 2021
  • Interest is growing in the design and development of square wave driven BLDC permanent magnet motors suitable for industrial automation, and the development of position detection circuits and drivers. However, this motor is somewhat limited in its application despite the price and functional advantages due to the decrease in efficiency due to switching loss and vibration and noise. In the process of designing and assembling a BLDC motor, the magnetic pole angle is not uniform or the magnetic flux distribution is distorted due to problems in magnetic circuit design or product non-uniformity in the assembly process. Therefore, these things cause position detection deviation and deteriorate the motor characteristics. In addition, the sine wave driven BLDC system can operate stably only when the signal generated from the position sensor is accurately fed back to the driver. However, since the generated signal cannot perform stable position detection due to the occurrence of DC offset component due to magnetic flux density deviation or magnetization technology, which is an external influence, this study intends to study the proposed circuit that can remove the DC offset component.

A New Digital Distance Relaying Algorithm Based on Fast Haar Transformation Techniques with Half a Cycle Offset Free Data (Offset이 제거된 반주기 테이터를 사용하는 고속Haar 변환에 기초한 디지털 거리계전 알고리)

  • 강상희;박종근
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.41 no.9
    • /
    • pp.973-983
    • /
    • 1992
  • A very fast algorithm, using fast Haar transformation with half a cycle dc-offset free data, to extract the power frequency components and to detect faults in power systems is proposed. For the speed-up, two important techniques are used. First, according to the symmetric characteristics of sine and cosine functions, fundamental frequency components are calculated with only half a cycle sample data. For using these characteristics, post-fault de-offset components must be removed beforehand. Therefore, secondly, a newly designed digital filter is used to remove exponentially decaying dc-offset from the post-fault signal. In accordance with series simulations, transmission line faults can be detected in around half a cycle after faults.

Performance of Direct-Conversion Receiver with AC-Coupling in DC-Offset interference environment (DC-Offset 간섭환경에서 AC-Coupling을 갖는 직접변환 수신기의 성능)

  • 성봉훈;송윤정;김영완;김내수;서종수
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 2002.11a
    • /
    • pp.9-14
    • /
    • 2002
  • Direct-conversion receiver(DCR) architecture has superior advantages in size, cost, and power over superheterodyne receiver architectures. However, the use of direct-conversion receiver architecture has been limited due to the direct-current offset noise. The ac coupling, which is used to overcome the direct-current offset noise, causes an inter-symbol interference(ISI), whose effects can be effectively mitigated using an equalizer. In this paper, the performance of a direct-conversion receiver with ac coupling in the presence of direct-current offset is analyzed via computer simulation. The simulation result shows that by using decision feedback equalizer with LMS(Least Mean Square) algorithm, signal-to-noise ratio loss of the direct-conversion receiver compared to the idea receiver can be reduced to less than 1㏈ for corner frequencies as large as 10% of the symbol rate.

  • PDF

DC-DC Boost Converter using Offset-Controlled Zero Current Sensor for Low Loss Thermoelectric Energy Harvesting Circuit (저 손실 열전변환 하베스팅을 위해 제로전류센서의 오프셋을 조절하는 부스트 컨버터)

  • Joo, Sunghwan;Kim, Kiryong;Jung, Dong-Hoon;Jung, Seong-Ook
    • Journal of IKEEE
    • /
    • v.20 no.4
    • /
    • pp.373-377
    • /
    • 2016
  • This paper presents a low power boost converter using offset controlled Zero Current Sensor (ZCS) control for thermoelectric energy harvesting.[1] [5] Offset controlled ZCS uses adjustable pre-offset that is controled by 6bit code each connected gate of NMOS for switching. Offset controlled ZCS demonstrates an efficiency that is higher than using analog comparator ZCS and that is smaller area than using delay line ZCS. Experimentally, the offset controlled ZCS system consumes 10 times less power than analog comparator ZCS based system at similar performance.