• Title/Summary/Keyword: DC link inverter

Search Result 449, Processing Time 0.027 seconds

Low Cost and High Performance UPQC with Four-Switch Three-Phase Inverters

  • Trinh, Quoc-Nam;Lee, Hong-Hee
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.3
    • /
    • pp.1015-1024
    • /
    • 2015
  • This paper introduces a low cost, high efficiency, high performance three-phase unified power quality conditioner (UPQC) by using four-switch three-phase inverters (FSTPIs) and an extra capacitor in the shunt active power filter (APF) side of the UPQC. In the proposed UPQC, both shunt and series APFs are developed by using FSTPIs so that the number of switching devices is reduced from twelve to eight devices. In addition, by inserting an additional capacitor in series with the shunt APF, the DC-link voltage in the proposed UPQC can also be greatly reduced. As a result, the system cost and power loss of the proposed UPQC is significantly minimized thanks to the use of a smaller number of power switches with a lower rating voltage without degrading the compensation performance of the UPQC. Design of passive components for the proposed UPQC to achieve a good performance is presented in detail. In addition, comparisons on power loss, overall system efficiency, compensation performance between the proposed UPQC and the traditional one are also determined in this paper. Simulation and experimental studies are performed to verify the validity of the proposed topology.

State-of-Charge Balancing Control of a Battery Power Module for a Modularized Battery for Electric Vehicle

  • Choi, Seong-Chon;Jeon, Jin-Yong;Yeo, Tae-Jung;Kim, Young-Jae;Kim, Do-Yun;Won, Chung-Yuen
    • Journal of Electrical Engineering and Technology
    • /
    • v.11 no.3
    • /
    • pp.629-638
    • /
    • 2016
  • This paper proposes a State-of-Charge (SOC) balancing control of Battery Power Modules (BPMs) for a modularized battery for Electric Vehicles (EVs) without additional balancing circuits. The BPMs are substituted with the single converter in EVs located between the battery and the inverter. The BPM is composed of a two-phase interleaved boost converter with battery modules. The discharge current of each battery module can be controlled individually by using the BPM to achieve a balanced state as well as increased utilization of the battery capacity. Also, an SOC balancing method is proposed to reduce the equalization time, which satisfies the regulation of a constant DC-link voltage and a demand of the output power. The proposed system and the SOC balancing method are verified through simulation and experiment.

Resonance Suppression Control of Input Current for Capacitorless Inverter (캐패시터리스 인버터의 입력 전류 공진 억제)

  • Yoo, An-No;Lee, Hak-Jun;Lee, Wook-Jin;Sul, Seung-Ki;Dehkordi, Behzad Mirzaeian;Kim, Sun-Ja;Na, Seung-Ho;Kim, Jeong-Ha
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.888-889
    • /
    • 2008
  • 본 논문은 직류단 전원(DC link)에 대용량의 전해 캐패시터(Electrolytic capacitor)를 사용하지 않는 전해 캐패시터리스 (Electrolytic-Capacitorless) 인버터의 입력 전류와 직류단 전원 공진(resonance) 억제에 대한 것이다. 직류단 전원의 순시적인 에너지원으로 사용되는 전해 캐패시터를 사용하지 않는 캐패시터리스 인버터는 기존의 인버터에 비해서 가격, 부피 면에서 장점을 가지지만, 직류단 전원의 캐패시터 용량이 작아서 부하 단 스위칭의 영향이 입력 전류에 직접적으로 나타나게 된다. 이에 따라서 캐패시터리스 인버터는 필연적으로 입력 단에 저역 통과 필터(Low Pass Filter : LPF)가 필요하다. 입력 단의 필터는 간단한 구조와 가격적 측면을 고려하여 LC 필터가 주로 사용되는데, LC필터는 직류단 전류에 의한 공진의 원인이 된다. 본 논문에서는 캐패시터리스 인버터의 입력 필터의 영향을 분석하여 입력 전류와 직류단 전압의 공진을 억제 할 수 있는 방법을 제시하고, 실험 결과를 통하여 제안된 방법의 유효성을 확인한다.

  • PDF

The Design of Digital Controller for Boost Converter on Photovoltaic System (태양광용 부스트 컨버터의 디지털 제어기 설계)

  • Im, Ji-Hoon;Choi, Ju-Yeop;Song, Seung-Ho;Choy, Ick;Jeong, Seung-Hwan;An, Jin-Ung;Lee, Dong-Ha
    • Journal of the Korean Solar Energy Society
    • /
    • v.30 no.6
    • /
    • pp.22-27
    • /
    • 2010
  • In photovoltaic system, the specifications of solar array is changed as open circuit voltage and short circuit current because of cell temperature and solar radiation. A boost converter of this system connects between output of photovoltaic system and DC link capacitor of grid connected inverter as controlling duty ratio. Therefore to supply stable voltage to the grid, a boost converter is need to keep certain voltage output. Considering the capacitance and the resistance of boost converter, this paper designed proper digital controller.

Experimental Assessment with Wind Turbine Emulator of Variable-Speed Wind Power Generation System using Boost Chopper Circuit of Permanent Magnet Synchronous Generator

  • Tammaruckwattana, Sirichai;Ohyama, Kazuhiro;Yue, Chenxin
    • Journal of Power Electronics
    • /
    • v.15 no.1
    • /
    • pp.246-255
    • /
    • 2015
  • This paper presents experimental results and its assessment of a variable-speed wind power generation system (VSWPGS) using permanent magnet synchronous generator (PMSG) and boost chopper circuit (BCC). Experimental results are obtained by a test bench with a wind turbine emulator (WTE). WTE reproduces the behaviors of a windmill by using servo motor drives. The mechanical torque references to drive the servo motor are calculated from the windmill wing profile, wind velocity, and windmill rotational speed. VSWPGS using PMSG and BCC has three speed control modes for the level of wind velocity to control the rotational speed of the wind turbine. The control mode for low wind velocity regulates an armature current of generator with BCC. The control mode for middle wind velocity regulates a DC link voltage with a vector-controlled inverter. The control mode for high wind velocity regulates a pitch angle of the wind turbine with a pitch angle control system. The hybrid of three control modes extends the variable-speed range. BCC simplifies the maintenance of VSWPGS while improving reliability. In addition, VSWPGS using PMSG and BCC saves cost compared with VSWPGS using a PWM converter.

Development of High-speed Elevator Drive System using Permanent-magnet Synchronous Motor (영구 자석형 동기 전동기를 이용한 고속 엘리베이터 구동 시스템 개발)

  • Ryu Hyung-Min;Kim Sung-Jun;Sul Seung-Ki;Kwon Tae-Seok;Kim Ki-Su;Shim Young-Seok;Seok Ki-Riong
    • Proceedings of the KIPE Conference
    • /
    • 2001.07a
    • /
    • pp.385-388
    • /
    • 2001
  • In this paper, the gearless traction machine drive system using a permanent-maget motor for high-speed elevators is addressed. This application of permanent-magnet motor to the elevator traction machine enables several improvements including higher efficiency, better ride comfort, smaller size and weight, and so on. PWM boost converter is also adopted so that DC-link voltage regulation, hi-directional power flow, and controllable power factor with reduced input current harmonics are possible. To increase reliability and performance, the control board, which can include the car and group controller as well as PWM converter and inverter controller, is designed based on TMS320VC33 DSP The simulator system for high-speed elevators has been developed so that the drive system of high-speed elevator can be tested without my limitation on ride distance and the load condition. Some experimental results are given to verify the effectiveness of the developed system.

  • PDF

A Performance Comparison between LLCL and LCL filters to Reduce Harmonic Current of Regeneration Power Inverter for Elevator (엘리베이터 회생용 인버터의 고조파 전류저감을 위한 LLCL 필터와 LCL 필터의 성능 비교)

  • An, Byoung-Woong;Jin, Yong-Sin;Kim, Hag-Wone;Cho, Kwan-Yuhl;Lim, Byung-Kuk;Shin, Hee-Kuen;Lee, Yong-Gue
    • Proceedings of the KIPE Conference
    • /
    • 2012.07a
    • /
    • pp.264-266
    • /
    • 2012
  • 엘리베이터 제동 시 발생하는 인버터 회생 전류는 많은 고조파를 포함하고 있다. 기존의 회생용 인버터는 계통 측 필터로 L필터가 많이 사용되어 왔으나, 고조파를 저감하기 위해서 매우 큰 L값을 요구한다. 하지만 엘리베이터 회생용 인버터는 기설치된 DC Link 과전압 방지 방전회로가 동작되기 전에 회생을 실시하여야 하므로, 상대적으로 낮은 전압에서 회생되어야 하므로 큰 임피던스를 갖는 L필터를 사용하기 어렵다. 본 논문에서는 엘리베이터 회생용 인버터의 리플저감용 LCL 필터와 최근 제안된 LLCL 필터의 성능을 비교 분석하고 모의해석과 실험을 통해 그 타당성을 입증 하였다.

  • PDF

A Pre-Regulated Single-Sourced 27-level ACHB Inverter without Regeneration (회생모드가 없는 단일전원 27레벨 캐스케이드 H-브리지 인버터)

  • Manoharan, Mohana Sundar;Ahmed, Ashraf;Lee, Chun-Gu;Park, Joung-Hu
    • Proceedings of the KIPE Conference
    • /
    • 2015.11a
    • /
    • pp.95-96
    • /
    • 2015
  • In this paper, a single-sourced PV PCS using the trinary asymmetric MLI with a single-ended pre-regulator is proposed. Trinary based asymmetric CHB inverters provide higher output levels for the same number of cells compared to other CHB inverters. However, there is an issue of regeneration with trinary asymmetric inverters and this complicates the system with requirement of bi-directional converters at the input. Modified commutation strategies have been used to remove the regeneration issue with compromise in THD. The single-ended pre-regulator provides the isolated dc-link voltage for the individual H-bridge cells with the advantage of having a single switch and magnetic component. This implementation increases the magnetic utilization of the inductor core and reduces the switching loss in the pre-regulator and also the reduced parts count contributes to the cost competiveness of the proposed PCS. The proposed PV PCS has been verified using simulation results in this paper.

  • PDF

Torque Predictive Control for Permanent Magnet Synchronous Motor Drives Using Indirect Matrix Converter

  • Bak, Yeongsu;Jang, Yun;Lee, Kyo-Beum
    • Journal of Power Electronics
    • /
    • v.19 no.6
    • /
    • pp.1536-1543
    • /
    • 2019
  • This paper presents an improved torque predictive control (TPC) for permanent magnet synchronous motors (PMSMs) using an indirect matrix converter (IMC). The IMC has characteristics such as a high power density and sinusoidal waveforms of the input-output currents. Additionally, this configuration does not have any DC-link capacitors. Due to these advantages of the IMC, it is used in various application field such as electric vehicles and railway cars. Recently, research on various torque control methods for PMSM drives using an IMC is being actively pursued. In this paper, an improved TPC method for PMSM drives using an IMC is proposed. In the improved TPC method, the magnitudes of the voltage vectors applied to control the torque and flux of the PMSM are adjusted depending on the PMSM torque control such as the steady state and transient response. Therefore, it is able to reduce the ripples of the output current and torque in the low-speed and high-speed load ranges. Additionally, the improved TPC can improve the dynamic torque response when compared with the conventional TPC. The effectiveness of the improved TPC method is verified by experimental results.

A Novel Harmonic Compensation Technique for the Grid-Connected Inverters (계통연계 인버터를 위한 새로운 고조파 보상법)

  • Ashraf, Muhammad Noman;Khan, Reyyan Ahmad;Choi, Woojin
    • Proceedings of the KIPE Conference
    • /
    • 2019.07a
    • /
    • pp.71-73
    • /
    • 2019
  • The output current of the Grid Connected Inverter (GCI) can be polluted with harmonics mainly due to i) dead time in switches, ii) non-linearity of switches, iii) grid harmonics, and iv) DC link fluctuation. Therefore, it is essential to design the robust Harmonic Compensation (HC) technique for the improvement of output current quality and fulfill the IEEE 1547 Total harmonics Distortion (THD) limit i.e. <5%. The conventional harmonic techniques often are complex in implementation due to their i) additional hardware needs, ii) complex structure, iii) difficulty in tuning of parameters, iv) current controller compatibility issues, and v) higher computational burden. In this paper, to eliminate the harmonics from the GCI output current, a novel Digital Lock-In Amplifier (DLA) based harmonic detection is proposed. The advantage of DLA is that it extracts the harmonic information accurately, which is further compensated by means of PI controller in feed forward manner. Moreover, the proposed HC method does not require additional hardware and it works with any current controller reference frame. To show the effectiveness of the proposed HC method a 5kW GCI prototype built in laboratory. The output current THD is achieved less than 5% even with 10% load, which is verified by simulation and experiment.

  • PDF